메뉴 건너뛰기




Volumn 20, Issue , 2013, Pages 305-315

A non-biological model system to simulate the in vivo mechanical behavior of prosthetic meshes

Author keywords

Biaxial tension; In vivo behavior; Mechanical properties; Mesh matrix interaction; Prosthetic mesh

Indexed keywords

ABDOMINAL WALL DEFECTS; BIAXIAL TENSIONS; ENGINEERING OPTIMIZATION; IN-VIVO; MECHANICAL CHARACTERIZATIONS; MESH MATRIX INTERACTION; STIFFNESS PARAMETERS; TESTING CONFIGURATIONS;

EID: 84875903397     PISSN: 17516161     EISSN: 18780180     Source Type: Journal    
DOI: 10.1016/j.jmbbm.2013.01.029     Document Type: Article
Times cited : (24)

References (44)
  • 1
    • 80052495447 scopus 로고    scopus 로고
    • Incidence and management of graft erosion, wound granulation, and dyspareunia following vaginal prolapse repair with graft materials: a systematic review
    • Abed H., Rahn D.D., Lowenstein L., Balk E.M., Clemons J.L., Rogers R.G., Gynecologi S.R.G.S. Incidence and management of graft erosion, wound granulation, and dyspareunia following vaginal prolapse repair with graft materials: a systematic review. International Urogynecology Journal 2011, 22:789-798.
    • (2011) International Urogynecology Journal , vol.22 , pp. 789-798
    • Abed, H.1    Rahn, D.D.2    Lowenstein, L.3    Balk, E.M.4    Clemons, J.L.5    Rogers, R.G.6    Gynecologi, S.R.G.S.7
  • 5
    • 70349542910 scopus 로고    scopus 로고
    • Biomechanical comparison of four soft tissue replacement materials: an in vitro evaluation of single and multilaminate porcine small intestinal submucosa, Canine Fascia Lata, and Polypropylene Mesh
    • Arnold G.A., Mathews K.G., Roe S., Mente P., Seaboch T. Biomechanical comparison of four soft tissue replacement materials: an in vitro evaluation of single and multilaminate porcine small intestinal submucosa, Canine Fascia Lata, and Polypropylene Mesh. Veterinary Surgery 2009, 38:834-844.
    • (2009) Veterinary Surgery , vol.38 , pp. 834-844
    • Arnold, G.A.1    Mathews, K.G.2    Roe, S.3    Mente, P.4    Seaboch, T.5
  • 8
    • 18144399663 scopus 로고    scopus 로고
    • The argument for lightweight polypropylene mesh in hernia repair
    • Cobb W.S., Kercher K.W., Heniford B.T. The argument for lightweight polypropylene mesh in hernia repair. Surgical Innovation 2005, 12:63-69.
    • (2005) Surgical Innovation , vol.12 , pp. 63-69
    • Cobb, W.S.1    Kercher, K.W.2    Heniford, B.T.3
  • 9
    • 78650615544 scopus 로고    scopus 로고
    • Physicomechanical evaluation of polypropylene, polyester, and polytetrafluoroethylene meshes for inguinal hernia repair
    • Deeken C.R., Abdo M.S., Frisella M.M., Matthews B.D. Physicomechanical evaluation of polypropylene, polyester, and polytetrafluoroethylene meshes for inguinal hernia repair. Journal of the American College of Surgeons 2011, 212:68-79.
    • (2011) Journal of the American College of Surgeons , vol.212 , pp. 68-79
    • Deeken, C.R.1    Abdo, M.S.2    Frisella, M.M.3    Matthews, B.D.4
  • 12
    • 34547145165 scopus 로고    scopus 로고
    • GPower 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences
    • Faul F., Erdfelder E., Lang A.-G., Buchner A. GPower 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behavior Research Methods 2007, 39:175-191.
    • (2007) Behavior Research Methods , vol.39 , pp. 175-191
    • Faul, F.1    Erdfelder, E.2    Lang, A.-G.3    Buchner, A.4
  • 13
    • 76549131047 scopus 로고    scopus 로고
    • Vaginal mesh contraction definition, clinical presentation, and management
    • Feiner B., Maher C. Vaginal mesh contraction definition, clinical presentation, and management. Obstetrics & Gynecology 2010, 115:325-330.
    • (2010) Obstetrics & Gynecology , vol.115 , pp. 325-330
    • Feiner, B.1    Maher, C.2
  • 16
    • 78651080392 scopus 로고    scopus 로고
    • An international urogynecological association (IUGA)/international continence society (ICS) joint terminology and classification of the complications related directly to the insertion of prostheses (meshes, implants, tapes) and grafts in female pelvic floor surgery
    • Haylen B.T., Freeman R.M., Swift S.E., Cosson M., Davila G.W., Deprest J., Dwyer P.L., Fatton B., Kocjancic E., Lee J., Maher C., Petri E., Rizk D.E., Sand P.K., Schaer G.N., Webb R. An international urogynecological association (IUGA)/international continence society (ICS) joint terminology and classification of the complications related directly to the insertion of prostheses (meshes, implants, tapes) and grafts in female pelvic floor surgery. Neurourology and Urodynamics 2011, 30:2-12.
    • (2011) Neurourology and Urodynamics , vol.30 , pp. 2-12
    • Haylen, B.T.1    Freeman, R.M.2    Swift, S.E.3    Cosson, M.4    Davila, G.W.5    Deprest, J.6    Dwyer, P.L.7    Fatton, B.8    Kocjancic, E.9    Lee, J.10    Maher, C.11    Petri, E.12    Rizk, D.E.13    Sand, P.K.14    Schaer, G.N.15    Webb, R.16
  • 18
    • 81155154368 scopus 로고    scopus 로고
    • A novel experimental procedure based on pure shear testing of dermatome-cut samples applied to porcine skin
    • Hollenstein M., Ehret A.E., Itskov M., Mazza E. A novel experimental procedure based on pure shear testing of dermatome-cut samples applied to porcine skin. Biomechanics and Modeling in Mechanobiology 2011, 10:651-661.
    • (2011) Biomechanics and Modeling in Mechanobiology , vol.10 , pp. 651-661
    • Hollenstein, M.1    Ehret, A.E.2    Itskov, M.3    Mazza, E.4
  • 19
    • 56349132181 scopus 로고    scopus 로고
    • Biomechanical properties of lightweight versus heavyweight meshes for laparoscopic inguinal hernia repair and their impact on recurrence rates
    • Hollinsky C., Sandberg S., Koch T., Seidler S. Biomechanical properties of lightweight versus heavyweight meshes for laparoscopic inguinal hernia repair and their impact on recurrence rates. Surgical Endoscopy 2008, 22:2679-2685.
    • (2008) Surgical Endoscopy , vol.22 , pp. 2679-2685
    • Hollinsky, C.1    Sandberg, S.2    Koch, T.3    Seidler, S.4
  • 21
    • 32044451580 scopus 로고    scopus 로고
    • Influence of polyglecaprone 25 (Monocryl) supplementation on the biocompatibility of a polypropylene mesh for hernia repair
    • Junge K., Rosch R., Krones C.J., Klinge U., Mertens P.R., Lynen P., Schumpelick V., Klosterhalfen B. Influence of polyglecaprone 25 (Monocryl) supplementation on the biocompatibility of a polypropylene mesh for hernia repair. Hernia 2005, 9:212-217.
    • (2005) Hernia , vol.9 , pp. 212-217
    • Junge, K.1    Rosch, R.2    Krones, C.J.3    Klinge, U.4    Mertens, P.R.5    Lynen, P.6    Schumpelick, V.7    Klosterhalfen, B.8
  • 23
    • 84875906595 scopus 로고    scopus 로고
    • Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: a comparison of six state-of-the-art meshes
    • Konerding M.A., Chantereau P., Delventhal V., Holste J.-L., Ackermann M. Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: a comparison of six state-of-the-art meshes. Medical Engineering & Physics 2011.
    • (2011) Medical Engineering & Physics
    • Konerding, M.A.1    Chantereau, P.2    Delventhal, V.3    Holste, J.-L.4    Ackermann, M.5
  • 24
    • 34249979735 scopus 로고    scopus 로고
    • Tensile strength and host response towards different polypropylene implant materials used for augmentation of fascial repair in a rat model
    • Konstantinovic M., Pille E., Malinowska M., Verbeken E., De Ridder D., Deprest J. Tensile strength and host response towards different polypropylene implant materials used for augmentation of fascial repair in a rat model. International Urogynecology Journal 2007, 18:619-626.
    • (2007) International Urogynecology Journal , vol.18 , pp. 619-626
    • Konstantinovic, M.1    Pille, E.2    Malinowska, M.3    Verbeken, E.4    De Ridder, D.5    Deprest, J.6
  • 25
  • 30
    • 84874689916 scopus 로고    scopus 로고
    • R-Core-Team, R: A Language and Environment for Statistical Computing
    • R Foundation for Statistical Computing, Vienna, Austria.
    • R-Core-Team, 2012. R: A Language and Environment for Statistical Computing. R Foundation for Statistical Computing, Vienna, Austria.
    • (2012)
  • 33
    • 79951725306 scopus 로고    scopus 로고
    • Anisotropic evaluation of synthetic surgical meshes
    • Saberski E.R., Orenstein S.B., Novitsky Y.W. Anisotropic evaluation of synthetic surgical meshes. Hernia 2011, 15:47-52.
    • (2011) Hernia , vol.15 , pp. 47-52
    • Saberski, E.R.1    Orenstein, S.B.2    Novitsky, Y.W.3
  • 34
    • 0034434786 scopus 로고    scopus 로고
    • Biaxial mechanical evaluation of planar biological materials
    • Sacks M.S. Biaxial mechanical evaluation of planar biological materials. Journal of Elasticity 2000, 61:199-246.
    • (2000) Journal of Elasticity , vol.61 , pp. 199-246
    • Sacks, M.S.1
  • 36
    • 84875898076 scopus 로고    scopus 로고
    • Uniaxial tensile properties prior to and after resorption of a partially delayed absorbable mesh for vaginal repair of pelvic organ prolapse
    • Shepherd J.P., Feola A.J., Abramowitch S.D., Moalli P.A. Uniaxial tensile properties prior to and after resorption of a partially delayed absorbable mesh for vaginal repair of pelvic organ prolapse. International Urogynecology Journal 2010, 21:S75-S76.
    • (2010) International Urogynecology Journal , vol.21
    • Shepherd, J.P.1    Feola, A.J.2    Abramowitch, S.D.3    Moalli, P.A.4
  • 37
    • 84863085588 scopus 로고    scopus 로고
    • Uniaxial biomechanical properties of seven different vaginally implanted meshes for pelvic organ prolapse
    • Shepherd J.P., Feola A.J., Abramowitch S.D., Moalli P.A. Uniaxial biomechanical properties of seven different vaginally implanted meshes for pelvic organ prolapse. International Urogynecology Journal 2012, 23:613-620.
    • (2012) International Urogynecology Journal , vol.23 , pp. 613-620
    • Shepherd, J.P.1    Feola, A.J.2    Abramowitch, S.D.3    Moalli, P.A.4
  • 38
    • 84863113036 scopus 로고    scopus 로고
    • A standardized description of graft-containing meshes and recommended steps before the introduction of medical devices for prolapse surgery, consensus of the 2nd IUGA grafts roundtable: optimizing safety and appropriateness of graft use in transvaginal pelvic reconstructive surgery
    • Slack M., Ostergard D., Cervigni M., Deprest J. A standardized description of graft-containing meshes and recommended steps before the introduction of medical devices for prolapse surgery, consensus of the 2nd IUGA grafts roundtable: optimizing safety and appropriateness of graft use in transvaginal pelvic reconstructive surgery. International Urogynecology Journal 2012, 23:15-26.
    • (2012) International Urogynecology Journal , vol.23 , pp. 15-26
    • Slack, M.1    Ostergard, D.2    Cervigni, M.3    Deprest, J.4
  • 39
    • 79960952572 scopus 로고    scopus 로고
    • Effects of age on the elastic properties of the intraluminal thrombus and the thrombus-covered wall in abdominal aortic aneurysms: biaxial extension behaviour and material modelling
    • Tong J., Cohnert T., Regitnig P., Holzapfel G.A. Effects of age on the elastic properties of the intraluminal thrombus and the thrombus-covered wall in abdominal aortic aneurysms: biaxial extension behaviour and material modelling. European Journal of Vascular and Endovascular 2011, 42:207-219.
    • (2011) European Journal of Vascular and Endovascular , vol.42 , pp. 207-219
    • Tong, J.1    Cohnert, T.2    Regitnig, P.3    Holzapfel, G.A.4
  • 40
    • 0005248386 scopus 로고    scopus 로고
    • US Food and Drug Administration
    • FDA safety communication: Update on serious complications associated with transvaginal placement of surgical mesh for pelvic organ prolapse, .
    • US Food and Drug Administration, 2011. FDA safety communication: Update on serious complications associated with transvaginal placement of surgical mesh for pelvic organ prolapse, http://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm262435.htm.
    • (2011)
  • 42
    • 0036798929 scopus 로고    scopus 로고
    • Boundary conditions during biaxial testing of planar connective tissues Part 1 dynamic behavior
    • Waldman S.D., Lee J.M. Boundary conditions during biaxial testing of planar connective tissues Part 1 dynamic behavior. Journal of Materials Science: Materials in Medicine 2002, 13:933-938.
    • (2002) Journal of Materials Science: Materials in Medicine , vol.13 , pp. 933-938
    • Waldman, S.D.1    Lee, J.M.2
  • 43
    • 33847359520 scopus 로고    scopus 로고
    • Mechanical behavior of an acrylic elastomer used in dielectric elastomer actuators
    • Wissler M., Mazza E. Mechanical behavior of an acrylic elastomer used in dielectric elastomer actuators. Sensors and Actuators A: Physical 2007, 134:494-504.
    • (2007) Sensors and Actuators A: Physical , vol.134 , pp. 494-504
    • Wissler, M.1    Mazza, E.2
  • 44
    • 77956190012 scopus 로고    scopus 로고
    • A constitutive model for the warp-weft coupled non-linear behavior of knitted biomedical textiles
    • Yeoman M.S., Reddy D., Bowles H.C., Bezuidenhout D., Zilla P., Franz T. A constitutive model for the warp-weft coupled non-linear behavior of knitted biomedical textiles. Biomaterials 2010, 31:8484-8493.
    • (2010) Biomaterials , vol.31 , pp. 8484-8493
    • Yeoman, M.S.1    Reddy, D.2    Bowles, H.C.3    Bezuidenhout, D.4    Zilla, P.5    Franz, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.