메뉴 건너뛰기




Volumn 52, Issue , 2013, Pages 245-257

Cooling performance of a 100% outdoor air system integrated with indirect and direct evaporative coolers

Author keywords

100 outdoor air system; Direct evaporative cooler; Heat reclaim; Indirect evaporative cooler; Sensible heat exchanger

Indexed keywords

ENERGY UTILIZATION;

EID: 84875809381     PISSN: 03605442     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.energy.2013.02.008     Document Type: Article
Times cited : (78)

References (11)
  • 1
    • 33847034862 scopus 로고    scopus 로고
    • Development and testing of two-stage evaporative cooler
    • Jain D. Development and testing of two-stage evaporative cooler. Building and Environment 2007, 42(7):2549-2554.
    • (2007) Building and Environment , vol.42 , Issue.7 , pp. 2549-2554
    • Jain, D.1
  • 2
    • 0028464553 scopus 로고
    • Feasibility of direct-indirect evaporative cooling for residences, based on studies with a desert cooler
    • Navon R., Arkin H. Feasibility of direct-indirect evaporative cooling for residences, based on studies with a desert cooler. Building and Environment 1994, 29(3):393-399.
    • (1994) Building and Environment , vol.29 , Issue.3 , pp. 393-399
    • Navon, R.1    Arkin, H.2
  • 3
    • 67349179461 scopus 로고    scopus 로고
    • Experimental investigation of two-stage indirect/direct evaporative cooling system in various climatic conditions
    • Heidarinejad G., Bozorgmehr M., Delfani S., Esmaeelian J. Experimental investigation of two-stage indirect/direct evaporative cooling system in various climatic conditions. Building and Environment 2009, 44(10):2073-2079.
    • (2009) Building and Environment , vol.44 , Issue.10 , pp. 2073-2079
    • Heidarinejad, G.1    Bozorgmehr, M.2    Delfani, S.3    Esmaeelian, J.4
  • 5
    • 77949337977 scopus 로고    scopus 로고
    • An experimental study of a novel dew point evaporative cooling system
    • Riangvilaikul B., Kumar S. An experimental study of a novel dew point evaporative cooling system. Energy and Buildings 2009, 42(5):637-644.
    • (2009) Energy and Buildings , vol.42 , Issue.5 , pp. 637-644
    • Riangvilaikul, B.1    Kumar, S.2
  • 6
    • 0035340924 scopus 로고    scopus 로고
    • Energy saving potential of an indirect evaporative cooler
    • Maheshwari G.P., Al-Ragom F., Suri R.K. Energy saving potential of an indirect evaporative cooler. Applied Energy 2001, 69(1):69-76.
    • (2001) Applied Energy , vol.69 , Issue.1 , pp. 69-76
    • Maheshwari, G.P.1    Al-Ragom, F.2    Suri, R.K.3
  • 7
    • 82555185469 scopus 로고    scopus 로고
    • Comparative study of the performance of the M-cycle counter-flow and cross-flow heat exchangers for indirect evaporative cooling - paving the path toward sustainable cooling of buildings
    • Zhan C., Duan Z., Zhao X., Smith S., Jin H., Riffat S. Comparative study of the performance of the M-cycle counter-flow and cross-flow heat exchangers for indirect evaporative cooling - paving the path toward sustainable cooling of buildings. Energy 2011, 36(12):6790-6805.
    • (2011) Energy , vol.36 , Issue.12 , pp. 6790-6805
    • Zhan, C.1    Duan, Z.2    Zhao, X.3    Smith, S.4    Jin, H.5    Riffat, S.6
  • 8
    • 84859110342 scopus 로고    scopus 로고
    • Exergy analysis of evaporative cooling to select the optimum system in diverse climates
    • Farmahini-Farahani M., Delfani S., Esmaeelian J. Exergy analysis of evaporative cooling to select the optimum system in diverse climates. Energy 2012, 40(1):250-257.
    • (2012) Energy , vol.40 , Issue.1 , pp. 250-257
    • Farmahini-Farahani, M.1    Delfani, S.2    Esmaeelian, J.3
  • 11
    • 84862819690 scopus 로고    scopus 로고
    • Energy performance of an evaporative cooler assisted 100% outdoor air system in the heating season operation
    • Kim M.H., Choi A.S., Jeong J.W. Energy performance of an evaporative cooler assisted 100% outdoor air system in the heating season operation. Energy and Buildings 2012, 49:402-409.
    • (2012) Energy and Buildings , vol.49 , pp. 402-409
    • Kim, M.H.1    Choi, A.S.2    Jeong, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.