메뉴 건너뛰기




Volumn 110, Issue 4, 2013, Pages 659-661

Technology comparison studies require precise reference controls to be valid

Author keywords

[No Author keywords available]

Indexed keywords

AORTA; BLOOD VESSEL TONE; CLINICAL PRACTICE; COLORECTAL SURGERY; DOPPLER DEVICE; ESOPHAGEAL DOPPLER; GOLD STANDARD; HEART STROKE VOLUME; HEMODYNAMICS; HUMAN; LETTER; MEAN ARTERIAL PRESSURE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; THERMODILUTION; TIDAL VOLUME; VALIDATION STUDY;

EID: 84875680322     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aet041     Document Type: Letter
Times cited : (3)

References (9)
  • 1
    • 84874382964 scopus 로고    scopus 로고
    • Stroke volume optimization in elective bowel surgery: A comparison between pulse power wave analysis (LiDCOrapid) and oesophageal Doppler (CardioQ)
    • Nordstrom J, Hallsjo-Sander C, Shore R, Bjorne H. Stroke volume optimization in elective bowel surgery: a comparison between pulse power wave analysis (LiDCOrapid) and oesophageal Doppler (CardioQ). Br J Anaesth 2013; 110: 374-80
    • (2013) Br J Anaesth , vol.110 , pp. 374-380
    • Nordstrom, J.1    Hallsjo-Sander, C.2    Shore, R.3    Bjorne, H.4
  • 2
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley L, Critchley J. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999; 15: 85-91
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.1    Critchley, J.2
  • 3
    • 68849121782 scopus 로고    scopus 로고
    • Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies - With specific reference to the measurement of cardiac output
    • Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds M. Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies - with specific reference to the measurement of cardiac output. Crit Care 2009; 13: 201
    • (2009) Crit Care , vol.13 , pp. 201
    • Cecconi, M.1    Rhodes, A.2    Poloniecki, J.3    Della Rocca, G.4    Grounds, M.5
  • 4
    • 72449160043 scopus 로고    scopus 로고
    • Transesophageal Doppler devices: A technical review
    • Schober P, Loer A, Schwarte A. Transesophageal Doppler devices: a technical review. J Clin Monit Comput 2009; 23: 391-401
    • (2009) J Clin Monit Comput , vol.23 , pp. 391-401
    • Schober, P.1    Loer, A.2    Schwarte, A.3
  • 5
    • 33846449483 scopus 로고    scopus 로고
    • Measuring aortic diameter improves accuracy of esophageal Doppler in assessing fluid responsiveness
    • Monnet X, Chemla D, Osman D, et al. Measuring aortic diameter improves accuracy of esophageal Doppler in assessing fluid responsiveness. Crit Care Med 2007; 35: 477-82
    • (2007) Crit Care Med , vol.35 , pp. 477-482
    • Monnet, X.1    Chemla, D.2    Osman, D.3
  • 6
    • 0034985226 scopus 로고    scopus 로고
    • Oesophageal Doppler monitoring overestimates cardiac output during lumbar epidural anaesthesia
    • Leather H, Wouters P. Oesophageal Doppler monitoring overestimates cardiac output during lumbar epidural anaesthesia. Br J Anaesth 2001; 86: 794-7
    • (2001) Br J Anaesth , vol.86 , pp. 794-797
    • Leather, H.1    Wouters, P.2
  • 7
    • 41049087999 scopus 로고    scopus 로고
    • Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: A comparison among LiDCO, transesophageal echocardiography, and pulmonary artery catheter
    • Belloni L, PisanoA,NataleA, et al.Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal echocardiography, and pulmonary artery catheter. J Cardiothorac Vasc Anesth 2008; 22: 243-8
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 243-248
    • Belloni, L.1    Pisano, A.2    Natale, A.3
  • 8
    • 79956351971 scopus 로고    scopus 로고
    • The effects of vasoactive drugs on pulse pressure and stroke volume variation in postoperative ventilated patients
    • Hadian M, Severyn D, Pinsky M. The effects of vasoactive drugs on pulse pressure and stroke volume variation in postoperative ventilated patients. J Crit Care 2010; 3: 328.e1-8
    • (2010) J Crit Care , vol.3
    • Hadian, M.1    Severyn, D.2    Pinsky, M.3
  • 9
    • 77953589373 scopus 로고    scopus 로고
    • The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery
    • Wyffels P, Sergeant P, Wouters P. The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery. Anaesthesia 2010; 65: 704-9
    • (2010) Anaesthesia , vol.65 , pp. 704-709
    • Wyffels, P.1    Sergeant, P.2    Wouters, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.