메뉴 건너뛰기




Volumn 39, Issue , 2012, Pages 305-308

Differences in intracardiac signals on a realistic catheter geometry using mono- and bidomain models

Author keywords

[No Author keywords available]

Indexed keywords

CARDIAC ARRHYTHMIA; EXTRACELLULAR POTENTIAL; INTRACARDIAC ELECTROGRAMS; MONODOMAIN SIMULATION; SIMULATION STUDIES; SUBSTRATE MODIFICATIONS; TRANSMEMBRANE VOLTAGE; WAVE-FRONT CURVATURE;

EID: 84875642434     PISSN: 23258861     EISSN: 2325887X     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (6)

References (9)
  • 1
    • 65649103735 scopus 로고    scopus 로고
    • Genesis of complex fractionated atrial electrograms in zones of slow conduction: A computer model of microfibrosis
    • Jun
    • Jacquemet V, Henriquez CS. Genesis of complex fractionated atrial electrograms in zones of slow conduction: a computer model of microfibrosis. Heart Rhythm Jun 2009; 6(6):803-10.
    • (2009) Heart Rhythm , vol.6 , Issue.6 , pp. 803-810
    • Jacquemet, V.1    Henriquez, C.S.2
  • 2
  • 3
    • 33947531586 scopus 로고    scopus 로고
    • Computer simulation of intracardiac potential with whole-heart model
    • Zhu X,Wei D. Computer simulation of intracardiac potential with whole-heart model. Int J Bioinform Res Appl 2007; 3(1):100-22.
    • (2007) Int J Bioinform Res Appl , vol.3 , Issue.1 , pp. 100-122
    • Zhu, X.1    Wei, D.2
  • 4
    • 77956195320 scopus 로고    scopus 로고
    • Local unipolar and bipolar electrogram criteria for evaluating the transmurality of atrial ablation lesions at different catheter orientations relative to the endocardial surface
    • Sep
    • Otomo K, Uno K, Fujiwara H, Isobe M, Iesaka Y. Local unipolar and bipolar electrogram criteria for evaluating the transmurality of atrial ablation lesions at different catheter orientations relative to the endocardial surface. Heart Rhythm Sep 2010;7(9):1291-300.
    • (2010) Heart Rhythm , vol.7 , Issue.9 , pp. 1291-1300
    • Otomo, K.1    Uno, K.2    Fujiwara, H.3    Isobe, M.4    Iesaka, Y.5
  • 5
    • 79955370283 scopus 로고    scopus 로고
    • Recording and interpreting unipolar electrograms to guide catheter ablation
    • May
    • Tedrow UB, Stevenson WG. Recording and interpreting unipolar electrograms to guide catheter ablation. Heart Rhythm May 2011;8(5):791-6.
    • (2011) Heart Rhythm , vol.8 , Issue.5 , pp. 791-796
    • Tedrow, U.B.1    Stevenson, W.G.2
  • 7
    • 0027234741 scopus 로고
    • Potential distributions generated by point stimulation in a myocardial volume: Simulation studies in a model of anisotropic ventricular muscle
    • Colli Franzone P, Guerri L, Taccardi B. Potential distributions generated by point stimulation in a myocardial volume: simulation studies in a model of anisotropic ventricular muscle. Journal of Cardiovascular Electrophysiology 1993; 4:438-458.
    • (1993) Journal of Cardiovascular Electrophysiology , vol.4 , pp. 438-458
    • Colli Franzone, P.1    Guerri, L.2    Taccardi, B.3
  • 8
    • 33750856807 scopus 로고    scopus 로고
    • Ionic mechanisms underlying human atrial action potential properties: Insights from a mathematical model
    • Courtemanche M, Ramirez RJ, Nattel S. Ionic mechanisms underlying human atrial action potential properties: Insights from a mathematical model. Am J Physiol 1998;275:H301-H321.
    • (1998) Am J Physiol , vol.275
    • Courtemanche, M.1    Ramirez, R.J.2    Nattel, S.3
  • 9
    • 0036932840 scopus 로고    scopus 로고
    • Fiberglass needle electrodes for transmural cardiac mapping
    • dec ISSN 0018-9294
    • Rogers J, Melnick S, Huang J. Fiberglass needle electrodes for transmural cardiac mapping. Biomedical Engineering IEEE Transactions on dec. 2002;49(12):1639-1641. ISSN 0018-9294.
    • (2002) Biomedical Engineering IEEE Transactions on , vol.49 , Issue.12 , pp. 1639-1641
    • Rogers, J.1    Melnick, S.2    Huang, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.