메뉴 건너뛰기




Volumn 267, Issue 1, 2013, Pages 201-211

Accuracy and reliability assessment of CT and MR perfusion analysis software using a digital phantom

Author keywords

[No Author keywords available]

Indexed keywords

3 (4,5 DIMETHYL 2 THIAZOLYL) 2,5 DIPHENYLTETRAZOLIUM BROMIDE; TRACER;

EID: 84875473343     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.12112618     Document Type: Article
Times cited : (125)

References (22)
  • 1
    • 0344417098 scopus 로고    scopus 로고
    • Perfusion measurements of the brain: Using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke
    • Klotz E, König M. Perfusion measurements of the brain: using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke. Eur J Radiol 1999;30(3):170-184.
    • (1999) Eur J Radiol , vol.30 , Issue.3 , pp. 170-184
    • Klotz, E.1    König, M.2
  • 2
    • 0033832227 scopus 로고    scopus 로고
    • Dynamic CT perfusion imaging of acute stroke
    • Mayer TE, Hamann GF, Baranczyk J, et al. Dynamic CT perfusion imaging of acute stroke. AJNR Am J Neuroradiol 2000;21(8): 1441-1449.
    • (2000) AJNR Am J Neuroradiol , vol.21 , Issue.8 , pp. 1441-1449
    • Mayer, T.E.1    Hamann, G.F.2    Baranczyk, J.3
  • 3
    • 0034820214 scopus 로고    scopus 로고
    • Utility of perfusion-weighted CT imaging in acute middle cerebral artery stroke treated with intra-arterial thrombolysis: Prediction of final infarct volume and clinical outcome
    • Lev MH, Segal AZ, Farkas J, et al. Utility of perfusion-weighted CT imaging in acute middle cerebral artery stroke treated with intra-arterial thrombolysis: prediction of final infarct volume and clinical outcome. Stroke 2001;32(9):2021-2028.
    • (2001) Stroke , vol.32 , Issue.9 , pp. 2021-2028
    • Lev, M.H.1    Segal, A.Z.2    Farkas, J.3
  • 5
    • 33745914647 scopus 로고    scopus 로고
    • Dynamic CT perfusion imaging in subarachnoid hemorrhage-related vasospasm
    • Laslo AM, Eastwood JD, Chen FX, Lee TY. Dynamic CT perfusion imaging in subarachnoid hemorrhage-related vasospasm. AJNR Am J Neuroradiol 2006;27(3):624-631.
    • (2006) AJNR Am J Neuroradiol , vol.27 , Issue.3 , pp. 624-631
    • Laslo, A.M.1    Eastwood, J.D.2    Chen, F.X.3    Lee, T.Y.4
  • 6
    • 0034069356 scopus 로고    scopus 로고
    • CT method to measure hemodynamics in brain tumors: Validation and application of cerebral blood flow maps
    • Cenic A, Nabavi DG, Craen RA, Gelb AW, Lee TY. A CT method to measure hemodynamics in brain tumors: validation and application of cerebral blood flow maps. AJNR Am J Neuroradiol 2000;21(3):462-470.
    • (2000) AJNR Am J Neuroradiol , vol.21 , Issue.3 , pp. 462-470
    • Cenic, A.1    Nabavi, D.G.2    Craen, R.A.3    Gelb, A.W.4    Lee, T.Y.A.5
  • 7
    • 60549114678 scopus 로고    scopus 로고
    • Optimal Tmax threshold for predicting penumbral tissue in acute stroke
    • Olivot JM, Mlynash M, Thijs VN, et al. Optimal Tmax threshold for predicting penumbral tissue in acute stroke. Stroke 2009; 40(2):469-475.
    • (2009) Stroke , vol.40 , Issue.2 , pp. 469-475
    • Olivot, J.M.1    Mlynash, M.2    Thijs, V.N.3
  • 8
    • 1642495953 scopus 로고    scopus 로고
    • Advances in penumbra imaging with MR
    • Davis SM, Donnan GA. Advances in penumbra imaging with MR. Cerebrovasc Dis 2004; 17(Suppl 3):23-27.
    • (2004) Cerebrovasc Dis , vol.17 , Issue.SUPPL. 3 , pp. 23-27
    • Davis, S.M.1    Donnan, G.A.2
  • 9
    • 7644223653 scopus 로고    scopus 로고
    • Improved prediction of final infarct volume using bolus delay-corrected perfusion-weighted MRI: Implications for the ischemic penumbra
    • Rose SE, Janke AL, Griffin M, Finnigan S, Chalk JB. Improved prediction of final infarct volume using bolus delay-corrected perfusion-weighted MRI: implications for the ischemic penumbra. Stroke 2004;35(11): 2466-2471.
    • (2004) Stroke , vol.35 , Issue.11 , pp. 2466-2471
    • Rose, S.E.1    Janke, A.L.2    Griffin, M.3    Finnigan, S.4    Chalk, J.B.5
  • 10
    • 79551620370 scopus 로고    scopus 로고
    • Prediction of infarct volume and neurologic outcome by using automated multiparametric perfusion-weighted magnetic resonance imaging in a primate model of permanent middle cerebral artery occlusion
    • Sasaki M, Kudo K, Honjo K, Hu JQ, Wang HB, Shintaku K. Prediction of infarct volume and neurologic outcome by using automated multiparametric perfusion-weighted magnetic resonance imaging in a primate model of permanent middle cerebral artery occlusion. J Cereb Blood Flow Metab 2011;31(2): 448-456.
    • (2011) J Cereb Blood Flow Metab , vol.31 , Issue.2 , pp. 448-456
    • Sasaki, M.1    Kudo, K.2    Honjo, K.3    Hu, J.Q.4    Wang, H.B.5    Shintaku, K.6
  • 11
    • 64949185294 scopus 로고    scopus 로고
    • Difference in tracer delay-induced effect among deconvolution algorithms in CT perfusion analysis: Quantitative evaluation with digital phantoms
    • Kudo K, Sasaki M, Ogasawara K, Terae S, Ehara S, Shirato H. Difference in tracer delay-induced effect among deconvolution algorithms in CT perfusion analysis: quantitative evaluation with digital phantoms. Radiology 2009;251(1):241-249.
    • (2009) Radiology , vol.251 , Issue.1 , pp. 241-249
    • Kudo, K.1    Sasaki, M.2    Ogasawara, K.3    Terae, S.4    Ehara, S.5    Shirato, H.6
  • 12
    • 75349087858 scopus 로고    scopus 로고
    • Differences in CT perfusion maps generated by different commercial software: Quantitative analysis by using identical source data of acute stroke patients
    • Kudo K, Sasaki M, Yamada K, et al. Differences in CT perfusion maps generated by different commercial software: quantitative analysis by using identical source data of acute stroke patients. Radiology 2010; 254(1):200-209.
    • (2010) Radiology , vol.254 , Issue.1 , pp. 200-209
    • Kudo, K.1    Sasaki, M.2    Yamada, K.3
  • 13
    • 66849106746 scopus 로고    scopus 로고
    • Comparison of 10 perfusion MRI parameters in 97 sub-6-hour stroke patients using voxel-based receiver operating characteristics analysis
    • Christensen S, Mouridsen K, Wu O, et al. Comparison of 10 perfusion MRI parameters in 97 sub-6-hour stroke patients using voxel-based receiver operating characteristics analysis. Stroke 2009;40(6):2055-2061.
    • (2009) Stroke , vol.40 , Issue.6 , pp. 2055-2061
    • Christensen, S.1    Mouridsen, K.2    Wu, O.3
  • 14
    • 80052557320 scopus 로고    scopus 로고
    • Computed tomography and magnetic resonance perfusion imaging in ischemic stroke: Definitions and thresholds
    • Dani KA, Thomas RG, Chappell FM, et al. Computed tomography and magnetic resonance perfusion imaging in ischemic stroke: definitions and thresholds. Ann Neurol 2011; 70(3):384-401.
    • (2011) Ann Neurol , vol.70 , Issue.3 , pp. 384-401
    • Dani, K.A.1    Thomas, R.G.2    Chappell, F.M.3
  • 15
    • 44449089055 scopus 로고    scopus 로고
    • Acute stroke imaging research roadmap
    • Wintermark M, Albers GW, Alexandrov AV, et al. Acute stroke imaging research roadmap. Stroke 2008;39(5):1621-1628.
    • (2008) Stroke , vol.39 , Issue.5 , pp. 1621-1628
    • Wintermark, M.1    Albers, G.W.2    Alexandrov, A.V.3
  • 16
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. I. Mathematical approach and statistical analysis
    • Ostergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. I. Mathematical approach and statistical analysis. Magn Reson Med 1996;36(5):715-725.
    • (1996) Magn Reson Med , vol.36 , Issue.5 , pp. 715-725
    • Ostergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 17
    • 0037587219 scopus 로고    scopus 로고
    • Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix
    • Wu O, østergaard L, Weisskoff RM, Benner T, Rosen BR, Sorensen AG. Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix. Magn Reson Med 2003;50(1):164-174.
    • (2003) Magn Reson Med , vol.50 , Issue.1 , pp. 164-174
    • Wu, O.1    Østergaard, L.2    Weisskoff, R.M.3    Benner, T.4    Rosen, B.R.5    Sorensen, A.G.6
  • 18
    • 77049181625 scopus 로고
    • On the theory of the indicator- dilution method for measurement of blood flow and volume
    • Meier P, Zierler KL. On the theory of the indicator- dilution method for measurement of blood flow and volume. J Appl Physiol 1954; 6(12):731-744.
    • (1954) J Appl Physiol , vol.6 , Issue.12 , pp. 731-744
    • Meier, P.1    Zierler, K.L.2
  • 19
    • 40949161352 scopus 로고    scopus 로고
    • Effects of alteplase beyond 3 h after stroke in the Echoplanar Imaging Thrombolytic Evaluation Trial (EPITHET): A placebo-controlled randomised trial
    • Davis SM, Donnan GA, Parsons MW, et al. Effects of alteplase beyond 3 h after stroke in the Echoplanar Imaging Thrombolytic Evaluation Trial (EPITHET): a placebo-controlled randomised trial. Lancet Neurol 2008; 7(4):299-309.
    • (2008) Lancet Neurol , vol.7 , Issue.4 , pp. 299-309
    • Davis, S.M.1    Donnan, G.A.2    Parsons, M.W.3
  • 20
    • 78349256704 scopus 로고    scopus 로고
    • Realtime diffusion-perfusion mismatch analysis in acute stroke
    • Straka M, Albers GW, Bammer R. Realtime diffusion-perfusion mismatch analysis in acute stroke. J Magn Reson Imaging 2010; 32(5):1024-1037.
    • (2010) J Magn Reson Imaging , vol.32 , Issue.5 , pp. 1024-1037
    • Straka, M.1    Albers, G.W.2    Bammer, R.3
  • 21
    • 77953132630 scopus 로고    scopus 로고
    • The physiological significance of the time-tomaximum (Tmax) parameter in perfusion MRI
    • Calamante F, Christensen S, Desmond PM, Ostergaard L, Davis SM, Connelly A. The physiological significance of the time-tomaximum (Tmax) parameter in perfusion MRI. Stroke 2010;41(6):1169-1174.
    • (2010) Stroke , vol.41 , Issue.6 , pp. 1169-1174
    • Calamante, F.1    Christensen, S.2    Desmond, P.M.3    Ostergaard, L.4    Davis, S.M.5    Connelly, A.6
  • 22
    • 33749267950 scopus 로고    scopus 로고
    • Bayesian estimation of cerebral perfusion using a physiological model of microvasculature
    • Mouridsen K, Friston K, Hjort N, Gyldensted L, østergaard L, Kiebel S. Bayesian estimation of cerebral perfusion using a physiological model of microvasculature. Neuroimage 2006;33(2):570-579.
    • (2006) Neuroimage , vol.33 , Issue.2 , pp. 570-579
    • Mouridsen, K.1    Friston, K.2    Hjort, N.3    Gyldensted, L.4    Østergaard, L.5    Kiebel, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.