메뉴 건너뛰기




Volumn 37, Issue 4, 2013, Pages 875-885

Dual-source parallel RF transmission for diffusion-weighted imaging of the abdomen using different b values: Image quality and apparent diffusion coefficient comparison with conventional single-source transmission

Author keywords

apparent diffusion coefficient; b values; diffusion weighted imaging; dual source parallel radiofrequency transmission; image quality; single source radiofrequency transmission

Indexed keywords

ABDOMINAL RADIOGRAPHY; ARTICLE; CONTROLLED STUDY; DIFFUSION COEFFICIENT; DIFFUSION WEIGHTED IMAGING; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; IMAGE QUALITY; INTERMETHOD COMPARISON; LIVER; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE SCANNER; PANCREAS; PRIORITY JOURNAL; PROSPECTIVE STUDY; QUANTITATIVE ANALYSIS; RADIOFREQUENCY; SIGNAL NOISE RATIO; SPLEEN;

EID: 84875468263     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.23869     Document Type: Article
Times cited : (11)

References (32)
  • 1
    • 34249874331 scopus 로고    scopus 로고
    • Diffusion-weighted MRI in the body: Applications and challenges in oncology
    • DOI 10.2214/AJR.06.1403
    • Koh D-M, Collins DJ,. Diffusion-weighted MRI in the body: applications and challenges in oncology. AJR Am J Roentgenol 2007; 188: 1622-1635. (Pubitemid 46866868)
    • (2007) American Journal of Roentgenology , vol.188 , Issue.6 , pp. 1622-1635
    • Koh, D.-M.1    Collins, D.J.2
  • 2
    • 34248671979 scopus 로고    scopus 로고
    • Extracranial applications of diffusion-weighted magnetic resonance imaging
    • DOI 10.1007/s00330-006-0547-0
    • Thoeny HC, De Keyzer F,. Extracranial applications of diffusion-weighted magnetic resonance imaging. Eur Radiol 2007; 17: 1385-1393. (Pubitemid 46767586)
    • (2007) European Radiology , vol.17 , Issue.6 , pp. 1385-1393
    • Thoeny, H.C.1    Keyzer, F.2
  • 3
    • 70349883871 scopus 로고    scopus 로고
    • Diffusion-weighted MRI provides additional value to conventional dynamic contrast-enhanced MRI for detection of hepatocellular carcinoma
    • Vandecaveye V, De Keyzer F, Verslype C, et al. Diffusion-weighted MRI provides additional value to conventional dynamic contrast-enhanced MRI for detection of hepatocellular carcinoma. Eur Radiol 2009; 19: 2456-2466.
    • (2009) Eur Radiol , vol.19 , pp. 2456-2466
    • Vandecaveye, V.1    De Keyzer, F.2    Verslype, C.3
  • 4
    • 40949092665 scopus 로고    scopus 로고
    • Focal liver lesion detection and characterization with diffusion-weighted MR imaging: Comparison with standard breath-hold T2-weighted imaging
    • Parikh T, Drew SJ, Lee VS, et al. Focal liver lesion detection and characterization with diffusion-weighted MR imaging: comparison with standard breath-hold T2-weighted imaging. Radiology 2008; 246: 812-822.
    • (2008) Radiology , vol.246 , pp. 812-822
    • Parikh, T.1    Drew, S.J.2    Lee, V.S.3
  • 5
    • 33646149774 scopus 로고    scopus 로고
    • Early response of hepatocellular carcinoma to transcatheter arterial chemoembolization: Choline levels and MR diffusion constants - Initial experience
    • Chen CY, Li CW, Kuo YT, et al. Early response of hepatocellular carcinoma to transcatheter arterial chemoembolization: choline levels and MR diffusion constants-initial experience. Radiology 2006; 239: 448-456.
    • (2006) Radiology , vol.239 , pp. 448-456
    • Chen, C.Y.1    Li, C.W.2    Kuo, Y.T.3
  • 7
    • 4143151590 scopus 로고    scopus 로고
    • High-b-value diffusion-weighted MR imaging for pretreatment prediction and early monitoring of tumor response to therapy in mice
    • DOI 10.1148/radiol.2322030778
    • Roth Y, Tichler T, Kostenich G, et al. High-b-value diffusion-weighted MR imaging for pretreatment prediction and early monitoring of tumor response to therapy in mice. Radiology 2004; 232: 685-692. (Pubitemid 39100249)
    • (2004) Radiology , vol.232 , Issue.3 , pp. 685-692
    • Roth, Y.1    Tichler, T.2    Kostenich, G.3    Ruiz-Cabello, J.4    Maier, S.E.5    Cohen, J.S.6    Orenstein, A.7    Mardor, Y.8
  • 8
    • 76349117868 scopus 로고    scopus 로고
    • Comparison between two-point and four-point methods for quantification of apparent diffusion coefficient of normal liver parenchyma and focal lesions: Value of normalization with spleen
    • Papanikolaou N, Gourtsoyianni S, Yarmenitis S, Maris T, Gourtsoyiannis N,. Comparison between two-point and four-point methods for quantification of apparent diffusion coefficient of normal liver parenchyma and focal lesions: value of normalization with spleen. Eur J Radiol 2010; 73: 305-309.
    • (2010) Eur J Radiol , vol.73 , pp. 305-309
    • Papanikolaou, N.1    Gourtsoyianni, S.2    Yarmenitis, S.3    Maris, T.4    Gourtsoyiannis, N.5
  • 9
    • 77956831157 scopus 로고    scopus 로고
    • Diagnosis of liver fibrosis and cirrhosis with diffusion-weighted imaging: Value of normalized apparent diffusion coefficient using the spleen as reference organ
    • Do RK, Chandarana H, Felker E, et al. Diagnosis of liver fibrosis and cirrhosis with diffusion-weighted imaging: value of normalized apparent diffusion coefficient using the spleen as reference organ. AJR Am J Roentgenol 2010; 195: 671-676.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 671-676
    • Do, R.K.1    Chandarana, H.2    Felker, E.3
  • 10
    • 55749097922 scopus 로고    scopus 로고
    • Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver
    • Kwee TC, Takahara T, Koh DM, Nievelstein RAJ, Luijten PR,. Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver. J Magn Reson Imaging 2008; 28: 1141-1148.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 1141-1148
    • Kwee, T.C.1    Takahara, T.2    Koh, D.M.3    Nievelstein, R.A.J.4    Luijten, P.R.5
  • 11
    • 84864686885 scopus 로고    scopus 로고
    • Reproductibility of apparent diffusion coefficients measurements in diffusion-weighted MRI of the abdomen with different b values
    • Bilgili MY,. Reproductibility of apparent diffusion coefficients measurements in diffusion-weighted MRI of the abdomen with different b values. Eur J Radiol 2012; 81: 2066-2068.
    • (2012) Eur J Radiol , vol.81 , pp. 2066-2068
    • Bilgili, M.Y.1
  • 12
    • 74949123772 scopus 로고    scopus 로고
    • Field strength and diffusion encoding technique affect the apparent diffusion coefficient measurements in diffusion-weighted imaging of the abdomen
    • Dale BM, Braithwaite AC, Boll DT, Merkle EM,. Field strength and diffusion encoding technique affect the apparent diffusion coefficient measurements in diffusion-weighted imaging of the abdomen. Invest Radiol 2010; 45: 104-108.
    • (2010) Invest Radiol , vol.45 , pp. 104-108
    • Dale, B.M.1    Braithwaite, A.C.2    Boll, D.T.3    Merkle, E.M.4
  • 14
    • 33744534543 scopus 로고    scopus 로고
    • Parallel RF transmission in MRI
    • DOI 10.1002/nbm.1049
    • Katscher U, Börnert P,. Parallel RF transmission in MRI. NMR Biomed 2006; 19: 393-400. (Pubitemid 43811112)
    • (2006) NMR in Biomedicine , vol.19 , Issue.3 , pp. 393-400
    • Katscher, U.1    Bornert, P.2
  • 15
    • 77956096409 scopus 로고    scopus 로고
    • Dual-source parallel radiofrequency excitation body MR imaging compared with standard MR imaging at 3.0 T: Initial clinical experience
    • Willinek WA, Gieseke J, Kukuk GM, et al. Dual-source parallel radiofrequency excitation body MR imaging compared with standard MR imaging at 3.0 T: initial clinical experience. Radiology 2010; 256: 966-975.
    • (2010) Radiology , vol.256 , pp. 966-975
    • Willinek, W.A.1    Gieseke, J.2    Kukuk, G.M.3
  • 16
    • 79955000146 scopus 로고    scopus 로고
    • Focal liver lesions at 3.0 T: Lesion detectability and image quality with T2-weighted imaging by using conventional and dual-source parallel radiofrequency transmission
    • Kukuk GM, Gieseke J, Weber S, et al. Focal liver lesions at 3.0 T: lesion detectability and image quality with T2-weighted imaging by using conventional and dual-source parallel radiofrequency transmission. Radiology 2011; 259: 421-428.
    • (2011) Radiology , vol.259 , pp. 421-428
    • Kukuk, G.M.1    Gieseke, J.2    Weber, S.3
  • 18
    • 1842586446 scopus 로고    scopus 로고
    • Parallel Excitation with an Array of Transmit Coils
    • DOI 10.1002/mrm.20011
    • Zhu Y,. Parallel excitation with an array of transmit coils. Magn Reson Med 2004; 51: 775-784. (Pubitemid 38420455)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.4 , pp. 775-784
    • Zhu, Y.1
  • 20
    • 36248932721 scopus 로고    scopus 로고
    • Noise measurement and estimation in MR imaging experiments
    • DOI 10.1148/radiol.2453062151
    • Heverhagen JT,. Noise measurement and estimation in MR imaging experiments. Radiology 2007; 245: 638-639. (Pubitemid 350127334)
    • (2007) Radiology , vol.245 , Issue.3 , pp. 638-639
    • Heverhagen, J.T.1
  • 21
    • 34248993972 scopus 로고    scopus 로고
    • Measurement of signal-to-noise ratio in MR imaging with sensitivity encoding
    • Moon WJ,. Measurement of signal-to-noise ratio in MR imaging with sensitivity encoding. Radiology 2007; 243: 908-909.
    • (2007) Radiology , vol.243 , pp. 908-909
    • Moon, W.J.1
  • 23
    • 44449139521 scopus 로고    scopus 로고
    • Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion
    • DOI 10.1002/jmri.21164
    • Franklin KM, Dale BM, Merkle EM,. Improvement in B1-inhomogeneity artifacts in the abdomen at 3T MR imaging using a radiofrequency cushion. J Magn Reson Imaging 2008; 27: 1443-1447. (Pubitemid 351770701)
    • (2008) Journal of Magnetic Resonance Imaging , vol.27 , Issue.6 , pp. 1443-1447
    • Franklin, K.M.1    Dale, B.M.2    Merkle, E.M.3
  • 24
    • 33646378436 scopus 로고    scopus 로고
    • Superparamagnetic iron oxide-enhanced liver magnetic resonance imaging: Comparison of 1.5 T and 3.0 T imaging for detection of focal malignant liver lesions
    • DOI 10.1097/01.rli.0000192417.33989.7a, PII 0000442420060200000015
    • Chang JM, Lee JM, Lee MW, et al. Superpara-magnetic iron oxide-enhanced liver magnetic resonance imaging: comparison of 1.5 T and 3.0 T imaging for detection of focal malignant liver lesions. Invest Radiol 2006; 41: 168-174. (Pubitemid 44406214)
    • (2006) Investigative Radiology , vol.41 , Issue.2 , pp. 168-174
    • Chang, J.M.1    Lee, J.M.2    Lee, M.W.3    Choi, J.Y.4    Kim, S.H.5    Lee, J.Y.6    Han, J.K.7    Choi, B.I.8
  • 25
    • 79957790742 scopus 로고    scopus 로고
    • Diffusion-weighted imaging of the abdomen at 3 T: Image quality comparison with 1.5-T magnet using 3 different imaging sequences
    • Saremi F, Jalili M, Sefidbakht S, et al. Diffusion-weighted imaging of the abdomen at 3 T: image quality comparison with 1.5-T magnet using 3 different imaging sequences. J Comput Assist Tomogr 2011; 35: 317-325.
    • (2011) J Comput Assist Tomogr , vol.35 , pp. 317-325
    • Saremi, F.1    Jalili, M.2    Sefidbakht, S.3
  • 26
    • 63849179148 scopus 로고    scopus 로고
    • Respiratory-triggered versus breath-hold diffusion-weighted MRI of liver lesions: Comparison of image quality and apparent diffusion coeffcient values
    • Kandpal H, Sharma R, Madhusudhan KS, Kapoor KS,. Respiratory-triggered versus breath-hold diffusion-weighted MRI of liver lesions: comparison of image quality and apparent diffusion coeffcient values. AJR Am J Roentgenol 2009; 192: 915-922.
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 915-922
    • Kandpal, H.1    Sharma, R.2    Madhusudhan, K.S.3    Kapoor, K.S.4
  • 27
    • 69449085107 scopus 로고    scopus 로고
    • Diffusion-weighted imaging of the liver: Comparison of navigator triggered and breathhold acquisitions
    • Taouli B, Sandberg A, Stemmer A, et al. Diffusion-weighted imaging of the liver: comparison of navigator triggered and breathhold acquisitions. J Magn Reson Imaging 2009; 30: 561-568.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 561-568
    • Taouli, B.1    Sandberg, A.2    Stemmer, A.3
  • 28
    • 0035105014 scopus 로고    scopus 로고
    • Noise correction for the exact determination of apparent diffusion coefficients at low SNR
    • DOI 10.1002/1522-2594(200103)45:3<448::AID-MRM1059>3.0.CO;2-W
    • Dietrich O, Heiland S, Sartor K,. Noise correction for the exact determination of apparent diffusion coefficients at low SNR. Magn Reson Med 2001; 45: 448-453. (Pubitemid 32173272)
    • (2001) Magnetic Resonance in Medicine , vol.45 , Issue.3 , pp. 448-453
    • Dietrich, O.1    Heiland, S.2    Sartor, K.3
  • 29
    • 33645514999 scopus 로고    scopus 로고
    • Influence of perfusion on hepatic MR diffusion measurement
    • Hollingsworth KG, Lomas DJ,. Influence of perfusion on hepatic MR diffusion measurement. NMR Biomed 2006; 19: 231-235.
    • (2006) NMR Biomed , vol.19 , pp. 231-235
    • Hollingsworth, K.G.1    Lomas, D.J.2
  • 31
    • 0031761816 scopus 로고    scopus 로고
    • Safety aspects of radiofrequency power deposition in magnetic resonance
    • Schaefer DJ,. Safety aspects of radio-frequency power deposition in magnetic resonance. Magn Reson Imaging Clin N Am 1998; 6: 775-789. (Pubitemid 28545968)
    • (1998) Magnetic Resonance Imaging Clinics of North America , vol.6 , Issue.4 , pp. 775-789
    • Schaefer, D.J.1
  • 32
    • 0033918247 scopus 로고    scopus 로고
    • Radiofrequency-induced heating during MR procedures: A review
    • Shellock FG,. Radiofrequency-induced heating during MR procedures: a review. J Magn Reson Imaging 2000; 12: 30-36.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 30-36
    • Shellock, F.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.