메뉴 건너뛰기




Volumn 41, Issue 4, 2013, Pages 419-424

Fetal head-symphysis distance: A simple and reliable ultrasound index of fetal head station in labor

Author keywords

fetal head symphysis distance; intrapartum; labor; three dimensional; translabial; ultrasound

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; COMPARATIVE STUDY; FEMALE; FETUS ECHOGRAPHY; HUMAN; LABOR STAGE 1; LABOR STAGE 2; METHODOLOGY; PALPATION; PHYSIOLOGY; PREGNANCY; REPRODUCIBILITY; THREE DIMENSIONAL IMAGING; TOMOGRAPHY; YOUNG ADULT; PROCEDURES;

EID: 84875456955     PISSN: 09607692     EISSN: 14690705     Source Type: Journal    
DOI: 10.1002/uog.12335     Document Type: Article
Times cited : (100)

References (27)
  • 1
    • 84875474576 scopus 로고    scopus 로고
    • Pelvic and fetal cranial anatomy and mechanism of labour
    • In, Warren R. Arulkumaran S. (eds). Cambridge University Press: New York, NY, 10.
    • Louis LS, Warren R,. Pelvic and fetal cranial anatomy and mechanism of labour. In Best Practice in Labour and Delivery, Warren R, Arulkumaran S, (eds). Cambridge University Press: New York, NY, 2009; 10.
    • (2009) Best Practice in Labour and Delivery
    • Louis, L.S.1    Warren, R.2
  • 2
    • 14644391527 scopus 로고    scopus 로고
    • Birth simulator: Reliability of transvaginal assessment of fetal head station as defined by the American College of Obstetricians and Gynecologists classification
    • Dupuis O, Silveira R, Zentner A, Dittmar A, Gaucherand P, Cucherat M, Redarce T, Rudigoz RC,. Birth simulator: reliability of transvaginal assessment of fetal head station as defined by the American College of Obstetricians and Gynecologists classification. Am J Obstet Gynecol 2005; 192: 868-874.
    • (2005) Am J Obstet Gynecol , vol.192 , pp. 868-874
    • Dupuis, O.1    Silveira, R.2    Zentner, A.3    Dittmar, A.4    Gaucherand, P.5    Cucherat, M.6    Redarce, T.7    Rudigoz, R.C.8
  • 3
    • 43049102345 scopus 로고    scopus 로고
    • Interobserver agreement in intrapartum estimation of fetal head station
    • Buchmann E, Libhaber E,. Interobserver agreement in intrapartum estimation of fetal head station. Int J Gynaecol Obstet 2008; 101: 285-289.
    • (2008) Int J Gynaecol Obstet , vol.101 , pp. 285-289
    • Buchmann, E.1    Libhaber, E.2
  • 5
    • 61849175427 scopus 로고    scopus 로고
    • Diagnosis of station and rotation of the fetal head in the second stage of labor with intrapartum translabial ultrasound
    • Ghi T, Farina A, Pedrazzi A, Rizzo N, Pelusi G, Pilu G,. Diagnosis of station and rotation of the fetal head in the second stage of labor with intrapartum translabial ultrasound. Ultrasound Obstet Gynecol 2009; 33: 331-336.
    • (2009) Ultrasound Obstet Gynecol , vol.33 , pp. 331-336
    • Ghi, T.1    Farina, A.2    Pedrazzi, A.3    Rizzo, N.4    Pelusi, G.5    Pilu, G.6
  • 7
    • 33751235254 scopus 로고    scopus 로고
    • Intrapartum translabial ultrasound (ITU): Sonographic landmarks and correlation with successful vacuum extraction
    • Henrich W, Dudenhausen J, Fuchs I, Kamena A, Tutschek B,. Intrapartum translabial ultrasound (ITU): sonographic landmarks and correlation with successful vacuum extraction. Ultrasound Obstet Gynecol 2006; 28: 753-760.
    • (2006) Ultrasound Obstet Gynecol , vol.28 , pp. 753-760
    • Henrich, W.1    Dudenhausen, J.2    Fuchs, I.3    Kamena, A.4    Tutschek, B.5
  • 9
    • 14544275016 scopus 로고    scopus 로고
    • Measuring engagement of the fetal head: Validity and reproducibility of a new ultrasound technique
    • Dietz HP, Lanzarone V,. Measuring engagement of the fetal head: validity and reproducibility of a new ultrasound technique. Ultrasound Obstet Gynecol 2005; 25: 165-168.
    • (2005) Ultrasound Obstet Gynecol , vol.25 , pp. 165-168
    • Dietz, H.P.1    Lanzarone, V.2
  • 10
    • 76249102734 scopus 로고    scopus 로고
    • Measurement of fetal head descent using the 'angle of progression' on transperineal ultrasound imaging is reliable regardless of fetal head station or ultrasound expertise
    • Duckelmann AM, Bamberg C, Michaelis SA, Lange J, Nonnenmacher A, Dudenhausen JW, Kalache KD,. Measurement of fetal head descent using the 'angle of progression' on transperineal ultrasound imaging is reliable regardless of fetal head station or ultrasound expertise. Ultrasound Obstet Gynecol 2010; 35: 216-222.
    • (2010) Ultrasound Obstet Gynecol , vol.35 , pp. 216-222
    • Duckelmann, A.M.1    Bamberg, C.2    Michaelis, S.A.3    Lange, J.4    Nonnenmacher, A.5    Dudenhausen, J.W.6    Kalache, K.D.7
  • 12
    • 78649536388 scopus 로고    scopus 로고
    • Three-dimensional ultrasound in monitoring progression of labor: A reproducibility study
    • Ghi T, Contro E, Farina A, Nobile M, Pilu G,. Three-dimensional ultrasound in monitoring progression of labor: a reproducibility study. Ultrasound Obstet Gynecol 2010; 36: 500-506.
    • (2010) Ultrasound Obstet Gynecol , vol.36 , pp. 500-506
    • Ghi, T.1    Contro, E.2    Farina, A.3    Nobile, M.4    Pilu, G.5
  • 13
    • 84857837712 scopus 로고    scopus 로고
    • Agreement between 2D and 3D transperineal ultrasound methods in assessing fetal head descent in the first stage of labour
    • Torkildsen EA, Salvesen KA, Eggebo TM,. Agreement between 2D and 3D transperineal ultrasound methods in assessing fetal head descent in the first stage of labour. Ultrasound Obstet Gynecol 2012; 39: 310-315.
    • (2012) Ultrasound Obstet Gynecol , vol.39 , pp. 310-315
    • Torkildsen, E.A.1    Salvesen, K.A.2    Eggebo, T.M.3
  • 16
    • 61849089434 scopus 로고    scopus 로고
    • Transperineal ultrasound imaging in prolonged second stage of labor with occipitoanterior presenting fetuses: How well does the 'angle of progression' predict the mode of delivery?
    • Kalache KD, Duckelmann AM, Michaelis SA, Lange J, Cichon G, Dudenhausen JW,. Transperineal ultrasound imaging in prolonged second stage of labor with occipitoanterior presenting fetuses: how well does the 'angle of progression' predict the mode of delivery? Ultrasound Obstet Gynecol 2009; 33: 326-330.
    • (2009) Ultrasound Obstet Gynecol , vol.33 , pp. 326-330
    • Kalache, K.D.1    Duckelmann, A.M.2    Michaelis, S.A.3    Lange, J.4    Cichon, G.5    Dudenhausen, J.W.6
  • 17
    • 0031849485 scopus 로고    scopus 로고
    • Reliability of assessment tools in rehabilitation: An illustration of appropriate statistical analyses
    • Rankin G, Stokes M,. Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses. Clin Rehabil 1998; 12: 187-199.
    • (1998) Clin Rehabil , vol.12 , pp. 187-199
    • Rankin, G.1    Stokes, M.2
  • 18
    • 0038675123 scopus 로고    scopus 로고
    • Applying the right statistics: Analyses of measurement studies
    • Bland JM, Altman DG,. Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol 2003; 22: 85-93.
    • (2003) Ultrasound Obstet Gynecol , vol.22 , pp. 85-93
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG,. Measuring agreement in method comparison studies. Stat Methods Med Res 1999; 8: 135-160.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 21
    • 0036229505 scopus 로고    scopus 로고
    • Intrapartum fetal head position I: Comparison between transvaginal digital examination and transabdominal ultrasound assessment during the active stage of labor
    • Sherer DM, Miodovnik M, Bradley KS, Langer O,. Intrapartum fetal head position I: comparison between transvaginal digital examination and transabdominal ultrasound assessment during the active stage of labor. Ultrasound Obstet Gynecol 2002; 19: 258-263.
    • (2002) Ultrasound Obstet Gynecol , vol.19 , pp. 258-263
    • Sherer, D.M.1    Miodovnik, M.2    Bradley, K.S.3    Langer, O.4
  • 22
    • 0036227776 scopus 로고    scopus 로고
    • Intrapartum fetal head position II: Comparison between transvaginal digital examination and transabdominal ultrasound assessment during the second stage of labor
    • Sherer DM, Miodovnik M, Bradley KS, Langer O,. Intrapartum fetal head position II: comparison between transvaginal digital examination and transabdominal ultrasound assessment during the second stage of labor. Ultrasound Obstet Gynecol 2002; 19: 264-268.
    • (2002) Ultrasound Obstet Gynecol , vol.19 , pp. 264-268
    • Sherer, D.M.1    Miodovnik, M.2    Bradley, K.S.3    Langer, O.4
  • 24
    • 69949088208 scopus 로고    scopus 로고
    • A question of angle of view
    • author reply 364-366.
    • Paltieli Y, Nizard J,. A question of angle of view. Ultrasound Obstet Gynecol 2009; 34: 363-364; author reply 364-366.
    • (2009) Ultrasound Obstet Gynecol , vol.34 , pp. 363-364
    • Paltieli, Y.1    Nizard, J.2
  • 25
    • 84863217200 scopus 로고    scopus 로고
    • Can sonographic depiction of fetal head position prior to or at the onset of labor predict mode of delivery?
    • Sherer DM,. Can sonographic depiction of fetal head position prior to or at the onset of labor predict mode of delivery? Ultrasound Obstet Gynecol 2012; 40: 1-6.
    • (2012) Ultrasound Obstet Gynecol , vol.40 , pp. 1-6
    • Sherer, D.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.