-
1
-
-
0001839273
-
Multislice x-ray CT scanner
-
Saito Y. Multislice x-ray CT scanner. Medical Rev. 1998;66:1-8.
-
(1998)
Medical Rev
, vol.66
, pp. 1-8
-
-
Saito, Y.1
-
2
-
-
0033452893
-
The effect of pitch in multislice spiral/helical CT
-
DOI 10.1118/1.598804
-
Wang G, Vannier MW. The effect of pitch in multislice spiral/helical CT. Med Phys. 1999;26:2648-2653. (Pubitemid 30007710)
-
(1999)
Medical Physics
, vol.26
, Issue.12
, pp. 2648-2653
-
-
Wang, G.1
Vannier, M.W.2
-
3
-
-
7944237119
-
Measurement accuracy of reconstructed 2-D images obtained by multi-slice helical computed tomography
-
DOI 10.1111/j.1600-0501.2004.01034.x
-
Naitoh M, Katsumata A, Nohara E, et al. Measurement accuracy of reconstructed 2-D images obtained by multislice helical computed tomography. Clin Oral Implants Res. 2004;15:570-574. (Pubitemid 40104952)
-
(2004)
Clinical Oral Implants Research
, vol.15
, Issue.5
, pp. 570-574
-
-
Naitoh, M.1
Katsumata, A.2
Nohara, E.3
Ohsaki, C.4
Ariji, E.5
-
4
-
-
0033156083
-
Development of a compact computed tomographic apparatus dental use
-
Arai Y, Tammisalo E, Iwai K, et al. Development of a compact computed tomographic apparatus dental use. Dentomaillofac Radiol. 1999;28:245-248.
-
(1999)
Dentomaillofac Radiol
, vol.28
, pp. 245-248
-
-
Arai, Y.1
Tammisalo, E.2
Iwai, K.3
-
5
-
-
33845571231
-
Imaging artifact and exposure conditions in limited-volume cone-beam computed tomography: Comparison between an image intensifier system and a flat panel detector
-
DOI 10.1007/s11282-006-0050-y
-
Naitoh M, Hirukawa A, Katsumata A, et al. Imaging artifact and exposure conditions in limited-volume cone-beam computed tomography: Comparison between an image intensifier system and a flat panel detector. Oral Radiol. 2006;22:69-74. (Pubitemid 44936221)
-
(2006)
Oral Radiology
, vol.22
, Issue.2
, pp. 69-74
-
-
Naitoh, M.1
Hirukawa, A.2
Katsumata, A.3
Saburi, K.4
Okumura, S.5
Ariji, E.6
-
7
-
-
67649213885
-
Observation of bifid mandibular canal using cone-beam computerized tomography
-
Naitoh M, Hiraiwa Y, Aimiya H, et al. Observation of bifid mandibular canal using cone-beam computerized tomography. Int J Oral Maxillofac Implants. 2009; 24:155-159.
-
(2009)
Int J Oral Maxillofac Implants
, vol.24
, pp. 155-159
-
-
Naitoh, M.1
Hiraiwa, Y.2
Aimiya, H.3
-
9
-
-
67649968263
-
Observation of buccal foramen in mandibular body using cone-beam computed tomography
-
Naitoh M, Nakahara K, Hiraiwa Y, et al. Observation of buccal foramen in mandibular body using cone-beam computed tomography. Okajimas Folia Anat Jpn. 2009;85:25-29.
-
(2009)
Okajimas Folia Anat Jpn
, vol.85
, pp. 25-29
-
-
Naitoh, M.1
Nakahara, K.2
Hiraiwa, Y.3
-
10
-
-
77953621536
-
Variations of bony canal in mandibular ramus using cone-beam computed tomography
-
Naitoh M, Nakahara K, Suenaga Y, et al. Variations of bony canal in mandibular ramus using cone-beam computed tomography. Oral Radiol. 2010:26: 36-40.
-
Oral Radiol
, vol.2010
, Issue.26
, pp. 36-40
-
-
Naitoh, M.1
Nakahara, K.2
Suenaga, Y.3
-
11
-
-
72049104773
-
Comparison between cone-beam and multislice computed tomography depicting mandibular neurovascular canal structures
-
Naitoh M, Nakahara K, Suenaga Y, et al. Comparison between cone-beam and multislice computed tomography depicting mandibular neurovascular canal structures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010;109:e25-e31.
-
(2010)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.109
-
-
Naitoh, M.1
Nakahara, K.2
Suenaga, Y.3
-
12
-
-
79952054729
-
Postoperative assessment of incisor dental implants using cone-beam computed tomography
-
Naitoh M, Nabeshima H, Hayashi H, et al. Postoperative assessment of incisor dental implants using cone-beam computed tomography. J Oral Implantol. 2010;36:377-384.
-
(2010)
J Oral Implantol
, vol.36
, pp. 377-384
-
-
Naitoh, M.1
Nabeshima, H.2
Hayashi, H.3
-
13
-
-
15044352366
-
OsiriX: An open-source software for navigating in multidimensional DICOM images
-
DOI 10.1007/s10278-004-1014-6
-
Rosset A, Spadola L, Ratib O. OsiriX: An open-source software for navigating in multidimensional DICOM images. J Digit Imaging. 2004;17:205-216. (Pubitemid 40378992)
-
(2004)
Journal of Digital Imaging
, vol.17
, Issue.3
, pp. 205-216
-
-
Rosset, A.1
Spadola, L.2
Ratib, O.3
-
14
-
-
64549109838
-
Evaluation of voxel values in mandibular cancellous bone: Relationship between cone-beam computed tomography and multislice helical computed tomography
-
Naitoh M, Hirukawa A, Katsumata A, et al. Evaluation of voxel values in mandibular cancellous bone: Relationship between cone-beam computed tomography and multislice helical computed tomography. Clin Oral Implants Res. 2009;20:503-506.
-
(2009)
Clin Oral Implants Res
, vol.20
, pp. 503-506
-
-
Naitoh, M.1
Hirukawa, A.2
Katsumata, A.3
-
16
-
-
0035261160
-
Bone classification: An objective scale of bone density using the computerized tomography scan
-
Norton MR, Gamble C. Bone classification: An objective scale of bone density using the computerized tomography scan. Clin Oral Implants Res. 2001;12: 79-84. (Pubitemid 33723216)
-
(2001)
Clinical Oral Implants Research
, vol.12
, Issue.1
, pp. 79-84
-
-
Norton, M.R.1
Gamble, C.2
-
18
-
-
2342425943
-
Measurement of mandibles with microfocus x-ray computerized tomography and compact computerized tomography for dental use
-
Naitoh M, Katsumata A, Mitsuya S, et al. Measurement of mandibles with microfocus x-ray computerized tomography and compact computerized tomography for dental use. Int J Oral Maxillofac Implants. 2004;19:239-246. (Pubitemid 38561062)
-
(2004)
International Journal of Oral and Maxillofacial Implants
, vol.19
, Issue.2
, pp. 239-246
-
-
Naitoh, M.1
Katsumata, A.2
Mitsuya, S.3
Kamemoto, H.4
Ariji, E.5
-
19
-
-
0003562121
-
The effective atomic number of the teeth
-
[Abstract in English]
-
Suzuki Y, Shimano T. The effective atomic number of the teeth. Dental Radiol. 1976;16:63-72. [Abstract in English].
-
(1976)
Dental Radiol
, vol.16
, pp. 63-72
-
-
Suzuki, Y.1
Shimano, T.2
-
20
-
-
33646650860
-
Development of bone substitute materials
-
[Abstract in English]
-
Hiraoka T, Kawashima K, Hoshino K, et al. Development of bone substitute materials. Radiother Syst Res. 1987;4: 93-96. [Abstract in English].
-
(1987)
Radiother Syst Res
, vol.4
, pp. 93-96
-
-
Hiraoka, T.1
Kawashima, K.2
Hoshino, K.3
-
21
-
-
67650170719
-
Relationship between cancellous bone density and mandibular canal depiction
-
Naitoh M, Hiraiwa Y, Kubota K, et al. Relationship between cancellous bone density and mandibular canal depiction. Implant Dent. 2009;18:112-119.
-
(2009)
Implant Dent
, vol.18
, pp. 112-119
-
-
Naitoh, M.1
Hiraiwa, Y.2
Kubota, K.3
|