Volumn 56, Issue SUPPL. 2, 2004, Pages 27-39

Reprocessing endoscopes: United States perspective

Author keywords

Cross infection; Disinfection; Endoscopes; Reprocessing

Indexed keywords

DISINFECTANT AGENT; PHTHALALDEHYDE; TAP WATER;

EID: 1942516358     PISSN: 01956701     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhin.2003.12.035     Document Type: Article
Times cited : (105)

References (149)
  • 1
    • 0034061282 scopus 로고    scopus 로고
    • Infectious complications associated with gastrointestinal endoscopy
    • Schembre D.B. Infectious complications associated with gastrointestinal endoscopy Gastrointest Endosc Clin N Am 10 2000 215-232
    • (2000) Gastrointest. Endosc. Clin. N. Am. , vol.10 , pp. 215-232
    • Schembre, D.B.1
  • 2
    • 0027076628 scopus 로고
    • Transmission of infection by gastrointestinal endoscopy and bronchoscopy
    • Spach D.H. Silverstein F.E. Stamm W.E. Transmission of infection by gastrointestinal endoscopy and bronchoscopy Ann Intern Med 118 1993 117-128
    • (1993) Ann. Intern. Med. , vol.118 , pp. 117-128
    • Spach, D.H.1    Silverstein, F.E.2    Stamm, W.E.3
  • 3
    • 0242568023 scopus 로고    scopus 로고
    • The prevention of infection following gastrointestinal endoscopy: The importance of prophylaxis and reprocessing
    • A. J. DiMarino, Jr. S. B. Benjamin Jr. (Eds.), Thorofare, NJ: Slack Inc
    • Weber D.J. Rutala W.A. DiMarino A.J. Jr The prevention of infection following gastrointestinal endoscopy: the importance of prophylaxis and reprocessing In: DiMarino A.J. Jr Benjamin S.B. (Eds.), Gastrointestinal diseases: an endoscopic approach 2002 87-106 Slack Inc Thorofare, NJ
    • (2002) Gastrointestinal Diseases: an Endoscopic Approach , pp. 87-106
    • Weber, D.J.1    Rutala, W.A.2    DiMarino Jr., A.J.3
  • 5
    • 0034062826 scopus 로고    scopus 로고
    • The microbial flora of the gastrointestinal tract and the cleaning of flexible endoscopes
    • Chu N.S. Favero M. The microbial flora of the gastrointestinal tract and the cleaning of flexible endoscopes Gastrointest Endosc Clin N Am 10 2000 233-244
    • (2000) Gastrointest. Endosc. Clin. N. Am. , vol.10 , pp. 233-244
    • Chu, N.S.1    Favero, M.2
  • 6
    • 0027954617 scopus 로고
    • In-hospital evaluation of orthophthaladehyde as a high level disinfectant for flexible endoscopes
    • Alfa M.J. Sitter D.L. In-hospital evaluation of orthophthaladehyde as a high level disinfectant for flexible endoscopes J Hosp Infect 26 1994 15-26
    • (1994) J. Hosp. Infect. , vol.26 , pp. 15-26
    • Alfa, M.J.1    Sitter, D.L.2
  • 7
    • 0033085123 scopus 로고    scopus 로고
    • Microbial bioburden in endoscope reprocessing and an in-use evaluation of the high-level disinfection capabilities of Cidex PA
    • Vesley D. Melson J. Stanley P. Microbial bioburden in endoscope reprocessing and an in-use evaluation of the high-level disinfection capabilities of Cidex PA Gastroenterol Nurs 22 1999 63-68
    • (1999) Gastroenterol. Nurs. , vol.22 , pp. 63-68
    • Vesley, D.1    Melson, J.2    Stanley, P.3
  • 8
    • 0031841571 scopus 로고    scopus 로고
    • Natural bioburden levels detected on flexible gastrointestinal endoscopes after clinical use and manual cleaning
    • Chu N.S. McAlister D. Antonoplos P.A. Natural bioburden levels detected on flexible gastrointestinal endoscopes after clinical use and manual cleaning Gastrointest Endosc 48 1998 137-142
    • (1998) Gastrointest. Endosc. , vol.48 , pp. 137-142
    • Chu, N.S.1    McAlister, D.2    Antonoplos, P.A.3
  • 9
    • 0029283682 scopus 로고
    • FDA labeling requirements for disinfection of endoscopes: A counterpoint
    • Rutala W.A. Weber D.J. FDA labeling requirements for disinfection of endoscopes: a counterpoint Infect Control Hosp Epidemiol 16 1995 231-235
    • (1995) Infect. Control Hosp. Epidemiol. , vol.16 , pp. 231-235
    • Rutala, W.A.1    Weber, D.J.2
  • 11
    • 0032862918 scopus 로고    scopus 로고
    • Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning
    • Alfa M.J. Degagne P. Olson N. Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning Am J Infect Control 27 1999 392-401
    • (1999) Am. J. Infect. Control , vol.27 , pp. 392-401
    • Alfa, M.J.1    Degagne, P.2    Olson, N.3
  • 12
    • 0032975663 scopus 로고    scopus 로고
    • High-level disinfection of gastrointestinal endoscopes: Are current guidelines adequate?
    • Kovacs B.J. Chen Y.K. Kettering J.D. Aprecio R.M. Roy I. High-level disinfection of gastrointestinal endoscopes: are current guidelines adequate? Am J Gastroenterol 94 1999 1546-1550
    • (1999) Am. J. Gastroenterol. , vol.94 , pp. 1546-1550
    • Kovacs, B.J.1    Chen, Y.K.2    Kettering, J.D.3    Aprecio, R.M.4    Roy, I.5
  • 14
    • 0029078894 scopus 로고
    • Endoscope decontamination: Where do we go from here?
    • Babb J.R. Bradley C.R. Endoscope decontamination: where do we go from here? J Hosp Infect 30 1995 543-551
    • (1995) J. Hosp. Infect. , vol.30 , pp. 543-551
    • Babb, J.R.1    Bradley, C.R.2
  • 15
    • 0024339809 scopus 로고
    • Contamination of endoscopes used in AIDS patients
    • Hanson P.J. Gor D. Clarke J.R. et al. Contamination of endoscopes used in AIDS patients Lancet 2 1989 86-88
    • (1989) Lancet , vol.2 , pp. 86-88
    • Hanson, P.J.1    Gor, D.2    Clarke, J.R.3
  • 16
    • 0025810359 scopus 로고
    • Recovery of the human immunodeficiency virus from fiberoptic bronchoscopes
    • Hanson P.J. Gor D. Clarke J.R. et al. Recovery of the human immunodeficiency virus from fiberoptic bronchoscopes Thorax 46 1991 410-412
    • (1991) Thorax , vol.46 , pp. 410-412
    • Hanson, P.J.1    Gor, D.2    Clarke, J.R.3
  • 17
    • 0032817251 scopus 로고    scopus 로고
    • Evaluation of disinfection and sterilization of reusable angioscopes with the duck hepatitis B model
    • Chaufour X. Deva A.K. Vickery K. et al. Evaluation of disinfection and sterilization of reusable angioscopes with the duck hepatitis B model J Vasc Surg 30 1999 277-282
    • (1999) J. Vasc. Surg. , vol.30 , pp. 277-282
    • Chaufour, X.1    Deva, A.K.2    Vickery, K.3
  • 18
    • 0032607540 scopus 로고    scopus 로고
    • Disinfection of endoscopes: Review of new chemical sterilants used for high-level disinfection
    • Rutala W.A. Weber D.J. Disinfection of endoscopes: review of new chemical sterilants used for high-level disinfection Infect Control Hosp Epidemiol 20 1999 69-76
    • (1999) Infect. Control Hosp. Epidemiol. , vol.20 , pp. 69-76
    • Rutala, W.A.1    Weber, D.J.2
  • 20
    • 58149204972 scopus 로고    scopus 로고
    • Position statement: Reprocessing of flexible gastrointestinal endoscopes
    • American Society for Gastrointestinal Endoscopy
    • American Society for Gastrointestinal Endoscopy Position statement: reprocessing of flexible gastrointestinal endoscopes Gastrointest Endosc 43 1996 541-546
    • (1996) Gastrointest. Endosc. , vol.43 , pp. 541-546
  • 22
    • 0031861889 scopus 로고    scopus 로고
    • Risk of contamination of sterile biopsy forceps in disinfected endoscopes
    • Lee R.M. Kozarek R.A. Sumida S.E. Raltz S.L. Risk of contamination of sterile biopsy forceps in disinfected endoscopes Gastrointest Endosc 47 1998 377-381
    • (1998) Gastrointest. Endosc. , vol.47 , pp. 377-381
    • Lee, R.M.1    Kozarek, R.A.2    Sumida, S.E.3    Raltz, S.L.4
  • 23
    • 0034008710 scopus 로고    scopus 로고
    • APIC guideline for infection prevention and control in flexible endoscopy. Association for Professionals in infection Control
    • Alvarado C.J. Reichelderfer M. APIC guideline for infection prevention and control in flexible endoscopy. Association for Professionals in infection Control Am J Infect Control 28 2000 138-155
    • (2000) Am. J. Infect Control , vol.28 , pp. 138-155
    • Alvarado, C.J.1    Reichelderfer, M.2
  • 24
    • 0034231549 scopus 로고    scopus 로고
    • Guidelines for the use of high-level disinfectants and sterilants for reprocessing of flexible gastrointestinal endoscopes
    • Society of Gastroenterology Nurses and Associates
    • Society of Gastroenterology Nurses and Associates Guidelines for the use of high-level disinfectants and sterilants for reprocessing of flexible gastrointestinal endoscopes Gastroenterol Nurs 23 2000 180-187
    • (2000) Gastroenterol. Nurs. , vol.23 , pp. 180-187
  • 25
    • 0034231418 scopus 로고    scopus 로고
    • Standards for infection control and reprocessing of flexible gastrointestinal endoscopes
    • Society of Gastroenterology Nurses and Associates
    • Society of Gastroenterology Nurses and Associates Standards for infection control and reprocessing of flexible gastrointestinal endoscopes Gastroenterol Nurs 23 2000 172-179
    • (2000) Gastroenterol. Nurs. , vol.23 , pp. 172-179
  • 26
    • 0042706408 scopus 로고    scopus 로고
    • Multi-society guideline for reprocessing flexible gastrointestinal endoscopes
    • Nelson D.B. Jarvis W.R. Rutala W.A. et al. Multi-society guideline for reprocessing flexible gastrointestinal endoscopes Infect Control Hosp Epidemiol 24 2003 532-537
    • (2003) Infect. Control Hosp. Epidemiol. , vol.24 , pp. 532-537
    • Nelson, D.B.1    Jarvis, W.R.2    Rutala, W.A.3
  • 27
    • 0025408763 scopus 로고
    • APIC guideline for selection and use of disinfectants
    • Rutala W.A. APIC guideline for selection and use of disinfectants Am J Infect Control 18 1990 99-117
    • (1990) Am. J. Infect. Control , vol.18 , pp. 99-117
    • Rutala, W.A.1
  • 28
    • 0028299318 scopus 로고
    • APIC guidelines for infection prevention and control in flexible endoscopy
    • 1991 and 1993 APIC Guidelines Committee
    • Martin M.A. Reichelderfer M. 1991 and 1993 APIC Guidelines Committee APIC guidelines for infection prevention and control in flexible endoscopy Am J Infect Control 22 1994 19-38
    • (1994) Am. J. Infect. Control , vol.22 , pp. 19-38
    • Martin, M.A.1    Reichelderfer, M.2
  • 30
    • 0033190727 scopus 로고    scopus 로고
    • Efficacy of conventional endoscopic disinfection and sterilization methods against Helicobacter pylori contamination
    • Cronmiller J.R. Nelson D.K. Jackson D.K. Kim C.H. Efficacy of conventional endoscopic disinfection and sterilization methods against Helicobacter pylori contamination Helicobacter 4 1999 198-203
    • (1999) Helicobacter , vol.4 , pp. 198-203
    • Cronmiller, J.R.1    Nelson, D.K.2    Jackson, D.K.3    Kim, C.H.4
  • 32
    • 0026482052 scopus 로고
    • A study of glutaraldehyde disinfection of fibreoptic bronchoscopes experimentally contaminated with Mycobacterium tuberculosis
    • Hanson P.J. Chadwick M.V. Gaya H. Collins J.V. A study of glutaraldehyde disinfection of fibreoptic bronchoscopes experimentally contaminated with Mycobacterium tuberculosis J Hosp Infect 22 1992 137-142
    • (1992) J. Hosp. Infect. , vol.22 , pp. 137-142
    • Hanson, P.J.1    Chadwick, M.V.2    Gaya, H.3    Collins, J.V.4
  • 33
    • 0036673594 scopus 로고    scopus 로고
    • Contamination of single-use biopsy forceps: A prospective in vitro analysis
    • Kinney T.P. Kozarek R.A. Raltz S. Attia F. Contamination of single-use biopsy forceps: a prospective in vitro analysis Gastrointest Endosc 56 2002 209-212
    • (2002) Gastrointest. Endosc. , vol.56 , pp. 209-212
    • Kinney, T.P.1    Kozarek, R.A.2    Raltz, S.3    Attia, F.4
  • 34
    • 0028237289 scopus 로고
    • Feasibility of a combined carrier test for disinfectants: Studies with a mixture of five types of miscoorganisms
    • Best M. Springthorpe V.S. Sattar S.A. Feasibility of a combined carrier test for disinfectants: studies with a mixture of five types of miscoorganisms Am J Infect Control 22 1994 152-162
    • (1994) Am. J. Infect. Control , vol.22 , pp. 152-162
    • Best, M.1    Springthorpe, V.S.2    Sattar, S.A.3
  • 35
    • 0029890078 scopus 로고    scopus 로고
    • Quality improvement in gastrointestinal endoscopy: Microbiologic surveillance of disinfection
    • Merighi A. Contato E. Scagliarini R. et al Quality improvement in gastrointestinal endoscopy: microbiologic surveillance of disinfection Gastrointest Endosc 43 1996 457-462
    • (1996) Gastrointest. Endosc. , vol.43 , pp. 457-462
    • Merighi, A.1    Contato, E.2    Scagliarini, R.3
  • 36
    • 0002950034 scopus 로고    scopus 로고
    • Endoscope reprocessing: Problems and solutions
    • W. A. Rutala (Ed.), Champlain, New York: Polyscience Publications
    • Bond W.W. Endoscope reprocessing: problems and solutions In: Rutala W.A. (Ed.), Disinfection, sterilization, and antisepsis in healthcare 1998 151-163 Polyscience Publications Champlain, New York
    • (1998) Disinfection, Sterilization, and Antisepsis in Healthcare , pp. 151-163
    • Bond, W.W.1
  • 37
    • 0030036054 scopus 로고    scopus 로고
    • Establishment of an in-use testing method for evaluating disinfection of surgical instruments using the duck hepatitis B model
    • Dava A.K. Vickery K. Zou J. West R.H. Harris J.P. Cossart Y.E. Establishment of an in-use testing method for evaluating disinfection of surgical instruments using the duck hepatitis B model J Hosp Infect 33 1996 119-130
    • (1996) J. Hosp. Infect. , vol.33 , pp. 119-130
    • Dava, A.K.1    Vickery, K.2    Zou, J.3    West, R.H.4    Harris, J.P.5    Cossart, Y.E.6
  • 38
    • 0025332955 scopus 로고
    • Elimination of high titre HIV from fibreoptic endoscopes
    • Hanson P.J. Gor D. Jeffries D.J. Collins J.V. Elimination of high titre HIV from fibreoptic endoscopes Gut 31 1990 657-659
    • (1990) Gut , vol.31 , pp. 657-659
    • Hanson, P.J.1    Gor, D.2    Jeffries, D.J.3    Collins, J.V.4
  • 39
    • 0030443931 scopus 로고    scopus 로고
    • Effective reduction of Helicobacter pylori infection after upper gastrointestinal endoscopy by mechanical washing of the endoscope
    • Wu M.S. Wang J.T. Yang J.C. et al. Effective reduction of Helicobacter pylori infection after upper gastrointestinal endoscopy by mechanical washing of the endoscope Hepatogastroenterology 43 1996 1660-1664
    • (1996) Hepatogastroenterology , vol.43 , pp. 1660-1664
    • Wu, M.S.1    Wang, J.T.2    Yang, J.C.3
  • 40
    • 0002164744 scopus 로고    scopus 로고
    • Environmental issues and nosocomial infections
    • R. P. Wenzel (Ed.), Baltimore: Williams and Wilkins
    • Weber D.J. Rutala W.A. Environmental issues and nosocomial infections In Wenzel R.P. (Ed.), Prevention and control of nosocomial infections 1997 491-514 Williams and Wilkins Baltimore
    • (1997) Prevention and Control of Nosocomial Infections , pp. 491-514
    • Weber, D.J.1    Rutala, W.A.2
  • 41
    • 0037448399 scopus 로고    scopus 로고
    • Pseudomonas aeruginosa and Serratia marcescens contamination associated with a manufacturing defect in bronchoscopes
    • Kirschke D.L. Jones T.F. Craig A.S. et al. Pseudomonas aeruginosa and Serratia marcescens contamination associated with a manufacturing defect in bronchoscopes N Engl J Med 348 2003 214-220
    • (2003) N. Engl. J. Med. , vol.348 , pp. 214-220
    • Kirschke, D.L.1    Jones, T.F.2    Craig, A.S.3
  • 42
    • 0037448354 scopus 로고    scopus 로고
    • An outbreak of Pseudomonas aeruginosa infections associated with flexible bronchoscopes
    • Srinivassan A. Wolfenden L.L. Song X et al. An outbreak of Pseudomonas aeruginosa infections associated with flexible bronchoscopes N Engl J Med 348 2003 221-227
    • (2003) N. Engl. J. Med. , vol.348 , pp. 221-227
    • Srinivassan, A.1    Wolfenden, L.L.2    Song, X.3
  • 43
    • 0026504895 scopus 로고
    • Multi-state investigation of the actual disinfection/sterilization of endoscopes in health care facilities
    • Kaczmarek R.G. Moore R.M. Jr McCrohan J. et al. Multi-state investigation of the actual disinfection/sterilization of endoscopes in health care facilities Am J Med 92 1992 257-261
    • (1992) Am. J. Med. , vol.92 , pp. 257-261
    • Kaczmarek, R.G.1    Moore Jr., R.M.2    McCrohan, J.3
  • 44
    • 0029034794 scopus 로고
    • Endoscope decontamination: Automated vs. manual
    • Bradley C.R. Babb J.R. Endoscope decontamination: automated vs. manual J Hosp Infect 30 1995 537-542
    • (1995) J. Hosp. Infect. , vol.30 , pp. 537-542
    • Bradley, C.R.1    Babb, J.R.2
  • 45
    • 0029783485 scopus 로고    scopus 로고
    • Advantages and limitations of automatic flexible endoscope reprocessors
    • Muscarella L.F. Advantages and limitations of automatic flexible endoscope reprocessors Am J Infect Control 24 1996 304-309
    • (1996) Am. J. Infect. Control , vol.24 , pp. 304-309
    • Muscarella, L.F.1
  • 47
    • 0025992682 scopus 로고
    • Noscomial infections from contaminated endoscopes: A flawed automated endoscope washer. An investigation using molecular epidemiology
    • Alvarado C.J. Stolz S.M. Maki D.G. Noscomial infections from contaminated endoscopes: a flawed automated endoscope washer. An investigation using molecular epidemiology Am J Med 91 1991 272S-280S
    • (1991) Am. J. Med. , vol.91
    • Alvarado, C.J.1    Stolz, S.M.2    Maki, D.G.3
  • 48
    • 0026562481 scopus 로고
    • Contamination of flexible fiberoptic bronchoscopes with Mycobacterium chelonae linked to an automated bronchoscope disinfection machine
    • Fraser V.J. Jones M. Murray P.R. Medoff G. Zhang Y. Wallace R.J. Jr Contamination of flexible fiberoptic bronchoscopes with Mycobacterium chelonae linked to an automated bronchoscope disinfection machine Am Rev Respir Dis 145 1992 853-855
    • (1992) Am. Rev. Respir. Dis. , vol.145 , pp. 853-855
    • Fraser, V.J.1    Jones, M.2    Murray, P.R.3    Medoff, G.4    Zhang, Y.5    Wallace Jr., R.J.6
  • 50
    • 0033626527 scopus 로고    scopus 로고
    • Deja Vu... All over again? The importance of instrument drying
    • Muscarella L.F. Deja Vu... All over again? The importance of instrument drying Infect Control Hosp Epidemiol 21 2000 628-629
    • (2000) Infect. Control Hosp. Epidemiol. , vol.21 , pp. 628-629
    • Muscarella, L.F.1
  • 51
    • 0033158386 scopus 로고    scopus 로고
    • Importance of lumen flow in liquid chemical sterilization
    • Rutala W.A. Weber D.J. Importance of lumen flow in liquid chemical sterilization Am J Infect Control 20 1999 458-459
    • (1999) Am. J. Infect. Control , vol.20 , pp. 458-459
    • Rutala, W.A.1    Weber, D.J.2
  • 53
    • 0024561826 scopus 로고
    • Bronchopulmonary cross-colonization and infection related to mycobacterial contamination of suction valves of bronchoscopes
    • Wheeler P.W. Lancaster D. Kaiser A.B. Bronchopulmonary cross-colonization and infection related to mycobacterial contamination of suction valves of bronchoscopes J Infect Dis 159 1989 954-958
    • (1989) J. Infect. Dis. , vol.159 , pp. 954-958
    • Wheeler, P.W.1    Lancaster, D.2    Kaiser, A.B.3
  • 54
    • 1942481542 scopus 로고
    • Virus transmission via fiberoptic endoscope: Recommended disinfection
    • Bond W.W. Virus transmission via fiberoptic endoscope: recommended disinfection JAMA 257 1987 843-844
    • (1987) JAMA , vol.257 , pp. 843-844
    • Bond, W.W.1
  • 55
    • 0027056737 scopus 로고
    • Evaluation of four commercial automatic endoscope washing machines
    • Lynch D.A. Porter C. Murphy L. Axon A.T. Evaluation of four commercial automatic endoscope washing machines Endoscopy 24 1992 766-770
    • (1992) Endoscopy , vol.24 , pp. 766-770
    • Lynch, D.A.1    Porter, C.2    Murphy, L.3    Axon, A.T.4
  • 56
    • 0025810483 scopus 로고
    • Disinfection and endoscopy: Microbial considerations
    • Bond W.W. Disinfection and endoscopy: microbial considerations J Gastroenterol Hepatol 6 1991 31-36
    • (1991) J. Gastroenterol. Hepatol. , vol.6 , pp. 31-36
    • Bond, W.W.1
  • 57
    • 0034104766 scopus 로고    scopus 로고
    • Newer technologies for endoscope disinfection: Electrolyzed acid water and disposable-component endoscope systems
    • Nelson D. Newer technologies for endoscope disinfection: electrolyzed acid water and disposable-component endoscope systems Gastrointest Endosc Clin N Am 10 2000 319-328
    • (2000) Gastrointest. Endosc. Clin. N. Am. , vol.10 , pp. 319-328
    • Nelson, D.1
  • 58
    • 0033628708 scopus 로고    scopus 로고
    • Guidelines on cleaning and disinfection in GI endoscopy. Update 1999. The European Society of Gastrointestinal Endoscopy
    • Kruse A. Rey J.F. Guidelines on cleaning and disinfection in GI endoscopy. Update 1999. The European Society of Gastrointestinal Endoscopy Endoscopy 32 2000 77-80
    • (2000) Endoscopy , vol.32 , pp. 77-80
    • Kruse, A.1    Rey, J.F.2
  • 59
    • 18844464904 scopus 로고    scopus 로고
    • British Thoracic Society guidelines on diagnostic flexible bronchoscopy
    • British Thoracic Society
    • British Thoracic Society British Thoracic Society guidelines on diagnostic flexible bronchoscopy Thorax 56 2001 1-21
    • (2001) Thorax , vol.56 , pp. 1-21
  • 60
    • 25944468716 scopus 로고    scopus 로고
    • Recommended practices for use and care of endoscopes. 2000 standards, recommended practices, and guidelines
    • Association of Operating Room Nurses Denver, CO: AORN
    • Association of Operating Room Nurses Recommended practices for use and care of endoscopes. 2000 standards, recommended practices, and guidelines 2000 AORN Denver, CO
    • (2000)
  • 61
    • 0031955527 scopus 로고    scopus 로고
    • Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a working party of the British Society of Gastroenterology Endoscope Committee
    • British Society of Gastroenterology of Gastroenterology Endoscope Committee
    • British Society of Gastroenterology Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a working party of the British Society of Gastroenterology Endoscope Committee Gut 42 1998 585-593
    • (1998) Gut , vol.42 , pp. 585-593
  • 62
    • 0031279659 scopus 로고    scopus 로고
    • Correction of deficiencies in flexible fiberoptic sigmoidoscope cleaning and disinfection technique in family practice and internal medicine offices
    • Jackson F.W. Ball M.D. Correction of deficiencies in flexible fiberoptic sigmoidoscope cleaning and disinfection technique in family practice and internal medicine offices Arch Fam Med 6 1997 578-582
    • (1997) Arch. Fam. Med. , vol.6 , pp. 578-582
    • Jackson, F.W.1    Ball, M.D.2
  • 63
    • 0030727650 scopus 로고    scopus 로고
    • Italian national survey of digestive endoscopy disinfection procedures
    • Orsi G.B. Filocamo A. Di Stefano L. Tittobello A. Italian national survey of digestive endoscopy disinfection procedures Endoscopy 29 1997 732-738
    • (1997) Endoscopy , vol.29 , pp. 732-738
    • Orsi, G.B.1    Filocamo, A.2    Di Stefano, L.3    Tittobello, A.4
  • 64
    • 0030870860 scopus 로고    scopus 로고
    • An audit of bronchoscopy practice in the United Kingdom: A survey of adherence to national guidelines
    • Honeybourne D. Neuman C.S. An audit of bronchoscopy practice in the United Kingdom: a survey of adherence to national guidelines Thorax 52 1997 709-713
    • (1997) Thorax , vol.52 , pp. 709-713
    • Honeybourne, D.1    Neuman, C.S.2
  • 65
    • 0030853783 scopus 로고    scopus 로고
    • Transmission of Mycobacterium tuberculosis by a fiberoptic bronchoscope. Identification by DNA fingerprinting
    • Michele T.M. Cronin W.A. Graham N.M. et al. Transmission of Mycobacterium tuberculosis by a fiberoptic bronchoscope. Identification by DNA fingerprinting JAMA 278 1997 1093-1095
    • (1997) JAMA , vol.278 , pp. 1093-1095
    • Michele, T.M.1    Cronin, W.A.2    Graham, N.M.3
  • 66
    • 0030764517 scopus 로고    scopus 로고
    • Patient-to-patient transmission of hepatitis C virus during colonoscopy
    • Bronowicki J.P. Venard V. Botte C. et al. Patient-to-patient transmission of hepatitis C virus during colonoscopy N Engl J Med 337 1997 237-240
    • (1997) N. Engl. J. Med. , vol.337 , pp. 237-240
    • Bronowicki, J.P.1    Venard, V.2    Botte, C.3
  • 67
    • 0030774748 scopus 로고    scopus 로고
    • Transmission of a highly drug-resistant strain (strain W1) of Mycobacterium tuberculosis. Community outbreak and nosocomical transmission via a contaminated bronchoscope
    • Agerton T. Valway S. Gore B. et al. Transmission of a highly drug-resistant strain (strain W1) of Mycobacterium tuberculosis. Community outbreak and nosocomical transmission via a contaminated bronchoscope JAMA 278 1997 1073-1077
    • (1997) JAMA , vol.278 , pp. 1073-1077
    • Agerton, T.1    Valway, S.2    Gore, B.3
  • 68
    • 0003644195 scopus 로고    scopus 로고
    • FDA and CDC public health advisory: Infections from endoscopes inadequately reprocessed by an automated endoscope reprocessing system
    • Food and Drug Administration, Centers for Disease Control and Prevention Rockville, MD: Food and Drug Administration
    • Food and Drug Administration, Centers for Disease Control and Prevention FDA and CDC public health advisory: infections from endoscopes inadequately reprocessed by an automated endoscope reprocessing system 1999 Food and Drug Administration Rockville, MD
    • (1999)
  • 69
    • 0036584425 scopus 로고    scopus 로고
    • Establishing the shelf life of flexible colonoscopes
    • Riley R. Beanland C. Bos H. Establishing the shelf life of flexible colonoscopes Gastroenterol Nurs 25 2002 114-119
    • (2002) Gastroenterol. Nurs. , vol.25 , pp. 114-119
    • Riley, R.1    Beanland, C.2    Bos, H.3
  • 70
    • 0036593170 scopus 로고    scopus 로고
    • Quality of final rinse water used in washer-disinfectors for endoscopes
    • Humphreys H. McGrath H. McCormick P.A. Walsh C. Quality of final rinse water used in washer-disinfectors for endoscopes J Hosp Infect 51 2002 151-153
    • (2002) J. Hosp. Infect. , vol.51 , pp. 151-153
    • Humphreys, H.1    McGrath, H.2    McCormick, P.A.3    Walsh, C.4
  • 71
    • 0019974257 scopus 로고
    • Cleaning and disinfection of fiberoptic endoscopes: Evaluation of glutaraldehyde exposure time and forced-air drying
    • Gerding D.N. Peterson L.R. Vennes J.A. Cleaning and disinfection of fiberoptic endoscopes: evaluation of glutaraldehyde exposure time and forced-air drying Gastroenterology 83 1982 613-618
    • (1982) Gastroenterology , vol.83 , pp. 613-618
    • Gerding, D.N.1    Peterson, L.R.2    Vennes, J.A.3
  • 73
    • 0037259558 scopus 로고    scopus 로고
    • Surveillance cultures to monitor quality of gastrointestinal endoscope reprocessing
    • Leung J. Vallero R. Wilson R. Surveillance cultures to monitor quality of gastrointestinal endoscope reprocessing Am J Gastroenterol 2003 98
    • (2003) Am. J. Gastroenterol. , pp. 98
    • Leung, J.1    Vallero, R.2    Wilson, R.3
  • 74
    • 0037256434 scopus 로고    scopus 로고
    • Surveillance cultures to monitor quality of gastrointestinal endoscope reprocessing
    • Moses F.M. Lee J. Surveillance cultures to monitor quality of gastrointestinal endoscope reprocessing Am J Gastroenterol 98 2003 77-81
    • (2003) Am. J. Gastroenterol. , vol.98 , pp. 77-81
    • Moses, F.M.1    Lee, J.2
  • 75
    • 0035999824 scopus 로고    scopus 로고
    • Application of environmental sampling to flexible endoscope reprocessing: The importance of monitoring the rinse water
    • Muscarella L.F. Application of environmental sampling to flexible endoscope reprocessing: the importance of monitoring the rinse water Infect Control Hosp Epidemiol 23 2002 285-289
    • (2002) Infect. Control Hosp. Epidemiol. , vol.23 , pp. 285-289
    • Muscarella, L.F.1
  • 76
  • 77
    • 3042756428 scopus 로고    scopus 로고
    • Guidelines for environmental infection control in health care facilities
    • Centers for Disease Control No. RR-10
    • Centers for Disease Control Guidelines for environmental infection control in health care facilities MMWR 52 No. RR-10 2003 1-44
    • (2003) MMWR , vol.52 , pp. 1-44
  • 79
    • 1942417519 scopus 로고    scopus 로고
    • Inactivated glutaraldehyde: Lessons for infection control
    • Murphy C. Inactivated glutaraldehyde: lessons for infection control Am J Infect Control 26 1998 159-160
    • (1998) Am. J. Infect. Control , vol.26 , pp. 159-160
    • Murphy, C.1
  • 80
    • 1942481538 scopus 로고    scopus 로고
    • Recall of patients after use of inactive batch of Cidex disinfection solution in Belgian hospitals
    • Fifth International Conference of the Hospital Infection Society, Edinburgh: Hospital Infection Society, September 15-18
    • Carsauw H, Debacker N. Recall of patients after use of inactive batch of Cidex disinfection solution in Belgian hospitals, Fifth International Conference of the Hospital Infection Society, Edinburgh: Hospital Infection Society, September 15-18, 2002.
    • (2002)
    • Carsauw, H.1    Debacker, N.2
  • 81
    • 0033538360 scopus 로고    scopus 로고
    • Bronchoscopy-related infections and pseudoinfections-New York, 1996 and 1998
    • Centers for Disease Control and Prevention
    • Centers for Disease Control and Prevention Bronchoscopy-related infections and pseudoinfections-New York, 1996 and 1998 MMWR 48 1999 557-560
    • (1999) MMWR , vol.48 , pp. 557-560
  • 82
    • 58149403052 scopus 로고
    • Sterilization or disinfection of flexible fiberoptic endoscopes
    • Bond W.W. Favero M.S. Mackel D.C. Mallison G.F. Sterilization or disinfection of flexible fiberoptic endoscopes AORN J 30 1979 350-352
    • (1979) AORN J. , vol.30 , pp. 350-352
    • Bond, W.W.1    Favero, M.S.2    Mackel, D.C.3    Mallison, G.F.4
  • 83
    • 0029738949 scopus 로고    scopus 로고
    • APIC guideline for selection and use of disinfectants
    • 1994, 1995, and 1996 APIC Guidelines Committe Association for Professionals in Infection Control and Epidemiology, Inc
    • Rutala W.A. 1994, 1995, and 1996 APIC Guidelines Committee APIC guideline for selection and use of disinfectants. Association for Professionals in Infection Control and Epidemiology, Inc Am J Infect Control 24 1996 313-342
    • (1996) Am. J. Infect. Control , vol.24 , pp. 313-342
    • Rutala, W.A.1
  • 84
    • 0032817473 scopus 로고    scopus 로고
    • Levels of naturally occurring microorganisms on surgical instruments after clinical use and after washing
    • Chu N.S. Chan-Myers H. Ghazanfari N. Antonoplos N. Antonoplos P. Levels of naturally occurring microorganisms on surgical instruments after clinical use and after washing Am J Infect Control 27 1999 315-319
    • (1999) Am. J. Infect. Control , vol.27 , pp. 315-319
    • Chu, N.S.1    Chan-Myers, H.2    Ghazanfari, N.3    Antonoplos, N.4    Antonoplos, P.5
  • 86
    • 0031874972 scopus 로고    scopus 로고
    • Comparative evaluation of the sporicidal activity of new low-temperature sterilization technologies: Ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid
    • Rutala W.A. Gergen M.F. Weber D.J. Comparative evaluation of the sporicidal activity of new low-temperature sterilization technologies: ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid Am J Infect Control 26 1998 393-398
    • (1998) Am. J. Infect. Control , vol.26 , pp. 393-398
    • Rutala, W.A.1    Gergen, M.F.2    Weber, D.J.3
  • 87
    • 0034826490 scopus 로고    scopus 로고
    • Nosocomial transmission of imipenem-resistant Pseudomonas aeruginosa following bronchoscopy associated with improper connection to the STERIS System 1 Processor
    • Sorin M. Segal-Maurer S. Urban C. Combest A. Rahal J.J. Nosocomial transmission of imipenem-resistant Pseudomonas aeruginosa following bronchoscopy associated with improper connection to the STERIS System 1 Processor Infect Control Hosp Epidemiol 22 2001 409-413
    • (2001) Infect. Control Hosp. Epidemiol. , vol.22 , pp. 409-413
    • Sorin, M.1    Segal-Maurer, S.2    Urban, C.3    Combest, A.4    Rahal, J.J.5
  • 88
    • 0024757883 scopus 로고
    • Pseudoepidemic of Rhodotorula rubra in patients undergoing fiberoptic bronchoscopy
    • Hoffmann K.K. Weber D.J. Rutala W.A. Pseudoepidemic of Rhodotorula rubra in patients undergoing fiberoptic bronchoscopy Infect Control Hosp Epidemiol 10 1989 511-514
    • (1989) Infect. Control Hosp. Epidemiol. , vol.10 , pp. 511-514
    • Hoffmann, K.K.1    Weber, D.J.2    Rutala, W.A.3
  • 89
    • 0022501175 scopus 로고
    • CDC Guideline for handwashing and hospital environmental control, 1985
    • Garner J.S. Favero M.S. CDC Guideline for handwashing and hospital environmental control, 1985 Infect Control 7 1986 231-243
    • (1986) Infect. Control , vol.7 , pp. 231-243
    • Garner, J.S.1    Favero, M.S.2
  • 90
    • 0038851428 scopus 로고    scopus 로고
    • Impact of variation in reprocessing invasive fiberoptic scopes on patient outcomes
    • Burns S. Edwards M. Jennings J. et al. Impact of variation in reprocessing invasive fiberoptic scopes on patient outcomes Infect Control Hosp Epidemiol 17 Suppl. 1996 P42
    • (1996) Infect. Control Hosp. Epidemiol. , vol.17 , Issue.SUPPL.
    • Burns, S.1    Edwards, M.2    Jennings, J.3
  • 91
    • 0343990780 scopus 로고    scopus 로고
    • Liquid sterilization versus high level disinfection in the urologic office
    • Fuselier H.A. Jr Mason C. Liquid sterilization versus high level disinfection in the urologic office Urology 50 1997 337-340
    • (1997) Urology , vol.50 , pp. 337-340
    • Fuselier Jr., H.A.1    Mason, C.2
  • 92
    • 0022258740 scopus 로고
    • Mycobacterium xenopi and Mycobacterium kansasii in a hospital water supply
    • Wright E.P. Collins C.H. Yates M.D. Mycobacterium xenopi and Mycobacterium kansasii in a hospital water supply J Hosp Infect 6 1985 175-178
    • (1985) J. Hosp. Infect. , vol.6 , pp. 175-178
    • Wright, E.P.1    Collins, C.H.2    Yates, M.D.3
  • 93
    • 0033171421 scopus 로고    scopus 로고
    • Legionella: From environmental habitats to disease pathology, detection and control
    • Atlas R.M. Legionella: from environmental habitats to disease pathology, detection and control Environ Microbiol 1 1999 283-293
    • (1999) Environ. Microbiol. , vol.1 , pp. 283-293
    • Atlas, R.M.1
  • 94
    • 17344367024 scopus 로고    scopus 로고
    • Nosocomial outbreaks/pseudo-outbreaks caused by nontuberculous mycobacteria
    • Wallace R.J.Jr Brown B.A. Driffith D.E. Nosocomial outbreaks/pseudo-outbreaks caused by nontuberculous mycobacteria Annu Rev Microbiol 52 1998 453-490
    • (1998) Annu. Rev. Microbiol. , vol.52 , pp. 453-490
    • Wallace, R.J.1    Brown, B.A.2    Driffith, D.E.3
  • 95
    • 0020787946 scopus 로고
    • Guideline for isolation precautions in hospitals
    • Garner J.S. Simmons B.P. Guideline for isolation precautions in hospitals Infect Control 4 1983 245-325
    • (1983) Infect. Control , vol.4 , pp. 245-325
    • Garner, J.S.1    Simmons, B.P.2
  • 96
    • 0032946659 scopus 로고    scopus 로고
    • Disinfection of biopsy forceps and culture of Helicobacter pylori from gastric mucosal biopsies
    • Graham D.Y. Osato M.S. Disinfection of biopsy forceps and culture of Helicobacter pylori from gastric mucosal biopsies Am J Gastroenterol 94 1999 1422-1423
    • (1999) Am. J. Gastroenterol. , vol.94 , pp. 1422-1423
    • Graham, D.Y.1    Osato, M.S.2
  • 97
    • 0025311776 scopus 로고
    • Effect of methodology, dilution, and exposure time on the tuberculocidal activty of glutaraldehyde-based disinfectants
    • Cole E.C. Rutala W.A. Nessen L. Wannamaker N.S. Weber D.J. Effect of methodology, dilution, and exposure time on the tuberculocidal activty of glutaraldehyde-based disinfectants Appl Environ Microbiol 56 1990 1813-1817
    • (1990) Appl. Environ. Microbiol. , vol.56 , pp. 1813-1817
    • Cole, E.C.1    Rutala, W.A.2    Nessen, L.3    Wannamaker, N.S.4    Weber, D.J.5
  • 98
    • 0026095191 scopus 로고
    • Inactivation of Mycobacterium tuberculosis and Mycobacterium bovis by 14 hospital disinfectants
    • Rutala W.A. Code E.C. Wannamaker N.S. Weber D.J. Inactivation of Mycobacterium tuberculosis and Mycobacterium bovis by 14 hospital disinfectants Am J Med 91 1991 267S-271S
    • (1991) Am. J. Med. , vol.91
    • Rutala, W.A.1    Code, E.C.2    Wannamaker, N.S.3    Weber, D.J.4
  • 100
    • 0035321323 scopus 로고    scopus 로고
    • Efficacy of high-level disinfectants for reprocessing gastrointestinal endoscopes in simulated use-testing
    • Foliente R.L.K.B. Aprecio R.M. Bains H.J. Kettering J.D. Chen Y.K. Efficacy of high-level disinfectants for reprocessing gastrointestinal endoscopes in simulated use-testing Gastrointest Endosc 53 2001 456-462
    • (2001) Gastrointest. Endosc. , vol.53 , pp. 456-462
    • Foliente, R.L.K.B.1    Aprecio, R.M.2    Bains, H.J.3    Kettering, J.D.4    Chen, Y.K.5
  • 101
    • 0022746072 scopus 로고
    • Kinetics of the tuberculocidal response by alkaline glutaraldehyde in solution and on an inert surface
    • Collins F.M. Kinetics of the tuberculocidal response by alkaline glutaraldehyde in solution and on an inert surface J Appl Bacteriol 61 1986 87-93
    • (1986) J. Appl. Bacteriol. , vol.61 , pp. 87-93
    • Collins, F.M.1
  • 102
    • 0023135296 scopus 로고
    • Use of membrane filters for measurement of mycobactericidal activity of alkaline glutaraldehyde solution
    • Collins F.M. Use of membrane filters for measurement of mycobactericidal activity of alkaline glutaraldehyde solution Appl Environ Microbiol 53 1987 737-739
    • (1987) Appl. Environ. Microbiol. , vol.53 , pp. 737-739
    • Collins, F.M.1
  • 103
    • 0023404984 scopus 로고
    • A more accurate method for measurement of tuberculocidal activity of disinfectants
    • Ascenzi J.M. Ezzell R.J. Wendt T.M. A more accurate method for measurement of tuberculocidal activity of disinfectants Appl Environ Microbiol 53 1987 2189-2192
    • (1987) Appl. Environ. Microbiol. , vol.53 , pp. 2189-2192
    • Ascenzi, J.M.1    Ezzell, R.J.2    Wendt, T.M.3
  • 105
    • 0032788110 scopus 로고    scopus 로고
    • Effectiveness of a manual disinfection procedure in eliminating hepatitis C virus from experimentally contaminated endoscopes
    • Chanzy B. Duc-Bin D.L. Rousset B. et al. Effectiveness of a manual disinfection procedure in eliminating hepatitis C virus from experimentally contaminated endoscopes Gastrointest Endosc 50 1999 147-151
    • (1999) Gastrointest. Endosc. , vol.50 , pp. 147-151
    • Chanzy, B.1    Duc-Bin, D.L.2    Rousset, B.3
  • 106
    • 0027444731 scopus 로고
    • Bactericidal, virucidal, and mycobactericidal activities of reused alkaline glutaraldehyde in an endoscopy unit
    • Mbithi J.N. Springthorpe V.S. Sattar S.A. Pacquette M. Bactericidal, virucidal, and mycobactericidal activities of reused alkaline glutaraldehyde in an endoscopy unit J Clin Microbiol 31 1993 2988-2995
    • (1993) J. Clin. Microbiol. , vol.31 , pp. 2988-2995
    • Mbithi, J.N.1    Springthorpe, V.S.2    Sattar, S.A.3    Pacquette, M.4
  • 107
    • 0022620159 scopus 로고
    • Efficacy of routine fiberoptic endoscope cleaning and disinfection for killing Clostridium difficile
    • Hughes C.E. Gebhard R.L. Peterson L.R. Gerding D.N. Efficacy of routine fiberoptic endoscope cleaning and disinfection for killing Clostridium difficile Gastrointest Endosc 32 1986 7-9
    • (1986) Gastrointest. Endosc. , vol.32 , pp. 7-9
    • Hughes, C.E.1    Gebhard, R.L.2    Peterson, L.R.3    Gerding, D.N.4
  • 109
    • 0021957357 scopus 로고
    • The activity of glutaraldehyde against Clostridium difficile
    • Dyas A. Das B.C. The activity of glutaraldehyde against Clostridium difficile J Hosp Infect 6 1985 41-44
    • (1985) J. Hosp. Infect. , vol.6 , pp. 41-44
    • Dyas, A.1    Das, B.C.2
  • 110
    • 0034930048 scopus 로고    scopus 로고
    • Inactivation of hepatitis B virus in plasma by hospital in-use chemical disinfectants assessed by a modified HepG2 cell culture
    • Payan C. Cottin J. Lemarie C. Ramont C. Inactivation of hepatitis B virus in plasma by hospital in-use chemical disinfectants assessed by a modified HepG2 cell culture J Hosp Infect 47 2001 282-287
    • (2001) J. Hosp. Infect. , vol.47 , pp. 282-287
    • Payan, C.1    Cottin, J.2    Lemarie, C.3    Ramont, C.4
  • 113
    • 0025078475 scopus 로고
    • Virucidal activity of disinfectants: Studies with the poliovirus
    • Tyler R. Ayliffe G.A. Bradley C. Virucidal activity of disinfectants: studies with the poliovirus J Hosp Infect 15 1990 339-345
    • (1990) J. Hosp. Infect. , vol.15 , pp. 339-345
    • Tyler, R.1    Ayliffe, G.A.2    Bradley, C.3
  • 115
    • 0033126393 scopus 로고    scopus 로고
    • The mycobactericidal efficacy of ortho-pathalaldehyde and the comparative resistances of Mycobacterium bovis, Mycobacterium terrae, and Mycobacterium chelonae
    • Gregory A.W. Schaalje G.B. Smart J.D. Robison R.A. The mycobactericidal efficacy of ortho-pathalaldehyde and the comparative resistances of Mycobacterium bovis, Mycobacterium terrae, and Mycobacterium chelonae Infect Control Hosp Epidemiol 20 1999 324-330
    • (1999) Infect. Control Hosp. Epidemiol. , vol.20 , pp. 324-330
    • Gregory, A.W.1    Schaalje, G.B.2    Smart, J.D.3    Robison, R.A.4
  • 116
    • 0033398235 scopus 로고    scopus 로고
    • Studies on the mechanisms of the antibacterial action of ortho-phthalaldehyde
    • Walsh S.E. Maillard J.Y. Simons C. Russell A.D. Studies on the mechanisms of the antibacterial action of ortho-phthalaldehyde J Appl Microbiol 87 1999 702-710
    • (1999) J. Appl. Microbiol. , vol.87 , pp. 702-710
    • Walsh, S.E.1    Maillard, J.Y.2    Simons, C.3    Russell, A.D.4
  • 117
    • 0032977409 scopus 로고    scopus 로고
    • Ortho-phthalaldehyde: A possible alternative to glutaraldehyde for high level disinfection
    • Walsh S.E. Maillard J.Y. Russell A.D. Ortho-phthalaldehyde: a possible alternative to glutaraldehyde for high level disinfection J Appl Microbiol 86 1999 1039-1046
    • (1999) J. Appl. Microbiol. , vol.86 , pp. 1039-1046
    • Walsh, S.E.1    Maillard, J.Y.2    Russell, A.D.3
  • 118
    • 0034912519 scopus 로고    scopus 로고
    • Comparison of the mycobactericidal activity of ortho-phthalaldehyde, glutaraldehyde, and other dialdehydes by a quantitative suspension test
    • Fraud S. Maillard J.-Y. Russell A.D. Comparison of the mycobactericidal activity of ortho-phthalaldehyde, glutaraldehyde, and other dialdehydes by a quantitative suspension test J Hosp Infect 48 2001 214-221
    • (2001) J. Hosp. Infect. , vol.48 , pp. 214-221
    • Fraud, S.1    Maillard, J.-Y.2    Russell, A.D.3
  • 119
    • 0033160447 scopus 로고    scopus 로고
    • Sporicidal activity of a new low-temperature sterilization technology: The Sterrad 50 sterilizer
    • Rutala W.A. Gergen M.F. Weber D.J. Sporicidal activity of a new low-temperature sterilization technology: the Sterrad 50 sterilizer Infect Control Hosp Epidemiol 20 1999 514-516
    • (1999) Infect. Control Hosp. Epidemiol. , vol.20 , pp. 514-516
    • Rutala, W.A.1    Gergen, M.F.2    Weber, D.J.3
  • 120
    • 0026409986 scopus 로고
    • Use of tap water and disinfection practices in outpatient settings. A survey of otolaryngologists
    • Lowry P.W. Jarvis W.R. Use of tap water and disinfection practices in outpatient settings. A survey of otolaryngologists Arch Otolaryngol Head Neck Surg 117 1991 886-888
    • (1991) Arch. Otolaryngol. Head Neck Surg. , vol.117 , pp. 886-888
    • Lowry, P.W.1    Jarvis, W.R.2
  • 121
    • 0030758879 scopus 로고    scopus 로고
    • Pseudoepidemic of Legionella pneumophila serogroup 6 associated with contaminated bronchoscopes
    • Mitchell D.H. Hicks L.J. Chiew R. Montanaro J.C. Chen S.C. Pseudoepidemic of Legionella pneumophila serogroup 6 associated with contaminated bronchoscopes J Hosp Infect 37 1997 19-23
    • (1997) J. Hosp. Infect. , vol.37 , pp. 19-23
    • Mitchell, D.H.1    Hicks, L.J.2    Chiew, R.3    Montanaro, J.C.4    Chen, S.C.5
  • 122
    • 0021818787 scopus 로고
    • Water-related nosocomial pneumonia caused by Legionella pneumophila serogroups 1 and 10
    • Meenhorst P.L. Reingold A.L. Groothuis D.G. et al. Water-related nosocomial pneumonia caused by Legionella pneumophila serogroups 1 and 10 J Infect Dis 152 1985 356-364
    • (1985) J. Infect. Dis. , vol.152 , pp. 356-364
    • Meenhorst, P.L.1    Reingold, A.L.2    Groothuis, D.G.3
  • 124
    • 0023812608 scopus 로고
    • Chemical colitis due to endoscope cleaning solutions: A mimic of pseudomembranous colitis
    • Jonas G. Mahoney A. Murray J. Gertler S. Chemical colitis due to endoscope cleaning solutions: a mimic of pseudomembranous colitis Gastroenterology 95 1988 1403-1408
    • (1988) Gastroenterology , vol.95 , pp. 1403-1408
    • Jonas, G.1    Mahoney, A.2    Murray, J.3    Gertler, S.4
  • 125
    • 0023941091 scopus 로고
    • Proctitis following colonoscopy
    • Levine D.S. Proctitis following colonoscopy Gastrointest Endosc 34 1988 269-272
    • (1988) Gastrointest. Endosc. , vol.34 , pp. 269-272
    • Levine, D.S.1
  • 126
    • 0026520681 scopus 로고
    • Investigation of an outbreak of bloody diarrhea: Association with endoscopic cleaning solution and demonstrating of lesions in an animal model
    • Durante L. Zulty J.C. Israel E. et al. Investigation of an outbreak of bloody diarrhea: association with endoscopic cleaning solution and demonstrating of lesions in an animal model Am J Med 92 1992 476-480
    • (1992) Am. J. Med. , vol.92 , pp. 476-480
    • Durante, L.1    Zulty, J.C.2    Israel, E.3
  • 127
    • 0027482715 scopus 로고
    • Glutaraldehyde-induced proctitis after endorectal ultrasound examination: A higher risk of incidence than expected?
    • Burtin P. Ruget O. Petit R. Boyer J. Glutaraldehyde-induced proctitis after endorectal ultrasound examination: a higher risk of incidence than expected? Gastrointest Endosc 39 1993 859-866
    • (1993) Gastrointest. Endosc. , vol.39 , pp. 859-866
    • Burtin, P.1    Ruget, O.2    Petit, R.3    Boyer, J.4
  • 128
    • 0029396605 scopus 로고
    • Glutaraldehyde proctitis
    • Babb R.R. Paaso B.T. Glutaraldehyde proctitis West J Med 163 1995 477-488
    • (1995) West J. Med. , vol.163 , pp. 477-488
    • Babb, R.R.1    Paaso, B.T.2
  • 129
    • 0029028288 scopus 로고
    • Disinfectant colitis. Rinse as well as you wash
    • Ryan C.K. Potter G.D. Disinfectant colitis. Rinse as well as you wash J Clin Gastroenterol 21 1995 6-9
    • (1995) J. Clin. Gastroenterol. , vol.21 , pp. 6-9
    • Ryan, C.K.1    Potter, G.D.2
  • 130
    • 0028935925 scopus 로고
    • Glutaraldehyde colitis following endoscopy: Clinical and pathological features and investigation of an outbreak
    • West A.B. Kuan S.F. Bennick M. Lagarde S. Glutaraldehyde colitis following endoscopy: clinical and pathological features and investigation of an outbreak Gastroenterology 108 1995 1250-1255
    • (1995) Gastroenterology , vol.108 , pp. 1250-1255
    • West, A.B.1    Kuan, S.F.2    Bennick, M.3    Lagarde, S.4
  • 132
    • 0027930246 scopus 로고
    • Endoscope-induced colitis: Description, probable cause by glutaraldehyde, and prevention
    • Rozen P. Somjen G.J. Baratz M. Kimel R. Arber N. Gilat T. Endoscope-induced colitis: description, probable cause by glutaraldehyde, and prevention Gastrointest Endosc 40 1994 547-553
    • (1994) Gastrointest. Endosc. , vol.40 , pp. 547-553
    • Rozen, P.1    Somjen, G.J.2    Baratz, M.3    Kimel, R.4    Arber, N.5    Gilat, T.6
  • 133
    • 1942449150 scopus 로고    scopus 로고
    • Recommended practices for sterilization in perioperative practice settings. 2000 Standards, recommended practices, and guidelines
    • Association of Operating Room Nurses Denver, CO: AORN
    • Association of Operating Room Nurses Recommended practices for sterilization in perioperative practice settings. 2000 Standards, recommended practices, and guidelines 2000 AORN Denver, CO
    • (2000)
  • 134
    • 0023759803 scopus 로고
    • Mycobacterium chelonae causing otitis media in an ear-nose-and-throat practice
    • Lowry P.W. Jarvis W.R. Oberle A.D. et al. Mycobacterium chelonae causing otitis media in an ear-nose-and-throat practice N Engl J Med 319 1988 978-982
    • (1988) N. Engl. J. Med. , vol.319 , pp. 978-982
    • Lowry, P.W.1    Jarvis, W.R.2    Oberle, A.D.3
  • 135
    • 25944448445 scopus 로고    scopus 로고
    • Threshold limit values for chemical substances and physical agents and biological exposure indices
    • American Conference of Governmental Industrial Hygienists (ACGIH) Cincinnati: ACGIH
    • American Conference of Governmental Industrial Hygienists (ACGIH) Threshold limit values for chemical substances and physical agents and biological exposure indices 2001 ACGIH Cincinnati
    • (2001)
  • 136
    • 0003591674 scopus 로고    scopus 로고
    • Occupational risks associated with the use of selected disinfectants and sterilants
    • W. A. Rutala (Ed.), Champlain, New York: Polyscience Publications
    • Weber D.J. Rutala W.A. Occupational risks associated with the use of selected disinfectants and sterilants In: Rutala W.A. (Ed.), Disinfection, sterilization, and antisepsis in healthcare 1998 211-226 Polyscience Publications Champlain, New York
    • (1998) Disinfection, Sterilization, and Antisepsis in Healthcare , pp. 211-226
    • Weber, D.J.1    Rutala, W.A.2
  • 137
    • 0024687623 scopus 로고
    • Expanding role of hospital epidemiology: Employee health-chemical exposure in the health care setting
    • Rutala W.A. Hamory B.H. Expanding role of hospital epidemiology: employee health-chemical exposure in the health care setting Infect Control Hosp Epidemiol 10 1989 261-266
    • (1989) Infect. Control Hosp. Epidemiol. , vol.10 , pp. 261-266
    • Rutala, W.A.1    Hamory, B.H.2
  • 138
    • 0011162135 scopus 로고
    • Air contaminants final rule
    • Occupational Safety and Health Administration
    • Occupational Safety and Health Administration Air contaminants final rule Fed Regist 58 1993 35338-35351
    • (1993) Fed. Regist. , vol.58 , pp. 35338-35351
  • 139
    • 1942513644 scopus 로고
    • Dilution of glutaraldehyde by automatic endoscope machine washers: The need for a quality control program
    • Abstracts of the 14th Annual Educational Conference of Association for Practitioners in Infection Control
    • Leong D. Dorsey G. Klapp M. Dilution of glutaraldehyde by automatic endoscope machine washers: the need for a quality control program Abstracts of the 14th Annual Educational Conference of Association for Practitioners in Infection Control vol. 108 1987
    • (1987) , vol.108
    • Leong, D.1    Dorsey, G.2    Klapp, M.3
  • 140
    • 1942417521 scopus 로고
    • Hazard Communication Standard. 29 CFR 1910.1200
    • Occupational Health and Safety Administration Washington, DC: OSHA
    • Occupational Health and Safety Administration Hazard Communication Standard. 29 CFR 1910.1200 1910 OSHA Washington, DC
    • (1910)
  • 141
    • 1942513641 scopus 로고    scopus 로고
    • Occupational safety and health administration: Regulations affecting healthcare facilities
    • W. A. Rutala (Ed.), Washington, DC: Association for Professionals in Infection Control and Epidemiology, Inc
    • Edens A.L. Occupational safety and health administration: regulations affecting healthcare acilities In: Rutala W.A. (Ed.), Disinfection, sterilization and antisepsis: principles and practices in healthcare facilities 2001 49-58 Association for Professionals in Infection Control and Epidemiology, Inc Washington, DC
    • (2001) Disinfection, Sterilization and Antisepsis: Principles and Practices in Healthcare Facilities , pp. 49-58
    • Edens, A.L.1
  • 142
    • 0025755742 scopus 로고
    • Frequency of nonparenteral occupational exposures of blood and body fluids before and after universal precautions training
    • Fahey B.J. Koziol D.E. Banks S.M. Henderson D.K. Frequency of nonparenteral occupational exposures of blood and body fluids before and after universal precautions training Am J Med 90 1991 145-153
    • (1991) Am. J. Med. , vol.90 , pp. 145-153
    • Fahey, B.J.1    Koziol, D.E.2    Banks, S.M.3    Henderson, D.K.4
  • 143
    • 0028267363 scopus 로고
    • Temporal association between implementation of universal precautions and a sustained progressive decrease in percutaneous exposures of blood
    • Beekmann S.E. Vlahov D. Koziol D.E. McShalley E.D. Schmitt J.M. Henderson D.K. Temporal association between implementation of universal precautions and a sustained progressive decrease in percutaneous exposures of blood Clin Infect Dis 18 1994 562-569
    • (1994) Clin. Infect. Dis. , vol.18 , pp. 562-569
    • Beekmann, S.E.1    Vlahov, D.2    Koziol, D.E.3    McShalley, E.D.4    Schmitt, J.M.5    Henderson, D.K.6
  • 144
    • 0001204332 scopus 로고
    • Occupational exposure to bloodborne pathogens; final rule
    • Occupational Safety and Health Administration
    • Occupational Safety and Health Administration Occupational exposure to bloodborne pathogens; final rule Fed Regist 56 1991 64003-64182
    • (1991) Fed. Regist. , vol.56 , pp. 64003-64182
  • 145
    • 0035013763 scopus 로고    scopus 로고
    • A review of the use of gowns and drapes (single use and reusable) in healthcare
    • Rutala W.A. Weber D.J. A review of the use of gowns and drapes (single use and reusable) in healthcare Infect Control Hosp Epidemiol 22 2001 248-257
    • (2001) Infect. Control Hosp. Epidemiol. , vol.22 , pp. 248-257
    • Rutala, W.A.1    Weber, D.J.2
  • 146
    • 0025280339 scopus 로고
    • Risk of exposure of surgical personnel to patients' blood during surgery at San Francisco General Hospital
    • Gerberding J.L. Littell C. Tarkington A. Brown A. Schecter W.P. Risk of exposure of surgical personnel to patients' blood during surgery at San Francisco General Hospital N Engl J Med 324 1991 1788-1793
    • (1991) N. Engl. J. Med. , vol.324 , pp. 1788-1793
    • Gerberding, J.L.1    Littell, C.2    Tarkington, A.3    Brown, A.4    Schecter, W.P.5
  • 147
    • 0027363542 scopus 로고
    • Efficacy of gloves in reducing blood volumes transferred during simulated needlestick injury
    • Mast S.T. Woolwine J.D. Gerdberding J.L. Efficacy of gloves in reducing blood volumes transferred during simulated needlestick injury J Infect Dis 168 1993 1589-1592
    • (1993) J. Infect. Dis. , vol.168 , pp. 1589-1592
    • Mast, S.T.1    Woolwine, J.D.2    Gerdberding, J.L.3
  • 148
    • 0002669888 scopus 로고    scopus 로고
    • Epidemics: Identification and management
    • R. P. Wenzel (Ed.), Baltimore: Williams and Wilkins
    • Wendt C. Herwaldt L.A. Epidemics: identification and management In: Wenzel R.P. (Ed.), Prevention and control of nosocomial infections 1997 175-214 Williams and Wilkins Baltimore
    • (1997) Prevention and Control of Nosocomial Infections , pp. 175-214
    • Wendt, C.1    Herwaldt, L.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.