메뉴 건너뛰기




Volumn 13, Issue , 2013, Pages

Multi-parametric MRI as an indirect evaluation tool of the mechanical properties of in-vitro cardiac tissues

Author keywords

Cardiac muscle; Mechanical properties; Multi parametric MRI; Multiple regressions; Myocardium; Principal component analysis; Ventricle

Indexed keywords

ANIMAL TISSUE; APPARENT DIFFUSION COEFFICIENT; ARTICLE; CARDIAC IMAGING; CARDIOVASCULAR MAGNETIC RESONANCE; CARDIOVASCULAR PARAMETERS; CONTROLLED STUDY; DIFFUSION COEFFICIENT; DIFFUSION TENSOR IMAGING; FRACTIONAL ANISOTROPY; HEART MUSCLE; IN VITRO STUDY; MAGNETIZATION TRANSFER RATIO; MULTI PARAMETRIC CARDIOVASCULAR MAGNETIC RESONANCE; MULTIPLE LINEAR REGRESSION ANALYSIS; NONHUMAN; PRINCIPAL COMPONENT ANALYSIS; PRIORITY JOURNAL; RADIOLOGICAL PARAMETERS; RELAXATION TIME; REPRODUCIBILITY; SWINE; T1 RELAXATION TIME; T2 RELAXATION TIME; T2 VALUE; YOUNG MODULUS;

EID: 84875337766     PISSN: None     EISSN: 14712261     Source Type: Journal    
DOI: 10.1186/1471-2261-13-24     Document Type: Article
Times cited : (8)

References (61)
  • 2
    • 0019194592 scopus 로고
    • An analysis of the mechanical disadvantage of myocardial infarction in the canine left ventricle
    • Bogen DK, Rabinowitz SA, Needleman A, McMahon TA, Abelmann WH. An analysis of the mechanical disadvantage of myocardial infarction in the canine left ventricle. Circ Res 1980, 47:728-741.
    • (1980) Circ Res , vol.47 , pp. 728-741
    • Bogen, D.K.1    Rabinowitz, S.A.2    Needleman, A.3    McMahon, T.A.4    Abelmann, W.H.5
  • 5
    • 33644833381 scopus 로고    scopus 로고
    • A mixed finite element formulation for a non-linear, transversely isotropic material model for the cardiac tissue
    • Thorvaldsen T, Osnes H, Sundnes J. A mixed finite element formulation for a non-linear, transversely isotropic material model for the cardiac tissue. Comput Methods Biomech Biomed Engin 2005, 8:369-379.
    • (2005) Comput Methods Biomech Biomed Engin , vol.8 , pp. 369-379
    • Thorvaldsen, T.1    Osnes, H.2    Sundnes, J.3
  • 6
    • 0032030126 scopus 로고    scopus 로고
    • An analytical method for the determination of along-fibre to cross-fibre elastic modulus ratio in ventricular myocardium-a feasibility study
    • Yettram AL, Beecham MC. An analytical method for the determination of along-fibre to cross-fibre elastic modulus ratio in ventricular myocardium-a feasibility study. Med Eng Phys 1998, 20:103-108.
    • (1998) Med Eng Phys , vol.20 , pp. 103-108
    • Yettram, A.L.1    Beecham, M.C.2
  • 8
    • 42949087484 scopus 로고    scopus 로고
    • Magnetic resonance imaging-based finite element stress analysis after linear repair of left ventricular aneurysm
    • 1102 e1091-1092
    • Walker JC, Ratcliffe MB, Zhang P, Wallace AW, Hsu EW, Saloner DA, Guccione JM. Magnetic resonance imaging-based finite element stress analysis after linear repair of left ventricular aneurysm. J Thorac Cardiovasc Surg 2008, 135:1094-1102. 1102 e1091-1092.
    • (2008) J Thorac Cardiovasc Surg , vol.135 , pp. 1094-1102
    • Walker, J.C.1    Ratcliffe, M.B.2    Zhang, P.3    Wallace, A.W.4    Hsu, E.W.5    Saloner, D.A.6    Guccione, J.M.7
  • 10
    • 62849103587 scopus 로고    scopus 로고
    • Tagged cine magnetic resonance imaging with a finite element model can predict the severity of retrosternal adhesions prior to redo cardiac surgery
    • Yoshioka I, Saiki Y, Ichinose A, Takase K, Takahashi S, Ohashi T, Sato M, Tabayashi K. Tagged cine magnetic resonance imaging with a finite element model can predict the severity of retrosternal adhesions prior to redo cardiac surgery. J Thorac Cardiovasc Surg 2009, 137:957-962.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 957-962
    • Yoshioka, I.1    Saiki, Y.2    Ichinose, A.3    Takase, K.4    Takahashi, S.5    Ohashi, T.6    Sato, M.7    Tabayashi, K.8
  • 11
    • 33750246417 scopus 로고    scopus 로고
    • Estimation of cardiac hyperelastic material properties from MRI tissue tagging and diffusion tensor imaging
    • Augenstein KF, Cowan BR, LeGrice IJ, Young AA. Estimation of cardiac hyperelastic material properties from MRI tissue tagging and diffusion tensor imaging. Med Image Comput Comput Assist Interv 2006, 9:628-635.
    • (2006) Med Image Comput Comput Assist Interv , vol.9 , pp. 628-635
    • Augenstein, K.F.1    Cowan, B.R.2    LeGrice, I.J.3    Young, A.A.4
  • 13
    • 68949099437 scopus 로고    scopus 로고
    • Modelling passive diastolic mechanics with quantitative MRI of cardiac structure and function
    • Wang VY, Lam HI, Ennis DB, Cowan BR, Young AA, Nash MP. Modelling passive diastolic mechanics with quantitative MRI of cardiac structure and function. Med Image Anal 2009, 13:773-784.
    • (2009) Med Image Anal , vol.13 , pp. 773-784
    • Wang, V.Y.1    Lam, H.I.2    Ennis, D.B.3    Cowan, B.R.4    Young, A.A.5    Nash, M.P.6
  • 16
    • 67650077678 scopus 로고    scopus 로고
    • MR elastography as a method for the assessment of myocardial stiffness: comparison with an established pressure-volume model in a left ventricular model of the heart
    • Kolipaka A, McGee KP, Araoz PA, Glaser KJ, Manduca A, Romano AJ, Ehman RL. MR elastography as a method for the assessment of myocardial stiffness: comparison with an established pressure-volume model in a left ventricular model of the heart. Magn Reson Med 2009, 62:135-140.
    • (2009) Magn Reson Med , vol.62 , pp. 135-140
    • Kolipaka, A.1    McGee, K.P.2    Araoz, P.A.3    Glaser, K.J.4    Manduca, A.5    Romano, A.J.6    Ehman, R.L.7
  • 18
    • 62649114456 scopus 로고    scopus 로고
    • MR elastography of the human heart: noninvasive assessment of myocardial elasticity changes by shear wave amplitude variations
    • Sack I, Rump J, Elgeti T, Samani A, Braun J. MR elastography of the human heart: noninvasive assessment of myocardial elasticity changes by shear wave amplitude variations. Magn Reson Med 2009, 61:668-677.
    • (2009) Magn Reson Med , vol.61 , pp. 668-677
    • Sack, I.1    Rump, J.2    Elgeti, T.3    Samani, A.4    Braun, J.5
  • 19
    • 70449393267 scopus 로고    scopus 로고
    • Application of DENSE-MR-elastography to the human heart
    • Robert B, Sinkus R, Gennisson JL, Fink M. Application of DENSE-MR-elastography to the human heart. Magn Reson Med 2009, 62:1155-1163.
    • (2009) Magn Reson Med , vol.62 , pp. 1155-1163
    • Robert, B.1    Sinkus, R.2    Gennisson, J.L.3    Fink, M.4
  • 20
    • 79955428580 scopus 로고    scopus 로고
    • In vivo assessment of MR elastography-derived effective end-diastolic myocardial stiffness under different loading conditions
    • Kolipaka A, McGee KP, Manduca A, Anavekar N, Ehman RL, Araoz PA. In vivo assessment of MR elastography-derived effective end-diastolic myocardial stiffness under different loading conditions. J Magn Reson Imaging 2011, 33:1224-1228.
    • (2011) J Magn Reson Imaging , vol.33 , pp. 1224-1228
    • Kolipaka, A.1    McGee, K.P.2    Manduca, A.3    Anavekar, N.4    Ehman, R.L.5    Araoz, P.A.6
  • 22
    • 24144449916 scopus 로고    scopus 로고
    • Magnetic resonance imaging assessment of myocardial elastic modulus and viscosity using displacement imaging and phase-contrast velocity mapping
    • Wen H, Bennett E, Epstein N, Plehn J. Magnetic resonance imaging assessment of myocardial elastic modulus and viscosity using displacement imaging and phase-contrast velocity mapping. Magn Reson Med 2005, 54:538-548.
    • (2005) Magn Reson Med , vol.54 , pp. 538-548
    • Wen, H.1    Bennett, E.2    Epstein, N.3    Plehn, J.4
  • 23
    • 64749086865 scopus 로고    scopus 로고
    • Computational cardiac atlases: from patient to population and back
    • Young AA, Frangi AF. Computational cardiac atlases: from patient to population and back. Exp Physiol 2009, 94:578-596.
    • (2009) Exp Physiol , vol.94 , pp. 578-596
    • Young, A.A.1    Frangi, A.F.2
  • 28
    • 36349005933 scopus 로고    scopus 로고
    • Dynamic water changes in excised rat myocardium assessed by continuous distribution of T1 and T2
    • Bruvold M, Seland JG, Brurok H, Jynge P. Dynamic water changes in excised rat myocardium assessed by continuous distribution of T1 and T2. Magn Reson Med 2007, 58:442-447.
    • (2007) Magn Reson Med , vol.58 , pp. 442-447
    • Bruvold, M.1    Seland, J.G.2    Brurok, H.3    Jynge, P.4
  • 33
    • 36249011055 scopus 로고    scopus 로고
    • Reconstruction and visualization of fiber and laminar structure in the normal human heart from ex vivo diffusion tensor magnetic resonance imaging (DTMRI) data
    • Rohmer D, Sitek A, Gullberg GT. Reconstruction and visualization of fiber and laminar structure in the normal human heart from ex vivo diffusion tensor magnetic resonance imaging (DTMRI) data. Invest Radiol 2007, 42:777-789.
    • (2007) Invest Radiol , vol.42 , pp. 777-789
    • Rohmer, D.1    Sitek, A.2    Gullberg, G.T.3
  • 35
  • 37
    • 26844581525 scopus 로고    scopus 로고
    • Ex vivo 3D diffusion tensor imaging and quantification of cardiac laminar structure
    • Helm PA, Tseng HJ, Younes L, McVeigh ER, Winslow RL. Ex vivo 3D diffusion tensor imaging and quantification of cardiac laminar structure. Magn Reson Med 2005, 54:850-859.
    • (2005) Magn Reson Med , vol.54 , pp. 850-859
    • Helm, P.A.1    Tseng, H.J.2    Younes, L.3    McVeigh, E.R.4    Winslow, R.L.5
  • 38
    • 0037372879 scopus 로고    scopus 로고
    • Stunned, infarcted, and normal myocardium in dogs: simultaneous differentiation by using gadolinium-enhanced cine MR imaging with magnetization transfer contrast
    • Weiss CR, Aletras AH, London JF, Taylor JL, Epstein FH, Wassmuth R, Balaban RS, Arai AE. Stunned, infarcted, and normal myocardium in dogs: simultaneous differentiation by using gadolinium-enhanced cine MR imaging with magnetization transfer contrast. Radiology 2003, 226:723-730.
    • (2003) Radiology , vol.226 , pp. 723-730
    • Weiss, C.R.1    Aletras, A.H.2    London, J.F.3    Taylor, J.L.4    Epstein, F.H.5    Wassmuth, R.6    Balaban, R.S.7    Arai, A.E.8
  • 42
    • 33645734613 scopus 로고    scopus 로고
    • Introduction to diffusion tensor imaging mathematics: Part I. Tensors, rotations, and eigenvectors
    • Kingsley PB. Introduction to diffusion tensor imaging mathematics: Part I. Tensors, rotations, and eigenvectors. Concepts in Magnetic Resonance Part A 2006, 28A:101-122.
    • (2006) Concepts in Magnetic Resonance Part A , vol.28 A , pp. 101-122
    • Kingsley, P.B.1
  • 43
    • 33645731549 scopus 로고    scopus 로고
    • Introduction to diffusion tensor imaging mathematics: Part II. Anisotropy, diffusion-weighting factors, and gradient encoding schemes
    • Kingsley PB. Introduction to diffusion tensor imaging mathematics: Part II. Anisotropy, diffusion-weighting factors, and gradient encoding schemes. Concepts in Magnetic Resonance Part A 2006, 28A:123-154.
    • (2006) Concepts in Magnetic Resonance Part A , vol.28 A , pp. 123-154
    • Kingsley, P.B.1
  • 44
    • 0022969218 scopus 로고
    • MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders
    • Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M. MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 1986, 161:401-407.
    • (1986) Radiology , vol.161 , pp. 401-407
    • Le Bihan, D.1    Breton, E.2    Lallemand, D.3    Grenier, P.4    Cabanis, E.5    Laval-Jeantet, M.6
  • 45
    • 57849141202 scopus 로고    scopus 로고
    • In vitro technique in estimation of passive mechanical properties of bovine heart part I. Experimental techniques and data
    • Ghaemi H, Behdinan K, Spence AD. In vitro technique in estimation of passive mechanical properties of bovine heart part I. Experimental techniques and data. Med Eng Phys 2009, 31:76-82.
    • (2009) Med Eng Phys , vol.31 , pp. 76-82
    • Ghaemi, H.1    Behdinan, K.2    Spence, A.D.3
  • 46
    • 0025472075 scopus 로고
    • Determination of a constitutive relation for passive myocardium: II. Parameter estimation
    • Humphrey JD, Strumpf RK, Yin FC. Determination of a constitutive relation for passive myocardium: II. Parameter estimation. J Biomech Eng 1990, 112:340-346.
    • (1990) J Biomech Eng , vol.112 , pp. 340-346
    • Humphrey, J.D.1    Strumpf, R.K.2    Yin, F.C.3
  • 47
    • 0023457260 scopus 로고
    • On constitutive relations and finite deformations of passive cardiac tissue: I. A pseudostrain-energy function
    • Humphrey JD, Yin FC. On constitutive relations and finite deformations of passive cardiac tissue: I. A pseudostrain-energy function. J Biomech Eng 1987, 109:298-304.
    • (1987) J Biomech Eng , vol.109 , pp. 298-304
    • Humphrey, J.D.1    Yin, F.C.2
  • 48
    • 0025469241 scopus 로고
    • Determination of a constitutive relation for passive myocardium: I. A new functional form
    • Humphrey JD, Strumpf RK, Yin FC. Determination of a constitutive relation for passive myocardium: I. A new functional form. J Biomech Eng 1990, 112:333-339.
    • (1990) J Biomech Eng , vol.112 , pp. 333-339
    • Humphrey, J.D.1    Strumpf, R.K.2    Yin, F.C.3
  • 49
    • 0032144150 scopus 로고    scopus 로고
    • A multiaxial constitutive law for mammalian left ventricular myocardium in steady-state barium contracture or tetanus
    • Lin DH, Yin FC. A multiaxial constitutive law for mammalian left ventricular myocardium in steady-state barium contracture or tetanus. J Biomech Eng 1998, 120:504-517.
    • (1998) J Biomech Eng , vol.120 , pp. 504-517
    • Lin, D.H.1    Yin, F.C.2
  • 50
    • 57849108082 scopus 로고    scopus 로고
    • In vitro technique in estimation of passive mechanical properties of bovine heart part II. Constitutive relation and finite element analysis
    • Ghaemi H, Behdinan K, Spence AD. In vitro technique in estimation of passive mechanical properties of bovine heart part II. Constitutive relation and finite element analysis. Med Eng Phys 2009, 31:83-91.
    • (2009) Med Eng Phys , vol.31 , pp. 83-91
    • Ghaemi, H.1    Behdinan, K.2    Spence, A.D.3
  • 53
    • 33644638069 scopus 로고    scopus 로고
    • Elastic stiffness coefficients (c11, C33, and C13) for freshly excised and formalin-fixed myocardium from ultrasonic velocity measurements
    • Yang M, Baldwin SL, Marutyan KR, Wallace KD, Holland MR, Miller JG. Elastic stiffness coefficients (c11, C33, and C13) for freshly excised and formalin-fixed myocardium from ultrasonic velocity measurements. J Acoust Soc Am 2006, 119:1880-1887.
    • (2006) J Acoust Soc Am , vol.119 , pp. 1880-1887
    • Yang, M.1    Baldwin, S.L.2    Marutyan, K.R.3    Wallace, K.D.4    Holland, M.R.5    Miller, J.G.6
  • 54
    • 34248222257 scopus 로고    scopus 로고
    • T2 measurement of the human myocardium using a T2-prepared transient-state TrueFISP sequence
    • Huang TY, Liu YJ, Stemmer A, Poncelet BP. T2 measurement of the human myocardium using a T2-prepared transient-state TrueFISP sequence. Magn Reson Med 2007, 57:960-966.
    • (2007) Magn Reson Med , vol.57 , pp. 960-966
    • Huang, T.Y.1    Liu, Y.J.2    Stemmer, A.3    Poncelet, B.P.4
  • 55
    • 0032963505 scopus 로고    scopus 로고
    • Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: assessment using T*2 and T1 measurements
    • Wacker CM, Bock M, Hartlep AW, Beck G, van Kaick G, Ertl G, Bauer WR, Schad LR. Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: assessment using T*2 and T1 measurements. Magn Reson Med 1999, 41:686-695.
    • (1999) Magn Reson Med , vol.41 , pp. 686-695
    • Wacker, C.M.1    Bock, M.2    Hartlep, A.W.3    Beck, G.4    van Kaick, G.5    Ertl, G.6    Bauer, W.R.7    Schad, L.R.8
  • 56
    • 0032706560 scopus 로고    scopus 로고
    • Characterization of t1 relaxation and blood-myocardial contrast enhancement of NC100150 injection in cardiac MRI
    • Wagenseil JE, Johansson LO, Lorenz CH. Characterization of t1 relaxation and blood-myocardial contrast enhancement of NC100150 injection in cardiac MRI. J Magn Reson Imaging 1999, 10:784-789.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 784-789
    • Wagenseil, J.E.1    Johansson, L.O.2    Lorenz, C.H.3
  • 60
    • 84867320829 scopus 로고    scopus 로고
    • Assessment of mechanical properties of isolated bovine intervertebral discs from multi-parametric Magnetic Resonance Imaging
    • Recuerda M, Perie D, Gilbert G, Beaudoin G. Assessment of mechanical properties of isolated bovine intervertebral discs from multi-parametric Magnetic Resonance Imaging. BMC Musculoskelet Disord 2012, 13:95.
    • (2012) BMC Musculoskelet Disord , vol.13 , pp. 95
    • Recuerda, M.1    Perie, D.2    Gilbert, G.3    Beaudoin, G.4
  • 61
    • 84875909220 scopus 로고    scopus 로고
    • Assessment of mechanical properties of muscles from multi-parametric Magnetic Resonance Imaging
    • In press
    • Grenier R, Perie D, Gilbert G, Beaudoin G, Curnier D. Assessment of mechanical properties of muscles from multi-parametric Magnetic Resonance Imaging. J Biomed Sci Eng 2013, In press.
    • (2013) J Biomed Sci Eng
    • Grenier, R.1    Perie, D.2    Gilbert, G.3    Beaudoin, G.4    Curnier, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.