메뉴 건너뛰기




Volumn 42, Issue 4, 2013, Pages 521-526

Rehabilitation of edentulous posterior atrophic mandible: Inferior alveolar nerve lateralization by piezotome and immediate implant placement

Author keywords

inferior alveolar nerve lateralization; piezotome; posterior mandibular atrophy; ultrasonic bone cutting

Indexed keywords

AMOXICILLIN PLUS CLAVULANIC ACID; CHLORHEXIDINE; CLINDAMYCIN; KETOPROFEN;

EID: 84875211397     PISSN: 09015027     EISSN: 13990020     Source Type: Journal    
DOI: 10.1016/j.ijom.2012.10.015     Document Type: Article
Times cited : (32)

References (21)
  • 1
    • 3042606728 scopus 로고    scopus 로고
    • Alveolar distraction osteogenesis for the correction of vertically deficient edentulous ridges: A multicenter prospective study on humans
    • M. Chiapasco, U. Consolo, A. Bianchi, and P. Ronchi Alveolar distraction osteogenesis for the correction of vertically deficient edentulous ridges: a multicenter prospective study on humans Int J Oral Maxillofac Implants 19 2004 399 407
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 399-407
    • Chiapasco, M.1    Consolo, U.2    Bianchi, A.3    Ronchi, P.4
  • 2
    • 79955002690 scopus 로고    scopus 로고
    • Implant rehabilitation of the edentulous posterior atrophic mandible: The sandwich osteotomy revisited
    • J.L. López-Cedrún Implant rehabilitation of the edentulous posterior atrophic mandible: the sandwich osteotomy revisited Int J Oral Maxillofac Implants 26 2011 195 202
    • (2011) Int J Oral Maxillofac Implants , vol.26 , pp. 195-202
    • López-Cedrún, J.L.1
  • 3
    • 0030155754 scopus 로고    scopus 로고
    • Long-term stability of osseointegrated implants in bone regenerated with the membrane technique, 5-year results of a prospective study with 12 implants
    • D. Buser, K. Dula, N.P. Lang, and S. Nyman Long-term stability of osseointegrated implants in bone regenerated with the membrane technique, 5-year results of a prospective study with 12 implants Clin Oral Implants Res 7 1996 175 183
    • (1996) Clin Oral Implants Res , vol.7 , pp. 175-183
    • Buser, D.1    Dula, K.2    Lang, N.P.3    Nyman, S.4
  • 4
    • 0026297569 scopus 로고
    • Membrane-induced bone augmentation at titanium implants. A report on ten fixtures followed from 1 to 3 years after loading
    • C. Dahlin, U. Lekholm, and A. Linde Membrane-induced bone augmentation at titanium implants. A report on ten fixtures followed from 1 to 3 years after loading Int J Periodontics Restorative Dent 11 1991 273 281
    • (1991) Int J Periodontics Restorative Dent , vol.11 , pp. 273-281
    • Dahlin, C.1    Lekholm, U.2    Linde, A.3
  • 5
    • 2142806762 scopus 로고    scopus 로고
    • Vertical alveolar ridge augmentation by means of a titanium mesh and autogenous bone grafts
    • M. Roccuzzo, G. Ramieri, M.C. Spada, S.D. Bianchi, and S. Berrone Vertical alveolar ridge augmentation by means of a titanium mesh and autogenous bone grafts Clin Oral Implants Res 15 2004 73 81
    • (2004) Clin Oral Implants Res , vol.15 , pp. 73-81
    • Roccuzzo, M.1    Ramieri, G.2    Spada, M.C.3    Bianchi, S.D.4    Berrone, S.5
  • 6
    • 0033070128 scopus 로고    scopus 로고
    • Implant placement and simultaneous ridge augmentation using autogenous bone and a micro titanium mesh: A prospective clinical study with 20 implants
    • T. Von Arx, and B. Kurt Implant placement and simultaneous ridge augmentation using autogenous bone and a micro titanium mesh: a prospective clinical study with 20 implants Clin Oral Implants Res 10 1999 24 33
    • (1999) Clin Oral Implants Res , vol.10 , pp. 24-33
    • Von Arx, T.1    Kurt, B.2
  • 7
    • 25444504835 scopus 로고    scopus 로고
    • Inferior alveolar nerve transposition in conjunction with implant placement
    • N. Ferrigno, M. Laureti, and S. Fanali Inferior alveolar nerve transposition in conjunction with implant placement Int J Oral Maxillofac Implants 20 2005 610 620
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 610-620
    • Ferrigno, N.1    Laureti, M.2    Fanali, S.3
  • 8
    • 77952110656 scopus 로고    scopus 로고
    • Neurosensory function following mandibular nerve lateralization for placement of implants
    • H.M. Hashemi Neurosensory function following mandibular nerve lateralization for placement of implants Int J Oral Maxillofac Surg 39 2010 452 456
    • (2010) Int J Oral Maxillofac Surg , vol.39 , pp. 452-456
    • Hashemi, H.M.1
  • 9
    • 84982858982 scopus 로고
    • Implant placement in combination with nerve transpositioning: Experiences with the first 100 cases
    • B. Rosenquist Implant placement in combination with nerve transpositioning: experiences with the first 100 cases Int J Oral Maxillofac Implants 9 1994 522 531
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 522-531
    • Rosenquist, B.1
  • 10
    • 43049112441 scopus 로고    scopus 로고
    • Transposition of the mental nerve by piezosurgery followed by postoperative neurosensory control: A case report
    • N. Sakkas, J. Otten, R. Gutwald, and R. Schmelzeisen Transposition of the mental nerve by piezosurgery followed by postoperative neurosensory control: a case report Br J Oral Maxillofac Surg 46 2008 270 271
    • (2008) Br J Oral Maxillofac Surg , vol.46 , pp. 270-271
    • Sakkas, N.1    Otten, J.2    Gutwald, R.3    Schmelzeisen, R.4
  • 11
    • 0027346437 scopus 로고
    • Repositioning the inferior alveolar nerve for placement of endosseous implants: Technical note
    • D.G. Smiler Repositioning the inferior alveolar nerve for placement of endosseous implants: technical note Int J Oral Maxillofac Implants 8 1993 145 150
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 145-150
    • Smiler, D.G.1
  • 12
    • 14844329980 scopus 로고
    • Problems and complications in implant surgery. The surgeon's perspective
    • R. Beirne, and P. Worthington Problems and complications in implant surgery. The surgeon's perspective Oral Maxillofac Surg Clin North Am-Implants 3 4 1991 993 1000
    • (1991) Oral Maxillofac Surg Clin North Am-Implants , vol.3 , Issue.4 , pp. 993-1000
    • Beirne, R.1    Worthington, P.2
  • 14
    • 4444267748 scopus 로고    scopus 로고
    • ®: An ultrasound device for cutting bone and its use and limitations in maxillofacial surgery
    • ®: an ultrasound device for cutting bone and its use and limitations in maxillofacial surgery Br J Oral Maxillofac Surg 42 2004 451 453
    • (2004) Br J Oral Maxillofac Surg , vol.42 , pp. 451-453
    • Egger, G.1    Klein, J.2    Blank, J.3    Hassfeld, S.4
  • 18
    • 36849065071 scopus 로고    scopus 로고
    • STROBE initiative. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: Guidelines for reporting observational studies
    • E. Von Elm, D.G. Altman, M. Egger, S.J. Pocock, P.C. Gøtzsche, and J.P. Vandenbroucke STROBE initiative. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies Lancet 370 9596 2007 1453 1457
    • (2007) Lancet , vol.370 , Issue.9596 , pp. 1453-1457
    • Von Elm, E.1    Altman, D.G.2    Egger, M.3    Pocock, S.J.4    Gøtzsche, P.C.5    Vandenbroucke, J.P.6
  • 19
    • 0347036012 scopus 로고
    • Neurosensory function after lateralization of the inferior alveolar nerve and simultaneous insertion of implants
    • P.E. Haers, and H.F. Sailer Neurosensory function after lateralization of the inferior alveolar nerve and simultaneous insertion of implants Oral Maxillofac Surg Clin North Am 7 1994 707 716
    • (1994) Oral Maxillofac Surg Clin North Am , vol.7 , pp. 707-716
    • Haers, P.E.1    Sailer, H.F.2
  • 20
    • 0031180902 scopus 로고    scopus 로고
    • Endosseus implant placement in conjunction with inferior alveolar nerve transposition: An evaluation of neurosensory disturbance
    • J.Y. Kan, J.L. Lozada, C.J. Goodacre, W.H. Davis, and O. Hanisch Endosseus implant placement in conjunction with inferior alveolar nerve transposition: an evaluation of neurosensory disturbance Int J Oral Maxillofac Implants 12 1997 463 471
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 463-471
    • Kan, J.Y.1    Lozada, J.L.2    Goodacre, C.J.3    Davis, W.H.4    Hanisch, O.5
  • 21
    • 41449097407 scopus 로고    scopus 로고
    • Anatomical variation in arterial supply of the mandible with special regard to implant placement
    • M. Loukas, C.R. Kinsella, T. Kapos, R.S. Tubbs, and S. Ramachandra Anatomical variation in arterial supply of the mandible with special regard to implant placement Int J Oral Maxillofac Surg 37 2008 367 371
    • (2008) Int J Oral Maxillofac Surg , vol.37 , pp. 367-371
    • Loukas, M.1    Kinsella, C.R.2    Kapos, T.3    Tubbs, R.S.4    Ramachandra, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.