메뉴 건너뛰기




Volumn 23, Issue 1, 2013, Pages 17-23

Magnetic resonance imaging of cranial nerves at 7 tesla

Author keywords

Artifacts; Cranial nerves; Diagnostic imaging; Image enhancement; Imaging, three dimensional

Indexed keywords

ABDUCENS NERVE; ACCESSORY NERVE; ADULT; ARTICLE; ARTIFACT; CEREBROSPINAL FLUID; CONTRAST ENHANCEMENT; CONTROLLED STUDY; CRANIAL NERVE; DIFFUSION WEIGHTED IMAGING; FACIAL NERVE; FEASIBILITY STUDY; FEMALE; GLOSSOPHARYNGEAL NERVE; HUMAN; HUMAN EXPERIMENT; HYPOGLOSSAL NERVE; IMAGE ANALYSIS; MAGNETIC FIELD; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; OLFACTORY NERVE; OPTIC NERVE; STEADY STATE; TRIGEMINAL NERVE; TROCHLEAR NERVE; VAGUS NERVE; VESTIBULOCOCHLEAR NERVE; VOLUNTEER;

EID: 84874948329     PISSN: 18691439     EISSN: 18691447     Source Type: Journal    
DOI: 10.1007/s00062-012-0144-3     Document Type: Article
Times cited : (21)

References (17)
  • 1
    • 0027511172 scopus 로고
    • Constructive interference in steady state-3DFT MR imaging of the inner ear and cerebellopontine angle
    • 8427111 1:STN:280:DyaK3s7ltFSrsg%3D%3D
    • Casselman JW, Kuhweide R, Deimling M, Ampe W, Dehaene I, Meeus L. Constructive interference in steady state-3DFT MR imaging of the inner ear and cerebellopontine angle. AJNR Am J Neuroradiol. 1993;14(1):47-57.
    • (1993) AJNR Am J Neuroradiol. , vol.14 , Issue.1 , pp. 47-57
    • Casselman, J.W.1    Kuhweide, R.2    Deimling, M.3    Ampe, W.4    Dehaene, I.5    Meeus, L.6
  • 2
    • 39049161283 scopus 로고    scopus 로고
    • Three-dimensional-fast imaging employing steady-state acquisition and T2-weighted fast spin-echo magnetic resonance sequences on visualization of cranial nerves III-XII
    • Cheng YS, Zhou ZR, Peng WJ, Tang F. Three-dimensional-fast imaging employing steady-state acquisition and T2-weighted fast spin-echo magnetic resonance sequences on visualization of cranial nerves III-XII. Chin Med J (Engl). 2008;121(3):276-9.
    • (2008) Chin Med J (Engl). , vol.121 , Issue.3 , pp. 276-279
    • Cheng, Y.S.1    Zhou, Z.R.2    Peng, W.J.3    Tang, F.4
  • 3
    • 58249140844 scopus 로고    scopus 로고
    • The jugular foramen: Imaging strategy and detailed anatomy at 3 T
    • 18832666 10.3174/ajnr.A1281 1:STN:280:DC%2BD1M%2FmsFalsA%3D%3D
    • Linn J, Peters F, Moriggl B, Naidich TP, Bruckmann H, Yousry I. The jugular foramen: imaging strategy and detailed anatomy at 3 T. AJNR Am J Neuroradiol. 2009;30(1):34-41.
    • (2009) AJNR Am J Neuroradiol. , vol.30 , Issue.1 , pp. 34-41
    • Linn, J.1    Peters, F.2    Moriggl, B.3    Naidich, T.P.4    Bruckmann, H.5    Yousry, I.6
  • 4
    • 40449090101 scopus 로고    scopus 로고
    • 3-T imaging of the cranial nerves using three-dimensional reversed FISP with diffusion-weighted MR sequence
    • 18219629 10.1002/jmri.21009
    • Zhang Z, Meng Q, Chen Y, Li Z, Luo B, Yang Z, et al. 3-T imaging of the cranial nerves using three-dimensional reversed FISP with diffusion-weighted MR sequence. J Magn Reson Imaging. 2008;27(3):454-8.
    • (2008) J Magn Reson Imaging. , vol.27 , Issue.3 , pp. 454-458
    • Zhang, Z.1    Meng, Q.2    Chen, Y.3    Li, Z.4    Luo, B.5    Yang, Z.6
  • 5
    • 0030996886 scopus 로고    scopus 로고
    • MRI of inner ear anatomy using 3D MP-RAGE and 3D CISS sequences
    • 9227227 1:STN:280:DyaK2szntFSjsA%3D%3D
    • Held P, Fellner C, Fellner F, Seitz J, Strutz J. MRI of inner ear anatomy using 3D MP-RAGE and 3D CISS sequences. Br J Radiol. 1997;70(833):465-72.
    • (1997) Br J Radiol. , vol.70 , Issue.833 , pp. 465-472
    • Held, P.1    Fellner, C.2    Fellner, F.3    Seitz, J.4    Strutz, J.5
  • 6
    • 42449105362 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the cranial nerves in the posterior fossa: A comparative study of t2-weighted spin-echo sequences at 1.5 and 3.0 T
    • 18365827 10.1080/02841850701824127 1:STN:280:DC%2BD1c3gvVKksw%3D%3D
    • Fischbach F, Muller M, Bruhn H. Magnetic resonance imaging of the cranial nerves in the posterior fossa: a comparative study of t2-weighted spin-echo sequences at 1.5 and 3.0 T. Acta Radiol. 2008;49(3):358-63.
    • (2008) Acta Radiol. , vol.49 , Issue.3 , pp. 358-363
    • Fischbach, F.1    Muller, M.2    Bruhn, H.3
  • 7
    • 84874950290 scopus 로고    scopus 로고
    • 8-channel transmit/receive head coil for 7 T human imaging using intrinsically decoupled strip line elements with meanders
    • 18-24 April; Honolulu, Hawaii
    • Orzada S, Kraff O, Schäfer LC, Brote I, Bahr A, Bolz T, et al., editors. 8-channel transmit/receive head coil for 7 T human imaging using intrinsically decoupled strip line elements with meanders. ISMRM 17th Scientific Meeting & Exhibition; 2009 18-24 April; Honolulu, Hawaii.
    • (2009) ISMRM 17th Scientific Meeting & Exhibition
    • Orzada S, K.1
  • 8
    • 0033949095 scopus 로고    scopus 로고
    • Visualization of cranial nerves I - XII: Value of 3D CISS and T2-weighted FSE sequences
    • 11003398 10.1007/s003300000452 1:STN:280:DC%2BD3cvkvFCitA%3D%3D
    • Yousry I, Camelio S, Schmid UD, Horsfield MA, Wiesmann M, Bruckmann H, et al. Visualization of cranial nerves I - XII: value of 3D CISS and T2-weighted FSE sequences. Eur Radiol. 2000;10(7):1061-7.
    • (2000) Eur Radiol. , vol.10 , Issue.7 , pp. 1061-1067
    • Yousry, I.1    Camelio, S.2    Schmid, U.D.3    Horsfield, M.A.4    Wiesmann, M.5    Bruckmann, H.6
  • 9
    • 0031884958 scopus 로고    scopus 로고
    • Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at 2 T
    • 9500281 10.1002/jmri.1880080134 1:STN:280:DyaK1c7lvF2itQ%3D%3D
    • Duerk JL, Lewin JS, Wendt M, Petersilge C. Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at 2 T. J Magn Reson Imaging. 1998;8(1):203-8.
    • (1998) J Magn Reson Imaging. , vol.8 , Issue.1 , pp. 203-208
    • Duerk, J.L.1    Lewin, J.S.2    Wendt, M.3    Petersilge, C.4
  • 12
    • 70350704512 scopus 로고    scopus 로고
    • High-resolution MRI of the human parotid gland and duct at 7 Tesla
    • 19652615 10.1097/RLI.0b013e3181b4c0cf
    • Kraff O, Theysohn JM, Maderwald S, Kokulinsky PC, Dogan Z, Kerem A, et al. High-resolution MRI of the human parotid gland and duct at 7 Tesla. Invest Radiol. 2009;44(9):518-24.
    • (2009) Invest Radiol. , vol.44 , Issue.9 , pp. 518-524
    • Kraff, O.1    Theysohn, J.M.2    Maderwald, S.3    Kokulinsky, P.C.4    Dogan, Z.5    Kerem, A.6
  • 13
    • 41149173240 scopus 로고    scopus 로고
    • Identification of the normal jugular foramen and lower cranial nerve anatomy: Contrast-enhanced 3D fast imaging employing steady-state acquisition MR imaging
    • 18065504 10.3174/ajnr.A0860 1:STN:280:DC%2BD1c7ps1Sluw%3D%3D
    • Davagnanam I, Chavda SV. Identification of the normal jugular foramen and lower cranial nerve anatomy: contrast-enhanced 3D fast imaging employing steady-state acquisition MR imaging. AJNR Am J Neuroradiol. 2008;29(3):574-6.
    • (2008) AJNR Am J Neuroradiol. , vol.29 , Issue.3 , pp. 574-576
    • Davagnanam, I.1    Chavda, S.V.2
  • 14
    • 30544444729 scopus 로고    scopus 로고
    • Normal cranial nerves in the cavernous sinuses: Contrast-enhanced three-dimensional constructive interference in the steady state MR imaging
    • 15814950
    • Yagi A, Sato N, Taketomi A, Nakajima T, Morita H, Koyama Y, et al. Normal cranial nerves in the cavernous sinuses: contrast-enhanced three-dimensional constructive interference in the steady state MR imaging. AJNR Am J Neuroradiol. 2005;26(4):946-50.
    • (2005) AJNR Am J Neuroradiol , vol.26 , Issue.4 , pp. 946-950
    • Yagi, A.1    Sato, N.2    Taketomi, A.3    Nakajima, T.4    Morita, H.5    Koyama, Y.6
  • 15
    • 77953487857 scopus 로고    scopus 로고
    • High-resolution 3D MR imaging of the trochlear nerve
    • 20093316 10.3174/ajnr.A1992 1:STN:280:DC%2BC3cvps1Kmsw%3D%3D
    • Choi BS, Kim JH, Jung C, Hwang JM. High-resolution 3D MR imaging of the trochlear nerve. AJNR Am J Neuroradiol. 2010;31(6):1076-9.
    • (2010) AJNR Am J Neuroradiol. , vol.31 , Issue.6 , pp. 1076-1079
    • Choi, B.S.1    Kim, J.H.2    Jung, C.3    Hwang, J.M.4
  • 16
    • 33745685594 scopus 로고    scopus 로고
    • 32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry
    • 16767762 10.1002/mrm.20925 1:STN:280:DC%2BD28zoslOltw%3D%3D
    • Wiggins GC, Triantafyllou C, Potthast A, Reykowski A, Nittka M, Wald LL. 32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry. Magn Reson Med. 2006;56(1):216-23.
    • (2006) Magn Reson Med. , vol.56 , Issue.1 , pp. 216-223
    • Wiggins, G.C.1    Triantafyllou, C.2    Potthast, A.3    Reykowski, A.4    Nittka, M.5    Wald, L.L.6
  • 17
    • 84855296128 scopus 로고    scopus 로고
    • Caudal image contrast inversion in MPRAGE at 7 Tesla: Problem and solution
    • 22104286 10.1016/j.acra.2011.10.004
    • Wrede KH, Johst S, Dammann P, Umutlu L, Schlamann MU, Sandalcioglu IE, et al. Caudal image contrast inversion in MPRAGE at 7 Tesla: problem and solution. Acad Radiol. 2012;19(2):172-8.
    • (2012) Acad Radiol. , vol.19 , Issue.2 , pp. 172-178
    • Wrede, K.H.1    Johst, S.2    Dammann, P.3    Umutlu, L.4    Schlamann, M.U.5    Sandalcioglu, I.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.