Volumn 49, Issue 3, 2008, Pages 358-363

Magnetic resonance imaging of the cranial nerves in the posterior fossa: A comparative study of t2-weighted spin-echo sequences at 1.5 and 3.0 tesla

Author keywords

Anatomy; brain brainstem; CNS; MR imaging

Indexed keywords

IMAGE ENHANCEMENT; IMAGE QUALITY; QUALITY CONTROL; SIGNAL TO NOISE RATIO;

EID: 42449105362     PISSN: 02841851     EISSN: 16000455     Source Type: Journal    
DOI: 10.1080/02841850701824127     Document Type: Article
Times cited : (31)

References (16)
  • 2
    • 0038236731 scopus 로고    scopus 로고
    • Magnetic resonance imaging at 3.0 Tesla: Challenges and advantages in clinical neurological imaging
    • DOI 10.1097/00004424-200307000-00003
    • Frayne R, Goodyear BG, Dickhoff P. Magnetic resonance imaging at 3.0 Tesla: challenges and advantages in clinical neurological imaging. Invest Radiol 2003;38:385-402. (Pubitemid 36791332)
    • (2003) Investigative Radiology , vol.38 , Issue.7 , pp. 385-402
    • Frayne, R.1    Goodyear, B.G.2    Dickhoff, P.3    Lauzon, M.L.4    Sevick, R.J.5
  • 3
    • 12244295766 scopus 로고    scopus 로고
    • MR imaging at high magnetic fields
    • DOI 10.1016/S0720-048X(02)00331-5, PII S0720048X02003315
    • Takahashi M, Uematsu H, Hatabu H. MR imaging at high magnetic fields. Eur J Radiol 2003;46:45-52. (Pubitemid 36332078)
    • (2003) European Journal of Radiology , vol.46 , Issue.1 , pp. 45-52
    • Takahashi, M.1    Uematsu, H.2    Hatabu, H.3
  • 5
    • 0021015974 scopus 로고
    • Nuclear magnetic resonance imaging: Contrast-to-noise ratio as a function of strength of magnetic field
    • Hart HR Jr, Bottomley PA, Edelstein WA. Nuclear magnetic resonance imaging: contrast-to-noise ratio as a function of strength of magnetic field. Am J Roentgenol 1983;141:1195-201. (Pubitemid 14210848)
    • (1983) American Journal of Roentgenology , vol.141 , Issue.6 , pp. 1195-1201
    • Hart Jr., H.R.1    Bottomley, P.A.2    Edelstein, W.A.3
  • 6
    • 0345257074 scopus 로고    scopus 로고
    • Vascular compression in glossopharyngeal neuralgia: Demonstration by high-resolution MRI at 3 tesla
    • DOI 10.1007/s00234-003-1078-x
    • Fischbach F, Lehmann TN, Ricke J, Bruhn H. Vascular compression in glossopharyngeal neuralgia: demonstration by high-resolution MRI at 3 Tesla. Neuroradiology 2003;45:810-1. (Pubitemid 37455677)
    • (2003) Neuroradiology , vol.45 , Issue.11 , pp. 810-811
    • Fischbach, F.1    Lehmann, T.N.2    Ricke, J.3    Bruhn, H.4
  • 7
    • 0003627666 scopus 로고    scopus 로고
    • Nonparametric analysis of longitudinal data in factorial experiments
    • Munic: Wiley-Interscience
    • Brunner L, Langer F. Nonparametric analysis of longitudinal data in factorial experiments. Wiley series in probability and statistics. Munic: Wiley-Interscience; 2001. p. 288.
    • (2001) Wiley Series in Probability and Statistics , pp. 288
    • Brunner, L.1    Langer, F.2
  • 10
    • 0036211031 scopus 로고    scopus 로고
    • MR anatomy of the proximal cisternal segment of the trochlear nerve: Neurovascular relationships and landmarks
    • Yousry I, Moriggl B, Dieterich M. MR anatomy of the proximal cisternal segment of the trochlear nerve: neurovascular relationships and landmarks. Radiology 2002;223:31-8. (Pubitemid 34258187)
    • (2002) Radiology , vol.223 , Issue.1 , pp. 31-38
    • Yousry, I.1    Moriggl, B.2    Dieterich, M.3    Naidich, T.P.4    Schmid, U.D.5    Yousry, T.A.6
  • 11
    • 2142823644 scopus 로고    scopus 로고
    • 3-T Imaging of the Cochlear Nerve and Labyrinth in Cochlear-Implant Candidates: 3D Fast Recovery Fast Spin-Echo versus 3D Constructive Interference in the Steady State Techniques
    • Lane JI, Ward H, Witte RJ. 3-T imaging of the cochlear nerve and labyrinth in cochlear-implant candidates: 3D fast recovery fast spin-echo versus 3D constructive interference in the steady state techniques. Am J Neuroradiol 2004;25:618-22. (Pubitemid 38541942)
    • (2004) American Journal of Neuroradiology , vol.25 , Issue.4 , pp. 618-622
    • Lane, J.I.1    Ward, H.2    Witte, R.J.3    Bernstein, M.A.4    Driscoll, C.L.W.5
  • 12
    • 0033810130 scopus 로고    scopus 로고
    • Ultra high resolution imaging of the human head at 8 tesla: 2K×2K for Y2K
    • Robitaille PM, Abduljalil AM, Kangarlu A. Ultra high resolution imaging of the human head at 8 tesla: 2K×2K for Y2K. J Comput Assist Tomogr 2000;24:2-8.
    • (2000) J Comput Assist Tomogr , vol.24 , pp. 2-8
    • Robitaille, P.M.1    Abduljalil, A.M.2    Kangarlu, A.3
  • 13
    • 0021152307 scopus 로고
    • A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and age
    • DOI 10.1118/1.595535
    • Bottomley PA, Foster TH, Argersinger RE, Pfeiler LM. A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age. Med Phys 1984;11:425-48. (Pubitemid 14057394)
    • (1984) Medical Physics , vol.11 , Issue.4 , pp. 425-448
    • Bottomley, P.A.1    Foster, T.H.2    Argersinger, R.E.3    Pfeifer, L.M.4
  • 15
    • 0034951155 scopus 로고    scopus 로고
    • MR cisternography of the cerebellopontine angle: Comparison of three-dimensional fast asymmetrical spin-echo and three-dimensional constructive interference in the steady-state sequences
    • Naganawa S, Koshikawa T, Fukatsu H. MR cisternography of the cerebellopontine angle: comparison of three-dimensional constructive interference in the steady-state sequences. Am J Neuroradiol 2001;22:1179-85. (Pubitemid 32587434)
    • (2001) American Journal of Neuroradiology , vol.22 , Issue.6 , pp. 1179-1185
    • Naganawa, S.1    Koshikawa, T.2    Fukatsu, H.3    Ishigaki, T.4    Fukuta, T.5
  • 16
    • 2442657865 scopus 로고    scopus 로고
    • Three-dimensional visualization of neurovascular relationships in the posterior fossa: Technique and clinical application
    • Naraghi R, Hastreiter P, Tomandi B. Three-dimensional visualization of neurovascular relationships in the posterior fossa: technique and clinical application. J Neurosurg 2004;100:1025-35. (Pubitemid 38661615)
    • (2004) Journal of Neurosurgery , vol.100 , Issue.6 , pp. 1025-1035
    • Naraghi, R.1    Hastreiter, P.2    Tomandl, B.3    Bonk, A.4    Huk, W.5    Fahlbusch, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.