메뉴 건너뛰기




Volumn 1, Issue 3, 2008, Pages 140-144

Replacement of congenically missing maxillary permanent canine with a zirconium oxide dental implant and crown. A case report from an ongoing clinical study

Author keywords

Acid etched; Agenesia; Implant; Rough; Zirconia; Zirconium oxide

Indexed keywords


EID: 84874699778     PISSN: 17522471     EISSN: 1752248X     Source Type: Journal    
DOI: 10.1111/j.1752-248X.2008.00029.x     Document Type: Article
Times cited : (5)

References (25)
  • 1
    • 0024201328 scopus 로고
    • Biomaterial and implant surfaces: a surface science approach
    • Kasemo B, Lausmaa J. Biomaterial and implant surfaces: a surface science approach. Int J Oral Maxillofac Implants 1988;3:247-59.
    • (1988) Int J Oral Maxillofac Implants , vol.3 , pp. 247-59
    • Kasemo, B.1    Lausmaa, J.2
  • 2
    • 0039398377 scopus 로고
    • Naert I, van Steenberghe D,Worthington P, editors. Osseointegration in Oral Rehabilitation. London: Quintessence,
    • Kasemo B, Lausmaa J. Biomaterials and interfaces. In: Naert I, van Steenberghe D,Worthington P, editors. Osseointegration in Oral Rehabilitation. London: Quintessence, 1993:63-75.
    • (1993) Biomaterials and interfaces , pp. 63-75
    • Kasemo, B.1    Lausmaa, J.2
  • 3
    • 0033094778 scopus 로고    scopus 로고
    • Optimal aesthetics in single-tooth replacement with the re-implant system: a case report
    • Heydecke G, Kohal R, Glaser R. Optimal aesthetics in single-tooth replacement with the re-implant system: a case report. Int J Prosthodont 1999;12:184-9.
    • (1999) Int J Prosthodont , vol.12 , pp. 184-9
    • Heydecke, G.1    Kohal, R.2    Glaser, R.3
  • 4
    • 0347510752 scopus 로고    scopus 로고
    • The zirconium oxide abutment - a new all-ceramic concept for esthetically improving suprastructures in implantology (in German)
    • Wohlwend A, Studer S, Schärer P. The zirconium oxide abutment - a new all-ceramic concept for esthetically improving suprastructures in implantology (in German). Quintessenz Zahntech 1996;22:364-81.
    • (1996) Quintessenz Zahntech , vol.22 , pp. 364-81
    • Wohlwend, A.1    Studer, S.2    Schärer, P.3
  • 5
    • 0036381523 scopus 로고    scopus 로고
    • Biological reactivity of zirconia-hydroxyapatite composites
    • Silva VV, Lameiras FS, Lobato ZI. Biological reactivity of zirconia-hydroxyapatite composites. J Biomed Mater Res 2002;63:583-90.
    • (2002) J Biomed Mater Res , vol.63 , pp. 583-90
    • Silva, V.V.1    Lameiras, F.S.2    Lobato, Z.I.3
  • 7
    • 0344343514 scopus 로고
    • 13 years of the Tübingen implant system made by Frialit - additional results (in German)
    • Schulte W, d'Hoedt B. 13 years of the Tübingen implant system made by Frialit - additional results (in German). Z Zahnärztl Implantol 1988;3:167-72.
    • (1988) Z Zahnärztl Implantol , vol.3 , pp. 167-72
    • Schulte, W.1    D'Hoedt, B.2
  • 9
    • 0040452008 scopus 로고
    • Modern ceramic materials for esthetic restorations - strengthening and fracture toughness (in German)
    • Marx R. Modern ceramic materials for esthetic restorations - strengthening and fracture toughness (in German). Dtsch Zahnärztl Z 1993;48:229-36.
    • (1993) Dtsch Zahnärztl Z , vol.48 , pp. 229-36
    • Marx, R.1
  • 10
    • 0032144008 scopus 로고    scopus 로고
    • Y-TZP ceramics for artificial joint replacements
    • Piconi C, Burger W, RichterHGet al. Y-TZP ceramics for artificial joint replacements. Biomaterials 1998;19:1489-94.
    • (1998) Biomaterials , vol.19 , pp. 1489-94
    • Piconi, C.1    Burger, W.2    Richter, H.G.3
  • 11
    • 7044259005 scopus 로고    scopus 로고
    • Zirconia and Zirconia Ceramics
    • An Introduction to Zirconia, 2nd edition.
    • Stevens R. Zirconia and Zirconia Ceramics. An Introduction to Zirconia, 2nd edition. Twickenham: Litho, 2000:1-51.
    • (2000) Twickenham: Litho , pp. 1-51
    • Stevens, R.1
  • 12
    • 13144290924 scopus 로고    scopus 로고
    • Threshold intensity factors as lower boundaries for crack propagation in ceramics
    • Marx R, Jungwirth F,Walter P. Threshold intensity factors as lower boundaries for crack propagation in ceramics. Biomed Eng Online 2004;3:41.
    • (2004) Biomed Eng Online , vol.3 , pp. 41
    • Marx, R.1    Jungwirth, F.2    Walter, P.3
  • 13
    • 0021963531 scopus 로고
    • Interface analysis of titanium and zirconium bone implants
    • Albrektsson T, Hansson HA, Ivarsson B. Interface analysis of titanium and zirconium bone implants. Biomaterials 1985;6:97-101.
    • (1985) Biomaterials , vol.6 , pp. 97-101
    • Albrektsson, T.1    Hansson, H.A.2    Ivarsson, B.3
  • 14
    • 0027613970 scopus 로고
    • Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing
    • Akagawa Y, Ichikawa Y, Nikai H, Tsuru H. Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing. J Prosthet Dent 1993;69:599-604.
    • (1993) J Prosthet Dent , vol.69 , pp. 599-604
    • Akagawa, Y.1    Ichikawa, Y.2    Nikai, H.3    Tsuru, H.4
  • 15
    • 0032199149 scopus 로고    scopus 로고
    • Comparison between freestanding and tooth-connected partially stabilized zirconia implants after two years' function in monkeys: a clinical and histological study
    • Akagawa Y, Hosokawa R, Sato Y, Kamayama K. Comparison between freestanding and tooth-connected partially stabilized zirconia implants after two years' function in monkeys: a clinical and histological study. J Prosthet Dent 1998;80:551-8.
    • (1998) J Prosthet Dent , vol.80 , pp. 551-8
    • Akagawa, Y.1    Hosokawa, R.2    Sato, Y.3    Kamayama, K.4
  • 16
    • 0026902233 scopus 로고
    • Tissue compatibility and stability of a new zirconia ceramic in vivo
    • Ichikawa Y, Akagawa Y, Nikai H, Tsuru H. Tissue compatibility and stability of a new zirconia ceramic in vivo. J Prosthet Dent 1992;68:322-6.
    • (1992) J Prosthet Dent , vol.68 , pp. 322-6
    • Ichikawa, Y.1    Akagawa, Y.2    Nikai, H.3    Tsuru, H.4
  • 17
    • 0036516450 scopus 로고    scopus 로고
    • Three-dimensional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants
    • Kohal RJ, Papavasiliou G, Kamposiora P, Tripodakis A, Strub JR. Three-dimensional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants. Int J Prosthodont 2002;15:189-94.
    • (2002) Int J Prosthodont , vol.15 , pp. 189-94
    • Kohal, R.J.1    Papavasiliou, G.2    Kamposiora, P.3    Tripodakis, A.4    Strub, J.R.5
  • 18
  • 19
    • 7044246252 scopus 로고    scopus 로고
    • Loaded custom-made zirconia and titanium implants show similar osseointegration
    • Kohal RJ, Weng D, Bächle M, Strub J. Loaded custom-made zirconia and titanium implants show similar osseointegration. J Periodontol 2004;75:1262-8.
    • (2004) J Periodontol , vol.75 , pp. 1262-8
    • Kohal, R.J.1    Weng, D.2    Bächle, M.3    Strub, J.4
  • 20
    • 20744457194 scopus 로고    scopus 로고
    • Bone tissue responses to surface-modified zirconia implants: a histomorphometric and removal torque study in the rabbit
    • Senerby L, Dasmah A, Larsson B, Iverhed M. Bone tissue responses to surface-modified zirconia implants: a histomorphometric and removal torque study in the rabbit. Clin Implant Dent Relat Res 2005;7(Suppl. 1):s13-s20.
    • (2005) Clin Implant Dent Relat Res , vol.7 , Issue.SUPPL. 1
    • Senerby, L.1    Dasmah, A.2    Larsson, B.3    Iverhed, M.4
  • 21
    • 47649129098 scopus 로고    scopus 로고
    • Survival rate and fracture resistance of zirconium dioxide implants after exposure to the artificial mouth: an in-vitro study
    • Inaugural - Dissertation. Thesis. Universitat Freiburg.
    • Andreiotelli M. Survival rate and fracture resistance of zirconium dioxide implants after exposure to the artificial mouth: an in-vitro study. Inaugural - Dissertation. Thesis. Universitat Freiburg. 2006
    • (2006)
    • Andreiotelli, M.1
  • 22
    • 1842610851 scopus 로고    scopus 로고
    • A zirconia implant/zirconia crown system. A case report
    • Kohal RJ, Klaus G. A zirconia implant/zirconia crown system. A case report. Int J Periodontics Restorative Dent 2004;24:147-53.
    • (2004) Int J Periodontics Restorative Dent , vol.24 , pp. 147-53
    • Kohal, R.J.1    Klaus, G.2
  • 23
    • 0004122848 scopus 로고    scopus 로고
    • On surface roughness and implant incorporation
    • University Göteborg, Göteborg, Sweden
    • Wennerberg A. On surface roughness and implant incorporation. Thesis. University Göteborg, Göteborg, Sweden 1996.
    • (1996) Thesis
    • Wennerberg, A.1
  • 24
    • 34548663648 scopus 로고    scopus 로고
    • Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs
    • Gahlert M, Gudehus T, Eichhorn S, Steinhauser E, Knia H, ErhardtW. Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs. Clin Oral Implants Res 2007;18:662-8.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 662-8
    • Gahlert, M.1    Gudehus, T.2    Eichhorn, S.3    Steinhauser, E.4    Knia, H.5    Erhardt, W.6
  • 25
    • 34547357206 scopus 로고    scopus 로고
    • One year follow-up of first consecutive 100 zirconia dental implants in humans A comparison of two different rough surfaces
    • Oliva J, Oliva X, Oliva DJ. One year follow-up of first consecutive 100 zirconia dental implants in humans.A comparison of two different rough surfaces. Int J Oral Maxillofac Implants 2007;22:430-5.
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 430-5
    • Oliva, J.1    Oliva, X.2    Oliva, D.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.