메뉴 건너뛰기




Volumn 28, Issue 2, 2013, Pages 109-113

Mechanical left ventricular support using a 50 cc 8 Fr fibre-optic intra-aortic balloon technology: A case report

Author keywords

8 French 50 cc; diastolic blood volume displacement; fibre optic IAB; IABP; left ventricular function; left ventricular support

Indexed keywords

ACETYLSALICYLIC ACID; DIAZEPAM; DOPAMINE; FUROSEMIDE; LANSOPRAZOLE; NORADRENALIN; PARACETAMOL; RAMIPRIL; SIMVASTATIN; SPIRONOLACTONE; THIAMINE; VITAMIN B GROUP;

EID: 84874455624     PISSN: 02676591     EISSN: 1477111X     Source Type: Journal    
DOI: 10.1177/0267659112454912     Document Type: Article
Times cited : (8)

References (12)
  • 1
    • 0036696865 scopus 로고    scopus 로고
    • Ruptured intra-aortic balloon pump. A case report
    • Kirksey L. Ruptured intra-aortic balloon pump. A case report. J Cardiovasc Surg. 2002 ; 43: 461-464
    • (2002) J Cardiovasc Surg , vol.43 , pp. 461-464
    • Kirksey, L.1
  • 3
    • 84874495756 scopus 로고    scopus 로고
    • Fiber-optic intra-aortic balloon therapy and its role as a mechanical assist device
    • Yarham G, Clemments A, Morris C, et al. Fiber-optic intra-aortic balloon therapy and its role as a mechanical assist device. Perfusion. 2012 ;:
    • (2012) Perfusion
    • Yarham, G.1    Clemments, A.2    Morris, C.3
  • 5
    • 0025151764 scopus 로고
    • Origins of intraaortic balloon pumping
    • Kantrowitz A. Origins of intraaortic balloon pumping. Ann Thorac Surg. 1990 ; 50: 672-674 (Pubitemid 20360840)
    • (1990) Annals of Thoracic Surgery , vol.50 , Issue.4 , pp. 672-674
    • Kantrowitz, A.1
  • 6
    • 79960038179 scopus 로고    scopus 로고
    • Intra-aortic balloon pump use and outcomes with current therapies
    • Vales L, Kanei Y, Ephrem G, Misra D. Intra-aortic balloon pump use and outcomes with current therapies. J Invasive Cardiol. 2011 ; 23: 116-119
    • (2011) J Invasive Cardiol , vol.23 , pp. 116-119
    • Vales, L.1    Kanei, Y.2    Ephrem, G.3    Misra, D.4
  • 7
    • 0032726202 scopus 로고    scopus 로고
    • Optimal timing of preoperative intraaortic balloon pump support in high-risk coronary patients
    • DOI 10.1016/S0003-4975(99)00687-6, PII S0003497599006876
    • Christenson J, Simonet F, Badel P, Schmuziger M. Optimal timing of preoperative intraaortic balloon pump support in high-risk coronary patients. Ann Thorac Surg. 1999 ; 68: 934-939 (Pubitemid 29526864)
    • (1999) Annals of Thoracic Surgery , vol.68 , Issue.3 , pp. 934-939
    • Christenson, J.T.1    Simonet, F.2    Badel, P.3    Schmuziger, M.4
  • 10
    • 58849120525 scopus 로고    scopus 로고
    • Principles of intra-aortic balloon pump counterpulsation: Technique of insertion and operation
    • Krishna M, Zacharowski K. Principles of intra-aortic balloon pump counterpulsation: technique of insertion and operation. Cont Edu Anaesth Crit Care Pain. 2009 ; 9: 24-28
    • (2009) Cont Edu Anaesth Crit Care Pain , vol.9 , pp. 24-28
    • Krishna, M.1    Zacharowski, K.2
  • 11
    • 84874457267 scopus 로고    scopus 로고
    • Enhanced augmentation of cardiac output for different counterpulsation modes using a new intra aortic balloon and catheter
    • Boiangiu C, Cohen M. Enhanced augmentation of cardiac output for different counterpulsation modes using a new intra aortic balloon and catheter. Cath Lab Digest. 2010 ;: 18
    • (2010) Cath Lab Digest , pp. 18
    • Boiangiu, C.1    Cohen, M.2
  • 12
    • 79955451552 scopus 로고    scopus 로고
    • Improvement in hemodynamics with a new, larger-volume (50cc) intra-aortic balloon for high-risk percutaneous coronary intervention
    • Nair P, Scolieri S, Lee A. Improvement in hemodynamics with a new, larger-volume (50cc) intra-aortic balloon for high-risk percutaneous coronary intervention. J Invasive Cardiol. 2011 ; 23: 162-166
    • (2011) J Invasive Cardiol , vol.23 , pp. 162-166
    • Nair, P.1    Scolieri, S.2    Lee, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.