Spinal cord stimulation for chronic pain management
-
Barolat G. Spinal cord stimulation for chronic pain management. Arch Med Res. 2000;31(3):258-262.
-
(2000)
Arch Med Res
, vol.31
, Issue.3
, pp. 258-262
-
-
Barolat, G.1
-
2
-
-
0037112270
-
Spinal cord stimulation: Mechanisms of action
-
Oakley JC, Prager JP. Spinal cord stimulation: mechanisms of action. Spine (Phila Pa 1976). 2002;27(22):2574-2583.
-
(2002)
Spine (Phila Pa 1976
, vol.27
, Issue.22
, pp. 2574-2583
-
-
Oakley, J.C.1
Prager, J.P.2
-
3
-
-
0030978901
-
Effectiveness of spinal cord stimulation in the management of chronic pain: Analysis of technical drawbacks and solutions
-
Holsheimer J. Effectiveness of spinal cord stimulation in the management of chronic pain: analysis of technical drawbacks and solutions. Neurosurgery. 1997;40 (5):990-996.
-
(1997)
Neurosurgery
, vol.40
, Issue.5
, pp. 990-996
-
-
Holsheimer, J.1
-
5
-
-
0036098142
-
Four year follow-up of dual electrode spinal cord stimulation for chronic pain
-
Aló KM, Redko V, Charnov J. Four year follow-up of dual electrode spinal cord stimulation for chronic pain. Neuromodulation. 2002;5(2):79-88.
-
(2002)
Neuromodulation
, vol.5
, Issue.2
, pp. 79-88
-
-
Aló, K.M.1
Redko, V.2
Charnov, J.3
-
6
-
-
0026093415
-
Spinal cord stimulation for chronic intractable pain: Superiority of "multi-channel" devices
-
North RB, Ewend MG, Lawton MT, Piantadosi S. Spinal cord stimulation for chronic, intractable pain: superiority of "multi-channel" devices. Pain. 1991;44(2): 119-130.
-
(1991)
Pain
, vol.44
, Issue.2
, pp. 119-130
-
-
North, R.B.1
Ewend, M.G.2
Lawton, M.T.3
Piantadosi, S.4
-
7
-
-
0027719849
-
Spinal cord stimulation for chronic, intractable pain
-
North RB. Spinal cord stimulation for chronic, intractable pain. Adv Neurol. 1993; 63:289-301.
-
(1993)
Adv Neurol
, vol.63
, pp. 289-301
-
-
North, R.B.1
-
8
-
-
18544369146
-
Technical performance of percutaneous leads for spinal cord stimulation: A modeling study
-
Manola L, Holsheimer J, Veltink P. Technical performance of percutaneous leads for spinal cord stimulation: a modeling study. Neuromodulation. 2005;8(2):88-99.
-
(2005)
Neuromodulation
, vol.8
, Issue.2
, pp. 88-99
-
-
Manola, L.1
Holsheimer, J.2
Veltink, P.3
-
9
-
-
33746423939
-
Spinal cord stimulation in axial low back pain: Solving the dilemma
-
Oakley JC. Spinal cord stimulation in axial low back pain: solving the dilemma. Pain Med. 2006;7(S1):S58-S63.
-
(2006)
Pain Med
, vol.7
, Issue.S1
-
-
Oakley, J.C.1
-
10
-
-
0034090114
-
Does dual lead stimulation favor stimulation of the axial lower back?
-
Holsheimer J. Does dual lead stimulation favor stimulation of the axial lower back? Neuromodulation. 2000;3(5):55-57.
-
(2000)
Neuromodulation
, vol.3
, Issue.5
, pp. 55-57
-
-
Holsheimer, J.1
-
11
-
-
0027446231
-
Mapping of sensory responses to epidural stimulation of the intraspinal neural structures in man
-
Barolat G, Massaro F, He J, Zeme S, Ketcik B. Mapping of sensory responses to epidural stimulation of the intraspinal neural structures in man. J Neurosurg. 1993; 78(2):233-239.
-
(1993)
J Neurosurg
, vol.78
, Issue.2
, pp. 233-239
-
-
Barolat, G.1
Massaro, F.2
He, J.3
Zeme, S.4
Ketcik, B.5
-
13
-
-
0021041351
-
Spinal stimulation: Statistical superiority of monophasic stimulation of narrowly separated, longitudinal bipoles having rostral cathodes
-
Law JD. Spinal stimulation: statistical superiority of monophasic stimulation of narrowly separated, longitudinal bipoles having rostral cathodes. Appl Neurophysiol. 1983;46(1-4):129-137.
-
(1983)
Appl Neurophysiol
, vol.46
, Issue.1-4
, pp. 129-137
-
-
Law, J.D.1
-
14
-
-
0028808074
-
Effects of electrode geometry and combination on nerve fibre selectivity in spinal cord stimulation
-
Holsheimer J, Struijk JJ, Tas NR. Effects of electrode geometry and combination on nerve fibre selectivity in spinal cord stimulation. Med Biol Eng Comput. 1995; 33(5):676-682.
-
(1995)
Med Biol Eng Comput
, vol.33
, Issue.5
, pp. 676-682
-
-
Holsheimer, J.1
Struijk, J.J.2
Tas, N.R.3
-
15
-
-
0030868743
-
Effect of anode-cathode configuration on paresthesia coverage in spinal cord stimulation
-
Holsheimer J, Wesselink WA. Effect of anode-cathode configuration on paresthesia coverage in spinal cord stimulation. Neurosurgery. 1997;41(3):654-659.
-
(1997)
Neurosurgery
, vol.41
, Issue.3
, pp. 654-659
-
-
Holsheimer, J.1
Wesselink, W.A.2
-
16
-
-
28744432244
-
Spinal cord stimulation for axial low back pain: A prospective, controlled trial comparing dual with single percutaneous electrodes
-
North RB, Kidd DH, Olin J, et al. Spinal cord stimulation for axial low back pain: a prospective, controlled trial comparing dual with single percutaneous electrodes. Spine (Phila Pa 1976). 2005;30(12):1412-1418.
-
(2005)
Spine (Phila Pa 1976)
, vol.30
, Issue.12
, pp. 1412-1418
-
-
North, R.B.1
Kidd, D.H.2
Olin, J.3
-
17
-
-
84555188246
-
Spinal cord stimulation: The clinical application of new technology
-
Hegarty D. Spinal cord stimulation: the clinical application of new technology. Anesthesiol Res Pract. 2012;2012:375691.
-
(2012)
Anesthesiol Res Pract
, vol.2012
, pp. 375691
-
-
Hegarty, D.1
-
18
-
-
0031933248
-
Clinical evaluation of paresthesia steering with a new system for spinal cord stimulation
-
Holsheimer J, Nuttin B, King GW, et al. Clinical evaluation of paresthesia steering with a new system for spinal cord stimulation. Neurosurgery. 1998;42(3):541-549.
-
(1998)
Neurosurgery
, vol.42
, Issue.3
, pp. 541-549
-
-
Holsheimer, J.1
Nuttin, B.2
King, G.W.3
-
19
-
-
0030198491
-
Transverse tripolar spinal cord stimulation: Theoretical performance of a dual channel system
-
Struijk JJ, Holsheimer J. Transverse tripolar spinal cord stimulation: theoretical performance of a dual channel system. Med Biol Eng Comput. 1996;34(4):273-279.
-
(1996)
Med Biol Eng Comput
, vol.34
, Issue.4
, pp. 273-279
-
-
Struijk, J.J.1
Holsheimer, J.2
-
20
-
-
0032901041
-
Quantitative aspects of the clinical performance of transverse tripolar spinal cord stimulation
-
Wesselink WA, Holsheimer J, King GW, Torgerson NA, Boom HB. Quantitative aspects of the clinical performance of transverse tripolar spinal cord stimulation. Neuromodulation. 1999;2(1):5-14.
-
(1999)
Neuromodulation
, vol.2
, Issue.1
, pp. 5-14
-
-
Wesselink, W.A.1
Holsheimer, J.2
King, G.W.3
Torgerson, N.A.4
Boom, H.B.5
-
21
-
-
79952680428
-
Electrode alignment of transverse tripoles using a percutaneous triple-lead approach in spinal cord stimulation
-
Sankarasubramanian V, Buitenweg JR, Holsheimer J, Veltink P. Electrode alignment of transverse tripoles using a percutaneous triple-lead approach in spinal cord stimulation. J Neural Eng. 2011;8(1):016010.
-
(2011)
J Neural Eng
, vol.8
, Issue.1
, pp. 016010
-
-
Sankarasubramanian, V.1
Buitenweg, J.R.2
Holsheimer, J.3
Veltink, P.4
-
22
-
-
0036705631
-
Spinal cord stimulation electrode design: Prospective, randomized, controlled trial comparing percutaneous and laminectomy electrodes-part I: Technical outcomes
-
North RB, Kidd DH,Olin JC, Sieracki JM. Spinal cord stimulation electrode design: prospective, randomized, controlled trial comparing percutaneous and laminectomy electrodes-part I: technical outcomes. Neurosurgery. 2002;51(2):381-389.
-
(2002)
Neurosurgery
, vol.51
, Issue.2
, pp. 381-389
-
-
North, R.B.1
Kidd Dholin, J.C.2
Sieracki, J.M.3
-
23
-
-
0003105428
-
Spinal cord stimulation with percutaneous and plate electrodes: Side effects and quantitative comparisons
-
North RB, Lanning A, Hessels R, Cutchis PN. Spinal cord stimulation with percutaneous and plate electrodes: side effects and quantitative comparisons. Neurosurg Focus. 1997;2(1):e3.
-
(1997)
Neurosurg Focus
, vol.2
, Issue.1
-
-
North, R.B.1
Lanning, A.2
Hessels, R.3
Cutchis, P.N.4
-
24
-
-
0031824259
-
Computer modelling of spinal cord stimulation and its contribution to therapeutic efficacy
-
Holsheimer J. Computer modelling of spinal cord stimulation and its contribution to therapeutic efficacy. Spinal Cord. 1998;36(8):531-540.
-
(1998)
Spinal Cord
, vol.36
, Issue.8
, pp. 531-540
-
-
Holsheimer, J.1
-
25
-
-
0026926765
-
Recruitment of dorsal column fibers in spinal cord stimulation: Influence of collateral branching
-
Struijk JJ, Holsheimer J, van der Heide G, Boom HBK. Recruitment of dorsal column fibers in spinal cord stimulation: influence of collateral branching. IEEE Trans Biomed Eng. 1992;39(9):903-912.
-
(1992)
IEEE Trans Biomed Eng
, vol.39
, Issue.9
, pp. 903-912
-
-
Struijk, J.J.1
Holsheimer, J.2
Van Der Heide, G.3
Hbk, B.4
-
26
-
-
0027741398
-
Excitation of dorsal root fibers in spinal cord stimulation: A theoretical study
-
Struijk JJ, Holsheimer J, Boom HBK. Excitation of dorsal root fibers in spinal cord stimulation: a theoretical study. IEEE Trans Biomed Eng. 1993;40(7):632-639.
-
(1993)
IEEE Trans Biomed Eng
, vol.40
, Issue.7
, pp. 632-639
-
-
Struijk, J.J.1
Holsheimer, J.2
Hbk, B.3
-
27
-
-
0003047992
-
Stimulation usage range for chronic pain management
-
He J, Barolat G, Ketcik B. Stimulation usage range for chronic pain management. Analgesia. 1994;1(1):75-80.
-
(1994)
Analgesia
, vol.1
, Issue.1
, pp. 75-80
-
-
He, J.1
Barolat, G.2
Ketcik, B.3
-
28
-
-
84874365729
-
Variability of contact impedance by vertebral placement in spinal cord stimulation [abstract]
-
Paper presented at October 16-2 San Francisco, CA. Abstract
-
Alo K, Varga C, Krames E, Prager J, Bradley K. Variability of contact impedance by vertebral placement in spinal cord stimulation [abstract]. Paper presented at: the 54th Congress of Neurological Surgeons; October 16-2, 2005; San Francisco, CA. Abstract.
-
(2005)
The 54th Congress of Neurological Surgeons
-
-
Alo, K.1
Varga, C.2
Krames, E.3
Prager, J.4
Bradley, K.5
-
29
-
-
0017103492
-
Analysis of a model for excitation of myelinated nerve
-
McNeal DR. Analysis of a model for excitation of myelinated nerve. IEEE Trans Biomed Eng. 1976;23(4):329-337.
-
(1976)
IEEE Trans Biomed Eng
, vol.23
, Issue.4
, pp. 329-337
-
-
McNeal, D.R.1
-
31
-
-
0033981759
-
Laminectomy versus percutaneous electrode placement for spinal cord stimulation
-
Villavicencio AT, Leveque JC, Rubin L, Bulsara K, Gorecki JP. Laminectomy versus percutaneous electrode placement for spinal cord stimulation. Neurosurgery. 2000;46(2):399-405.
-
(2000)
Neurosurgery
, vol.46
, Issue.2
, pp. 399-405
-
-
Villavicencio, A.T.1
Leveque, J.C.2
Rubin, L.3
Bulsara, K.4
Gorecki, J.P.5
-
32
-
-
85027949390
-
Back pain: A real target for spinal cord stimulation?
-
Rigoard P, Delmotte A, D'Houtaud S, et al. Back pain: a real target for spinal cord stimulation? Neurosurgery. 2012;70(3):574-584.
-
(2012)
Neurosurgery
, vol.70
, Issue.3
, pp. 574-584
-
-
Rigoard, P.1
Delmotte, A.2
D'Houtaud, S.3
-
33
-
-
84874344582
-
Three column contact patterns for Spinal cord stimulation offer selective dorsal column fiber activation
-
Wesselink WM, North RB. Three column contact patterns for Spinal cord stimulation offer selective dorsal column fiber activation. Neurosurgery. 2006;59 (2):470-471.
-
(2006)
Neurosurgery
, vol.59
, Issue.2
, pp. 470-471
-
-
Wesselink, W.M.1