메뉴 건너뛰기




Volumn 8, Issue 2, 2005, Pages 88-99

Technical performance of percutaneous leads for spinal cord stimulation: A modeling study

Author keywords

Dual lead; Energy consumption; Paresthesia coverage; Percutaneous lead; Spinal cord stimulation

Indexed keywords

ARTICLE; COMPUTER MODEL; COMPUTER PROGRAM; DORSAL ROOT; DURA MATER; ELECTRODE; ENERGY CONSUMPTION; NERVE FIBER; PAIN; SPINAL CORD; SPINAL CORD STIMULATION; SPINE;

EID: 18544369146     PISSN: 10947159     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1525-1403.2005.00224.x     Document Type: Article
Times cited : (33)

References (24)
  • 2
    • 0036556298 scopus 로고    scopus 로고
    • New trends in neuromodulation for the management of neuropathic pain
    • Alo KM, Holsheimer J. New trends in neuromodulation for the management of neuropathic pain. Neurosurgery 2002;50:690-704.
    • (2002) Neurosurgery , vol.50 , pp. 690-704
    • Alo, K.M.1    Holsheimer, J.2
  • 3
    • 0030978901 scopus 로고    scopus 로고
    • Effectiveness of spinal cord stimulation in the management of chronic pain. Analysis of technical drawbacks and solutions
    • Holsheimer J. Effectiveness of spinal cord stimulation in the management of chronic pain. Analysis of technical drawbacks and solutions. Neurosurgery 1997;40:990-996.
    • (1997) Neurosurgery , vol.40 , pp. 990-996
    • Holsheimer, J.1
  • 4
    • 0022270345 scopus 로고
    • A theoretical study of epidural electrical stimulation of the spinal cord-Part II. Effects on long myelinated fibers
    • Coburn B. A theoretical study of epidural electrical stimulation of the spinal cord-Part II. Effects on long myelinated fibers. IEEE Trans Biomed Eng 1985;32:978-986.
    • (1985) IEEE Trans Biomed Eng , vol.32 , pp. 978-986
    • Coburn, B.1
  • 5
    • 0027741398 scopus 로고
    • Excitation of dorsal root fibers in spinal cord stimulation: A theoretical study
    • Struijk JJ, Holsheimer J, Boom HBK. Excitation of dorsal root fibers in spinal cord stimulation: a theoretical study. IEEE Trans Biomed Eng 1993;40:632-639.
    • (1993) IEEE Trans Biomed Eng , vol.40 , pp. 632-639
    • Struijk, J.J.1    Holsheimer, J.2    Boom, H.B.K.3
  • 6
    • 0028808074 scopus 로고
    • Effects of electrode geometry and combination on nerve fiber selectivity in spinal cord stimulation
    • Holsheimer J, Struijk JJ, Tas NR. Effects of electrode geometry and combination on nerve fiber selectivity in spinal cord stimulation. Med Biol Eng Comput 1995;33:676-682.
    • (1995) Med Biol Eng Comput , vol.33 , pp. 676-682
    • Holsheimer, J.1    Struijk, J.J.2    Tas, N.R.3
  • 7
    • 0031236507 scopus 로고    scopus 로고
    • Optimum electrode geometry for spinal cord stimulation: The narrow bipole and tripole
    • Holsheimer J, Wesselink WA. Optimum electrode geometry for spinal cord stimulation: the narrow bipole and tripole. Med Biol Eng Comput 1997;35:493-497.
    • (1997) Med Biol Eng Comput , vol.35 , pp. 493-497
    • Holsheimer, J.1    Wesselink, W.A.2
  • 8
    • 0026331110 scopus 로고
    • How do geometric factors influence epidural spinal cord stimulation? a quantitative analysis of computer modeling
    • Holsheimer J, Struijk JJ. How do geometric factors influence epidural spinal cord stimulation? A quantitative analysis of computer modeling. Stereotact Funct Neurosurg 1991;56:234-239.
    • (1991) Stereotact Funct Neurosurg , vol.56 , pp. 234-239
    • Holsheimer, J.1    Struijk, J.J.2
  • 9
    • 0026926765 scopus 로고
    • Recruitment of dorsal column fibers in spinal cord stimulation: Influence of collateral branching
    • Struijk JJ, Holsheimer J, van der Heide GG, Boom HBK. Recruitment of dorsal column fibers in spinal cord stimulation: influence of collateral branching. IEEE Trans Biomed Eng 1992;39:903-912.
    • (1992) IEEE Trans Biomed Eng , vol.39 , pp. 903-912
    • Struijk, J.J.1    Holsheimer, J.2    Van Der Heide, G.G.3    Boom, H.B.K.4
  • 10
    • 0027612103 scopus 로고
    • Paresthesia thresholds in spinal cord stimulation: A comparison of theoretical results with clinical data
    • Struijk JJ, Holsheimer J, Barolat G, He J, Boom HBK. Paresthesia thresholds in spinal cord stimulation: a comparison of theoretical results with clinical data. IEEE Trans Rehabil Eng 1993;1:101-108.
    • (1993) IEEE Trans Rehabil Eng , vol.1 , pp. 101-108
    • Struijk, J.J.1    Holsheimer, J.2    Barolat, G.3    He, J.4    Boom, H.B.K.5
  • 13
    • 0017103492 scopus 로고
    • Analysis of a model for excitation of myelinated nerve
    • McNeal DR. Analysis of a model for excitation of myelinated nerve. IEEE Trans Biomed Eng 1976;23:329-337.
    • (1976) IEEE Trans Biomed Eng , vol.23 , pp. 329-337
    • McNeal, D.R.1
  • 14
    • 0033058688 scopus 로고    scopus 로고
    • A model of the electrical behaviour of myelinated sensory nerve fibers based on human data
    • Wesselink WA, Holsheimer J, Boom HBK. A model of the electrical behaviour of myelinated sensory nerve fibers based on human data. Med Biol Eng Comput 1999;37:228-235.
    • (1999) Med Biol Eng Comput , vol.37 , pp. 228-235
    • Wesselink, W.A.1    Holsheimer, J.2    Boom, H.B.K.3
  • 15
    • 0000318397 scopus 로고    scopus 로고
    • Spinal geometry and paresthesia coverage in spinal cord stimulation
    • Holsheimer J, Barolat G. Spinal geometry and paresthesia coverage in spinal cord stimulation. Neuromodulation 1998;1:129-136.
    • (1998) Neuromodulation , vol.1 , pp. 129-136
    • Holsheimer, J.1    Barolat, G.2
  • 17
    • 0036705631 scopus 로고    scopus 로고
    • Spinal cord stimulation electrode design: Prospective, randomized, controlled trial comparing percutaneous and laminectomy electrodes-Part I: Technical outcomes
    • North RB, Kidd DH, Olin JC, Sieracki JM. Spinal cord stimulation electrode design: prospective, randomized, controlled trial comparing percutaneous and laminectomy electrodes-Part I: technical outcomes. Neurosurgery 2002;51:381-390.
    • (2002) Neurosurgery , vol.51 , pp. 381-390
    • North, R.B.1    Kidd, D.H.2    Olin, J.C.3    Sieracki, J.M.4
  • 18
    • 0003047992 scopus 로고
    • Stimulation usage range for chronic pain management
    • He J, Barolat G, Ketcik B. Stimulation usage range for chronic pain management. Analgesia 1995;1:75-80.
    • (1995) Analgesia , vol.1 , pp. 75-80
    • He, J.1    Barolat, G.2    Ketcik, B.3
  • 19
    • 8544277297 scopus 로고    scopus 로고
    • Technical performance of percutaneous and laminectomy leads analyzed by modeling
    • Manola LJ, Holsheimer J. Technical performance of percutaneous and laminectomy leads analyzed by modeling. Neuromodulation 2004;7:231-241.
    • (2004) Neuromodulation , vol.7 , pp. 231-241
    • Manola, L.J.1    Holsheimer, J.2
  • 20
    • 0027446231 scopus 로고
    • Mapping of sensory responses to epidural stimulation of the intraspinal neural structures in man
    • Barolat G, Massaro F, He J, Zeme S, Ketcik B. Mapping of sensory responses to epidural stimulation of the intraspinal neural structures in man. J Neurosurg 1993;78:233-239.
    • (1993) J Neurosurg , vol.78 , pp. 233-239
    • Barolat, G.1    Massaro, F.2    He, J.3    Zeme, S.4    Ketcik, B.5
  • 21
    • 0003105428 scopus 로고    scopus 로고
    • Spinal cord stimulation with percutaneous and plate electrodes, side effects and quantitative comparisons
    • North RB, Lanning A, Hessels R, Cutchis PN. Spinal cord stimulation with percutaneous and plate electrodes, side effects and quantitative comparisons. Neurosurg Focus 1997;2:1-5.
    • (1997) Neurosurg Focus , vol.2 , pp. 1-5
    • North, R.B.1    Lanning, A.2    Hessels, R.3    Cutchis, P.N.4
  • 22
    • 0036098142 scopus 로고    scopus 로고
    • Four year follow-up of dual electrode spinal cord stimulation for chronic pain
    • Alo KM, Redko V, Chornov J. Four year follow-up of dual electrode spinal cord stimulation for chronic pain. Neuromodulation 2002;5:79-88.
    • (2002) Neuromodulation , vol.5 , pp. 79-88
    • Alo, K.M.1    Redko, V.2    Chornov, J.3
  • 23
    • 0026721081 scopus 로고
    • Patient-interactive computer-controlled neurological stimulation system: Clinical efficacy in spinal cord stimulator adjustment
    • North RB, Fowler K, Nigrin DJ, Szymanski R. Patient-interactive computer-controlled neurological stimulation system: clinical efficacy in spinal cord stimulator adjustment. J Neurosurg 1992;76:967-972.
    • (1992) J Neurosurg , vol.76 , pp. 967-972
    • North, R.B.1    Fowler, K.2    Nigrin, D.J.3    Szymanski, R.4
  • 24
    • 0030868743 scopus 로고    scopus 로고
    • Effect of anode-cathode configuration on paresthesia coverage in spinal cord stimulation
    • Holsheimer J, Wesselink WA. Effect of anode-cathode configuration on paresthesia coverage in spinal cord stimulation. Neurosurgery 1997;41:654-660.
    • (1997) Neurosurgery , vol.41 , pp. 654-660
    • Holsheimer, J.1    Wesselink, W.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.