Shock or no shock-a question of philosophy or should intraoperative implantable cardioverter defibrillator testing be recommended?

Author keywords

Implantable cardioverter defibrillator; Intraoperative test

Indexed keywords

AMIODARONE;

EID: 84874310792     PISSN: 15699293     EISSN: 15699285     Source Type: Journal    
DOI: 10.1093/icvts/ivs479     Document Type: Article
Times cited : (6)

References (24)
  • 1
    • 0018975668 scopus 로고
    • Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings
    • Mirowski M, Reid PR, Mower MM, Watkins L, Gott VL, Schauble JF et al. Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. N Engl J Med 1980; 303:322-4.
    • (1980) N Engl J Med , vol.303 , pp. 322-324
    • Mirowski, M.1    Reid, P.R.2    Mower, M.M.3    Watkins, L.4    Gott, V.L.5    Schauble, J.F.6
  • 2
    • 53249090182 scopus 로고    scopus 로고
    • ESC guidelines for the diagnosis and treatment of acute and chronic heart failure 2008 the task force for the diagnosis and treatment of acute and chronic heart failure 2008 of the european society of cardiology developed in collaboration with the heart failure association of the ESC (HFA) and endorsed by the european society of intensive Care Medicine (ESICM)
    • Dickstein K, Cohen-Solal A, Filippatos G, McMurray JJ, Ponikowski P, Poole-Wilson PA et al. ESC guidelines for the diagnosis and treatment of acute and chronic heart failure 2008: The Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2008 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association of the ESC (HFA) and endorsed by the European Society of Intensive Care Medicine (ESICM). Eur Heart J 2008;29:2388-442.
    • (2008) Eur Heart J , vol.29 , pp. 2388-2442
    • Dickstein, K.1    Cohen-Solal, A.2    Filippatos, G.3    McMurray, J.J.4    Ponikowski, P.5    Poole-Wilson, P.A.6
  • 3
    • 3242794231 scopus 로고    scopus 로고
    • Is defibrillation testing required for defibrillator implantation?
    • Strickberger SA, Klein GJ. Is defibrillation testing required for defibrillator implantation? J Am Coll Cardiol 2004;44:88-91.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 88-91
    • Strickberger, S.A.1    Klein, G.J.2
  • 4
    • 17144413764 scopus 로고    scopus 로고
    • Should shocks still be administered during impantable cardioverter-defibrillator insertion?
    • Ideker RE, Epstein AE, Plump VJ. Should shocks still be administered during impantable cardioverter-defibrillator insertion? Heart Rhythm 2005;2:462-3.
    • (2005) Heart Rhythm , vol.2 , pp. 462-463
    • Ideker, R.E.1    Epstein, A.E.2    Plump, V.J.3
  • 5
    • 48449094224 scopus 로고    scopus 로고
    • SCD-HeFT Investigators. No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial)
    • Blatt JA, Poole JE, Johnson GW, Callans DJ, Raitt MH, Reddy RK et al.; SCD-HeFT Investigators. No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial). J Am Coll Cardiol 2008;52:551-6.
    • (2008) J Am Coll Cardiol , vol.52 , pp. 551-556
    • Blatt, J.A.1    Poole, J.E.2    Johnson, G.W.3    Callans, D.J.4    Raitt, M.H.5    Reddy, R.K.6
  • 6
    • 71849086249 scopus 로고    scopus 로고
    • Intraoperative defibrillation threshold testing during implantable cardioverter-defibrillator insertion: Do we really need it?
    • Calvi V, Dugo D, Capodanno D, Arancio R, Di Grazia A, Liotta C et al. Intraoperative defibrillation threshold testing during implantable cardioverter-defibrillator insertion: do we really need it? Am Heart J 2010;159:98-102.
    • (2010) Am Heart J , vol.159 , pp. 98-102
    • Calvi, V.1    Dugo, D.2    Capodanno, D.3    Arancio, R.4    Di Grazia, A.5    Liotta, C.6
  • 7
    • 34248162434 scopus 로고    scopus 로고
    • Inductionless or limited shock testing is possible in most patients with implantable cardioverter-defibrillators/cardiac resynchronization therapy defibrillators: Results of the multicenter ASSURE Study (arrhythmia single shock defibrillation threshold testing versus upper limit of vulnerability: Risk reduction evaluation with implantable cardioverterdefibrillator implantations
    • Day JD, Doshi RN, Belott P, Birgersdotter-Green U, Behboodikhah M, Ott P et al. Inductionless or limited shock testing is possible in most patients with implantable cardioverter-defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (arrhythmia single shock defibrillation threshold testing versus upper limit of vulnerability: Risk reduction evaluation with implantable cardioverterdefibrillator implantations). Circulation 2007;115:2382-9.
    • (2007) Circulation , vol.115 , pp. 2382-2389
    • Day, J.D.1    Doshi, R.N.2    Belott, P.3    Birgersdotter-Green, U.4    Behboodikhah, M.5    Ott, P.6
  • 8
    • 13544250737 scopus 로고    scopus 로고
    • One conversion of ventricular fibrillation is adequate for implantable cardioverter-defibrillator implant: An analysis from the Low Energy Safety Study (LESS
    • Higgins S, Mann D, Calkins H, Estes NA, Strickberger SA, Breiter D et al. One conversion of ventricular fibrillation is adequate for implantable cardioverter-defibrillator implant: an analysis from the Low Energy Safety Study (LESS). Heart Rhythm 2005;2:117-22.
    • (2005) Heart Rhythm , vol.2 , pp. 117-122
    • Higgins, S.1    Mann, D.2    Calkins, H.3    Estes, N.A.4    Strickberger, S.A.5    Breiter, D.6
  • 9
    • 33644693959 scopus 로고    scopus 로고
    • Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients
    • Alter P, Waldhans S, Plachta E, Moosdorf R, Grimm W. Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients. Pacing Clin Electrophysiol 2005;28:926-32.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 926-932
    • Alter, P.1    Waldhans, S.2    Plachta, E.3    Moosdorf, R.4    Grimm, W.5
  • 10
    • 34548646141 scopus 로고    scopus 로고
    • Indications for premissal testing with arrhythmia-induction in patients receiving an implantable cardioverter defibrillator
    • Christ C, Becker R, Voss F, Kelemen K, Senges-Becker J, Hauck M et al. Indications for premissal testing with arrhythmia-induction in patients receiving an implantable cardioverter defibrillator. Clin Res Cardiol 2007;96:613-20.
    • (2007) Clin Res Cardiol , vol.96 , pp. 613-620
    • Christ, C.1    Becker, R.2    Voss, F.3    Kelemen, K.4    Senges-Becker, J.5    Hauck, M.6
  • 13
    • 0036479467 scopus 로고    scopus 로고
    • The Low Energy Safety Study (LESS): Rationale, design, patient characteristics, and device utilization
    • Mann DE, Klein RC, Higgins SL, Freedmann RA, Hahn SJ, Huang ZZ. The Low Energy Safety Study (LESS): rationale, design, patient characteristics, and device utilization. Am Heart J 2002;143:199-204.
    • (2002) Am Heart J , vol.143 , pp. 199-204
    • Mann, D.E.1    Klein, R.C.2    Higgins, S.L.3    Freedmann, R.A.4    Hahn, S.J.5    Huang, Z.Z.6
  • 14
    • 39649085555 scopus 로고    scopus 로고
    • The top 10 reasons to avoid defibrillation threshold testing during ICD implantation
    • Viskin S, Rosse R. The top 10 reasons to avoid defibrillation threshold testing during ICD implantation. Heart Rhythm 2008;5:391-3.
    • (2008) Heart Rhythm , vol.5 , pp. 391-393
    • Viskin, S.1    Rosse, R.2
  • 15
    • 0034545462 scopus 로고    scopus 로고
    • Is all ventricular fibrillation the same? Influence of mode of induction on characteristics of ventricular fibrillation
    • Taneja T, Goldberger J, Johnson D, Kadish A. Is all ventricular fibrillation the same? Influence of mode of induction on characteristics of ventricular fibrillation. J Cardiovasc Electrophysiol 2000;11:1355-63.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 1355-1363
    • Taneja, T.1    Goldberger, J.2    Johnson, D.3    Kadish, A.4
  • 16
    • 39649116512 scopus 로고    scopus 로고
    • Differences in the characteristics of induced and spontaneous episodes of ventricular fibrillation
    • Lever NA, Newall EG, Larsen PD. Differences in the characteristics of induced and spontaneous episodes of ventricular fibrillation. Europace 2007;9:1054-8.
    • (2007) Europace , vol.9 , pp. 1054-1058
    • Lever, N.A.1    Newall, E.G.2    Larsen, P.D.3
  • 17
    • 0036264043 scopus 로고    scopus 로고
    • Differences in the activation patterns between sustained and self-terminating episodes of human ventricular fibrillation
    • Mäkikallio TH, Huikuri HV, Myerburg RJ, Seppänen T, Kloosterman M, Interian A Jr et al. Differences in the activation patterns between sustained and self-terminating episodes of human ventricular fibrillation. Ann Med 2002;34:130-5.
    • (2002) Ann Med , vol.34 , pp. 130-135
    • Mäkikallio, T.H.1    Huikuri, H.V.2    Myerburg, R.J.3    Seppänen, T.4    Kloosterman, M.5    Interian Jr. A6
  • 18
    • 33645326870 scopus 로고    scopus 로고
    • The effect of induction method on defibrillation threshold and ventricular fibrillation cycle length
    • Zima E, Gergerly M, Soós P, Gellér LA, Nemes A, Acsády G et al. The effect of induction method on defibrillation threshold and ventricular fibrillation cycle length. J Cardiovasc Electrophysiol 2006;17:377-81.
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 377-381
    • Zima, E.1    Gergerly, M.2    Soós, P.3    Gellér, L.A.4    Nemes, A.5    Acsády, G.6
  • 19
    • 78149248034 scopus 로고    scopus 로고
    • Right ventricular stimulation threshold at ICD implant predicts device therapy in primary prevention patients with ischaemic heart disease
    • Atary JZ, Borleffs CJ, van der Bom JG, Trines SA, Bootsma M, Zeppenfeld K et al. Right ventricular stimulation threshold at ICD implant predicts device therapy in primary prevention patients with ischaemic heart disease. Europace 2010;12:1581-8.
    • (2010) Europace , vol.12 , pp. 1581-1588
    • Atary, J.Z.1    Borleffs, C.J.2    Van Der Bom, J.G.3    Trines, S.A.4    Bootsma, M.5    Zeppenfeld, K.6
  • 20
    • 39649088013 scopus 로고    scopus 로고
    • Complications associated with defibrillation threshold testing: The Canadian experience
    • Birnie D, Tung S, Simpson C, Crystal E, Exner D, Ayala Paredes FA et al. Complications associated with defibrillation threshold testing: the Canadian experience. Heart Rhythm 2008;5:391-3.
    • (2008) Heart Rhythm , vol.5 , pp. 391-393
    • Birnie, D.1    Tung, S.2    Simpson, C.3    Crystal, E.4    Exner, D.5    Ayala Paredes, F.A.6
  • 22
    • 77957984258 scopus 로고    scopus 로고
    • Long-term benefit of primary prevention with an implantable cardioverterdefibrillator: An extended 8-year follow-up study of the multicenter automatic defibrillator implantation trial II
    • Goldberg I, Gillespie J, Moss AJ, Hall WJ, Klein H, McNitt S et al. Long-term benefit of primary prevention with an implantable cardioverterdefibrillator: an extended 8-year follow-up study of the multicenter automatic defibrillator implantation trial II. Circulation 2010;122:1265-71.
    • (2010) Circulation , vol.122 , pp. 1265-1271
    • Goldberg, I.1    Gillespie, J.2    Moss, A.J.3    Hall, W.J.4    Klein, H.5    McNitt, S.6
  • 23
    • 84867160141 scopus 로고    scopus 로고
    • Use of primary prevention implantable cardioverter-defibrillators in a population-based cohort is associated with significant survival benefit
    • Parkash R, Sapp JL, Basa M, Doucette S, Thompson K, Gardner M et al. Use of primary prevention implantable cardioverter-defibrillators in a population-based cohort is associated with significant survival benefit. Circ Arrhythm Electrophysiol 2012;5:706-13.
    • (2012) Circ Arrhythm Electrophysiol , vol.5 , pp. 706-713
    • Parkash, R.1    Sapp, J.L.2    Basa, M.3    Doucette, S.4    Thompson, K.5    Gardner, M.6
  • 24
    • 84874332606 scopus 로고    scopus 로고
    • ICD-test: Is the evaluation of the defibrillation threshold (DFT) still up to date? the ATLANTIS Register
    • Napp A, Birkenhauer F, Lee KM, Gemein C, Zink M, Knackstedt C et al. ICD-test: is the evaluation of the defibrillation threshold (DFT) still up to date? The ATLANTIS Register. Eur Heart J 2010;31:928-9.
    • (2010) Eur Heart J , vol.31 , pp. 928-929
    • Napp, A.1    Birkenhauer, F.2    Lee, K.M.3    Gemein, C.4    Zink, M.5    Knackstedt, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.