메뉴 건너뛰기




Volumn 26, Issue 3, 2011, Pages 177-185

Current status of optical coherence tomography

Author keywords

Coronary artery disease; Imaging; Neointima; Optical coherence tomography; Stent

Indexed keywords

ARTICLE; ARTIFACT; CORONARY ARTERY; CORONARY ARTERY ATHEROSCLEROSIS; CORONARY STENT; HEALING; HUMAN; IMAGING SYSTEM; NEOINTIMA; OPTICAL COHERENCE TOMOGRAPHY; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS;

EID: 84874202053     PISSN: 18684300     EISSN: 18684297     Source Type: Journal    
DOI: 10.1007/s12928-011-0057-0     Document Type: Article
Times cited : (1)

References (42)
  • 1
    • 41949094809 scopus 로고    scopus 로고
    • Safety and feasibility of a new non-occlusive technique for facilitated intracoronary optical coherence tomography (OCT) acquisition in various clinical and anatomical scenarios
    • Prati F, Cera F, Ramazzoti V, Imola F, Guidice R, Albertucci M. Safety and feasibility of a new non-occlusive technique for facilitated intracoronary optical coherence tomography (OCT) acquisition in various clinical and anatomical scenarios. Eurointervention. 2007; 3: 365-70.
    • (2007) Eurointervention. , vol.3 , pp. 365-370
    • Prati, F.1    Cera, F.2    Ramazzoti, V.3    Imola, F.4    Guidice, R.5    Albertucci, M.6
  • 2
    • 50449104976 scopus 로고    scopus 로고
    • Safety and usefulness of non-occlusive image acquisition technique for optical coherence tomography
    • Kataiwa H, Tanaka A, Kitabata H, Imanishi T, Akasaka T. Safety and usefulness of non-occlusive image acquisition technique for optical coherence tomography. Circ J. 2008; 72: 1536-7.
    • (2008) Circ J. , vol.72 , pp. 1536-1537
    • Kataiwa, H.1    Tanaka, A.2    Kitabata, H.3    Imanishi, T.4    Akasaka, T.5
  • 4
    • 77956632931 scopus 로고    scopus 로고
    • Head to head comparison between the conventional balloon occlusion method and the non-occlusion method for optical coherence tomography
    • (epub ahead of print)
    • Kataiwa H, Tanaka A, Kitabata H, Matsumoto H, Kashiwagi M, Kuroi A, et al. Head to head comparison between the conventional balloon occlusion method and the non-occlusion method for optical coherence tomography. Int J Cardiol. 2009; 5 (epub ahead of print).
    • (2009) Int J Cardiol. , pp. 5
    • Kataiwa, H.1    Tanaka, A.2    Kitabata, H.3    Matsumoto, H.4    Kashiwagi, M.5    Kuroi, A.6
  • 5
    • 78751664403 scopus 로고    scopus 로고
    • Optical coherence tomography imaging: current status and future perspectives
    • Kubo T, Asakura T. Optical coherence tomography imaging: current status and future perspectives. Cardiovasc Interv Ther. 2010; 25: 2-10.
    • (2010) Cardiovasc Interv Ther. , vol.25 , pp. 2-10
    • Kubo, T.1    Asakura, T.2
  • 6
    • 76049118483 scopus 로고    scopus 로고
    • Advantage of next-generation frequency-domain optical coherence tomography compared with conventional time-domain system in the assessment of coronary lesion
    • Takarada S, Imanishi T, Liu Y, Ikejima H, Tsujioka H, Kuroi A, et al. Advantage of next-generation frequency-domain optical coherence tomography compared with conventional time-domain system in the assessment of coronary lesion. Catheter Cardiovasc Interv. 2010; 75: 202-6.
    • (2010) Catheter Cardiovasc Interv. , vol.75 , pp. 202-206
    • Takarada, S.1    Imanishi, T.2    Liu, Y.3    Ikejima, H.4    Tsujioka, H.5    Kuroi, A.6
  • 10
    • 0037422532 scopus 로고    scopus 로고
    • Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography
    • Tearney GJ, Yabushita H, Houser SL, Aretz HT, Jang IK, Schlendorf KH, et al. Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography. Circulation. 2003; 107: 113-9.
    • (2003) Circulation. , vol.107 , pp. 113-119
    • Tearney, G.J.1    Yabushita, H.2    Houser, S.L.3    Aretz, H.T.4    Jang, I.K.5    Schlendorf, K.H.6
  • 12
    • 77954789924 scopus 로고    scopus 로고
    • Coronary optical frequency domain imaging (OFDI) for in vivo evaluation of stent healing: comparison with light and electron microscopy
    • Templin C, Meyer M, Müller MF, Djonov V, Hlushchuk R, Dimova I, et al. Coronary optical frequency domain imaging (OFDI) for in vivo evaluation of stent healing: comparison with light and electron microscopy. Eur Heart J. 2010; 31: 1792-801.
    • (2010) Eur Heart J , vol.31 , pp. 1792-1801
    • Templin, C.1    Meyer, M.2    Müller, M.F.3    Djonov, V.4    Hlushchuk, R.5    Dimova, I.6
  • 13
    • 77953484204 scopus 로고    scopus 로고
    • Intriguing peri-strut low-intensity area detected by optical coherence tomography after coronary stent deployment
    • Teramoto T, Ikeno F, Otake H, Lyons JK, van Beusekom HM, Fearon WF, et al. Intriguing peri-strut low-intensity area detected by optical coherence tomography after coronary stent deployment. Circ J. 2010; 74: 1257-9.
    • (2010) Circ J. , vol.74 , pp. 1257-1259
    • Teramoto, T.1    Ikeno, F.2    Otake, H.3    Lyons, J.K.4    van Beusekom, H.M.5    Fearon, W.F.6
  • 14
    • 72549090920 scopus 로고    scopus 로고
    • Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography
    • Takano M, Yamamoto M, Inami S, Murakami D, Ohba T, Seino Y, et al. Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography. J Am Coll Cardiol. 2009; 55: 26-32.
    • (2009) J Am Coll Cardiol , vol.55 , pp. 26-32
    • Takano, M.1    Yamamoto, M.2    Inami, S.3    Murakami, D.4    Ohba, T.5    Seino, Y.6
  • 15
    • 51749118724 scopus 로고    scopus 로고
    • Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare metal stent 3 months after implantation
    • Xie Y, Takano M, Murakami D, Yamamoto M, Okamatsu K, Inami S, et al. Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare metal stent 3 months after implantation. Am J Cardiol. 2008; 102: 27-31.
    • (2008) Am J Cardiol , vol.102 , pp. 27-31
    • Xie, Y.1    Takano, M.2    Murakami, D.3    Yamamoto, M.4    Okamatsu, K.5    Inami, S.6
  • 16
    • 39549105785 scopus 로고    scopus 로고
    • Long-term follow up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: do uncovered struts persist?
    • Takano M, Yamamoto M, Inami S, Murakami D, Seimiya K, Ohba T, et al. Long-term follow up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: do uncovered struts persist? J Am Coll Cardiol. 2008; 51: 968-9.
    • (2008) J Am Coll Cardiol , vol.51 , pp. 968-969
    • Takano, M.1    Yamamoto, M.2    Inami, S.3    Murakami, D.4    Seimiya, K.5    Ohba, T.6
  • 17
    • 73349096901 scopus 로고    scopus 로고
    • Long-term follow-up of neointimal coverage of sirolimus-eluting stents-evaluation with optical coherence tomography
    • Ishigami K, Uemura S, Morikawa Y, Soeda T, Okayama S, Nishida T, et al. Long-term follow-up of neointimal coverage of sirolimus-eluting stents-evaluation with optical coherence tomography. Circ J. 2009; 73: 2300-7.
    • (2009) Circ J. , vol.73 , pp. 2300-2307
    • Ishigami, K.1    Uemura, S.2    Morikawa, Y.3    Soeda, T.4    Okayama, S.5    Nishida, T.6
  • 18
    • 77951723057 scopus 로고    scopus 로고
    • Comparison by optical coherence tomography of paclitaxel-eluting stents with sirolimus-eluting stents implanted in one coronary artery in one procedure. 6 month follow-up
    • Miyoshi N, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, et al. Comparison by optical coherence tomography of paclitaxel-eluting stents with sirolimus-eluting stents implanted in one coronary artery in one procedure. 6 month follow-up. Circ J. 2010; 74: 903-8.
    • (2010) Circ J. , vol.74 , pp. 903-908
    • Miyoshi, N.1    Shite, J.2    Shinke, T.3    Otake, H.4    Tanino, Y.5    Ogasawara, D.6
  • 19
    • 69549110861 scopus 로고    scopus 로고
    • Advanced neointimal growth is not associated with a low risk of in-stent thrombus. Optical coherence tomographic findings after first-generation drug-eluting stent implantation
    • Murakami D, Takano M, Yamamoto M, Inami S, Ohba T, Seino Y, et al. Advanced neointimal growth is not associated with a low risk of in-stent thrombus. Optical coherence tomographic findings after first-generation drug-eluting stent implantation. Circ J. 2009; 73: 1627-34.
    • (2009) Circ J. , vol.73 , pp. 1627-1634
    • Murakami, D.1    Takano, M.2    Yamamoto, M.3    Inami, S.4    Ohba, T.5    Seino, Y.6
  • 20
    • 72149133094 scopus 로고    scopus 로고
    • Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial
    • Kim JS, Jang IK, Fan C, Kim TH, Kim JS, Park SM, et al. Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial. JACC Cardiovasc Interv. 2009; 2: 1240-7.
    • (2009) JACC Cardiovasc Interv. , vol.2 , pp. 1240-1247
    • Kim, J.S.1    Jang, I.K.2    Fan, C.3    Kim, T.H.4    Kim, J.S.5    Park, S.M.6
  • 22
    • 77954746572 scopus 로고    scopus 로고
    • ODESSA Trial Investigators. Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents
    • Guagliumi G, Musumeci G, Sirbu V, Bezerra HG, Suzuki N, Fiocca L, et al. ODESSA Trial Investigators. Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents. JACC Cardiovasc Interv. 2010; 3: 531-9.
    • (2010) JACC Cardiovasc Interv. , vol.3 , pp. 531-539
    • Guagliumi, G.1    Musumeci, G.2    Sirbu, V.3    Bezerra, H.G.4    Suzuki, N.5    Fiocca, L.6
  • 23
    • 34147135208 scopus 로고    scopus 로고
    • Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent 3 months after implantation
    • Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, et al. Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent 3 months after implantation. Am J Cardiol. 2007; 99: 1033-8.
    • (2007) Am J Cardiol , vol.99 , pp. 1033-1038
    • Takano, M.1    Inami, S.2    Jang, I.K.3    Yamamoto, M.4    Murakami, D.5    Seimiya, K.6
  • 24
    • 47349102744 scopus 로고    scopus 로고
    • Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study
    • Kubo T, Imanishi T, Kitabata H, Kuroi A, Ueno S, Yamano T, et al. Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study. JACC Cardiovasc Imaging. 2008; 1: 475-84.
    • (2008) JACC Cardiovasc Imaging. , vol.1 , pp. 475-484
    • Kubo, T.1    Imanishi, T.2    Kitabata, H.3    Kuroi, A.4    Ueno, S.5    Yamano, T.6
  • 25
    • 65549170720 scopus 로고    scopus 로고
    • Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable/unstable angina: insights from optical coherence tomography
    • Gonzalo N, Barlis P, Serruys PW, Garcia-Garcia HM, Onuma Y, Ligthart J, et al. Incomplete stent apposition and delayed tissue coverage are more frequent in drug-eluting stents implanted during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction than in drug-eluting stents implanted for stable/unstable angina: insights from optical coherence tomography. JACC Cardiovasc Interv. 2009; 2: 445-52.
    • (2009) JACC Cardiovasc Interv. , vol.2 , pp. 445-452
    • Gonzalo, N.1    Barlis, P.2    Serruys, P.W.3    Garcia-Garcia, H.M.4    Onuma, Y.5    Ligthart, J.6
  • 26
    • 73649145753 scopus 로고    scopus 로고
    • Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study
    • (epub ahead of print)
    • Kim JS, Fan C, Choi D, Jang IK, Lee JM, Kim TH, et al. Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study. Int J Cardiol. 2009; 24 (epub ahead of print).
    • (2009) Int J Cardiol , pp. 24
    • Kim, J.S.1    Fan, C.2    Choi, D.3    Jang, I.K.4    Lee, J.M.5    Kim, T.H.6
  • 28
    • 33748684390 scopus 로고    scopus 로고
    • Measurement of the thickness of the fibrous cap by optical coherence tomography
    • Kume T, Akasaka T, Kawamoto T, Okura H, Watanabe N, Toyota E, et al. Measurement of the thickness of the fibrous cap by optical coherence tomography. Am Heart J. 2006; 152: e1-4.
    • (2006) Am Heart J. , vol.152
    • Kume, T.1    Akasaka, T.2    Kawamoto, T.3    Okura, H.4    Watanabe, N.5    Toyota, E.6
  • 29
    • 58549095873 scopus 로고    scopus 로고
    • Effect of statin therapy on coronary fibrous-cap thickness in patients with acute coronary syndrome: assessment by optical coherence tomography study
    • Takarada S, Imanishi T, Kubo T, Tanimoto T, Kitabata H, Nakamura N, et al. Effect of statin therapy on coronary fibrous-cap thickness in patients with acute coronary syndrome: assessment by optical coherence tomography study. Atherosclerosis. 2009; 202: 491-7.
    • (2009) Atherosclerosis. , vol.202 , pp. 491-497
    • Takarada, S.1    Imanishi, T.2    Kubo, T.3    Tanimoto, T.4    Kitabata, H.5    Nakamura, N.6
  • 30
    • 20144388778 scopus 로고    scopus 로고
    • In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography
    • Jang IK, Tearney GJ, MacNeill B, Takano M, Moselewski F, Iftima N, et al. In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography. Circulation. 2005; 111: 1551-5.
    • (2005) Circulation. , vol.111 , pp. 1551-1555
    • Jang, I.K.1    Tearney, G.J.2    MacNeill, B.3    Takano, M.4    Moselewski, F.5    Iftima, N.6
  • 31
    • 34548161312 scopus 로고    scopus 로고
    • Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy
    • Kubo T, Imanishi T, Takarada S, Kuroi A, Ueno S, Yamano T, et al. Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy. J Am Coll Cardiol. 2007; 50: 933-9.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 933-939
    • Kubo, T.1    Imanishi, T.2    Takarada, S.3    Kuroi, A.4    Ueno, S.5    Yamano, T.6
  • 32
    • 38849108719 scopus 로고    scopus 로고
    • In vivo comparison of optical coherence tomography and angioscopy for the evaluation of coronary plaque characteristics
    • Takano M, Jang IK, Inami S, Yamamoto M, Murakami D, Okamatsu K, et al. In vivo comparison of optical coherence tomography and angioscopy for the evaluation of coronary plaque characteristics. Am J Cardiol. 2008; 101: 471-6.
    • (2008) Am J Cardiol , vol.101 , pp. 471-476
    • Takano, M.1    Jang, I.K.2    Inami, S.3    Yamamoto, M.4    Murakami, D.5    Okamatsu, K.6
  • 33
    • 41249087112 scopus 로고    scopus 로고
    • Implication of plaque color classification for assessing plaque vulnerability: a coronary angioscopy and optical coherence tomography investigation
    • Kubo T, Imanishi T, Takarada S, Kuroi A, Ueno S, Yamano T, et al. Implication of plaque color classification for assessing plaque vulnerability: a coronary angioscopy and optical coherence tomography investigation. JACC Cardiovasc Interv. 2008; 1: 74-80.
    • (2008) JACC Cardiovasc Interv. , vol.1 , pp. 74-80
    • Kubo, T.1    Imanishi, T.2    Takarada, S.3    Kuroi, A.4    Ueno, S.5    Yamano, T.6
  • 35
    • 77953748337 scopus 로고    scopus 로고
    • The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study
    • Ozaki Y, Okumura M, Ismail TF, Naruse H, Hattori K, Kan S, et al. The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study. Eur Heart J. 2010; 31: 1470-6.
    • (2010) Eur Heart J , vol.31 , pp. 1470-1476
    • Ozaki, Y.1    Okumura, M.2    Ismail, T.F.3    Naruse, H.4    Hattori, K.5    Kan, S.6
  • 36
    • 70349869224 scopus 로고    scopus 로고
    • Factors that influence measurements and accurate evaluation of stent apposition by optical coherence tomography. Assessment using a phantom model
    • Sawada T, Shite J, Negi N, Shinke T, Tanino Y, Ogasawara D, et al. Factors that influence measurements and accurate evaluation of stent apposition by optical coherence tomography. Assessment using a phantom model. Circ J. 2009; 73: 1841-7.
    • (2009) Circ J. , vol.73 , pp. 1841-1847
    • Sawada, T.1    Shite, J.2    Negi, N.3    Shinke, T.4    Tanino, Y.5    Ogasawara, D.6
  • 37
    • 78049478358 scopus 로고    scopus 로고
    • The effects of drug-eluting stent polymer on measurement of strut thickness by optical coherence tomography: in vitro comparison with bare-metal stent
    • Mizuno M, Takano M, Mizuno K. The effects of drug-eluting stent polymer on measurement of strut thickness by optical coherence tomography: in vitro comparison with bare-metal stent. Int J Cardiol. 2010; 145: 48-9.
    • (2010) Int J Cardiol , vol.145 , pp. 48-49
    • Mizuno, M.1    Takano, M.2    Mizuno, K.3
  • 38
    • 41949118345 scopus 로고    scopus 로고
    • In vivo comparison between optical coherence tomography and intravascular ultrasound for detecting small degrees of in-stent neointima after stent implantation
    • Suzuki Y, Ikeno F, Koizumi T, Tio F, Yeung AC, Yock PG, et al. In vivo comparison between optical coherence tomography and intravascular ultrasound for detecting small degrees of in-stent neointima after stent implantation. JACC Cardiovasc Interv. 2008; 1: 168-73.
    • (2008) JACC Cardiovasc Interv. , vol.1 , pp. 168-173
    • Suzuki, Y.1    Ikeno, F.2    Koizumi, T.3    Tio, F.4    Yeung, A.C.5    Yock, P.G.6
  • 39
    • 38749093780 scopus 로고    scopus 로고
    • Does optical coherence tomography identify arterial healing after stenting? An in vivo comparison with histology, in a rabbit carotid model
    • Prati F, Zimarino M, Stabile E, Pizzicannella G, Fouad T, Rabozzi R, et al. Does optical coherence tomography identify arterial healing after stenting? An in vivo comparison with histology, in a rabbit carotid model. Heart. 2008; 94: 217-21.
    • (2008) Heart. , vol.94 , pp. 217-221
    • Prati, F.1    Zimarino, M.2    Stabile, E.3    Pizzicannella, G.4    Fouad, T.5    Rabozzi, R.6
  • 40
    • 71049115883 scopus 로고    scopus 로고
    • Accuracy and reproducibility of stent-strut thickness determined by optical coherence tomography
    • Terashima M, Rathore S, Suzuki Y, Nakamura Y, Kaneda H, Nasu K, et al. Accuracy and reproducibility of stent-strut thickness determined by optical coherence tomography. J Invasive Cardiol. 2009; 21: 602-5.
    • (2009) J Invasive Cardiol. , vol.21 , pp. 602-605
    • Terashima, M.1    Rathore, S.2    Suzuki, Y.3    Nakamura, Y.4    Kaneda, H.5    Nasu, K.6
  • 41
    • 73649133689 scopus 로고    scopus 로고
    • Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation
    • Murata A, Wallace-Bradley D, Tellez A, Alviar C, Aboodi M, Sheehy A, et al. Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation. JACC Cardiovasc Imaging. 2010; 3: 76-84.
    • (2010) JACC Cardiovasc Imaging. , vol.3 , pp. 76-84
    • Murata, A.1    Wallace-Bradley, D.2    Tellez, A.3    Alviar, C.4    Aboodi, M.5    Sheehy, A.6
  • 42
    • 41949137318 scopus 로고    scopus 로고
    • Safety and feasibility of an intravascular optical coherence tomography imagewire system in the clinical setting
    • Yamaguchi T, Terashima M, Akasaka T, Hayashi T, Mizuno K, Muramatsu T, et al. Safety and feasibility of an intravascular optical coherence tomography imagewire system in the clinical setting. Am J Cardiol. 2008; 101: 562-7.
    • (2008) Am J Cardiol , vol.101 , pp. 562-567
    • Yamaguchi, T.1    Terashima, M.2    Akasaka, T.3    Hayashi, T.4    Mizuno, K.5    Muramatsu, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.