메뉴 건너뛰기




Volumn 134, Issue 11, 2012, Pages

Pulse-wave propagation in straight-geometry vessels for stiffness estimation: Theory, simulations, phantoms and in vitro findings

Author keywords

aortic pulse wave velocity (PWV); arterial stiffness; fluid structure interaction (FSI) simulation; pulse wave imaging (PWI)

Indexed keywords

ARTERIAL STIFFNESS; CANINE AORTA; COMBINED SIMULATION; IN-VITRO; IN-VIVO; LINEAR CORRELATION; MODEL PARAMETERS; NONINVASIVE CHARACTERIZATIONS; PHANTOM STUDIES; PULSE WAVE; PULSE WAVE ANALYSIS; PULSE WAVE PROPAGATION; PULSE WAVE VELOCITY; RADIO FREQUENCIES;

EID: 84874160854     PISSN: 01480731     EISSN: 15288951     Source Type: Journal    
DOI: 10.1115/1.4007747     Document Type: Article
Times cited : (42)

References (35)
  • 1
    • 0024440224 scopus 로고
    • Pulse pressure in essential hypertension: Clinical and therapeutical implications
    • Safar, M., 1989, "Pulse Pressure in Essential Hypertension: Clinical and Therapeutical Implications," Hypertension, 7(10), pp. 769-776. (Pubitemid 19281809)
    • (1989) Journal of Hypertension , vol.7 , Issue.10 , pp. 769-776
    • Safar, M.E.1
  • 4
    • 0000490399 scopus 로고
    • Uber die fortpflanzungsgeschwindigkeit des schalles in elastiischen rohren
    • Korteweg, D., 1878, "Uber Die Fortpflanzungsgeschwindigkeit Des Schalles in Elastiischen Rohren," Ann. Phys. Chem., 5, pp. 52-537.
    • (1878) Ann. Phys. Chem , vol.5 , pp. 52-537
    • Korteweg, D.1
  • 8
    • 0035997365 scopus 로고    scopus 로고
    • Methods and devices for measuring arterial compliance in humans
    • DOI 10.1016/S0895-7061(02)02962-X, PII S089570610202962X
    • Pannier, B., Avolio, A., Hoeks, A., Mancia, G., and Takazawa, K., 2002, "Methods and Devices for Measuring Arterial Compliance in Humans," Am. J. Hypertens., 15(8), pp. 743-753. (Pubitemid 34804283)
    • (2002) American Journal of Hypertension , vol.15 , Issue.8 , pp. 743-753
    • Pannier, B.M.1    Avolio, A.P.2    Hoeks, A.3    Mancia, G.4    Takazawa, K.5
  • 9
    • 0037358035 scopus 로고    scopus 로고
    • Pulse wave analysis and pulse wave velocity: A critical review of their strengths and weaknesses
    • DOI 10.1097/00004872-200303000-00004
    • Davies, J., and Struthers, A., 2003, "Pulse Wave Analysis and Pulse Wave Velocity: A Critical Review of Their Strengths and Weaknesses," Hypertension, 21(3), pp. 463-472. (Pubitemid 36418950)
    • (2003) Journal of Hypertension , vol.21 , Issue.3 , pp. 463-472
    • Davies, J.I.1    Struthers, A.D.2
  • 10
    • 77949654916 scopus 로고    scopus 로고
    • Pulse wave imaging for noninvasive and quantitative measurement of arterial stiffness in vivo
    • Vappou, J., Luo, J., and Konofagou, E., 2010, "Pulse Wave Imaging for Noninvasive and Quantitative Measurement of Arterial Stiffness In Vivo," Am. J. Hypertens., 23(4), pp. 393-398.
    • (2010) Am. J. Hypertens , vol.23 , Issue.4 , pp. 393-398
    • Vappou, J.1    Luo, J.2    Konofagou, E.3
  • 11
    • 84864774942 scopus 로고    scopus 로고
    • Detection of aortic wall inclusions using regional pulse wave propagation and velocity in silico
    • Shahmirzadi, D., and Konofagou, E., 2012, "Detection of Aortic Wall Inclusions Using Regional Pulse Wave Propagation and Velocity in Silico," Artery Res., 6(3), pp. 114-123.
    • (2012) Artery Res , vol.6 , Issue.3 , pp. 114-123
    • Shahmirzadi, D.1    Konofagou, E.2
  • 13
    • 0032409973 scopus 로고    scopus 로고
    • A noninvasive method to estimate pulse wave velocity in arteries locally by means of ultrasound
    • DOI 10.1016/S0301-5629(98)00126-4, PII S0301562998001264
    • Brands, P., Willigers, J., Ledoux, L., Reneman, R., and Hoeks, A., 1998, "A Noninvasive Method to Estimate Pulse Wave Velocity in Arteries Locally by Means of Ultrasound," Ultrasound Med. Biol., 24(9), pp. 1325-1335. (Pubitemid 29003655)
    • (1998) Ultrasound in Medicine and Biology , vol.24 , Issue.9 , pp. 1325-1335
    • Brands, P.J.1    Willigers, J.M.2    Ledoux, L.A.F.3    Reneman, R.S.4    Hoeks, A.P.G.5
  • 16
    • 4043057300 scopus 로고    scopus 로고
    • Computer-assisted evaluation of aortic stiffness using data acquired via magnetic resonance
    • DOI 10.1016/j.compmedimag.2004.04.006, PII S0895611104000552
    • Shao, X., Fei, D., and Kraft, K., 2004, "Computer-Assisted Evaluation of Aortic Stiffness Using Data Acquired via Magnetic Resonance," Comput. Med. Imaging Graph., 28(6), pp. 353-361. (Pubitemid 39061023)
    • (2004) Computerized Medical Imaging and Graphics , vol.28 , Issue.6 , pp. 353-361
    • Shao, X.1    Fei, D.-Y.2    Kraft, K.A.3
  • 17
    • 37349126923 scopus 로고    scopus 로고
    • A novel noninvasive technique for pulse-wave imaging and characterization of clinically-significant vascular mechanical properties in vivo
    • Fujikura, K., Luo, J., Gamarnik, V., Pernot, M., Fukumoto, R., Tilson, M., and Konofagou, E., 2007, "A Novel Noninvasive Technique for Pulse-Wave Imaging and Characterization of Clinically-Significant Vascular Mechanical Properties In Vivo," Ultrason. Imaging, 29(3), pp. 137-154, available at: http://orion. bme.columbia.edu/ueil/documents/article/2007-fujikura-pwi- technique.pdf (Pubitemid 350287635)
    • (2007) Ultrasonic Imaging , vol.29 , Issue.3 , pp. 137-154
    • Fujikura, K.1    Luo, J.2    Gamarnik, V.3    Pernot, M.4    Fukumoto, R.5    Tilson III, M.D.6    Konofagou, E.E.7
  • 18
    • 80054064781 scopus 로고    scopus 로고
    • Regional measurement of arterial stiffness using pulse wave imaging: Phantom validation and preliminary clinical results
    • San Diego, CA
    • Vappou, J., Luo, J., and Konofagou, E., 2010, "Regional Measurement of Arterial Stiffness Using Pulse Wave Imaging: Phantom Validation and Preliminary Clinical Results," Proceedings of the IEEE Ultrasonics Symposium, San Diego, CA, pp. 1332-1335.
    • (2010) Proceedings of the IEEE Ultrasonics Symposium , pp. 1332-1335
    • Vappou, J.1    Luo, J.2    Konofagou, E.3
  • 20
    • 79956197688 scopus 로고    scopus 로고
    • Aortic pulse wave velocity measured by pulse wave imaging (pwi): A comparison with applanation tonometry
    • Vappou, J., Luo, J., Okajima, K., Tullio, M., and Konofagou, E., 2011, "Aortic Pulse Wave Velocity Measured by Pulse Wave Imaging (PWI): A Comparison With Applanation Tonometry," Artery Res., 5(2), pp. 65-71.
    • (2011) Artery Res , vol.5 , Issue.2 , pp. 65-71
    • Vappou, J.1    Luo, J.2    Okajima, K.3    Tullio, M.4    Konofagou, E.5
  • 21
    • 33745862995 scopus 로고    scopus 로고
    • Fluid structure interaction of patient specific abdominal aortic aneurysms: A comparison with solid stress models
    • Leung, J. H., Wright, A. R., Cheshire, N., Crane, J., Thom, S. A., Hughes, A. D., and Xu, Y., 2006, "Fluid Structure Interaction of Patient Specific Abdominal Aortic Aneurysms: A Comparison With Solid Stress Models," Biomed. Eng. Online, 5(33), pp. 1-15.
    • (2006) Biomed. Eng. Online , vol.5 , Issue.33 , pp. 1-15
    • Leung, J.H.1    Wright, A.R.2    Cheshire, N.3    Crane, J.4    Thom, S.A.5    Hughes, A.D.6    Xu, Y.7
  • 23
    • 65549089739 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm risk of rupture: Patient-specific fsi simulations using anisotropic model
    • Rissland, P., Alemu, Y., Einav, S., Ricotta, J., and Bluestein, D., 2009, "Abdominal Aortic Aneurysm Risk of Rupture: Patient-Specific FSI Simulations Using Anisotropic Model," ASME J. Biomech. Eng., 131(3), pp. 031001.
    • (2009) ASME J. Biomech. Eng , vol.131 , Issue.3 , pp. 031001
    • Rissland, P.1    Alemu, Y.2    Einav, S.3    Ricotta, J.4    Bluestein, D.5
  • 24
    • 77956307228 scopus 로고    scopus 로고
    • A two-system, single-analysis, fluid-structure interaction technique for modelling abdominal aortic aneurysms
    • Kelly, S. C., and O'Rourke, M. J., 2011, "A Two-System, Single-Analysis, Fluid-Structure Interaction Technique for Modelling Abdominal Aortic Aneurysms," Proc. Inst. Mech. Eng., Part H: J. Eng. Med., 224(8), pp. 955-969.
    • (2011) Proc. Inst. Mech. Eng., Part H: J. Eng. Med , vol.224 , Issue.8 , pp. 955-969
    • Kelly, S.C.1    O'Rourke, M.J.2
  • 25
    • 51649130465 scopus 로고    scopus 로고
    • Wall stress and flow dynamics in abdominal aortic aneurysms: Finite element analysis vs. Fluid-structure interaction
    • Scotti, C. M., Jimenez, J., Muluk, S. C., and Finol, E. A., 2008, "Wall Stress and Flow Dynamics in Abdominal Aortic Aneurysms: Finite Element Analysis vs. Fluid-Structure Interaction," Comput. Methods Biomech. Biomed. Eng., 11(3), pp. 301-322.
    • (2008) Comput. Methods Biomech. Biomed. Eng , vol.11 , Issue.3 , pp. 301-322
    • Scotti, C.M.1    Jimenez, J.2    Muluk, S.C.3    Finol, E.A.4
  • 26
    • 67649319927 scopus 로고    scopus 로고
    • Finite element modeling of the pulse wave propagation in the aorta for simulation of the pulse wave imaging (PWI) Method
    • New York, NY
    • Vappou, J., Zervantonakis, I., Luo, J., and Konofagou, E. E., 2008, "Finite Element Modeling of the Pulse Wave Propagation in the Aorta for Simulation of the Pulse Wave Imaging (PWI) Method," Computational Biomechanics for Medicine (MICCAI 2008 Workshop), New York, NY, pp. 118-127.
    • (2008) Computational Biomechanics for Medicine (MICCAI 2008 Workshop) , pp. 118-127
    • Vappou, J.1    Zervantonakis, I.2    Luo, J.3    Konofagou, E.E.4
  • 27
    • 0016555309 scopus 로고
    • Anisotropic properties of the canine carotid artery in vitro
    • Cox, R., 1975, "Anisotropic Properties of the Canine Carotid Artery In Vitro," Biomechanics, 8(5), pp. 293-300.
    • (1975) Biomechanics , vol.8 , Issue.5 , pp. 293-300
    • Cox, R.1
  • 29
    • 0028942558 scopus 로고
    • Fundamentals of microwaves
    • Kaatze, U., 1995, "Fundamentals of Microwaves," Radiat. Phys. Chem., 45(4), pp. 539-548.
    • (1995) Radiat. Phys. Chem , vol.45 , Issue.4 , pp. 539-548
    • Kaatze, U.1
  • 31
    • 26044462600 scopus 로고    scopus 로고
    • Bursting tension of medium and large canine arteries sealed with ultrasonic energy or suture ligation
    • Bubenik, L. J., Hosgood, G., and Vasanjee, S. C., 2005, "Bursting Tension of Medium and Large Canine Arteries Sealed With Ultrasonic Energy or Suture Ligation," Vet. Surg., 34(3), pp. 289-293.
    • (2005) Vet. Surg , vol.34 , Issue.3 , pp. 289-293
    • Bubenik, L.J.1    Hosgood, G.2    Vasanjee, S.C.3
  • 32
    • 0018452142 scopus 로고
    • Axial mechanical properties of arterial walls and their anisotropy
    • Sato, M., Hayashi, K., Niimi, H., Moritake, K., Okumura, A., and Handa, H., 1979, "Axial Mechanical Properties of Arterial Walls and Their Anisotropy," Med. Biol. Eng. Comput., 17(2), pp. 170-176. (Pubitemid 9132894)
    • (1979) Medical and Biological Engineering and Computing , vol.17 , Issue.2 , pp. 170-176
    • Sato, M.1    Hayashi, K.2    Niimi, H.3
  • 33
    • 0013939690 scopus 로고
    • Collagen and elastin content in canine arteries selected from functionally different vascular beds
    • Fischer, G., and Llaurado, J., 1966, "Collagen and Elastin Content in Canine Arteries Selected from Functionally Different Vascular Beds," Circ. Res., 19(2), pp. 394-399.
    • (1966) Circ. Res , vol.19 , Issue.2 , pp. 394-399
    • Fischer, G.1    Llaurado, J.2
  • 34
    • 77953257554 scopus 로고    scopus 로고
    • A fast normalized cross-correlation calculation method for motion estimation
    • Luo, J., and Konofagou, E., 2010, "A Fast Normalized Cross-Correlation Calculation Method for Motion Estimation," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 57(6), pp. 1347-1357.
    • (2010) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.57 , Issue.6 , pp. 1347-1357
    • Luo, J.1    Konofagou, E.2
  • 35
    • 0000441923 scopus 로고
    • The poisson's ratio in polymer gels
    • Geissler, E., and Hecht, A. M., 1980, "The Poisson's Ratio in Polymer Gels," Macromolecules, 13(5), pp. 1276-1280.
    • (1980) Macromolecules , vol.13 , Issue.5 , pp. 1276-1280
    • Geissler, E.1    Hecht, A.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.