메뉴 건너뛰기




Volumn 85, Issue 2, 2013, Pages 132-136

Home mechanical ventilation through mask: Monitoring leakage and nocturnal oxygenation at home

Author keywords

Home monitoring; Home noninvasive mechanical ventilation; Leaks in noninvasive ventilation; Noninvasive mechanical ventilation

Indexed keywords

ADULT; AIRWAY PRESSURE; ARTICLE; ARTIFICIAL VENTILATION; CHRONIC OBSTRUCTIVE LUNG DISEASE; CLINICAL ARTICLE; CROSS-SECTIONAL STUDY; FEMALE; HOME MONITORING; HUMAN; INSPIRATORY CAPACITY; MALE; NEUROMUSCULAR DISEASE; OBESITY HYPOVENTILATION SYNDROME; OBSERVATIONAL STUDY; OUTPATIENT CARE; OXYGEN SATURATION; OXYGENATION; PRIORITY JOURNAL; PULSE OXIMETRY; THERAPY EFFECT; THORAX DISEASE; VENTILATED PATIENT; AGED; ARTERIAL GAS; FACE MASK; HOME NONINVASIVE MECHANICAL VENTILATION; HUMIDIFIER; INSPIRATORY POSITIVE AIRWAY PRESSURE; NOCTURNAL HOME PULSE OXIMETRY; NONINVASIVE VENTILATION; NONINVASIVE VENTILATION LEAK; OXYGEN THERAPY; POSITIVE END EXPIRATORY PRESSURE;

EID: 84874118904     PISSN: 00257931     EISSN: 14230356     Source Type: Journal    
DOI: 10.1159/000341983     Document Type: Article
Times cited : (14)

References (10)
  • 1
    • 79251560329 scopus 로고    scopus 로고
    • SomnoNIV group: Ventilator modes and settings during non-invasive ventilation: Effects on respiratory events and implications for their identification
    • Rabec C, Rodenstein D, Leger P, Rouault S, Perrin C, Gonzalez-Bermejo J, SomnoNIV group: Ventilator modes and settings during non-invasive ventilation: effects on respiratory events and implications for their identification. Thorax 2011; 66:170-178.
    • (2011) Thorax , vol.66 , pp. 170-178
    • Rabec, C.1    Rodenstein, D.2    Leger, P.3    Rouault, S.4    Perrin, C.5    Gonzalez-Bermejo, J.6
  • 2
    • 62149096812 scopus 로고    scopus 로고
    • Intentional leaks in industrial masks have a significant impact on efficacy of bilevel noninvasive ventilation: A bench test study
    • Borel JC, Sabil A, Janssens JP, Couteau M, Boulon L, Lévy P, Pépin JL: Intentional leaks in industrial masks have a significant impact on efficacy of bilevel noninvasive ventilation: a bench test study. Chest 2009; 135: 669-677.
    • (2009) Chest , vol.135 , pp. 669-677
    • Borel, J.C.1    Sabil, A.2    Janssens, J.P.3    Couteau, M.4    Boulon, L.5    Lévy, P.6    Pépin, J.L.7
  • 3
    • 0029057274 scopus 로고
    • Sleep fragmentation in kyphoscoliotic individuals with alveolar hypoventilation treated by NIPPV
    • Bach JR, Robert D, Leger P, Langevin B: Sleep fragmentation in kyphoscoliotic individuals with alveolar hypoventilation treated by NIPPV. Chest 1995; 107: 1552-1558.
    • (1995) Chest , vol.107 , pp. 1552-1558
    • Bach, J.R.1    Robert, D.2    Leger, P.3    Langevin, B.4
  • 4
    • 0033394967 scopus 로고    scopus 로고
    • Effect of mouthleak on effectiveness of nasal bilevel ventilatory assistance and sleep architecture
    • Teschler H, Stampa J, Ragette R, Konietzko N, Berthon-Jones M: Effect of mouthleak on effectiveness of nasal bilevel ventilatory assistance and sleep architecture. Eur Respir J 1999; 14:1251-1257.
    • (1999) Eur Respir J , vol.14 , pp. 1251-1257
    • Teschler, H.1    Stampa, J.2    Ragette, R.3    Konietzko, N.4    Berthon-Jones, M.5
  • 6
    • 78650003567 scopus 로고    scopus 로고
    • Predictors of mortality in chest wall disease treated with noninvasive home mechanical ventilation
    • Martí S, Pallero M, Ferrer J, Ríos J, Rodrí-guez E, Morell F, Muñoz X: Predictors of mortality in chest wall disease treated with noninvasive home mechanical ventilation. Respir Med 2010; 104:1843-1849.
    • (2010) Respir Med , vol.104 , pp. 1843-1849
    • Martí, S.1    Pallero, M.2    Ferrer, J.3    Ríos, J.4    Rodrí-Guez, E.5    Morell, F.6    Muñoz, X.7
  • 8
    • 79955039223 scopus 로고    scopus 로고
    • Nocturnal monitoring of home non-invasive ventilation: The contribution of simple tools such as pulse oximetry, capnogra-phy, built-in ventilator software and auto-nomic markers of sleep fragmentation (review)
    • SomnoNIV Group
    • Janssens JP, Borel JC, Pépin JL, SomnoNIV Group: Nocturnal monitoring of home non-invasive ventilation: the contribution of simple tools such as pulse oximetry, capnogra-phy, built-in ventilator software and auto-nomic markers of sleep fragmentation (review). Thorax 2011; 66:438-445.
    • (2011) Thorax , vol.66 , pp. 438-445
    • Janssens, J.P.1    Borel, J.C.2    Pépin, J.L.3
  • 9
    • 84856741308 scopus 로고    scopus 로고
    • Monitoring of non-invasive ventilation by built-in software of home bilevel ventilators: A bench study
    • Contal O, Vignaux L, Combescure C, Pepin JL, Jolliet P, Janssens JP: Monitoring of non-invasive ventilation by built-in software of home bilevel ventilators: a bench study. Chest 2012; 141:469-476.
    • (2012) Chest , vol.141 , pp. 469-476
    • Contal, O.1    Vignaux, L.2    Combescure, C.3    Pepin, J.L.4    Jolliet, P.5    Janssens, J.P.6
  • 10
    • 28144448366 scopus 로고    scopus 로고
    • Effects of gas leak on triggering function, humidification, and inspi-ratory oxygen fraction during noninvasive positive airway pressure ventilation
    • Miyoshi E, Fujino Y, Uchiyama A, Mashimo T, Nishimura M: Effects of gas leak on triggering function, humidification, and inspi-ratory oxygen fraction during noninvasive positive airway pressure ventilation. Chest 2005; 128:3691-3698.
    • (2005) Chest , vol.128 , pp. 3691-3698
    • Miyoshi, E.1    Fujino, Y.2    Uchiyama, A.3    Mashimo, T.4    Nishimura, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.