메뉴 건너뛰기




Volumn 81, Issue 3, 2013, Pages 481-487

Optical coherence tomography evaluation of drug-eluting stents: A systematic review

Author keywords

coronary artery disease; optical coherence tomography; restenosis

Indexed keywords

EVEROLIMUS; PACLITAXEL; ZOTAROLIMUS;

EID: 84874118551     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.24327     Document Type: Review
Times cited : (17)

References (61)
  • 4
    • 78751623656 scopus 로고    scopus 로고
    • Coronary responses and differential mechanisms of late stent thrombosis attributed to first-generation sirolimus- and paclitaxel-eluting stents
    • Nakazawa G, Finn AV, Vorpahl M, Ladich ER, Kolodgie FD, Virmani R,. Coronary responses and differential mechanisms of late stent thrombosis attributed to first-generation sirolimus- and paclitaxel-eluting stents. J Am Coll Cardiol 2011; 57: 390-398.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 390-398
    • Nakazawa, G.1    Finn, A.V.2    Vorpahl, M.3    Ladich, E.R.4    Kolodgie, F.D.5    Virmani, R.6
  • 8
    • 77958552788 scopus 로고    scopus 로고
    • Different patterns of vascular response between patients with or without diabetes mellitus after drug-eluting stent implantation: Optical coherence tomographic analysis
    • Tanaka N, Terashima M, Rathore S, Itoh T, Habara M, Nasu K, Kimura M, Kinoshita Y, Ehara M, Tsuchikane E, et al. Different patterns of vascular response between patients with or without diabetes mellitus after drug-eluting stent implantation: Optical coherence tomographic analysis. JACC Cardiovasc Interv 2010; 3: 1074-1079.
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 1074-1079
    • Tanaka, N.1    Terashima, M.2    Rathore, S.3    Itoh, T.4    Habara, M.5    Nasu, K.6    Kimura, M.7    Kinoshita, Y.8    Ehara, M.9    Tsuchikane, E.10
  • 9
    • 78951483028 scopus 로고    scopus 로고
    • Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study
    • Kim JS, Fan C, Choi D, Jang IK, Lee JM, Kim TH, Park SM, Paik SI, Ko YG, Hong MK, et al. Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study. Int J Cardiol 2011; 146: 341-346.
    • (2011) Int J Cardiol , vol.146 , pp. 341-346
    • Kim, J.S.1    Fan, C.2    Choi, D.3    Jang, I.K.4    Lee, J.M.5    Kim, T.H.6    Park, S.M.7    Paik, S.I.8    Ko, Y.G.9    Hong, M.K.10
  • 10
    • 42549117199 scopus 로고    scopus 로고
    • Neointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography
    • Chen BX, Ma FY, Luo W, Ruan JH, Xie WL, Zhao XZ, Sun SH, Guo XM, Wang F, Tian T, et al. Neointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography. Heart 2008; 94: 566-570.
    • (2008) Heart , vol.94 , pp. 566-570
    • Chen, B.X.1    Ma, F.Y.2    Luo, W.3    Ruan, J.H.4    Xie, W.L.5    Zhao, X.Z.6    Sun, S.H.7    Guo, X.M.8    Wang, F.9    Tian, T.10
  • 11
    • 77953748337 scopus 로고    scopus 로고
    • The fate of incomplete stent apposition with drug-eluting stents: An optical coherence tomography-based natural history study
    • Ozaki Y, Okumura M, Ismail TF, Naruse H, Hattori K, Kan S, Ishikawa M, Kawai T, Takagi Y, Ishii J, et al. The fate of incomplete stent apposition with drug-eluting stents: An optical coherence tomography-based natural history study. Eur Heart J 2010; 31: 1470-1476.
    • (2010) Eur Heart J , vol.31 , pp. 1470-1476
    • Ozaki, Y.1    Okumura, M.2    Ismail, T.F.3    Naruse, H.4    Hattori, K.5    Kan, S.6    Ishikawa, M.7    Kawai, T.8    Takagi, Y.9    Ishii, J.10
  • 12
    • 79251536249 scopus 로고    scopus 로고
    • Strut coverage and late malapposition with paclitaxel-eluting stents compared with bare metal stents in acute myocardial infarction: Optical coherence tomography substudy of the harmonizing outcomes with revascularization and stents in acute myocardial infarction (HORIZONS-AMI) trial
    • Guagliumi G, Costa MA, Sirbu V, Musumeci G, Bezerra HG, Suzuki N, Matiashvili A, Lortkipanidze N, Mihalcsik L, Trivisonno A, et al. Strut coverage and late malapposition with paclitaxel-eluting stents compared with bare metal stents in acute myocardial infarction: Optical coherence tomography substudy of the harmonizing outcomes with revascularization and stents in acute myocardial infarction (HORIZONS-AMI) trial. Circulation 2011; 123: 274-281.
    • (2011) Circulation , vol.123 , pp. 274-281
    • Guagliumi, G.1    Costa, M.A.2    Sirbu, V.3    Musumeci, G.4    Bezerra, H.G.5    Suzuki, N.6    Matiashvili, A.7    Lortkipanidze, N.8    Mihalcsik, L.9    Trivisonno, A.10
  • 14
    • 83955163002 scopus 로고    scopus 로고
    • Long-term (>/=2 years) follow-up optical coherence tomographic study after sirolimus- and paclitaxel-eluting stent implantation: Comparison to 9-month follow-up results
    • Kim TH, Kim JS, Kim BK, Ko YG, Choi D, Jang Y, Hong MK,. Long-term (>/=2 years) follow-up optical coherence tomographic study after sirolimus- and paclitaxel-eluting stent implantation: Comparison to 9-month follow-up results. Int J Cardiovasc Imaging 2011; 27: 875-881.
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 875-881
    • Kim, T.H.1    Kim, J.S.2    Kim, B.K.3    Ko, Y.G.4    Choi, D.5    Jang, Y.6    Hong, M.K.7
  • 15
    • 78650159117 scopus 로고    scopus 로고
    • Late vascular responses from 2 to 4 years after implantation of sirolimus-eluting stents: Serial observations by intracoronary optical coherence tomography
    • Takano M, Yamamoto M, Mizuno M, Murakami D, Inami T, Kimata N, Murai K, Kobayashi N, Okamatsu K, Ohba T, et al. Late vascular responses from 2 to 4 years after implantation of sirolimus-eluting stents: Serial observations by intracoronary optical coherence tomography. Circ Cardiovasc Interv 2010; 3: 476-483.
    • (2010) Circ Cardiovasc Interv , vol.3 , pp. 476-483
    • Takano, M.1    Yamamoto, M.2    Mizuno, M.3    Murakami, D.4    Inami, T.5    Kimata, N.6    Murai, K.7    Kobayashi, N.8    Okamatsu, K.9    Ohba, T.10
  • 16
    • 80054050938 scopus 로고    scopus 로고
    • Evaluation of neointimal coverage and thrombosis at 3 months and 2 years post sirolimus-eluting stent implantation by optical coherence tomography
    • Xie Y, He SH, Gu X, Xu RX, Masamichi T, Kyoichi M,. [Evaluation of neointimal coverage and thrombosis at 3 months and 2 years post sirolimus-eluting stent implantation by optical coherence tomography]. Zhonghua Xin Xue Guan Bing Za Zhi 2010; 38: 116-120.
    • (2010) Zhonghua Xin Xue Guan Bing Za Zhi , vol.38 , pp. 116-120
    • Xie, Y.1    He, S.H.2    Gu, X.3    Xu, R.X.4    Masamichi, T.5    Kyoichi, M.6
  • 18
    • 51749118724 scopus 로고    scopus 로고
    • Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare-metal stent three months after implantation
    • Xie Y, Takano M, Murakami D, Yamamoto M, Okamatsu K, Inami S, Seimiya K, Ohba T, Seino Y, Mizuno K,. Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare-metal stent three months after implantation. Am J Cardiol 2008; 102: 27-31.
    • (2008) Am J Cardiol , vol.102 , pp. 27-31
    • Xie, Y.1    Takano, M.2    Murakami, D.3    Yamamoto, M.4    Okamatsu, K.5    Inami, S.6    Seimiya, K.7    Ohba, T.8    Seino, Y.9    Mizuno, K.10
  • 19
    • 34147135208 scopus 로고    scopus 로고
    • Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation
    • Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, Ohba T, Mizuno K,. Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol 2007; 99: 1033-1038.
    • (2007) Am J Cardiol , vol.99 , pp. 1033-1038
    • Takano, M.1    Inami, S.2    Jang, I.K.3    Yamamoto, M.4    Murakami, D.5    Seimiya, K.6    Ohba, T.7    Mizuno, K.8
  • 21
    • 77951723057 scopus 로고    scopus 로고
    • Comparison by optical coherence tomography of paclitaxel-eluting stents with sirolimus-eluting stents implanted in one coronary artery in one procedure. - 6-month follow-up - 6-month f
    • Miyoshi N, Shite J, Shinke T, Otake H, Tanino Y, Ogasawara D, Sawada T, Kawamori H, Kato H, Yoshino N, et al. Comparison by optical coherence tomography of paclitaxel-eluting stents with sirolimus-eluting stents implanted in one coronary artery in one procedure.-6-month follow-up-. Circ J 2010; 74: 903-908.
    • (2010) Circ J , vol.74 , pp. 903-908
    • Miyoshi, N.1    Shite, J.2    Shinke, T.3    Otake, H.4    Tanino, Y.5    Ogasawara, D.6    Sawada, T.7    Kawamori, H.8    Kato, H.9    Yoshino, N.10
  • 22
    • 69549110861 scopus 로고    scopus 로고
    • Advanced neointimal growth is not associated with a low risk of in-stent thrombus. Optical coherence tomographic findings after first-generation drug-eluting stent implantation
    • Murakami D, Takano M, Yamamoto M, Inami S, Ohba T, Seino Y, Mizuno K,. Advanced neointimal growth is not associated with a low risk of in-stent thrombus. Optical coherence tomographic findings after first-generation drug-eluting stent implantation. Circ J 2009; 73: 1627-1634.
    • (2009) Circ J , vol.73 , pp. 1627-1634
    • Murakami, D.1    Takano, M.2    Yamamoto, M.3    Inami, S.4    Ohba, T.5    Seino, Y.6    Mizuno, K.7
  • 24
    • 41649089025 scopus 로고    scopus 로고
    • Neointimal coverage of sirolimus-eluting stents 6 months and 12 months after implantation: Evaluation by optical coherence tomography
    • Yao ZH, Matsubara T, Inada T, Suzuki Y, Suzuki T,. Neointimal coverage of sirolimus-eluting stents 6 months and 12 months after implantation: Evaluation by optical coherence tomography. Chin Med J (Engl) 2008; 121: 503-507.
    • (2008) Chin Med J (Engl) , vol.121 , pp. 503-507
    • Yao, Z.H.1    Matsubara, T.2    Inada, T.3    Suzuki, Y.4    Suzuki, T.5
  • 26
    • 84870414062 scopus 로고    scopus 로고
    • Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: Comparison with sirolimus-eluting stent using optical coherence tomography
    • (in press).
    • Choi HH, Kim JS, Yoon DH, Hong KS, Kim TH, Kim BK, Ko YG, Choi D, Jang Y, Hong MK,. Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: Comparison with sirolimus-eluting stent using optical coherence tomography. Int J Cardiovasc Imaging (in press).
    • Int J Cardiovasc Imaging
    • Choi, H.H.1    Kim, J.S.2    Yoon, D.H.3    Hong, K.S.4    Kim, T.H.5    Kim, B.K.6    Ko, Y.G.7    Choi, D.8    Jang, Y.9    Hong, M.K.10
  • 27
    • 75749123502 scopus 로고    scopus 로고
    • Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation
    • Kim JS, Kim TH, Fan C, Lee JM, Kim W, Ko YG, Choi D, Hong MK, Jang Y,. Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation. Circ J 2010; 74: 320-326.
    • (2010) Circ J , vol.74 , pp. 320-326
    • Kim, J.S.1    Kim, T.H.2    Fan, C.3    Lee, J.M.4    Kim, W.5    Ko, Y.G.6    Choi, D.7    Hong, M.K.8    Jang, Y.9
  • 29
    • 77949568899 scopus 로고    scopus 로고
    • Different vascular healing patterns with various drug-eluting stents in primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: Optical coherence tomographic findings
    • Fan C, Kim JS, Lee JM, Kim TH, Park SM, Wi J, Paik SI, Ko YG, Choi D, Hong MK, et al. Different vascular healing patterns with various drug-eluting stents in primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: Optical coherence tomographic findings. Am J Cardiol 2010; 105: 972-976.
    • (2010) Am J Cardiol , vol.105 , pp. 972-976
    • Fan, C.1    Kim, J.S.2    Lee, J.M.3    Kim, T.H.4    Park, S.M.5    Wi, J.6    Paik, S.I.7    Ko, Y.G.8    Choi, D.9    Hong, M.K.10
  • 30
    • 79952276529 scopus 로고    scopus 로고
    • Assessment by optical coherence tomography of stent struts across side branch. -Comparison of bare-metal stents and drug-elution stents
    • Liu Y, Imanishi T, Kubo T, Tanaka A, Kitabata H, Tanimoto T, Ino Y, Ikejima H, Tsujioka H, Komukai K, et al. Assessment by optical coherence tomography of stent struts across side branch. -Comparison of bare-metal stents and drug-elution stents. Circ J 2010; 75: 106-112.
    • (2010) Circ J , vol.75 , pp. 106-112
    • Liu, Y.1    Imanishi, T.2    Kubo, T.3    Tanaka, A.4    Kitabata, H.5    Tanimoto, T.6    Ino, Y.7    Ikejima, H.8    Tsujioka, H.9    Komukai, K.10
  • 31
    • 72049117874 scopus 로고    scopus 로고
    • Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: Comparison with sirolimus-eluting stents
    • Kim JS, Jang IK, Kim TH, Takano M, Kume T, Hur NW, Ko YG, Choi D, Hong MK, Jang Y,. Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: Comparison with sirolimus-eluting stents. Heart 2009; 95: 1907-1912.
    • (2009) Heart , vol.95 , pp. 1907-1912
    • Kim, J.S.1    Jang, I.K.2    Kim, T.H.3    Takano, M.4    Kume, T.5    Hur, N.W.6    Ko, Y.G.7    Choi, D.8    Hong, M.K.9    Jang, Y.10
  • 32
    • 67649794838 scopus 로고    scopus 로고
    • Evaluation of neointimal coverage of overlapping sirolimus-eluting stents by optical coherence tomography
    • Tian F, Chen YD, Sun ZJ, Chen L, Yuan F, Song XT, Lu SZ,. Evaluation of neointimal coverage of overlapping sirolimus-eluting stents by optical coherence tomography. Chin Med J (Engl) 2009; 122: 670-674.
    • (2009) Chin Med J (Engl) , vol.122 , pp. 670-674
    • Tian, F.1    Chen, Y.D.2    Sun, Z.J.3    Chen, L.4    Yuan, F.5    Song, X.T.6    Lu, S.Z.7
  • 33
    • 77956146299 scopus 로고    scopus 로고
    • Strut coverage and vessel wall response to a new-generation paclitaxel-eluting stent with an ultrathin biodegradable abluminal polymer: Optical coherence tomography drug-eluting stent investigation (OCTDESI)
    • Guagliumi G, Sirbu V, Musumeci G, Bezerra HG, Aprile A, Kyono H, Fiocca L, Matiashvili A, Lortkipanidze N, Vassileva A, et al. Strut coverage and vessel wall response to a new-generation paclitaxel-eluting stent with an ultrathin biodegradable abluminal polymer: Optical coherence tomography drug-eluting stent investigation (OCTDESI). Circ Cardiovasc Interv 2010; 3: 367-375.
    • (2010) Circ Cardiovasc Interv , vol.3 , pp. 367-375
    • Guagliumi, G.1    Sirbu, V.2    Musumeci, G.3    Bezerra, H.G.4    Aprile, A.5    Kyono, H.6    Fiocca, L.7    Matiashvili, A.8    Lortkipanidze, N.9    Vassileva, A.10
  • 34
    • 80052329078 scopus 로고    scopus 로고
    • Neointimal coverage and stent strut apposition six months after implantation of a paclitaxel eluting stent in acute coronary syndromes: An optical coherence tomography study
    • Davlouros PA, Nikokiris G, Karantalis V, Mavronasiou E, Xanthopoulou I, Damelou A, Tsigkas G, Alexopoulos D,. Neointimal coverage and stent strut apposition six months after implantation of a paclitaxel eluting stent in acute coronary syndromes: An optical coherence tomography study. Int J Cardiol 2011; 151: 155-159.
    • (2011) Int J Cardiol , vol.151 , pp. 155-159
    • Davlouros, P.A.1    Nikokiris, G.2    Karantalis, V.3    Mavronasiou, E.4    Xanthopoulou, I.5    Damelou, A.6    Tsigkas, G.7    Alexopoulos, D.8
  • 35
    • 70450225250 scopus 로고    scopus 로고
    • Comparative analysis of neointimal coverage with paclitaxel and zotarolimus drug-eluting stents, using optical coherence tomography 6 months after implantation
    • Motreff P, Souteyrand G, Levesque S, Ouchchane L, Dauphin C, Sarry L, Cassagnes J, Lusson JR,. Comparative analysis of neointimal coverage with paclitaxel and zotarolimus drug-eluting stents, using optical coherence tomography 6 months after implantation. Arch Cardiovasc Dis 2009; 102: 617-624.
    • (2009) Arch Cardiovasc Dis , vol.102 , pp. 617-624
    • Motreff, P.1    Souteyrand, G.2    Levesque, S.3    Ouchchane, L.4    Dauphin, C.5    Sarry, L.6    Cassagnes, J.7    Lusson, J.R.8
  • 37
    • 72149133094 scopus 로고    scopus 로고
    • Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: The ENDEAVOR OCT trial
    • Kim JS, Jang IK, Fan C, Kim TH, Park SM, Choi EY, Lee SH, Ko YG, Choi D, Hong MK, et al. Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: The ENDEAVOR OCT trial. JACC Cardiovasc Interv 2009; 2: 1240-1247.
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 1240-1247
    • Kim, J.S.1    Jang, I.K.2    Fan, C.3    Kim, T.H.4    Park, S.M.5    Choi, E.Y.6    Lee, S.H.7    Ko, Y.G.8    Choi, D.9    Hong, M.K.10
  • 38
    • 79954633397 scopus 로고    scopus 로고
    • Spatial distribution of neo-intimal hyperplasia 6 months after zotarolimus-eluting stent implantation, analysed by optical coherence tomography
    • Souteyrand G, Levesque S, Ouchchane L, Sarry L, Eschalier R, Lusson JR, Motreff P,. Spatial distribution of neo-intimal hyperplasia 6 months after zotarolimus-eluting stent implantation, analysed by optical coherence tomography. Arch Cardiovasc Dis 2011; 104: 147-154.
    • (2011) Arch Cardiovasc Dis , vol.104 , pp. 147-154
    • Souteyrand, G.1    Levesque, S.2    Ouchchane, L.3    Sarry, L.4    Eschalier, R.5    Lusson, J.R.6    Motreff, P.7
  • 39
    • 78049422574 scopus 로고    scopus 로고
    • Strut coverage and vessel wall response to zotarolimus-eluting and bare-metal stents implanted in patients with ST-segment elevation myocardial infarction: The OCTAMI (optical coherence tomography in acute myocardial infarction) study
    • Guagliumi G, Sirbu V, Bezerra H, Biondi-Zoccai G, Fiocca L, Musumeci G, Matiashvili A, Lortkipanidze N, Tahara S, Valsecchi O, et al. Strut coverage and vessel wall response to zotarolimus-eluting and bare-metal stents implanted in patients with ST-segment elevation myocardial infarction: The OCTAMI (optical coherence tomography in acute myocardial infarction) study. JACC Cardiovasc Interv 2010; 3: 680-687.
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 680-687
    • Guagliumi, G.1    Sirbu, V.2    Bezerra, H.3    Biondi-Zoccai, G.4    Fiocca, L.5    Musumeci, G.6    Matiashvili, A.7    Lortkipanidze, N.8    Tahara, S.9    Valsecchi, O.10
  • 40
    • 84874109534 scopus 로고    scopus 로고
    • Real-time, in-vivo optical coherence tomography of human coronary artery using a dedicated imaging wire
    • (suppl 6A):129H.
    • Regar E, Schaar J, van der Giessen W, van der Steen AF, Serruys PW,. Real-time, in-vivo optical coherence tomography of human coronary artery using a dedicated imaging wire. Am J Cardiol 2002; 90 (suppl 6A):129H.
    • (2002) Am J Cardiol , pp. 90
    • Regar, E.1    Schaar, J.2    Van Der Giessen, W.3    Van Der Steen, A.F.4    Serruys, P.W.5
  • 41
    • 20044373069 scopus 로고    scopus 로고
    • Endothelial function and dysfunction. Part II: Association with cardiovascular risk factors and diseases. A statement by the Working Group on Endothelins and Endothelial Factors of the European Society of Hypertension
    • Brunner H, Cockcroft JR, Deanfield J, Donald A, Ferrannini E, Halcox J, Kiowski W, Luscher TF, Mancia G, Natali A, et al. Endothelial function and dysfunction. Part II: Association with cardiovascular risk factors and diseases. A statement by the Working Group on Endothelins and Endothelial Factors of the European Society of Hypertension. J Hypertens 2005; 23: 233-246.
    • (2005) J Hypertens , vol.23 , pp. 233-246
    • Brunner, H.1    Cockcroft, J.R.2    Deanfield, J.3    Donald, A.4    Ferrannini, E.5    Halcox, J.6    Kiowski, W.7    Luscher, T.F.8    Mancia, G.9    Natali, A.10
  • 42
    • 19944430327 scopus 로고    scopus 로고
    • Endothelial function and dysfunction. Part I: Methodological issues for assessment in the different vascular beds: A statement by the Working Group on Endothelin and Endothelial Factors of the European Society of Hypertension
    • Deanfield J, Donald A, Ferri C, Giannattasio C, Halcox J, Halligan S, Lerman A, Mancia G, Oliver JJ, Pessina AC, et al. Endothelial function and dysfunction. Part I: Methodological issues for assessment in the different vascular beds: A statement by the Working Group on Endothelin and Endothelial Factors of the European Society of Hypertension. J Hypertens 2005; 23: 7-17.
    • (2005) J Hypertens , vol.23 , pp. 7-17
    • Deanfield, J.1    Donald, A.2    Ferri, C.3    Giannattasio, C.4    Halcox, J.5    Halligan, S.6    Lerman, A.7    Mancia, G.8    Oliver, J.J.9    Pessina, A.C.10
  • 43
    • 34248219973 scopus 로고    scopus 로고
    • Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization
    • Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R,. Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization. Circulation 2007; 115: 2435-2441.
    • (2007) Circulation , vol.115 , pp. 2435-2441
    • Finn, A.V.1    Joner, M.2    Nakazawa, G.3    Kolodgie, F.4    Newell, J.5    John, M.C.6    Gold, H.K.7    Virmani, R.8
  • 48
    • 64849091370 scopus 로고    scopus 로고
    • The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography
    • Tanigawa J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C,. The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol 2009; 134: 180-188.
    • (2009) Int J Cardiol , vol.134 , pp. 180-188
    • Tanigawa, J.1    Barlis, P.2    Dimopoulos, K.3    Dalby, M.4    Moore, P.5    Di Mario, C.6
  • 50
    • 0038241919 scopus 로고    scopus 로고
    • Regional remodeling as the cause of late stent malapposition
    • Mintz GS, Shah VM, Weissman NJ,. Regional remodeling as the cause of late stent malapposition. Circulation 2003; 107: 2660-2663.
    • (2003) Circulation , vol.107 , pp. 2660-2663
    • Mintz, G.S.1    Shah, V.M.2    Weissman, N.J.3
  • 51
    • 41949111999 scopus 로고    scopus 로고
    • Stent malapposition after sirolimus-eluting and bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: Acute and 9-month intravascular ultrasound results of the MISSION! intervention study
    • van der Hoeven BL, Liem SS, Dijkstra J, Bergheanu SC, Putter H, Antoni ML, Atsma DE, Bootsma M, Zeppenfeld K, Jukema JW, et al. Stent malapposition after sirolimus-eluting and bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: Acute and 9-month intravascular ultrasound results of the MISSION! intervention study. JACC Cardiovasc Interv 2008; 1: 192-201.
    • (2008) JACC Cardiovasc Interv , vol.1 , pp. 192-201
    • Van Der Hoeven, B.L.1    Liem, S.S.2    Dijkstra, J.3    Bergheanu, S.C.4    Putter, H.5    Antoni, M.L.6    Atsma, D.E.7    Bootsma, M.8    Zeppenfeld, K.9    Jukema, J.W.10
  • 52
    • 68249122647 scopus 로고    scopus 로고
    • Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis
    • Cook S, Ladich E, Nakazawa G, Eshtehardi P, Neidhart M, Vogel R, Togni M, Wenaweser P, Billinger M, Seiler C, et al. Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis. Circulation 2009; 120: 391-399.
    • (2009) Circulation , vol.120 , pp. 391-399
    • Cook, S.1    Ladich, E.2    Nakazawa, G.3    Eshtehardi, P.4    Neidhart, M.5    Vogel, R.6    Togni, M.7    Wenaweser, P.8    Billinger, M.9    Seiler, C.10
  • 53
    • 33645462236 scopus 로고    scopus 로고
    • Zotarolimus-eluting stents reduce experimental coronary artery neointimal hyperplasia after 4 weeks
    • Garcia-Touchard A, Burke SE, Toner JL, Cromack K, Schwartz RS,. Zotarolimus-eluting stents reduce experimental coronary artery neointimal hyperplasia after 4 weeks. Eur Heart J 2006; 27: 988-993.
    • (2006) Eur Heart J , vol.27 , pp. 988-993
    • Garcia-Touchard, A.1    Burke, S.E.2    Toner, J.L.3    Cromack, K.4    Schwartz, R.S.5
  • 55
    • 35348913254 scopus 로고    scopus 로고
    • The significance of preclinical evaluation of sirolimus-, paclitaxel-, and zotarolimus-eluting stents
    • Nakazawa G, Finn AV, John MC, Kolodgie FD, Virmani R,. The significance of preclinical evaluation of sirolimus-, paclitaxel-, and zotarolimus-eluting stents. Am J Cardiol 2007; 100: 36M-44M.
    • (2007) Am J Cardiol , vol.100
    • Nakazawa, G.1    Finn, A.V.2    John, M.C.3    Kolodgie, F.D.4    Virmani, R.5
  • 58
    • 79959508607 scopus 로고    scopus 로고
    • Randomized comparison of everolimus- and paclitaxel-eluting stents. 2-year follow-up from the SPIRIT (clinical evaluation of the XIENCE v everolimus eluting coronary stent system) IV trial
    • Stone GW, Rizvi A, Sudhir K, Newman W, Applegate RJ, Cannon LA, Maddux JT, Cutlip DE, Simonton CA, Sood P, et al. Randomized comparison of everolimus- and paclitaxel-eluting stents. 2-year follow-up from the SPIRIT (clinical evaluation of the XIENCE V everolimus eluting coronary stent system) IV trial. J Am Coll Cardiol 2011; 58: 19-25.
    • (2011) J Am Coll Cardiol , vol.58 , pp. 19-25
    • Stone, G.W.1    Rizvi, A.2    Sudhir, K.3    Newman, W.4    Applegate, R.J.5    Cannon, L.A.6    Maddux, J.T.7    Cutlip, D.E.8    Simonton, C.A.9    Sood, P.10
  • 59
    • 73949122498 scopus 로고    scopus 로고
    • Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): A randomised trial
    • Kedhi E, Joesoef KS, McFadden E, Wassing J, van Mieghem C, Goedhart D, Smits PC,. Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): A randomised trial. Lancet 2010; 375: 201-209.
    • (2010) Lancet , vol.375 , pp. 201-209
    • Kedhi, E.1    Joesoef, K.S.2    McFadden, E.3    Wassing, J.4    Van Mieghem, C.5    Goedhart, D.6    Smits, P.C.7
  • 60
    • 79959502100 scopus 로고    scopus 로고
    • 2-year follow-up of a randomized controlled trial of everolimus- and paclitaxel-eluting stents for coronary revascularization in daily practice. COMPARE (comparison of the everolimus eluting XIENCE-V stent with the paclitaxel eluting TAXUS LIBERTE stent in all-comers: A randomized open label trial)
    • Smits PC, Kedhi E, Royaards KJ, Joesoef KS, Wassing J, Rademaker-Havinga TA, McFadden E,. 2-year follow-up of a randomized controlled trial of everolimus- and paclitaxel-eluting stents for coronary revascularization in daily practice. COMPARE (comparison of the everolimus eluting XIENCE-V stent with the paclitaxel eluting TAXUS LIBERTE stent in all-comers: A randomized open label trial). J Am Coll Cardiol 2011; 58: 11-18.
    • (2011) J Am Coll Cardiol , vol.58 , pp. 11-18
    • Smits, P.C.1    Kedhi, E.2    Royaards, K.J.3    Joesoef, K.S.4    Wassing, J.5    Rademaker-Havinga, T.A.6    McFadden, E.7
  • 61
    • 77958606991 scopus 로고    scopus 로고
    • Improved late clinical safety with zotarolimus-eluting stents compared with paclitaxel-eluting stents in patients with de novo coronary lesions: 3-year follow-up from the ENDEAVOR IV (randomized comparison of zotarolimus- and paclitaxel-eluting stents in patients with coronary artery disease) trial
    • Leon MB, Nikolsky E, Cutlip DE, Mauri L, Liberman H, Wilson H, Patterson J, Moses J, Kandzari DE,. Improved late clinical safety with zotarolimus-eluting stents compared with paclitaxel-eluting stents in patients with de novo coronary lesions: 3-year follow-up from the ENDEAVOR IV (randomized comparison of zotarolimus- and paclitaxel-eluting stents in patients with coronary artery disease) trial. JACC Cardiovasc Interv 2010; 3: 1043-1050.
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 1043-1050
    • Leon, M.B.1    Nikolsky, E.2    Cutlip, D.E.3    Mauri, L.4    Liberman, H.5    Wilson, H.6    Patterson, J.7    Moses, J.8    Kandzari, D.E.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.