메뉴 건너뛰기




Volumn 56, Issue 3, 2012, Pages 247-267

Combined PET/MR systems: An overview and comparison of currently available options

Author keywords

Diagnostic imaging; Magnetic resonance imaging; Positron emission tomography

Indexed keywords

FLUORODEOXYGLUCOSE F 18; GADOLINIUM; TETRAXETAN;

EID: 84865325053     PISSN: 18244785     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (41)

References (63)
  • 1
    • 0033870513 scopus 로고    scopus 로고
    • A combined PET/CT scanner for clinical oncology
    • Beyer T, Townsend DW, Brun T. A combined PET/CT scanner for clinical oncology. J Nucl Med 2000;41:1369-79.
    • (2000) J Nucl Med , vol.41 , pp. 1369-1379
    • Beyer, T.1    Townsend, D.W.2    Brun, T.3
  • 9
    • 34247199659 scopus 로고    scopus 로고
    • Simultaneous acquisition of multislice PET and MR images: Initial results with a MR-compatible PET scanner
    • Catana C, Wu Y, Judenhofer MS, Qi J, Pichler BJ, Cherry SR. Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner. J Nucl Med 2006;47,1968-76.
    • (2006) J Nucl Med , vol.47 , pp. 1968-1976
    • Catana, C.1    Wu, Y.2    Judenhofer, M.S.3    Qi, J.4    Pichler, B.J.5    Cherry, S.R.6
  • 11
    • 34548087667 scopus 로고    scopus 로고
    • PET/MR images, acquired with a compact MRI compatible PET detector in a 7 Tesla magnet
    • Judenhofer MS, Catana C, Swann BK, Siegel SB, Jung WI, Nutt RE et al. PET/MR images, acquired with a compact MRI compatible PET detector in a 7 Tesla magnet. Radiology 2007;244:807-14.
    • (2007) Radiology , vol.244 , pp. 807-814
    • Judenhofer, M.S.1    Catana, C.2    Swann, B.K.3    Siegel, S.B.4    Jung, W.I.5    Nutt, R.E.6
  • 13
    • 60549083251 scopus 로고    scopus 로고
    • Pre-clinical PET/MR: Technological advances and new perspectives in biomedical research
    • Wehrl HF, Judenhofer MS, Wiehr S, Pichler B. Pre-clinical PET/MR: technological advances and new perspectives in biomedical research. Eur J Nucl Med Mol Imaging 2009;36(Suppl 1):S56-S68.
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Wehrl, H.F.1    Judenhofer, M.S.2    Wiehr, S.3    Pichler, B.4
  • 17
    • 84865329129 scopus 로고    scopus 로고
    • Presentation of test measurements with a commercial small animal PET/MR imaging system
    • Nagy K, Nemeth G, Major P, Nyitrai Z, Máthé D, Gulyás B et al. Presentation of test measurements with a commercial small animal PET/MR imaging system. J Nucl Med 2011;52(Suppl 1):259.
    • (2011) J Nucl Med , vol.52 , Issue.SUPPL. 1 , pp. 259
    • Nagy, K.1    Nemeth, G.2    Major, P.3    Nyitrai, Z.4    Máthé, D.5    Gulyás, B.6
  • 18
    • 23844554858 scopus 로고    scopus 로고
    • Attenuation Correction for the NIH ATLAS Small Animal PET Scanner
    • Yao R, Seidel J, Liow JS, Green MV. Attenuation Correction for the NIH ATLAS Small Animal PET Scanner. IEEE Trans Nucl Sci 2005;52:664-8.
    • (2005) IEEE Trans Nucl Sci , vol.52 , pp. 664-668
    • Yao, R.1    Seidel, J.2    Liow, J.S.3    Green, M.V.4
  • 19
    • 77952097465 scopus 로고    scopus 로고
    • Evaluation of attenuation correction in the InveonTM preclinical PET scanner using two opposite, rotating 57Co point sources
    • Visser EP, van Dalen JA, Laverman P, Newport D, Corstens FHM, Oyen WJG et al. Evaluation of attenuation correction in the InveonTM preclinical PET scanner using two opposite, rotating 57Co point sources. Eur J Nucl Med Mol Imaging 2007;34(Supp. 2):S227.
    • (2007) Eur J Nucl Med Mol Imaging , vol.34 , Issue.SUPPL. 2
    • Visser, E.P.1    Van Dalen, J.A.2    Laverman, P.3    Newport, D.4    Corstens, F.H.M.5    Oyen, W.J.G.6
  • 21
    • 41549115846 scopus 로고    scopus 로고
    • A fusion PET-MRI system with a highresolution research tomograph-PET and ultra-high field 7.0T-MRI for the molecular-genetic imaging of the brain
    • Cho ZH, Son YD, Kim HK, Kim KN, Oh SH, Han JY. A fusion PET-MRI system with a highresolution research tomograph-PET and ultra-high field 7.0T-MRI for the molecular-genetic imaging of the brain. Proteomics. 2008;8:1302-23.
    • (2008) Proteomics , vol.8 , pp. 1302-1323
    • Cho, Z.H.1    Son, Y.D.2    Kim, H.K.3    Kim, K.N.4    Oh, S.H.5    Han, J.Y.6
  • 22
    • 79851486602 scopus 로고    scopus 로고
    • Horizontal Versus Longitudinal Axis of the Hippocampus: Metabolic Differentiation as Measured with High-Resolution PET/MRI
    • Jan 13. (Epub ahead of print)
    • Cho ZH, Son YD, Kim HK, Kim ST, Lee SY, Chi JG, et al. Horizontal Versus Longitudinal Axis of the Hippocampus: Metabolic Differentiation as Measured with High-Resolution PET/MRI. J Nucl Med 2011; Jan 13. (Epub ahead of print)
    • (2011) J Nucl Med
    • Cho, Z.H.1    Son, Y.D.2    Kim, H.K.3    Kim, S.T.4    Lee, S.Y.5    Chi, J.G.6
  • 23
    • 83055180743 scopus 로고    scopus 로고
    • Glucose metabolism of the midline nuclei raphe in the brainstem observed by PET-MRI fusion imaging
    • Son YD, Cho ZH, Kim HK, Choi EJ, Lee SY, Chi JG et al. Glucose metabolism of the midline nuclei raphe in the brainstem observed by PET-MRI fusion imaging. NeuroImage 2012;59:1094-7.
    • (2012) NeuroImage , vol.59 , pp. 1094-1097
    • Son, Y.D.1    Cho, Z.H.2    Kim, H.K.3    Choi, E.J.4    Lee, S.Y.5    Chi, J.G.6
  • 26
    • 39049097904 scopus 로고    scopus 로고
    • BrainPET: First human tomograph for simultaneous (functional) PET and MR imaging
    • Schmand M, Burbar Z, Corbeil J, Zhang N, Michel C, Byars L et al. BrainPET: First human tomograph for simultaneous (functional) PET and MR imaging. J Nucl Med 2007;48(Suppl 2), 310P.
    • (2007) J Nucl Med , vol.48 , Issue.SUPPL. 2
    • Schmand, M.1    Burbar, Z.2    Corbeil, J.3    Zhang, N.4    Michel, C.5    Byars, L.6
  • 28
    • 80053611395 scopus 로고    scopus 로고
    • An outlook on future design of hybrid PET/MRI systems
    • Zaidi H and Del Guerra A. An outlook on future design of hybrid PET/MRI systems. Med Phys 2011;38:5667-89.
    • (2011) Med Phys , vol.38 , pp. 5667-5689
    • Zaidi, H.1    Del Guerra, A.2
  • 31
    • 34247203132 scopus 로고    scopus 로고
    • Performance evaluation of the ECAT HRRT: An LSO-LYSO double layer high resolution, high sensitivity scanner
    • de Jong HW, van Velden FH, Kloet RW, Buijs FL, Boellaard R, Lammertsma AA. Performance evaluation of the ECAT HRRT: an LSO-LYSO double layer high resolution, high sensitivity scanner. Phys Med Biol 2007;52:1505-15.
    • (2007) Phys Med Biol , vol.52 , pp. 1505-1515
    • De Jong, H.W.1    Van Velden, F.H.2    Kloet, R.W.3    Buijs, F.L.4    Boellaard, R.5    Lammertsma, A.A.6
  • 34
    • 15044344615 scopus 로고    scopus 로고
    • O-(2-[18F]fluoroethyl)-L-tyrosine PET combined with magnetic resonance imaging improves the diagnostic assessment of cerebral gliomas
    • Pauleit D, Floeth F, Hamacher K, Riemenschneider MJ, Reifen-berger G, Müller HW et al. O-(2-[18F]fluoroethyl)-L-tyrosine PET combined with magnetic resonance imaging improves the diagnostic assessment of cerebral gliomas. Brain 2005;128:678-87.
    • (2005) Brain , vol.128 , pp. 678-687
    • Pauleit, D.1    Floeth, F.2    Hamacher, K.3    Riemenschneider, M.J.4    Reifenberger, G.5    Müller, H.W.6
  • 36
    • 77956216707 scopus 로고    scopus 로고
    • Hybrid PET/MRI of intracranial masses: Initial experiences and comparison to PET/CT
    • Boss A, Bisdas S, Kolb A, Hofmann M, Ernemann U, Claussen CD et al. Hybrid PET/MRI of intracranial masses: initial experiences and comparison to PET/CT. J Nucl Med 2010;51:1198-205.
    • (2010) J Nucl Med , vol.51 , pp. 1198-1205
    • Boss, A.1    Bisdas, S.2    Kolb, A.3    Hofmann, M.4    Ernemann, U.5    Claussen, C.D.6
  • 39
    • 84878284014 scopus 로고    scopus 로고
    • Simultaneous PET/MRI for the evaluation of hemato-oncological diseases with lower extremity manifestations
    • Sauter A, Horger M, Boss A, Kolb A, Mantlik F, Kanz L et al. Simultaneous PET/MRI for the evaluation of hemato-oncological diseases with lower extremity manifestations. J Nucl Med 2010;51(Suppl 2):170P.
    • (2010) J Nucl Med , vol.51 , Issue.SUPPL. 2
    • Sauter, A.1    Horger, M.2    Boss, A.3    Kolb, A.4    Mantlik, F.5    Kanz, L.6
  • 40
    • 34247230296 scopus 로고    scopus 로고
    • Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities
    • Surti S, Kuhn A, Werner ME, Perkins AE, Kolthammer J, Karp JS. Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities. J Nucl Med. 2007;48:471-80.
    • (2007) J Nucl Med , vol.48 , pp. 471-480
    • Surti, S.1    Kuhn, A.2    Werner, M.E.3    Perkins, A.E.4    Kolthammer, J.5    Karp, J.S.6
  • 41
    • 79955416013 scopus 로고    scopus 로고
    • Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system
    • Zaidi H, Ojha N, Morich M, Griesmer J, Hu Z, Maniawski P et al. Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system. Phys Med Biol 2011;56:3091-106.
    • (2011) Phys Med Biol , vol.56 , pp. 3091-3106
    • Zaidi, H.1    Ojha, N.2    Morich, M.3    Griesmer, J.4    Hu, Z.5    Maniawski, P.6
  • 42
    • 83755161889 scopus 로고    scopus 로고
    • Performance measurements of the Siemens mMR integrated whole-Body PET/MR scanner
    • Nov 14. [Epub ahead of print]
    • Delso G, Fürst S, Jakoby B, Ladebecke R, Ganter C, Nekolla SG et al. Performance measurements of the Siemens mMR integrated whole-Body PET/MR scanner. J Nucl Med 2011 Nov 14. [Epub ahead of print]
    • (2011) J Nucl Med
    • Delso, G.1    Fürst, S.2    Jakoby, B.3    Ladebecke, R.4    Ganter, C.5    Nekolla, S.G.6
  • 43
    • 0003710941 scopus 로고    scopus 로고
    • NEMA. Standards Publication NU 2-2007. Rosslyn, VA: National Electrical Manufacturers Association
    • NEMA. Standards Publication NU 2-2007. Performance Measurements of Positron Emission Tomographs. Rosslyn, VA: National Electrical Manufacturers Association; 2007.
    • (2007) Performance Measurements of Positron Emission Tomographs
  • 44
    • 14244251257 scopus 로고    scopus 로고
    • Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging
    • Montandon ML, Zaidi H. Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging. Neuroimage 2005;25:278-86.
    • (2005) Neuroimage , vol.25 , pp. 278-286
    • Montandon, M.L.1    Zaidi, H.2
  • 45
    • 67649185917 scopus 로고    scopus 로고
    • Template based attenuation correction for PET in MR-PET scanners
    • Rota Kops E, Herzog H. Template based attenuation correction for PET in MR-PET scanners. IEEE NSS-MIC conf record 2008:3786-9.
    • (2008) IEEE NSS-MIC Conf Record , pp. 3786-3789
    • Rota Kops, E.1    Herzog, H.2
  • 46
    • 0032970425 scopus 로고    scopus 로고
    • Nonlinear spatial normalization using basis functions
    • Ashburner J, Friston KJ. Nonlinear spatial normalization using basis functions. Hum Brain Mapp 1999;70:254-66.
    • (1999) Hum Brain Mapp , vol.70 , pp. 254-266
    • Ashburner, J.1    Friston, K.J.2
  • 47
    • 57349155316 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI: A novel approach combining pattern recognition and atlas registration
    • Hofmann M, Steinke F, Scheel V, Charpiat G, Farquhar J, Aschoff P et al. MRI-based attenuation correction for PET/MRI: A novel approach combining pattern recognition and atlas registration. J Nucl Med. 2008;49:1875-83.
    • (2008) J Nucl Med , vol.49 , pp. 1875-1883
    • Hofmann, M.1    Steinke, F.2    Scheel, V.3    Charpiat, G.4    Farquhar, J.5    Aschoff, P.6
  • 49
    • 77957038794 scopus 로고    scopus 로고
    • Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype
    • Catana C, van der Kouwe A, Benner T, Michel CJ, Hamm M, Fenchel M et al. Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype. J Nucl Med 2010;51:1431-8.
    • (2010) J Nucl Med , vol.51 , pp. 1431-1438
    • Catana, C.1    Van Der Kouwe, A.2    Benner, T.3    Michel, C.J.4    Hamm, M.5    Fenchel, M.6
  • 50
    • 63849338624 scopus 로고    scopus 로고
    • Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: Evaluation with PET/CT data
    • Martinez-Möller A, Souvatzoglou M, Delso G, Bundschuh RA, Chefd'hotel C, Ziegler SI et al. Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J Nucl Med 2009;50:520-6.
    • (2009) J Nucl Med , vol.50 , pp. 520-526
    • Martinez-Möller, A.1    Souvatzoglou, M.2    Delso, G.3    Bundschuh, R.A.4    Chefd'hotel, C.5    Ziegler, S.I.6
  • 51
    • 84861998933 scopus 로고    scopus 로고
    • Integrated simultaneous whole-body MR/PET: First comparison between MR/PET and PET/CT in patients
    • Drzezga A, Souvatzoglou M, Beer A, Ziegler S, Fürst S, Nekolla S et al. Integrated simultaneous whole-body MR/PET: First comparison between MR/PET and PET/CT in patients. J Nucl Med, 2011;52(Suppl 1):79P.
    • (2011) J Nucl Med , vol.52 , Issue.SUPPL. 1
    • Drzezga, A.1    Souvatzoglou, M.2    Beer, A.3    Ziegler, S.4    Fürst, S.5    Nekolla, S.6
  • 52
    • 80052644918 scopus 로고    scopus 로고
    • MRI-based attenuation correction for whole-body PET/MRI: Quantitative evaluation of segmentation- and atlas-based methods
    • Hofmann M, Bezrukov I, Mantlik F, Aschoff P, Steinke F, Beyer T et al. MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods. J Nucl Med 2011;52:1392-9.
    • (2011) J Nucl Med , vol.52 , pp. 1392-1399
    • Hofmann, M.1    Bezrukov, I.2    Mantlik, F.3    Aschoff, P.4    Steinke, F.5    Beyer, T.6
  • 55
    • 79959543762 scopus 로고    scopus 로고
    • The effect of MR surface coils on PET quantification in whole-body PET/MR: Results from a pseudo-PET/MR phantom study
    • Tellmann L, Quick HH, Bockisch A, Herzog H, Beyer T. The effect of MR surface coils on PET quantification in whole-body PET/MR: results from a pseudo-PET/MR phantom study. Med Phys 2011;38:2795-805.
    • (2011) Med Phys , vol.38 , pp. 2795-2805
    • Tellmann, L.1    Quick, H.H.2    Bockisch, A.3    Herzog, H.4    Beyer, T.5
  • 57
    • 79551523276 scopus 로고    scopus 로고
    • Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
    • Schulz V, Torres-Espallardo I, Renisch S, Hu Z, Ojha N, Börne P et al. Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data. EJNMMI 2010;38:138-52.
    • (2010) EJNMMI , vol.38 , pp. 138-152
    • Schulz, V.1    Torres-Espallardo, I.2    Renisch, S.3    Hu, Z.4    Ojha, N.5    Börne, P.6
  • 59
    • 80855128883 scopus 로고    scopus 로고
    • The effect of errors in segmented attenuation maps on PET quantification
    • Keereman V, Van Holen R, Mollet P, Vandenberghe S. The effect of errors in segmented attenuation maps on PET quantification,. Med Phys 2011;38:6010-9.
    • (2011) Med Phys , vol.38 , pp. 6010-6019
    • Keereman, V.1    Van Holen, R.2    Mollet, P.3    Vandenberghe, S.4
  • 60
  • 61
    • 33646456751 scopus 로고    scopus 로고
    • Concepts of registration and correction of head motion in positron emission tomography
    • Tellmann L, Fulton R, Pietrzyk U, Nickel I, Stangier I, Winz O et al. Concepts of registration and correction of head motion in positron emission tomography. Z Med Phys 2006;16:67-74.
    • (2006) Z Med Phys , vol.16 , pp. 67-74
    • Tellmann, L.1    Fulton, R.2    Pietrzyk, U.3    Nickel, I.4    Stangier, I.5    Winz, O.6
  • 62
    • 79851475594 scopus 로고    scopus 로고
    • MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner
    • Catana C, Benner T, van der Kouwe A, Byars L, Hamm M, Chonde DB et al. MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner. J Nucl Med 2011;52:154-61.
    • (2011) J Nucl Med , vol.52 , pp. 154-161
    • Catana, C.1    Benner, T.2    Van Der Kouwe, A.3    Byars, L.4    Hamm, M.5    Chonde, D.B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.