메뉴 건너뛰기




Volumn 49, Issue 1, 2013, Pages

Response characteristics of a new-style carbon nanotubes (CNTs) gas sensor

Author keywords

Carbon nanotubes; Gas sensor; Response characteristics; SF6 decomposition

Indexed keywords


EID: 84873965702     PISSN: 10011609     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (19)
  • 1
    • 14344256279 scopus 로고    scopus 로고
    • Present status and prospect of research of online partial discharge monitoring system in GIS
    • XIAO Yan, YU Wei-yong. Present status and prospect of research of online partial discharge monitoring system in GIS[J]. High Voltage Engineering, 2005, 31(1):47-49.
    • (2005) High Voltage Engineering , vol.31 , Issue.1 , pp. 47-49
    • Xiao, Y.1    Yu, W.-Y.2
  • 2
    • 27144550858 scopus 로고    scopus 로고
    • Introduction and applications of gas insulated substation (GIS)
    • BOLIN P, KOCH H. Introduction and applications of gas insulated substation (GIS)[J]. Power Engineering Society General Meeting, 2005(1):920-926.
    • (2005) Power Engineering Society General Meeting , Issue.1 , pp. 920-926
    • Bolin, P.1    Koch, H.2
  • 5
    • 0034240471 scopus 로고    scopus 로고
    • Frequency response characteristic of the UHF sensors for partial discharge detection in GIS
    • WANG Jian-sheng, QIU Yu-chang, WU Xiang-hua, et al. Frequency response characteristic of the UHF sensors for partial discharge detection in GIS[J]. Proceeding of the CSEE, 2000, 20(8):42-45.
    • (2000) Proceeding of the CSEE , vol.20 , Issue.8 , pp. 42-45
    • Wang, J.-S.1    Qiu, Y.-C.2    Wu, X.-H.3
  • 8
    • 51149106993 scopus 로고    scopus 로고
    • Comparative research on current pulse method and UHF measurements of partial discharge in mineral oil
    • ZHAO Xiao-hui, YANG Jing-gang, LU Xiu-li, et al. Comparative research on current pulse method and UHF measurements of partial discharge in mineral oil [J]. High Voltage Engineering, 2008, 34(7): 1401-1404.
    • (2008) High Voltage Engineering , vol.34 , Issue.7 , pp. 1401-1404
    • Zhao, X.-H.1    Yang, J.-G.2    Lu, X.-L.3
  • 9
    • 15744373122 scopus 로고    scopus 로고
    • The actuality and perspective of partial discharge detection techniques
    • GUO Jun, WU Guang-ning, ZHANG Xue-qin, et al. The actuality and perspective of partial discharge detection techniques[J]. Transactions of China Electrotechnical Society, 2005, 20(2): 29-35.
    • (2005) Transactions of China Electrotechnical Society , vol.20 , Issue.2 , pp. 29-35
    • Guo, J.1    Wu, G.-N.2    Zhang, X.-Q.3
  • 10
    • 0028756142 scopus 로고
    • 6 in a negative glow corona discharge
    • 6 in a negative glow corona discharge[J]. Physical Scripta, 1994, 23(2):9-29.
    • (1994) Physical Scripta , vol.23 , Issue.2 , pp. 9-29
    • Van, R.J.1    Herronl, J.T.2
  • 14
    • 14744289658 scopus 로고    scopus 로고
    • 6 gas using a carbon nanotube-based gas sensor
    • 6 gas using a carbon nanotube-based gas sensor[J]. Sens. Actuators B, 2005, 105(2):164-169.
    • (2005) Sens. Actuators B , vol.105 , Issue.2 , pp. 164-169
    • Suehiro, J.1    Zhou, G.2    Hara, M.3
  • 17
    • 84873942835 scopus 로고
    • 6 corona discharges
    • USA: IEEE
    • 6 corona discharges[C]//Tennessee. USA: IEEE, 1991:20-24.
    • (1991) Tennessee , pp. 20-24
    • Sauers, I.1