Volumn 60, Issue 1, 2013, Pages 82-86

Construction and evaluation of a prototype high resolution, silicon photomultiplier-based, tandem positron emission tomography system

Author keywords

High resolution; nuclear medicine imaging; PET instrumentation

Indexed keywords

AXIAL RESOLUTIONS; CLINICAL APPLICATION; DETECTION SENSITIVITY; FIELD OF VIEWS; HIGH RESOLUTION; HIGH RESOLUTION IMAGE; MAXIMUM-LIKELIHOOD EXPECTATION MAXIMIZATIONS; MEASUREMENTS OF; NUCLEAR MEDICINE IMAGING; PET IMAGES; PET IMAGING; PET SCANNER; PROTOTYPE SYSTEM; SCINTILLATOR ARRAYS; SILICON PHOTOMULTIPLIER; SMALL DETECTORS; SMALL REGION; SPATIAL RESOLUTION; SPECIFIC TASKS; TRANSAXIAL;

EID: 84873722150     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2013.2237788     Document Type: Article
Times cited : (11)

References (12)
  • 1
    • 80053580317 scopus 로고    scopus 로고
    • NEMA NU-04-based performance characteristics of the LabPET-8 small animal PET scanner
    • R. Prasad, O. O. Ratib, and H. Zaidi, "NEMA NU-04-based performance characteristics of the LabPET-8 small animal PET scanner," Phys. Med. Biol., vol. 56, pp. 6649-6664, 2011.
    • (2011) Phys. Med. Biol. , vol.56 , pp. 6649-6664
    • Prasad, R.1    Ratib, O.O.2    Zaidi, H.3
  • 2
    • 79251604402 scopus 로고    scopus 로고
    • Characterization and optimization of image quality as a function of reconstruction algorithms and parameter settings in a siemens inveon small-animal PET scanner using the NEMA NU 4-2008 standards
    • E. P. Visser, J. A. Disselhorst, M. G. J. T. B. van Lier, P. Laverman, G.M. de Jong, E. W. J. Oyen, and O. C. Boerman, "Characterization and optimization of image quality as a function of reconstruction algorithms and parameter settings in a siemens inveon small-animal PET scanner using the NEMA NU 4-2008 standards," Nucl. Instrum. Meth. Phys. Res. Sect. A, vol. 629, pp. 357-367, 2011.
    • (2011) Nucl. Instrum. Meth. Phys. Res. Sect. A , vol.629 , pp. 357-367
    • Visser, E.P.1    Disselhorst, J.A.2    Van Lier, M.G.J.T.B.3    Laverman, P.4    De Jong, G.M.5    Oyen, E.W.J.6    Boerman, O.C.7
  • 3
    • 79951682532 scopus 로고    scopus 로고
    • NEMA NU 4-2008 performance measurements of two commercial small-animal PET scanners: ClearPET and rPET-1
    • Feb.
    • M. Cañadas, M. Embid, E. Lage, M. Desco, J. J. Vaquero, and J. M. Pe'rez, "NEMA NU 4-2008 performance measurements of two commercial small-animal PET scanners: ClearPET and rPET-1," IEEE Trans. Nucl. Sci., vol. 58, no. 1, pp. 58-65, Feb. 2011.
    • (2011) IEEE Trans. Nucl. Sci. , vol.58 , Issue.1 , pp. 58-65
    • Cañadas, M.1    Embid, M.2    Lage, E.3    Desco, M.4    Vaquero, J.J.5    Pe'Rez, J.M.6
  • 5
    • 23844535850 scopus 로고    scopus 로고
    • High resolution insert for clinical whole body PET scanners: Design and optimization
    • M10-72, 2004 IEEE Nuclear Science Symposium Conference Record
    • M. Janecek, H. Wu, and Y.-C. Tai, "High resolution insert for clinical whole body PET scanners: Design and optimization," in Proc. IEEE Nucl. Sci. Symp. Conf. Rec., 2004, vol. 6, pp. 3849-3852. (Pubitemid 41147780)
    • (2004) IEEE Nuclear Science Symposium Conference Record , vol.6 , pp. 3849-3852
    • Janecek, M.1    Wu, H.2    Tai, Y.-C.3
  • 8
    • 80052053090 scopus 로고    scopus 로고
    • Experimental assessment of resolution improvement of a zoom-in PET
    • J. Qi, Y. Yang, J. Zhou, Y. Wu, and S. R. Cherry, "Experimental assessment of resolution improvement of a zoom-in PET," Phys. Med. Biol., vol. 56, pp. N165-N174, 2011.
    • (2011) Phys. Med. Biol. , vol.56
    • Qi, J.1    Yang, Y.2    Zhou, J.3    Wu, Y.4    Cherry, S.R.5
  • 10
    • 11844304101 scopus 로고    scopus 로고
    • Readout electronics for multianode photomultiplier tubes with pad matrix anode layout
    • M6-95, 2003 IEEE Nuclear Science Symposium Conference Record - Nuclear Science Symposium, Medical Imaging Conference
    • V. Popov, S. Majewski, and A. G.Weisenberger, "Readout electronics for multianode photomultiplier tubes with pad matrix anode layout," in Proc. IEEE Nucl. Sci. Sympos. Conf. Rec., 2004, vol. 3, pp. 2156-2159. (Pubitemid 40089018)
    • (2003) IEEE Nuclear Science Symposium Conference Record , vol.3 , pp. 2156-2159
    • Popov, V.1    Majewski, S.2    Weisenberger, A.G.3
  • 11
    • 84873729745 scopus 로고    scopus 로고
    • FDG-PET standardized uptake in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection
    • C. D. Ramos, Y. E. Erdi, M. Goene, E. Reidel, H. W. Yeung, H. A. MacApinlac, R. Chisin, and S. M. Larsen, "FDG-PET standardized uptake in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection," Eur. J. Nucl. Med., vol. 39, pp. 1002-1006, 2001.
    • (2001) Eur. J. Nucl. Med. , vol.39 , pp. 1002-1006
    • Ramos, C.D.1    Erdi, Y.E.2    Goene, M.3    Reidel, E.4    Yeung, H.W.5    MacApinlac, H.A.6    Chisin, R.7    Larsen, S.M.8
  • 12


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.