-
1
-
-
33645562681
-
Ct dose reduction and dose management tools: Overview of available options
-
10.1148/rg.262055138
-
C. McCollough, M. Bruesewitz, and J. Kofler, " Ct dose reduction and dose management tools: Overview of available options.," Radiographics 26 (2), 503-512 (2006). 10.1148/rg.262055138
-
(2006)
Radiographics
, vol.26
, Issue.2
, pp. 503-512
-
-
McCollough, C.1
Bruesewitz, M.2
Kofler, J.3
-
2
-
-
0032742081
-
Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
-
10.1118/1.598738
-
W. Kalender, H. Wolf, and C. Suess, " Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements.," Med. Phys. 26, 2248-2253 (1999). 10.1118/1.598738
-
(1999)
Med. Phys.
, vol.26
, pp. 2248-2253
-
-
Kalender, W.1
Wolf, H.2
Suess, C.3
-
3
-
-
34347396603
-
Compensators for dose and scatter management in cone-beam computed tomography
-
10.1118/1.2740466
-
S. Graham, D. Moseley, J. Siewerdsen, and D. Jaffray, " Compensators for dose and scatter management in cone-beam computed tomography.," Med. Phys. 34, 2691-2703 (2007). 10.1118/1.2740466
-
(2007)
Med. Phys.
, vol.34
, pp. 2691-2703
-
-
Graham, S.1
Moseley, D.2
Siewerdsen, J.3
Jaffray, D.4
-
4
-
-
34347401255
-
The influence of patient centering on ct dose and image noise
-
10.1118/1.2748113
-
T. Toth, Z. Ge, and M. Daly, " The influence of patient centering on ct dose and image noise.," Med. Phys. 34, 3093-3101 (2007). 10.1118/1.2748113
-
(2007)
Med. Phys.
, vol.34
, pp. 3093-3101
-
-
Toth, T.1
Ge, Z.2
Daly, M.3
-
5
-
-
77749291751
-
Computer-assisted scan protocol and reconstruction (caspar) reduction of image noise and patient dose
-
10.1109/TMI.2009.2034515
-
J. Sperl, D. Beque, B. Claus, B. De Man, B. Senzig, and M. Brokate, " Computer-assisted scan protocol and reconstruction (caspar) reduction of image noise and patient dose.," IEEE Trans. Med. Imaging 29 (3), 724-732 (2010). 10.1109/TMI.2009.2034515
-
(2010)
IEEE Trans. Med. Imaging
, vol.29
, Issue.3
, pp. 724-732
-
-
Sperl, J.1
Beque, D.2
Claus, B.3
De Man, B.4
Senzig, B.5
Brokate, M.6
-
6
-
-
79960916886
-
Fluence field optimization for noise and dose objectives in CT
-
10.1118/1.3574885
-
S. Bartolac, S. Graham, J. Siewerdsen, and D. Jaffray, " Fluence field optimization for noise and dose objectives in CT.," Med. Phys. 38, S2-S17 (2011). 10.1118/1.3574885
-
(2011)
Med. Phys.
, vol.38
-
-
Bartolac, S.1
Graham, S.2
Siewerdsen, J.3
Jaffray, D.4
-
7
-
-
84860356047
-
Compensator approaches for intensity modulated computed tomography
-
in, Salt Lake City (Utah center for advanced imaging research, Salt Lake City), Vol. (1)
-
S. Bartolac, S. Graham, J. Siewerdsen, and D. Jaffray, " Compensator approaches for intensity modulated computed tomography.," in Proceedings of the International Conference on Image Formation in X-ray Computed Tomography, Salt Lake City, (Utah center for advanced imaging research, Salt Lake City, 2010), Vol. 1 (1), p. 101.
-
(2010)
Proceedings of the International Conference on Image Formation in X-ray Computed Tomography
, vol.1
, pp. 101
-
-
Bartolac, S.1
Graham, S.2
Siewerdsen, J.3
Jaffray, D.4
-
8
-
-
84873595031
-
Fluence field modulated computed tomography
-
in, Salt Lake City (Utah center for advanced imaging research, Salt Lake City), Vol. (2)
-
S. Bartolac and D. Jaffray, " Fluence field modulated computed tomography.," in Proceedings of the International Conference on Image Formation in X-ray Computed Tomography, Salt Lake City, (Utah center for advanced imaging research, Salt Lake City, 2012), Vol. 2 (2), pp. 119-122.
-
(2012)
Proceedings of the International Conference on Image Formation in X-ray Computed Tomography
, vol.2
, pp. 119-122
-
-
Bartolac, S.1
Jaffray, D.2
-
9
-
-
84858685921
-
CT dose reduction using dynamic collimation
-
in, Valencia (IEEE, New York, New York)
-
D. Heuscher and F. Noo, " CT dose reduction using dynamic collimation.," in Proceedings of the 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Valencia, (IEEE, New York, New York, 2011), pp. 3470-3473.
-
(2011)
Proceedings of the 2011 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
, pp. 3470-3473
-
-
Heuscher, D.1
Noo, F.2
-
10
-
-
84873573140
-
CT dose reduction using dynamic collimation
-
in, Salt Lake City (Utah center for advanced imaging research, Salt Lake City)
-
D. J. Heuscher and F. Noo, " CT dose reduction using dynamic collimation.," in Proceedings of the Second International Conference on Image Formation in X-Ray Computed Tomography, Salt Lake City, (Utah center for advanced imaging research, Salt Lake City, 2012), pp. 115-118.
-
(2012)
Proceedings of the Second International Conference on Image Formation in X-Ray Computed Tomography
, pp. 115-118
-
-
Heuscher, D.J.1
Noo, F.2
-
11
-
-
58149115069
-
The influence of bowtie filtration on cone-beam CT image quality
-
10.1118/1.3017470
-
N. Mail, D. Moseley, J. Siewerdsen, and D. Jaffray, " The influence of bowtie filtration on cone-beam CT image quality.," Med. Phys. 36, 22-32 (2009). 10.1118/1.3017470
-
(2009)
Med. Phys.
, vol.36
, pp. 22-32
-
-
Mail, N.1
Moseley, D.2
Siewerdsen, J.3
Jaffray, D.4
-
12
-
-
0003498152
-
-
(Publicis, Erlangen), Vol.
-
W. Kalender, Computed Tomography: Fundamentals, System Technology, Image Quality, Applications (Publicis, Erlangen, 2000), Vol. 1, p. 220.
-
(2000)
Computed Tomography: Fundamentals, System Technology, Image Quality, Applications
, vol.1
, pp. 220
-
-
Kalender, W.1
-
13
-
-
84860377570
-
Practical considerations for intensity modulated CT
-
10.1117/12.911355
-
T. Szczykutowicz and C. Mistretta, " Practical considerations for intensity modulated CT.," Proc. SPIE 8313, 83134E-1-83134E-11 (2012). 10.1117/12.911355
-
(2012)
Proc. SPIE
, vol.8313
-
-
Szczykutowicz, T.1
Mistretta, C.2
-
14
-
-
44249109961
-
Three-dimensional c-arm cone-beam CT: Applications in the interventional suite
-
10.1016/j.jvir.2008.02.018
-
M. Wallace, M. Kuo, C. Glaiberman, C. Binkert, R. Orth, and G. Soulez, " Three-dimensional c-arm cone-beam CT: Applications in the interventional suite.," J. Vasc. Interv. Radiol. 19 (6), 799-813 (2008). 10.1016/j.jvir.2008.02.018
-
(2008)
J. Vasc. Interv. Radiol.
, vol.19
, Issue.6
, pp. 799-813
-
-
Wallace, M.1
Kuo, M.2
Glaiberman, C.3
Binkert, C.4
Orth, R.5
Soulez, G.6
-
15
-
-
77953068729
-
C-arm flat detector computed tomography: The technique and its applications in interventional neuro-radiology
-
10.1007/s00234-009-0609-5
-
M. Kamran, S. Nagaraja, and J. Byrne, " C-arm flat detector computed tomography: The technique and its applications in interventional neuro-radiology.," Neuroradiology 52 (4), 319-327 (2010). 10.1007/s00234-009-0609-5
-
(2010)
Neuroradiology
, vol.52
, Issue.4
, pp. 319-327
-
-
Kamran, M.1
Nagaraja, S.2
Byrne, J.3
-
16
-
-
0032744531
-
Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies
-
10.1118/1.598779
-
M. Gies, W. Kalender, H. Wolf, C. Suess, and M. Madsen, " Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies.," Med. Phys. 26, 2235-2247 (1999). 10.1118/1.598779
-
(1999)
Med. Phys.
, vol.26
, pp. 2235-2247
-
-
Gies, M.1
Kalender, W.2
Wolf, H.3
Suess, C.4
Madsen, M.5
-
17
-
-
85027231849
-
Design of a dynamic beam attenuation system for computed tomography: Part II. Performance study and initial results
-
(submitted).
-
T. Szczykutowicz and C. Mistretta, " Design of a dynamic beam attenuation system for computed tomography: Part II. Performance study and initial results.," Med. Phys. (submitted).
-
Med. Phys.
-
-
Szczykutowicz, T.1
Mistretta, C.2
-
18
-
-
9244249165
-
Specktr: A computational tool for x-ray spectral analysis and imaging system optimization
-
10.1118/1.1758350
-
J. Siewerdsen, A. Waese, D. Moseley, S. Richard, and D. Jaffray, " Specktr: A computational tool for x-ray spectral analysis and imaging system optimization.," Med. Phys. 31, 3057-3067 (2004). 10.1118/1.1758350
-
(2004)
Med. Phys.
, vol.31
, pp. 3057-3067
-
-
Siewerdsen, J.1
Waese, A.2
Moseley, D.3
Richard, S.4
Jaffray, D.5
-
19
-
-
0030657556
-
An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 KV
-
10.1118/1.597953
-
J. M. Boone and J. A. Seibert, " An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 KV.," Med. Phys. 24, 1661-1670 (1997). 10.1118/1.597953
-
(1997)
Med. Phys.
, vol.24
, pp. 1661-1670
-
-
Boone, J.M.1
Seibert, J.A.2
-
20
-
-
0003523755
-
-
NIST Technical Report (Ionizing Radiation Division, National Institute of Standards and Technology, Gaithersburg, MD).
-
J. Hubbell and S. Seltzer, " Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements z = 1 to 92 and 48 additional substances of dosimetric interest.," NIST Technical Report (Ionizing Radiation Division, National Institute of Standards and Technology, Gaithersburg, MD, 1995).
-
(1995)
Tables of X-ray Mass Attenuation Coefficients and Mass Energy-absorption Coefficients 1 KeV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest
-
-
Hubbell, J.1
Seltzer, S.2
-
21
-
-
0004045887
-
-
(Brooks, Cole Publisher Company, Three Lakes Wisconsin).
-
R. Burden and J. Faires, Numerical Analysis (Brooks, Cole Publisher Company, Three Lakes Wisconsin, 1997).
-
(1997)
Numerical Analysis
-
-
Burden, R.1
Faires, J.2
-
22
-
-
0003682469
-
-
International Commission in Radiation Units and Measurements, "," ICRU Report No. 44 (ICRU Publications, Bethesda, MD).
-
International Commission in Radiation Units and Measurements, " Tissue substitutes in radiation dosimetry and measurement.," ICRU Report No. 44 (ICRU Publications, Bethesda, MD, 1989).
-
(1989)
Tissue Substitutes in Radiation Dosimetry and Measurement
-
-
-
23
-
-
70350729133
-
Accelerating monte carlo simulations of photon transport in a voxelized geometry using a massively parallel graphics processing unit
-
10.1118/1.3231824
-
A. Badal and A. Badano, " Accelerating monte carlo simulations of photon transport in a voxelized geometry using a massively parallel graphics processing unit.," Med. Phys. 36, 4878-4880 (2009). 10.1118/1.3231824
-
(2009)
Med. Phys.
, vol.36
, pp. 4878-4880
-
-
Badal, A.1
Badano, A.2
-
24
-
-
0001285808
-
An efficient method for generating discrete random variables with general distributions
-
10.1145/355744.355749
-
A. J. Walker, " An efficient method for generating discrete random variables with general distributions.," ACM Trans. Math. Softw. 3, 253-256 (1977). 10.1145/355744.355749
-
(1977)
ACM Trans. Math. Softw.
, vol.3
, pp. 253-256
-
-
Walker, A.J.1
-
25
-
-
2542455683
-
Accelerated simulation of cone beam x-ray scatter projections
-
10.1109/TMI.2004.825600
-
A. Colijn and F. Beekman, " Accelerated simulation of cone beam x-ray scatter projections.," IEEE Trans. Med. Imaging 23 (5), 584-590 (2004). 10.1109/TMI.2004.825600
-
(2004)
IEEE Trans. Med. Imaging
, vol.23
, Issue.5
, pp. 584-590
-
-
Colijn, A.1
Beekman, F.2
-
26
-
-
33645286933
-
Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT
-
10.1109/TMI.2006.872328
-
W. Zbijewski and F. Beekman, " Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT.," IEEE Trans. Med. Imaging 25 (7), 817-827 (2006). 10.1109/TMI.2006.872328
-
(2006)
IEEE Trans. Med. Imaging
, vol.25
, Issue.7
, pp. 817-827
-
-
Zbijewski, W.1
Beekman, F.2
-
27
-
-
56849113227
-
Algorithm for x-ray scatter, beam-hardening, and beam profile correction in diagnostic (kilovoltage) and treatment (megavoltage) cone beam CT
-
10.1109/TMI.2008.928922
-
J. Maltz, B. Gangadharan, S. Bose, D. Hristov, B. Faddegon, A. Paidi, and A. Bani-Hashemi, " Algorithm for x-ray scatter, beam-hardening, and beam profile correction in diagnostic (kilovoltage) and treatment (megavoltage) cone beam CT.," IEEE Trans. Med. Imaging 27 (12), 1791-1810 (2008). 10.1109/TMI.2008.928922
-
(2008)
IEEE Trans. Med. Imaging
, vol.27
, Issue.12
, pp. 1791-1810
-
-
Maltz, J.1
Gangadharan, B.2
Bose, S.3
Hristov, D.4
Faddegon, B.5
Paidi, A.6
Bani-Hashemi, A.7
-
29
-
-
3542999607
-
Dosimetry fundamentals
-
in (Wiley-VCH, Weinheim, Germany)
-
F. Attix, " Dosimetry fundamentals.," in Introduction to Radiological Physics and Radiation Dosimetry (Wiley-VCH, Weinheim, Germany, 2007), pp. 264-291.
-
(2007)
Introduction to Radiological Physics and Radiation Dosimetry
, pp. 264-291
-
-
Attix, F.1
-
30
-
-
0019485556
-
A method for describing the doses delivered by transmission x-ray computed tomography
-
10.1118/1.594995
-
T. Shope, R. Gagne, and G. Johnson, " A method for describing the doses delivered by transmission x-ray computed tomography.," Med. Phys. 8, 488-495 (1981). 10.1118/1.594995
-
(1981)
Med. Phys.
, vol.8
, pp. 488-495
-
-
Shope, T.1
Gagne, R.2
Johnson, G.3
|