메뉴 건너뛰기




Volumn 8313, Issue , 2012, Pages

Practical considerations for intensity modulated CT

Author keywords

CT; IMCT; ring artifact; scatter correction

Indexed keywords

ATTENUATION PROPERTIES; BEAM ATTENUATORS; CT; DOSE LEVELS; FLUENCES; IMCT; LOW FREQUENCY; NOISE IMAGE; PRACTICAL ISSUES; SCANNING GEOMETRY; SCATTER CORRECTION; SCATTER RADIATION; SYSTEM GEOMETRY;

EID: 84860377570     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.911355     Document Type: Conference Paper
Times cited : (13)

References (10)
  • 1
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning (tomography): Part i. Description of system
    • Hounsfield, G. N., "Computerized transverse axial scanning (tomography): Part i. description of system," British Journal of Radiology 46, 1016-1022 (1973).
    • (1973) British Journal of Radiology , vol.46 , pp. 1016-1022
    • Hounsfield, G.N.1
  • 2
    • 34347396603 scopus 로고    scopus 로고
    • Compensators for dose and scatter management in cone-beam computed tomography
    • Graham, S., Moseley, D., Siewerdsen, J., and Jaffray, D., "Compensators for dose and scatter management in cone-beam computed tomography," Medical physics 34, 2691 (2007).
    • (2007) Medical Physics , vol.34 , pp. 2691
    • Graham, S.1    Moseley, D.2    Siewerdsen, J.3    Jaffray, D.4
  • 3
    • 77749291751 scopus 로고    scopus 로고
    • Computer-assisted scan protocol and reconstruction (caspar)?Reduction of image noise and patient dose
    • Sperl, J., Beque, D., Claus, B., De Man, B., Senzig, B., and Brokate, M., "Computer-assisted scan protocol and reconstruction (caspar)?reduction of image noise and patient dose," Medical Imaging, IEEE Transactions on 29(3), 724-732 (2010).
    • (2010) Medical Imaging, IEEE Transactions on , vol.29 , Issue.3 , pp. 724-732
    • Sperl, J.1    Beque, D.2    Claus, B.3    De Man, B.4    Senzig, B.5    Brokate, M.6
  • 4
    • 79960916886 scopus 로고    scopus 로고
    • Fluence field optimization for noise and dose objectives in ct
    • Bartolac, S., Graham, S., Siewerdsen, J., and Jaffray, D., "Fluence field optimization for noise and dose objectives in ct," Medical Physics 38, S2 (2011).
    • (2011) Medical Physics , vol.38
    • Bartolac, S.1    Graham, S.2    Siewerdsen, J.3    Jaffray, D.4
  • 6
    • 0030866641 scopus 로고    scopus 로고
    • Extraction of primary signal from EPIDs using only forward convolution
    • Hansen, V., Swindell, W., and Evans, P., "Extraction of primary signal from EPIDs using only forward convolution," Medical Physics 24, 1477 (1997).
    • (1997) Medical Physics , vol.24 , pp. 1477
    • Hansen, V.1    Swindell, W.2    Evans, P.3
  • 7
    • 56849113227 scopus 로고    scopus 로고
    • Algorithm for x-ray scatter, beam-hardening, and beam profile correction in diagnostic (kilovoltage) and treatment (megavoltage) cone beam ct
    • Maltz, J., Gangadharan, B., Bose, S., Hristov, D., Faddegon, B., Paidi, A., and Bani-Hashemi, A., "Algorithm for x-ray scatter, beam-hardening, and beam profile correction in diagnostic (kilovoltage) and treatment (megavoltage) cone beam ct," Medical Imaging, IEEE Transactions on 27(12), 1791-1810 (2008).
    • (2008) Medical Imaging, IEEE Transactions on , vol.27 , Issue.12 , pp. 1791-1810
    • Maltz, J.1    Gangadharan, B.2    Bose, S.3    Hristov, D.4    Faddegon, B.5    Paidi, A.6    Bani-Hashemi, A.7
  • 10
    • 33845562622 scopus 로고    scopus 로고
    • Scatter correction method for x-ray ct using primary modulation: Theory and preliminary results
    • Zhu, L., Bennett, N., and Fahrig, R., "Scatter correction method for x-ray ct using primary modulation: Theory and preliminary results," Medical Imaging, IEEE Transactions on 25(12), 1573-1587 (2006).
    • (2006) Medical Imaging, IEEE Transactions on , vol.25 , Issue.12 , pp. 1573-1587
    • Zhu, L.1    Bennett, N.2    Fahrig, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.