메뉴 건너뛰기




Volumn 57, Issue 3, 2013, Pages 358-363

The duration of fibre-optic intubation is increased by cricoid pressure. A randomised double-blind study

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BLOOD PRESSURE CUFF; BODY MASS; CLINICAL ARTICLE; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CRICOID PRESSURE; DOUBLE BLIND PROCEDURE; FEMALE; FIBRE OPTIC INTUBATION; GLOTTIS; GROUPS BY AGE; HUMAN; INTUBATION; MALE; MEDICAL DEVICE; PRESSURE; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL;

EID: 84873567217     PISSN: 00015172     EISSN: 13996576     Source Type: Journal    
DOI: 10.1111/j.1399-6576.2012.02789.x     Document Type: Article
Times cited : (5)

References (26)
  • 1
    • 79951481184 scopus 로고    scopus 로고
    • Bronchoaspiration: Incidence, consequences and management
    • Beck-Schimmer B, Bonvini JM,. Bronchoaspiration: incidence, consequences and management. Eur J Anaesthesiol 2011; 28: 78-84
    • (2011) Eur J Anaesthesiol , vol.28 , pp. 78-84
    • Beck-Schimmer, B.1    Bonvini, J.M.2
  • 2
    • 49749217308 scopus 로고
    • Cricoid pressure to control regurgitation of stomach contents during induction of anaesthesia
    • Sellick BA,. Cricoid pressure to control regurgitation of stomach contents during induction of anaesthesia. Lancet 1961; 2: 404-406
    • (1961) Lancet , vol.2 , pp. 404-406
    • Sellick, B.A.1
  • 3
    • 0036173720 scopus 로고    scopus 로고
    • Orotracheal fibreoptic intubation for rapid sequence induction of anaesthesia
    • DOI 10.1046/j.0003-2409.2001.02400.x
    • Pandit JJ, Dravid RM, Iyer R, Pobat MT,. Orotracheal fibreoptic intubation for rapid sequence. Anaesthesia 2002; 57: 123-127 (Pubitemid 34149948)
    • (2002) Anaesthesia , vol.57 , Issue.2 , pp. 123-127
    • Pandit, J.J.1    Dravid, R.M.2    Iyer, R.3    Popat, M.T.4
  • 4
    • 0026670039 scopus 로고
    • Regurgitation and oesophageal rupture with cricoid pressure: A cadaver study
    • Vanner RG, Pryle BJ,. Regurgitation and oesophageal rupture with cricoid pressure: a cadaver study. Anaesthesia 1992; 47: 732-735
    • (1992) Anaesthesia , vol.47 , pp. 732-735
    • Vanner, R.G.1    Pryle, B.J.2
  • 5
    • 0021792090 scopus 로고
    • A clinical sign to predict difficult tracheal intubation: A prospective study
    • Mallampati SR, Gatt SP, Gugino LD, Desai SP, Waraksa B, Freibuger D, Liu PL,. A clinical sign to predict difficult intubation: a prospective study. Can Anaesth Soc J 1985; 32: 429-434 (Pubitemid 15067953)
    • (1985) Canadian Anaesthetists Society Journal , vol.32 , Issue.4 , pp. 429-434
    • Mallampati, S.R.1    Gatt, S.P.2    Gugino, L.D.3
  • 7
    • 0021701206 scopus 로고
    • Difficult tracheal intubation in obstetrics
    • DOI 10.1111/j.1365-2044.1983.tb08932.x
    • Cormack RS, Lehane J,. Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105-1111 (Pubitemid 15103964)
    • (1984) Anaesthesia , vol.39 , Issue.11 , pp. 1105-1111
    • Cormack, R.S.1    Lehane, J.2
  • 8
    • 0037317687 scopus 로고    scopus 로고
    • The Parker Flex-Tip tube versus a standard tube for fiberoptic orotracheal intubation: A randomized double-blind study
    • DOI 10.1097/00000542-200302000-00014
    • Kristensen MS,. The Parker flex-tip tube versus a standard tube for fiberoptic orotracheal intubation: a randomized double-blind study. Anesthesiology 2003; 98: 354-358 (Pubitemid 36592802)
    • (2003) Anesthesiology , vol.98 , Issue.2 , pp. 354-358
    • Kristensen, M.S.1
  • 9
    • 74049124591 scopus 로고    scopus 로고
    • Cricoid pressure: An expert's opinion
    • Priebe HJ,. Cricoid pressure: an expert's opinion. Minerva Anestesiol 2009; 75: 710-714
    • (2009) Minerva Anestesiol , vol.75 , pp. 710-714
    • Priebe, H.J.1
  • 10
    • 70350708333 scopus 로고    scopus 로고
    • On cricoid pressure: 'May the force be with you'
    • Lerman J,. On cricoid pressure: 'may the force be with you'. Anesth Analg 2009; 109: 1363-1366
    • (2009) Anesth Analg , vol.109 , pp. 1363-1366
    • Lerman, J.1
  • 11
    • 70350738627 scopus 로고    scopus 로고
    • Sellick's maneuver: To do or not to do
    • Ovassapian A, Salem MR,. Sellick's maneuver: to do or not to do. Anesth Analg 2009; 109: 1360-1362
    • (2009) Anesth Analg , vol.109 , pp. 1360-1362
    • Ovassapian, A.1    Salem, M.R.2
  • 12
    • 77951724631 scopus 로고    scopus 로고
    • Rapid sequence induction and intubation: Current controversy
    • El-Orbany M, Connolly LA,. Rapid sequence induction and intubation: current controversy. Anesth Analg 2010; 110: 1318-1325
    • (2010) Anesth Analg , vol.110 , pp. 1318-1325
    • El-Orbany, M.1    Connolly, L.A.2
  • 13
    • 0036287136 scopus 로고    scopus 로고
    • The cricoid cartilage and the esophagus are not aligned in close to half of adult patients
    • Smith KJ, Ladak S, Choi PT-L, Dobranowski DJ,. The cricoid cartilage and the esophagus are not aligned in close to half of adult patients. Can J Anaesth 2002; 49: 503-507 (Pubitemid 34692929)
    • (2002) Canadian Journal of Anesthesia , vol.49 , Issue.5 , pp. 503-507
    • Smith, K.J.1    Ladak, S.2    Choi, P.T.-L.3    Dobranowski, J.4
  • 14
    • 84861096706 scopus 로고    scopus 로고
    • Cricoid pressure provides incomplete esophageal occlusion associated with lateral deviation: A magnetic resonance imaging study
    • Boet S, Duttchen K, Chan J, Chan AW, Morrish W, Ferland A, Hare GM, Hong AP,. Cricoid pressure provides incomplete esophageal occlusion associated with lateral deviation: a magnetic resonance imaging study. J Emerg Med 2012; 42: 606-611
    • (2012) J Emerg Med , vol.42 , pp. 606-611
    • Boet, S.1    Duttchen, K.2    Chan, J.3    Chan, A.W.4    Morrish, W.5    Ferland, A.6    Hare, G.M.7    Hong, A.P.8
  • 15
    • 62149125182 scopus 로고    scopus 로고
    • Lifesaving or ineffective? An observational study of the use of cricoid pressure and maternal outcome in an African setting
    • Fenton PM, Reynolds F,. Lifesaving or ineffective? An observational study of the use of cricoid pressure and maternal outcome in an African setting. Int J Obstet Anesth 2009; 18: 106-110
    • (2009) Int J Obstet Anesth , vol.18 , pp. 106-110
    • Fenton, P.M.1    Reynolds, F.2
  • 17
    • 13244297061 scopus 로고    scopus 로고
    • Cricoid pressure does not increase the rate of failed intubation by direct laryngoscopy in adults
    • DOI 10.1097/00000542-200502000-00012
    • Turgeon AF, Nicole PC, Trépanier CA, Mardoux S, Lessard MR,. Cricoid pressure does not increase the rate of failed intubations by direct laryngoscopy in adults. Anesthesiology 2005; 102: 315-319 (Pubitemid 40189078)
    • (2005) Anesthesiology , vol.102 , Issue.2 , pp. 315-319
    • Turgeon, A.F.1    Nicole, P.C.2    Trepanier, C.A.3    Marcoux, S.4    Lessard, M.R.5
  • 18
    • 33646516261 scopus 로고    scopus 로고
    • Laryngeal view during laryngoscopy: A randomized trial comparing cricoid pressure, backward-upward-rightward pressure, and bimanual laryngoscopy
    • Levitan RM, Kinkle WC, Levin WJ, Everett WW,. Laryngeal view during laryngoscopy: a randomized trial comparing cricoid pressure, backward-upward-rightward pressure, and bimanual laryngoscopy. Ann Emerg Med 2006; 47: 548-555
    • (2006) Ann Emerg Med , vol.47 , pp. 548-555
    • Levitan, R.M.1    Kinkle, W.C.2    Levin, W.J.3    Everett, W.W.4
  • 19
    • 77953703573 scopus 로고    scopus 로고
    • Cricoid pressure and laryngeal manipulation in 402 pre-hospital emergency anaesthetics: Essential safety measure or a hindrance to rapid safe intubation?
    • Harris T, Ellis DY, Foster L, Lockey D,. Cricoid pressure and laryngeal manipulation in 402 pre-hospital emergency anaesthetics: essential safety measure or a hindrance to rapid safe intubation? Resuscitation 2010; 81: 810-816
    • (2010) Resuscitation , vol.81 , pp. 810-816
    • Harris, T.1    Ellis, D.Y.2    Foster, L.3    Lockey, D.4
  • 20
    • 11444250097 scopus 로고    scopus 로고
    • Effect of cricoid pressure on the view at laryngoscopy
    • DOI 10.1111/j.1365-2044.2004.04010.x
    • Haslam N, Parker L, Duggan JE,. Effect of cricoid pressure on the view at laryngoscopy. Anaesthesia 2005; 60: 41-47 (Pubitemid 40081238)
    • (2005) Anaesthesia , vol.60 , Issue.1 , pp. 41-47
    • Haslam, N.1    Parker, L.2    Duggan, J.E.3
  • 21
    • 2642644606 scopus 로고    scopus 로고
    • The best view at laryngoscopy using the McCoy laryngoscope with and without cricoid pressure
    • DOI 10.1046/j.1365-2044.1998.00377.x
    • Randell T, Maattanen M, Kytta J,. The best view at laryngoscopy using the McCoy laryngoscope with and without cricoid pressure. Anaesthesia 1998; 53: 536-539 (Pubitemid 28306301)
    • (1998) Anaesthesia , vol.53 , Issue.6 , pp. 536-539
    • Randeil, T.1    Maattanen, M.2    Kytta, J.3
  • 22
    • 0036599810 scopus 로고    scopus 로고
    • Cricoid pressure decreases ease of tracheal intubation using fibreoptic laryngoscopy (WuScope System)
    • Smith CE, Boyer D,. Cricoid pressure decreases ease of tracheal intubation using fibreoptic laryngoscopy (WuScope System). Can J Anaesth 2002; 49: 614-619
    • (2002) Can J Anaesth , vol.49 , pp. 614-619
    • Smith, C.E.1    Boyer, D.2
  • 23
    • 0035006697 scopus 로고    scopus 로고
    • A comparison of the Bullard laryngoscope versus the flexible fiberoptic bronchoscope during intubation in patients afforded inline stabilization
    • DOI 10.1016/S0952-8180(01)00241-0, PII S0952818001002410
    • Shulman GB, Connelly NR,. A comparison of the Bullard laryngoscope versus the flexible fiberoptic bronchoscope during intubation in patients afforded inline stabilization. J Clin Anesth 2001; 13: 182-185 (Pubitemid 32463876)
    • (2001) Journal of Clinical Anesthesia , vol.13 , Issue.3 , pp. 182-185
    • Shulman, G.B.1    Connelly, N.R.2
  • 24
    • 0036714817 scopus 로고    scopus 로고
    • Effect of cricoid pressure on the ease of fibrescope-aided tracheal intubation
    • DOI 10.1046/j.1365-2044.2002.02706.x
    • Asai T, Murao K, Johmura S, Shingu K,. Effect of cricoid pressure on the ease of fibrescope-aided tracheal intubation. Anaesthesia 2002; 57: 909-913 (Pubitemid 35021515)
    • (2002) Anaesthesia , vol.57 , Issue.9 , pp. 909-913
    • Asai, T.1    Murao, K.2    Johmura, S.3    Shingu, K.4
  • 25
    • 33745016924 scopus 로고    scopus 로고
    • Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients
    • DOI 10.1111/j.1365-2044.2006.04704.x
    • Greenland KB, Ha ID, Irwin MG,. Comparison of the Berman intubating airway and the Williamson airway intubator for fibreoptic orotracheal intubation in anaesthetised patients. Anaesthesia 2006; 61: 678-684 (Pubitemid 43871477)
    • (2006) Anaesthesia , vol.61 , Issue.7 , pp. 678-684
    • Greenland, K.B.1    Ha, I.D.2    Irwin, M.G.3
  • 26
    • 0030875908 scopus 로고    scopus 로고
    • Comparison between the Ovassapian intubating airway and the Berman intubating airway in fibreoptic intubation
    • Randell T, Valli H, Hakala P,. Comparison between the Ovassapian intubating airway and the Berman intubating airway in fibreoptic intubation. Eur J Anaesthesiol 1997; 14: 380-384 (Pubitemid 27427375)
    • (1997) European Journal of Anaesthesiology , vol.14 , Issue.4 , pp. 380-384
    • Randell, T.1    Valli, H.2    Hakala, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.