메뉴 건너뛰기




Volumn 14, Issue 4, 1997, Pages 380-384

Comparison between the Ovassapian intubating airway and the Berman intubating airway in fibreoptic intubation

Author keywords

Berman airway; Intubation, difficulties in, fibreoptic; Ovassapian airway

Indexed keywords

ADULT; AIRWAY; ARTICLE; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; ENDOSCOPY; ENDOTRACHEAL INTUBATION; FEMALE; FIBEROSCOPE; HUMAN; LARYNGOSCOPY; MAJOR CLINICAL STUDY; MALE; RANDOMIZED CONTROLLED TRIAL; VOCAL CORD;

EID: 0030875908     PISSN: 02650215     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003643-199707000-00007     Document Type: Article
Times cited : (31)

References (9)
  • 2
    • 0028890145 scopus 로고
    • Fibreoptic intubation and bronchofibreoscopy in anaesthesia and intensive care
    • Randell T, Hakala P. Fibreoptic intubation and bronchofibreoscopy in anaesthesia and intensive care. Acta Anaesthesiol Scand 1995; 39: 3-16.
    • (1995) Acta Anaesthesiol Scand , vol.39 , pp. 3-16
    • Randell, T.1    Hakala, P.2
  • 3
    • 0029080664 scopus 로고
    • Comparison between two fibrescopes with different diameter of the insertion cord for fibreoptic intubation
    • Hakala P, Randell T. Comparison between two fibrescopes with different diameter of the insertion cord for fibreoptic intubation. Anaesthesia 1995; 50: 735-737.
    • (1995) Anaesthesia , vol.50 , pp. 735-737
    • Hakala, P.1    Randell, T.2
  • 4
    • 0027275548 scopus 로고
    • Fibreoptic intubation. Influence of tracheal tube tip design
    • Jones HE, Pearce AC, Moore P. Fibreoptic intubation. Influence of tracheal tube tip design. Anaesthesia 1993; 48: 672-674.
    • (1993) Anaesthesia , vol.48 , pp. 672-674
    • Jones, H.E.1    Pearce, A.C.2    Moore, P.3
  • 5
    • 0025922063 scopus 로고
    • Comparison of two methods of fibrescope-guided tracheal intubation
    • Smith JE, Mackenzie AA, Scott-Knight VCE. Comparison of two methods of fibrescope-guided tracheal intubation. Br J Anaesth 1991; 66: 546-550.
    • (1991) Br J Anaesth , vol.66 , pp. 546-550
    • Smith, J.E.1    Mackenzie, A.A.2    Scott-Knight, V.C.E.3
  • 6
    • 0026089326 scopus 로고
    • Sample size estimation for comparing two or more treatment groups in clinical trials
    • Day JS, Graham DF. Sample size estimation for comparing two or more treatment groups in clinical trials. Stat Med 1991; 10: 33-43.
    • (1991) Stat Med , vol.10 , pp. 33-43
    • Day, J.S.1    Graham, D.F.2
  • 7
    • 0042034756 scopus 로고
    • Intubation procedure and causes of difficult intubation
    • Latto IP, Rosen M, eds. London: Bailière Tindall
    • Murrin KR. Intubation procedure and causes of difficult intubation. In: Latto IP, Rosen M, eds. Difficulties in Tracheal Intubation. London: Bailière Tindall, 1985: 75-89.
    • (1985) Difficulties in Tracheal Intubation , pp. 75-89
    • Murrin, K.R.1
  • 8
    • 0024724232 scopus 로고
    • A maneuver to facilitate flexible fiberoptic intubation
    • Schwartz D, Johnson C, Roberts J. A maneuver to facilitate flexible fiberoptic intubation. Anesthesiology 1989; 71: 470-471.
    • (1989) Anesthesiology , vol.71 , pp. 470-471
    • Schwartz, D.1    Johnson, C.2    Roberts, J.3
  • 9
    • 0026542026 scopus 로고
    • When the endotracheal tube will not pass over the flexible fiberoptic bronchoscope
    • Katsnelson T, Frost EAM, Farcon E, Goldiner PL. When the endotracheal tube will not pass over the flexible fiberoptic bronchoscope. Anesthesiology 1992; 76: 151-152.
    • (1992) Anesthesiology , vol.76 , pp. 151-152
    • Katsnelson, T.1    Frost, E.A.M.2    Farcon, E.3    Goldiner, P.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.