메뉴 건너뛰기




Volumn 16, Issue 1, 2013, Pages 46-50

Impedance variations over time for a closed-loop neurostimulation device: Early experience with chronically implanted electrodes

Author keywords

Cerebral cortex stimulation; chronic; electrodes; impedance; implant; neural interface; neurostimulation; responsive neurostimulation; stability

Indexed keywords

ADULT; CLINICAL ARTICLE; ELECTRODE IMPLANT; FEMALE; FOLLOW UP; HUMAN; IMPEDANCE; MALE; MEDICAL DEVICE; NERVE STIMULATION; NEUROSTIMULATION DEVICE; POTENTIAL DIFFERENCE; RETROSPECTIVE STUDY; REVIEW; TREND STUDY;

EID: 84873407772     PISSN: 10947159     EISSN: 15251403     Source Type: Journal    
DOI: 10.1111/j.1525-1403.2012.00529.x     Document Type: Review
Times cited : (26)

References (9)
  • 1
    • 72449201490 scopus 로고    scopus 로고
    • Influence of the implanted pulse generator as reference electrode in finite element model of monopolar deep brain stimulation
    • Walckiers G, Fuchs B, Thiran JP, Mosig JR, Pollo C,. Influence of the implanted pulse generator as reference electrode in finite element model of monopolar deep brain stimulation. J Neurosci Methods 2010; 186: 90-96.
    • (2010) J Neurosci Methods , vol.186 , pp. 90-96
    • Walckiers, G.1    Fuchs, B.2    Thiran, J.P.3    Mosig, J.R.4    Pollo, C.5
  • 2
    • 0034858243 scopus 로고    scopus 로고
    • Spectrum of clinical and histopathologic responses to intracranial electrodes: From multifocal aseptic meningitis to multifocal hypersensitivity-type meningovasculitis
    • Stephan CL, Kepes JJ, SantaCruz K, Wilkinson SB, Fegley B, Osorio I,. Spectrum of clinical and histopathologic responses to intracranial electrodes: from multifocal aseptic meningitis to multifocal hypersensitivity-type meningovasculitis. Epilepsia 2001; 42: 895-901.
    • (2001) Epilepsia , vol.42 , pp. 895-901
    • Stephan, C.L.1    Kepes, J.J.2    Santacruz, K.3    Wilkinson, S.B.4    Fegley, B.5    Osorio, I.6
  • 3
    • 26444445003 scopus 로고    scopus 로고
    • Response of brain tissue to chronically implanted neural electrodes
    • Epub 2005 Sep 27
    • Polikov VS, Tresco PA, Reichert WM,. Response of brain tissue to chronically implanted neural electrodes. J Neurosci Methods 2005; 148: 1-18. Epub 2005 Sep 27.
    • (2005) J Neurosci Methods , vol.148 , pp. 1-18
    • Polikov, V.S.1    Tresco, P.A.2    Reichert, W.M.3
  • 4
    • 32444437700 scopus 로고    scopus 로고
    • Sources and effects of electrode impedance during deep brain stimulation
    • Butson CR, Maks CB, McIntyre CC,. Sources and effects of electrode impedance during deep brain stimulation. Clin Neurophysiol 2006; 117: 447-454.
    • (2006) Clin Neurophysiol , vol.117 , pp. 447-454
    • Butson, C.R.1    Maks, C.B.2    McIntyre, C.C.3
  • 5
    • 26044437993 scopus 로고    scopus 로고
    • Cerebral monitoring in the operating room and the intensive care unit: An introductory for the clinician and a guide for the novice wanting to open a window to the brain. Part I: The electroencephalogram
    • Freye E, Levy JV,. Cerebral monitoring in the operating room and the intensive care unit: an introductory for the clinician and a guide for the novice wanting to open a window to the brain. Part I: The electroencephalogram. J Clin Monit Comput 2005; 19: 1-76.
    • (2005) J Clin Monit Comput , vol.19 , pp. 1-76
    • Freye, E.1    Levy, J.V.2
  • 6
    • 84873413939 scopus 로고    scopus 로고
    • Electrical properties of normal and scarred skin
    • Conf Proc 29 Oct-1 Nov
    • Zhao L, Hung LK, Zhang YT,. Electrical properties of normal and scarred skin. Conf Proc IEEE Eng Med Biol Soc. 29 Oct-1 Nov 1998; 6: 2917-2920.
    • (1998) IEEE Eng Med Biol Soc. , vol.6 , pp. 2917-2920
    • Zhao, L.1    Hung, L.K.2    Zhang, Y.T.3
  • 7
    • 84873414472 scopus 로고    scopus 로고
    • Neuropace, Inc. Personal communication. 24 Jan
    • Neuropace, Inc. Field clinical engineer. Personal communication. 24 Jan 2011.
    • (2011) Field Clinical Engineer
  • 9
    • 78049285733 scopus 로고    scopus 로고
    • Current-controlled deep brain stimulation reduces in vivo voltage fluctuations observed during voltage-controlled stimulation
    • Lempka SF, Johnson MD, Miocinovic S, Vitek JL, McIntyre CC,. Current-controlled deep brain stimulation reduces in vivo voltage fluctuations observed during voltage-controlled stimulation. Clin Neurophysiol 2010; 121: 2128-2133.
    • (2010) Clin Neurophysiol , vol.121 , pp. 2128-2133
    • Lempka, S.F.1    Johnson, M.D.2    Miocinovic, S.3    Vitek, J.L.4    McIntyre, C.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.