메뉴 건너뛰기




Volumn 33, Issue 2, 2013, Pages 215-224

Measuring biexponential transverse relaxation of the ASL signal at 9.4 T to estimate arterial oxygen saturation and the time of exchange of labeled blood water into cortical brain tissue

Author keywords

arterial spin labeling; ASL; cerebral hemodynamics; exchange; functional MRI (fMRI); MRI

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTERIAL OXYGEN SATURATION; ARTERIAL SPIN LABELING; ARTICLE; BLOOD; BRAIN CORTEX; BRAIN TISSUE; CONTROLLED STUDY; EXTRAVASCULAR SPACE; FUNCTIONAL MAGNETIC RESONANCE IMAGING; MALE; NONHUMAN; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RAT; SPIN LABELING; VASCULARIZATION;

EID: 84873404725     PISSN: 0271678X     EISSN: 15597016     Source Type: Journal    
DOI: 10.1038/jcbfm.2012.156     Document Type: Article
Times cited : (40)

References (41)
  • 1
    • 0014959978 scopus 로고
    • Blood Velocity Measurements in Intact Subjects
    • Morse OC, Singer Jr. Blood Velocity Measurements in Intact Subjects. Science 1970; 170: 440-441.
    • (1970) Science , vol.170 , pp. 440-441
    • Morse, O.C.1    Singer, J.R.2
  • 3
    • 0026542167 scopus 로고
    • Magnetic resonance imaging of perfusion using spin inversion of arterial water
    • Williams DS, Detre JA, Leigh JS, Koretsky AP. Magnetic resonance imaging of perfusion using spin inversion of arterial water. Proc Natl Acad Sci 1992; 89: 212-216.
    • (1992) Proc Natl Acad Sci , vol.89 , pp. 212-216
    • Williams, D.S.1    Detre, J.A.2    Leigh, J.S.3    Koretsky, A.P.4
  • 4
    • 34250788041 scopus 로고    scopus 로고
    • Clinical neuroimaging using arterial spin-labeledperfusion magnetic resonance imaging
    • Wolf RL, Detre JA. Clinical neuroimaging using arterial spin-labeledperfusion magnetic resonance imaging. Neurotherapeutics 2007; 4: 346-359.
    • (2007) Neurotherapeutics , vol.4 , pp. 346-359
    • Wolf, R.L.1    Detre, J.A.2
  • 7
    • 0029151256 scopus 로고
    • Quantification of regional cerebral blood flow change by flow sensitive alternating inversion recovery (FAIR). Application to functional mapping
    • Kim SG. Quantification of regional cerebral blood flow change by flow sensitive alternating inversion recovery (FAIR). Application to functional mapping. Magn Reson Med 1995; 34: 293-301.
    • (1995) Magn Reson Med , vol.34 , pp. 293-301
    • Kim, S.G.1
  • 8
    • 0029952944 scopus 로고    scopus 로고
    • Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    • Alsop DC, Detre JA. Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow. J Cereb Blood Flow Metab 1996; 16: 1236-1249.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 1236-1249
    • Alsop, D.C.1    Detre, J.A.2
  • 9
    • 0026549870 scopus 로고
    • Measurement of blood-brain barrier permeability using dynamic Gd-DTPA scanning-A comparison of methods
    • Larsson HB, Tofts PS. Measurement of blood-brain barrier permeability using dynamic Gd-DTPA scanning-a comparison of methods. Magn Reson Med 1992; 24: 174-176.
    • (1992) Magn Reson Med , vol.24 , pp. 174-176
    • Larsson, H.B.1    Tofts, P.S.2
  • 10
    • 0030851658 scopus 로고    scopus 로고
    • Evidence for the exchange of arterial spin labeled water with tissue water in rat brain from diffusion-sensitized measurements of perfusion
    • Silva AC, Williams DS, Koretsky AP. Evidence for the exchange of arterial spin labeled water with tissue water in rat brain from diffusion-sensitized measurements of perfusion. Magn Reson Med 1997a; 38: 232-237.
    • (1997) Magn Reson Med , vol.38 , pp. 232-237
    • Silva, A.C.1    Williams, D.S.2    Koretsky, A.P.3
  • 11
    • 0031726507 scopus 로고    scopus 로고
    • Continuous Assessment of Perfusion by Tagging Including Volume and water Extraction (CAPTIVE): A steady-state contrast agent technique for measuring blood flow, relative blood volume fraction and the water extraction fraction
    • Wang J, Fernandez-Serra MA, Wang S, Marota JJA, Shimizu-Sasamata M, Weisskoff RM et al. Continuous Assessment of Perfusion by Tagging Including Volume and water Extraction (CAPTIVE): a steady-state contrast agent technique for measuring blood flow, relative blood volume fraction and the water extraction fraction. Magn Reson Med 1998; 40: 666-678.
    • (1998) Magn Reson Med , vol.40 , pp. 666-678
    • Wang, J.1    Fernandez-Serra, M.A.2    Wang, S.3    Jja, M.4    Shimizu-Sasamata, M.5    Weisskoff, R.M.6
  • 13
    • 0024698137 scopus 로고
    • Two-exponential analysis of spin-spin proton relaxation time in MR imaging using surface coils
    • Schad LR, Brix G, Semmler W, Guckel F, Lorenz WJ. Two-exponential analysis of spin-spin proton relaxation time in MR imaging using surface coils. Magn Reson Imaging 1989; 7: 357-362.
    • (1989) Magn Reson Imaging , vol.7 , pp. 357-362
    • Schad, L.R.1    Brix, G.2    Semmler, W.3    Guckel, F.4    Lorenz, W.J.5
  • 14
    • 71949101209 scopus 로고    scopus 로고
    • Characterising the Origin of the Arterial Spin Labelling Signal in MRI using a Multi-Echo Acquisition Approach
    • Wells JA, Lythgoe MF, Choy M, Gadian DG, Ordidge RJ, Thomas DL. Characterising the Origin of the Arterial Spin Labelling Signal in MRI using a Multi-Echo Acquisition Approach. J Cereb Blood Flow Metab 2009; 29: 1836-1845.
    • (2009) J Cereb Blood Flow Metab , vol.29 , pp. 1836-1845
    • Wells, J.A.1    Lythgoe, M.F.2    Choy, M.3    Gadian, D.G.4    Ordidge, R.J.5    Thomas, D.L.6
  • 15
    • 0028290563 scopus 로고
    • Capillary perfusion of the rat brain cortex: An in vitro confocal microscopy study
    • Villringer A, Them A, Lindauer U, Einhaaupl K, Dirangl U. Capillary perfusion of the rat brain cortex: an in vitro confocal microscopy study. Circ Res 1994; 75: 55-62.
    • (1994) Circ Res , vol.75 , pp. 55-62
    • Villringer, A.1    Them, A.2    Lindauer, U.3    Einhaaupl, K.4    Dirangl, U.5
  • 16
    • 79954451109 scopus 로고    scopus 로고
    • Determination of spin compartment in arterial spin labeling mri
    • Liu P, Uh J, Lu H. Determination of spin compartment in arterial spin labeling MRI. Magn Reson Med 2011; 65: 120-127.
    • (2011) Magn Reson Med , vol.65 , pp. 120-127
    • Liu, P.1    Uh, J.2    Lu, H.3
  • 17
    • 76349122214 scopus 로고    scopus 로고
    • Changes in cerebral arterial, tissue and venous oxygenation with evoked neural stimulation: Implications for hemoglobin-based functional neuroimaging
    • Vazquez AL, Fukuda M, Tasker ML, Masamoto K, Kim SG. Changes in cerebral arterial, tissue and venous oxygenation with evoked neural stimulation: implications for hemoglobin-based functional neuroimaging. J Cereb Blood Flow Metab 2010; 30: 428-439.
    • (2010) J Cereb Blood Flow Metab , vol.30 , pp. 428-439
    • Vazquez, A.L.1    Fukuda, M.2    Tasker, M.L.3    Masamoto, K.4    Kim, S.G.5
  • 18
    • 0032729595 scopus 로고    scopus 로고
    • Diffusion-weighted spin-echo fMRI at 9.4T: Microvascular/tissue contribution to BOLD signal changes
    • Lee SP, Silva AC, Ugurbil K, Kim SG. Diffusion-weighted spin-echo fMRI at 9.4T: microvascular/tissue contribution to BOLD signal changes. Magn Reson Med 1999; 42: 919-928.
    • (1999) Magn Reson Med , vol.42 , pp. 919-928
    • Lee, S.P.1    Silva, A.C.2    Ugurbil, K.3    Kim, S.G.4
  • 22
    • 0035216720 scopus 로고    scopus 로고
    • Quantitative measurements of cerebral metabolic rate of oxygen utilization using MRI: A volunteer study
    • An H, Lin W, Celik A, Lee YZ. Quantitative measurements of cerebral metabolic rate of oxygen utilization using MRI: a volunteer study. NMR Biomed 2001; 14: 441-447.
    • (2001) NMR Biomed , vol.14 , pp. 441-447
    • An, H.1    Lin, W.2    Celik, A.3    Lee, Y.Z.4
  • 23
    • 53549089633 scopus 로고    scopus 로고
    • Validation of oxygen extraction fraction measurement by qBOLD technique
    • He X, Zhu M, Yablonskiy DA. Validation of oxygen extraction fraction measurement by qBOLD technique. Magn Reson Med 2008; 60: 882-888.
    • (2008) Magn Reson Med , vol.60 , pp. 882-888
    • He, X.1    Zhu, M.2    Yablonskiy, D.A.3
  • 24
    • 33846085587 scopus 로고    scopus 로고
    • Mapping of human cerebral deox-ygenated blood volume and oxygen extraction fraction: Default state
    • He X, Yablonskiy DA. Quantitative BOLD: Mapping of human cerebral deox-ygenated blood volume and oxygen extraction fraction: default state. Magn Reson Med 2007; 57: 115-126.
    • (2007) Magn Reson Med , vol.57 , pp. 115-126
    • He, X.1    Yablonskiy, D.A.2    Bold, Q.3
  • 26
    • 84866274548 scopus 로고    scopus 로고
    • The importance of rf bandwidth for effective tagging in pulsed arterial spin labelling mri at 9.4t
    • Wells JA, Siow B, Lythgoe MF, Thomas DL. The importance of RF bandwidth for effective tagging in pulsed arterial spin labelling MRI at 9.4T. NMR Biomed 2012; 25: 1139-1143.
    • (2012) NMR Biomed , vol.25 , pp. 1139-1143
    • Wells, J.A.1    Siow, B.2    Lythgoe, M.F.3    Thomas, D.L.4
  • 28
    • 35148864609 scopus 로고    scopus 로고
    • Quantification of rodent cerebral blood flow (CBF) in normal and high flow states using pulsed arterial spin labelling magnetic resonance imaging
    • Wegener S, Wu WC, Perthen JE, Wong EC. Quantification of rodent cerebral blood flow (CBF) in normal and high flow states using pulsed arterial spin labelling magnetic resonance imaging. J Magn Reson Imaging 2007; 26: 855-862.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 855-862
    • Wegener, S.1    Wu, W.C.2    Perthen, J.E.3    Wong, E.C.4
  • 29
    • 0036325034 scopus 로고    scopus 로고
    • Comparison of quantitative perfusion imaging using arterial spin labelling at 1.5 and 4.0 Tesla
    • Wang J, Alsop DC, Li L, Listerud J, Gonzalez-At JB, Schnall MD et al. Comparison of quantitative perfusion imaging using arterial spin labelling at 1.5 and 4.0 Tesla. Magn Reson Med 2002; 48: 242-254.
    • (2002) Magn Reson Med , vol.48 , pp. 242-254
    • Wang, J.1    Alsop, D.C.2    Li, L.3    Listerud, J.4    Gonzalez-At, J.B.5    Schnall, M.D.6
  • 30
    • 0021991039 scopus 로고
    • What is the correct value for the bloodbrain partition coefficient for water?
    • Herscovitch P, Raichle ME. What is the correct value for the bloodbrain partition coefficient for water? J Cereb Blood Flow Metab 1985; 5: 65-69.
    • (1985) J Cereb Blood Flow Metab , vol.5 , pp. 65-69
    • Herscovitch, P.1    Raichle, M.E.2
  • 31
    • 34249332064 scopus 로고    scopus 로고
    • Determination of blood longitudinal relaxation time (T1) at high magnetic field strengths
    • Dobre MC, Ugurbil K, Marjanska M. Determination of blood longitudinal relaxation time (T1) at high magnetic field strengths. Magn Reson Imaging 2007; 25: 733-735.
    • (2007) Magn Reson Imaging , vol.25 , pp. 733-735
    • Dobre, M.C.1    Ugurbil, K.2    Marjanska, M.3
  • 32
    • 16444386295 scopus 로고    scopus 로고
    • Experimental measurement of extravascular parenchymal BOLD effects and tissue oxygen extraction fractions using multi-echo VASO fMRI at 1.5 and 3.0T
    • Lu H, van Zijl PCM. Experimental measurement of extravascular parenchymal BOLD effects and tissue oxygen extraction fractions using multi-echo VASO fMRI at 1.5 and 3.0T. Magn Reson Med 2005; 53: 808-816.
    • (2005) Magn Reson Med , vol.53 , pp. 808-816
    • Lu, H.1    Van Zijl, P.C.M.2
  • 33
    • 0014888279 scopus 로고
    • Measurement of brain uptake of radiolabeled substancesusing a tritiated water internal standard
    • Oldendorf WH. Measurement of brain uptake of radiolabeled substancesusing a tritiated water internal standard. Brain Res 1970; 24: 372-376.
    • (1970) Brain Res , vol.24 , pp. 372-376
    • Oldendorf, W.H.1
  • 34
    • 0014543908 scopus 로고
    • The determination of regional cerebral blood flow by means of water labeled with radioactive oxygen 15
    • Ter-Pogossian MM, Eichling JO, Davis DO, Welch MJ, Metzger JM. The determination of regional cerebral blood flow by means of water labeled with radioactive oxygen 15. Radiology 1969; 93: 31.
    • (1969) Radiology , vol.93 , pp. 31
    • Ter-Pogossian, M.M.1    Eichling, J.O.2    Davis, D.O.3    Welch, M.J.4    Metzger, J.M.5
  • 36
    • 84859702444 scopus 로고    scopus 로고
    • Reduced resolution transit delay prescan for quantitative continuous arterial spin labeling perfusion imaging
    • Dai W, Robson PM, Shankaranarayanan A, Alsop DC. Reduced resolution transit delay prescan for quantitative continuous arterial spin labeling perfusion imaging. Magn Reson Med 2012; 67: 1252-1265.
    • (2012) Magn Reson Med , vol.67 , pp. 1252-1265
    • Dai, W.1    Robson, P.M.2    Shankaranarayanan, A.3    Alsop, D.C.4
  • 37
    • 49049091751 scopus 로고    scopus 로고
    • Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI
    • Lu H, Ge Y. Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI. Magn Reson Med 2008; 60: 357-363.
    • (2008) Magn Reson Med , vol.60 , pp. 357-363
    • Lu, H.1    Ge, Y.2
  • 38
    • 84867866451 scopus 로고    scopus 로고
    • Venous oxygenation mapping using velocity-selective excitation and arterial nulling
    • doi:10.1002/mrm.24145
    • Guo J, Wong EC. Venous oxygenation mapping using velocity-selective excitation and arterial nulling. Magn Res Med 2012. doi:10.1002/mrm.24145.
    • (2012) Magn Res Med
    • Guo, J.1    Wong, E.C.2
  • 40
    • 84856213190 scopus 로고    scopus 로고
    • Transmembrane dynamics of water exchange in human brain
    • He X, Raichle ME, Yablonskiy DA. Transmembrane dynamics of water exchange in human brain. Magn Reson Med 2012; 67: 562-571.
    • (2012) Magn Reson Med , vol.67 , pp. 562-571
    • He, X.1    Raichle, M.E.2    Yablonskiy, D.A.3
  • 41
    • 3543130199 scopus 로고    scopus 로고
    • Imaging oxygen consumption in forepaw somatosensory stimulation in rats under isoflurane anesthesia
    • Liu ZM, Schmidt KF, Sicard KM, Duong TQ. Imaging oxygen consumption in forepaw somatosensory stimulation in rats under isoflurane anesthesia. Magn Reson Med 2004; 52: 277-285.
    • (2004) Magn Reson Med , vol.52 , pp. 277-285
    • Liu, Z.M.1    Schmidt, K.F.2    Sicard, K.M.3    Duong, T.Q.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.