메뉴 건너뛰기




Volumn 73, Issue 1, 2013, Pages 136-140

Identifying the perfusion deficit in acute stroke with resting-state functional magnetic resonance imaging

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BOLD SIGNAL; BRAIN ISCHEMIA; BRAIN PERFUSION; CLINICAL ARTICLE; FEMALE; FUNCTIONAL MAGNETIC RESONANCE IMAGING; FUNCTIONAL NEUROIMAGING; HUMAN; IMAGE PROCESSING; INTERMETHOD COMPARISON; MALE; PERFUSION WEIGHTED IMAGING; PRIORITY JOURNAL;

EID: 84873361411     PISSN: 03645134     EISSN: 15318249     Source Type: Journal    
DOI: 10.1002/ana.23763     Document Type: Article
Times cited : (109)

References (16)
  • 1
    • 80052557320 scopus 로고    scopus 로고
    • Computed tomography and magnetic resonance perfusion imaging in ischemic stroke: Definitions and thresholds
    • Dani KA, Thomas RG, Chappell FM, et al. Computed tomography and magnetic resonance perfusion imaging in ischemic stroke: definitions and thresholds. Ann Neurol 2011; 70: 384-401.
    • (2011) Ann Neurol , vol.70 , pp. 384-401
    • Dani, K.A.1    Thomas, R.G.2    Chappell, F.M.3
  • 2
  • 3
    • 0029940733 scopus 로고    scopus 로고
    • Hyperacute stroke: Evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MR imaging
    • Sorensen AG, Buonanno FS, Gonzalez RG, et al. Hyperacute stroke: evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MR imaging. Radiology 1996; 199: 391-401.
    • (1996) Radiology , vol.199 , pp. 391-401
    • Sorensen, A.G.1    Buonanno, F.S.2    Gonzalez, R.G.3
  • 4
    • 74849135897 scopus 로고    scopus 로고
    • Neuroimaging in acute ischaemic stroke: Insights into unanswered questions of pathophysiology
    • Wardlaw JM,. Neuroimaging in acute ischaemic stroke: insights into unanswered questions of pathophysiology. J Intern Med 2010; 267: 172-190.
    • (2010) J Intern Med , vol.267 , pp. 172-190
    • Wardlaw, J.M.1
  • 5
    • 0032776053 scopus 로고    scopus 로고
    • Combined diffusion and perfusion MRI with correlation to single-photon emission CT in acute ischemic stroke. Ischemic penumbra predicts infarct growth
    • Karonen JO, Vanninen RL, Liu Y, et al. Combined diffusion and perfusion MRI with correlation to single-photon emission CT in acute ischemic stroke. Ischemic penumbra predicts infarct growth. Stroke 1999; 30: 1583-1590.
    • (1999) Stroke , vol.30 , pp. 1583-1590
    • Karonen, J.O.1    Vanninen, R.L.2    Liu, Y.3
  • 6
    • 0032738040 scopus 로고    scopus 로고
    • The ischemic penumbra: Operationally defined by diffusion and perfusion MRI
    • Schlaug G, Benfield A, Baird AE, et al. The ischemic penumbra: operationally defined by diffusion and perfusion MRI. Neurology 1999; 53: 1528-1537.
    • (1999) Neurology , vol.53 , pp. 1528-1537
    • Schlaug, G.1    Benfield, A.2    Baird, A.E.3
  • 7
    • 0019822988 scopus 로고
    • Thresholds in cerebral ischemia - The ischemic penumbra
    • Astrup J, Siesjo BK, Symon L,. Thresholds in cerebral ischemia-the ischemic penumbra. Stroke 1981; 12: 723-725.
    • (1981) Stroke , vol.12 , pp. 723-725
    • Astrup, J.1    Siesjo, B.K.2    Symon, L.3
  • 8
    • 0036791848 scopus 로고    scopus 로고
    • Effect of intravenous thrombolysis on MRI parameters and functional outcome in acute stroke <6 hours
    • Rother J, Schellinger PD, Gass A, et al. Effect of intravenous thrombolysis on MRI parameters and functional outcome in acute stroke <6 hours. Stroke 2002; 33: 2438-2445.
    • (2002) Stroke , vol.33 , pp. 2438-2445
    • Rother, J.1    Schellinger, P.D.2    Gass, A.3
  • 10
    • 0023847908 scopus 로고
    • Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effects
    • Villringer A, Rosen BR, Belliveau JW, et al. Dynamic imaging with lanthanide chelates in normal brain: contrast due to magnetic susceptibility effects. Magn Reson Med 1988; 6: 164-174.
    • (1988) Magn Reson Med , vol.6 , pp. 164-174
    • Villringer, A.1    Rosen, B.R.2    Belliveau, J.W.3
  • 11
    • 77956062576 scopus 로고    scopus 로고
    • Time lag dependent multimodal processing of concurrent fMRI and near-infrared spectroscopy (NIRS) data suggests a global circulatory origin for low-frequency oscillation signals in human brain
    • Tong Y, Frederick BD,. Time lag dependent multimodal processing of concurrent fMRI and near-infrared spectroscopy (NIRS) data suggests a global circulatory origin for low-frequency oscillation signals in human brain. Neuroimage 2010; 53: 553-564.
    • (2010) Neuroimage , vol.53 , pp. 553-564
    • Tong, Y.1    Frederick, B.D.2
  • 12
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
    • Ostergaard L, Weisskoff RM, Chesler DA, et al. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis. Magn Reson Med 1996; 36: 715-725.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Ostergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3
  • 13
    • 32344440764 scopus 로고    scopus 로고
    • The association between neurological deficit in acute ischemic stroke and mean transit time: Comparison of four different perfusion MRI algorithms
    • Schellinger PD, Latour LL, Wu CS, et al. The association between neurological deficit in acute ischemic stroke and mean transit time: comparison of four different perfusion MRI algorithms. Neuroradiology 2006; 48: 69-77.
    • (2006) Neuroradiology , vol.48 , pp. 69-77
    • Schellinger, P.D.1    Latour, L.L.2    Wu, C.S.3
  • 14
    • 0037221813 scopus 로고    scopus 로고
    • Reliability of mean transit time obtained using perfusion-weighted MR imaging; Comparison with positron emission tomography
    • Mihara F, Kuwabara Y, Tanaka A, et al. Reliability of mean transit time obtained using perfusion-weighted MR imaging; comparison with positron emission tomography. Magn Reson Imaging 2003; 21: 33-39.
    • (2003) Magn Reson Imaging , vol.21 , pp. 33-39
    • Mihara, F.1    Kuwabara, Y.2    Tanaka, A.3
  • 15
    • 33747590330 scopus 로고    scopus 로고
    • Non-invasive measurement of perfusion: A critical review of arterial spin labelling techniques
    • Petersen ET, Zimine I, Ho YC, Golay X,. Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques. Br J Radiol 2006; 79: 688-701.
    • (2006) Br J Radiol , vol.79 , pp. 688-701
    • Petersen, E.T.1    Zimine, I.2    Ho, Y.C.3    Golay, X.4
  • 16
    • 84860225375 scopus 로고    scopus 로고
    • Whole-brain arterial spin labeling perfusion MRI in patients with acute stroke
    • Bokkers RP, Hernandez DA, Merino JG, et al. Whole-brain arterial spin labeling perfusion MRI in patients with acute stroke. Stroke 2012; 43: 1290-1294.
    • (2012) Stroke , vol.43 , pp. 1290-1294
    • Bokkers, R.P.1    Hernandez, D.A.2    Merino, J.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.