메뉴 건너뛰기




Volumn 37, Issue 2, 2013, Pages 217-221

Enhancement of Hemocompatibility of the MERA Monopivot Centrifugal Pump: Toward Medium-Term Use

Author keywords

Artificial heart; Bridge to decision; Centrifugal pump; Circulatory assist; Durability test; Hemolysis test; In vitro thrombogenicity test; Monopivot

Indexed keywords

ARTIFICIAL HEART; BLOOD; CENTRIFUGAL PUMPS; CENTRIFUGATION; DURABILITY; LEFT VENTRICULAR ASSIST DEVICES; TESTING;

EID: 84873295588     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2012.01530.x     Document Type: Article
Times cited : (14)

References (5)
  • 1
    • 42649142928 scopus 로고    scopus 로고
    • Bridge to decision using the Levitronix CentriMag short-term ventricular assist device
    • Robertis FD, Rogers P, Amrani M, etal. Bridge to decision using the Levitronix CentriMag short-term ventricular assist device. J Heart Lung Transplant 2008;27:474-8.
    • (2008) J Heart Lung Transplant , vol.27 , pp. 474-478
    • Robertis, F.D.1    Rogers, P.2    Amrani, M.3
  • 2
    • 44849106771 scopus 로고    scopus 로고
    • Antithrombogenic properties of a monopivot magnetic-suspension centrifugal pump for circulatory assist
    • Yamane T, Maruyama O, Nishida M, etal. Antithrombogenic properties of a monopivot magnetic-suspension centrifugal pump for circulatory assist. Artif Organs 2008;32:484-9.
    • (2008) Artif Organs , vol.32 , pp. 484-489
    • Yamane, T.1    Maruyama, O.2    Nishida, M.3
  • 3
    • 68849091135 scopus 로고    scopus 로고
    • Simple in vitro testing method for antithrombogenic evaluation of centrifugal blood pumps
    • Maruyama O, Tomari Y, Sugiyama D, Nishida M, Tsutsui T, Yamane T. Simple in vitro testing method for antithrombogenic evaluation of centrifugal blood pumps. ASAIO J 2009;55:314-22.
    • (2009) ASAIO J , vol.55 , pp. 314-322
    • Maruyama, O.1    Tomari, Y.2    Sugiyama, D.3    Nishida, M.4    Tsutsui, T.5    Yamane, T.6
  • 4
    • 62949218626 scopus 로고    scopus 로고
    • Hemocompatibility evaluation with experimental and computational fluid dynamic analyses for a monopivot circulatory assist pump
    • Nishida M, Maruyama O, Kosaka R, etal. Hemocompatibility evaluation with experimental and computational fluid dynamic analyses for a monopivot circulatory assist pump. Artif Organs 2009;33:378-86.
    • (2009) Artif Organs , vol.33 , pp. 378-386
    • Nishida, M.1    Maruyama, O.2    Kosaka, R.3
  • 5
    • 59449097747 scopus 로고    scopus 로고
    • Pivot wear of a centrifugal blood pump developed for circulatory assist
    • Yamane T, Nonaka K, Miyoshi H, etal. Pivot wear of a centrifugal blood pump developed for circulatory assist. J Artif Organs 2008;11:232-7.
    • (2008) J Artif Organs , vol.11 , pp. 232-237
    • Yamane, T.1    Nonaka, K.2    Miyoshi, H.3