메뉴 건너뛰기




Volumn 55, Issue 4, 2009, Pages 314-322

Simple in vitro testing method for antithrombogenic evaluation of centrifugal blood pumps

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVATED CLOTTING TIME; ADVANCED INDUSTRIAL SCIENCE AND TECHNOLOGIES; ANIMAL EXPERIMENTS; ANTI-THROMBOGENICITY; CENTRIFUGAL BLOOD PUMP; EX-VIVO; HEMOLYSIS TEST; HYDRODYNAMIC BEARINGS; IN-VITRO; MOCK CIRCULATION SYSTEM; SCREENING TESTS; TESTING METHOD; THROMBUS FORMATION; TRISODIUM CITRATES;

EID: 68849091135     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e3181a7b540     Document Type: Article
Times cited : (17)

References (16)
  • 2
    • 1942517412 scopus 로고    scopus 로고
    • The most profitable use of flow visualization in the elimination of thrombus from a monopivot magnetic suspension blood pump
    • DOI 10.1111/j.1525-1594.2004.47110.x
    • Yamane T, Maruyama O, Nishida M, et al: The most profitable use of flow visualization in the elimination of thrombus from a monopivot magnetic suspension blood pump. Artif Organs 28: 390-397, 2004. (Pubitemid 38526751)
    • (2004) Artificial Organs , vol.28 , Issue.4 , pp. 390-397
    • Yamane, T.1    Maruyama, O.2    Nishida, M.3    Toyoda, M.4    Tsutsui, T.5    Jikuya, T.6    Shigeta, O.7    Sankai, Y.8
  • 3
    • 2542492901 scopus 로고    scopus 로고
    • Flow visualization in a centrifugal blood pump with an eccentric inlet port
    • DOI 10.1111/j.1525-1594.2004.07290.x
    • Yamane T, Kodama T, Yamamoto Y, et al: Flow visualization in a centrifugal blood pump with an eccentric inlet port. Artif Organs 28: 564-570, 2004. (Pubitemid 38692267)
    • (2004) Artificial Organs , vol.28 , Issue.6 , pp. 564-570
    • Yamane, T.1    Kodama, T.2    Yamamoto, Y.3    Shinohara, T.4    Nose, Y.5
  • 4
    • 2542455972 scopus 로고    scopus 로고
    • A comparative study between flow visualization and computational fluid dynamic analysis for the sun medical centrifugal blood pump
    • DOI 10.1111/j.1525-1594.2004.07161.x
    • Yamane T, Miyamoto Y, Tajima K, Yamazaki K: A comparative study between flow visualization and computational fluid dynamic analysis for the sun medical centrifugal blood pump. Artif Organs 28: 458-466, 2004. (Pubitemid 38680159)
    • (2004) Artificial Organs , vol.28 , Issue.5 , pp. 458-466
    • Yamane, T.1    Miyamoto, Y.2    Tajima, K.3    Yamazaki, K.4
  • 5
    • 33644968718 scopus 로고    scopus 로고
    • The pivot wash in two impeller modes for the Balor/Miwatec centrifugal blood pump
    • Yamane T, Kodama T, Nishida M, et al: The pivot wash in two impeller modes for the Balor/Miwatec centrifugal blood pump. Artif Organs 30: 70-73, 2006.
    • (2006) Artif Organs , vol.30 , pp. 70-73
    • Yamane, T.1    Kodama, T.2    Nishida, M.3
  • 9
    • 0024705694 scopus 로고
    • An in vitro test model to study the performance and thrombogenecity of cardiovascular devices
    • Swier P, Bos WJ, Mohammad SF, et al: An in vitro test model to study the performance and thrombogenicity of cardiovascular devices. ASAIO Trans 35: 683-687, 1989. (Pubitemid 20118344)
    • (1989) ASAIO Transactions , vol.35 , Issue.3 , pp. 683-687
    • Swier, P.1    Bos, W.J.2    Mohammad, S.F.3    Olsen, D.B.4    Kolff, W.J.5
  • 12
    • 0030795707 scopus 로고    scopus 로고
    • In vitro thrombogenesis study in the Gyro C1E3 for vibration assessment
    • Nakazawa T, Tayama E, Takami Y, et al: In vitro thrombogenesis study in the Gyro C1E3 for vibration assessment. Artif Organs 21: 714-719, 1997. (Pubitemid 27314414)
    • (1997) Artificial Organs , vol.21 , Issue.7 , pp. 714-719
    • Nakazawa, T.1    Tayama, E.2    Takami, Y.3    Glueck, J.4    Nose, Y.5
  • 13
    • 0023129511 scopus 로고
    • Heparin-protamine complexes in the production of heparin rebound and other complications of extracorporeal bypass procedures
    • Shanberge JN, Murato M, Quattrociocchi-Longe T, Neste LV: Heparin-protamine complexes in the production of heparin rebound and other complications of extracorporeal bypass procedures. Am J Clin Pathol 87: 210-21 7, 1987. (Pubitemid 17022460)
    • (1987) American Journal of Clinical Pathology , vol.87 , Issue.2 , pp. 210-217
    • Shanberge, J.N.1    Murato, M.2    Quattrociocchi-Longe, T.3    Van Neste, L.4
  • 15
    • 0032727699 scopus 로고    scopus 로고
    • Flow visualization analysis for evaluation of shear and recirculation in a new closed-type, monopivot centrifugal blood pump
    • DOI 10.1046/j.1525-1594.1999.06256.x
    • Astalos B, Yamane T, Nishida M: Flow visualization analysis for evaluation of shear and recirculation in a new closed-type, monopivot centrifugal blood pump. Artif Organs 23: 939-946, 1999. (Pubitemid 29496318)
    • (1999) Artificial Organs , vol.23 , Issue.10 , pp. 939-946
    • Asztalos, B.1    Yamane, T.2    Nishida, M.3
  • 16
    • 0031946595 scopus 로고    scopus 로고
    • Washout hole flow measurement for the development of a centrifugal blood pump
    • DOI 10.1046/j.1525-1594.1998.06155.x
    • Nishida M, Yamane T, Astalos B: Washout hole measurement for the development of a centrifugal blood pump. Artif Organs 22: 386-392, 1 998. (Pubitemid 28222297)
    • (1998) Artificial Organs , vol.22 , Issue.5 , pp. 386-392
    • Nishida, M.1    Yamane, T.2    Asztalos, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.