-
1
-
-
0027196457
-
In vivo optical coherence tomography
-
A. F. Fercher, C. K. Hitzenberger, W. Drexler, G. Kamp, and H. Sattmann, "In vivo optical coherence tomography," Am. J. Ophthalmol. 116(1), 113-114 (1993).
-
(1993)
Am. J. Ophthalmol
, vol.116
, Issue.1
, pp. 113-114
-
-
Fercher, A.F.1
Hitzenberger, C.K.2
Drexler, W.3
Kamp, G.4
Sattmann, H.5
-
2
-
-
23044500928
-
Theory, developments and applications of optical coherence tomography
-
P. H. Tomlins and R. K. Wang, "Theory, developments and applications of optical coherence tomography," J. Phys. D Appl. Phys. 38(15), 2519-2535 (2005).
-
(2005)
J. Phys. D Appl. Phys
, vol.38
, Issue.15
, pp. 2519-2535
-
-
Tomlins, P.H.1
Wang, R.K.2
-
3
-
-
1942423868
-
Three-dimensional imaging of the human retina by high-speed optical coherence tomography
-
C. K. Hitzenberger, P. Trost, P. W. Lo, and Q. Y. Zhou, "Three-dimensional imaging of the human retina by high-speed optical coherence tomography," Opt. Express 11(21), 2753-2761 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.21
, pp. 2753-2761
-
-
Hitzenberger, C.K.1
Trost, P.2
Lo, P.W.3
Zhou, Q.Y.4
-
4
-
-
4043126029
-
In vivo video rate optical coherence tomography
-
A. M. Rollins, S. Yazdanfar, M. Kulkarni, R. Ung-Arunyawee, and J. A. Izatt, "In vivo video rate optical coherence tomography," Opt. Express 3(6), 219-229 (1998).
-
(1998)
Opt. Express
, vol.3
, Issue.6
, pp. 219-229
-
-
Rollins, A.M.1
Yazdanfar, S.2
Kulkarni, M.3
Ung-Arunyawee, R.4
Izatt, J.A.5
-
5
-
-
0001936881
-
Measurement of intraocular distances by backscattering spectral interferometry
-
A. F. Fercher, C. K. Hitzenberger, G. Kamp, and S. Y. Elzaiat, "Measurement of intraocular distances by backscattering spectral interferometry," Opt. Commun. 117(1-2), 43-48 (1995).
-
(1995)
Opt. Commun
, vol.117
, Issue.1-2
, pp. 43-48
-
-
Fercher, A.F.1
Hitzenberger, C.K.2
Kamp, G.3
Elzaiat, S.Y.4
-
6
-
-
0031695986
-
Coherence radar and "spectral radar"-new tools for dermatological diagnosis
-
G. Häusler and M. W. Lindner, ""Coherence radar" and "spectral radar"-new tools for dermatological diagnosis," J. Biomed. Opt. 3(1), 21-31 (1998).
-
(1998)
J. Biomed. Opt
, vol.3
, Issue.1
, pp. 21-31
-
-
Häusler, G.1
Lindner, M.W.2
-
7
-
-
0000063301
-
Optical coherence tomography using a frequency-tunable optical source
-
S. R. Chinn, E. A. Swanson, and J. G. Fujimoto, "Optical coherence tomography using a frequency-tunable optical source," Opt. Lett. 22(5), 340-342 (1997).
-
(1997)
Opt. Lett
, vol.22
, Issue.5
, pp. 340-342
-
-
Chinn, S.R.1
Swanson, E.A.2
Fujimoto, J.G.3
-
8
-
-
0002462256
-
Optical coherence tomography of scattering media using frequency-modulated continuous-wave techniques with tunable near-infrared laser
-
U. Haberland, P. Jansen, V. Blazek, and H. J. Schmitt, "Optical coherence tomography of scattering media using frequency-modulated continuous-wave techniques with tunable near-infrared laser," Proc. SPIE 2891, 20-28 (1997).
-
(1997)
Proc. SPIE
, vol.2891
, pp. 20-28
-
-
Haberland, U.1
Jansen, P.2
Blazek, V.3
Schmitt, H.J.4
-
9
-
-
0038618462
-
Performance of fourier domain vs. time domain optical coherence tomography
-
R. Leitgeb, C. K. Hitzenberger, and A. F. Fercher, "Performance of fourier domain vs. time domain optical coherence tomography," Opt. Express 11(8), 889-894 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.8
, pp. 889-894
-
-
Leitgeb, R.1
Hitzenberger, C.K.2
Fercher, A.F.3
-
10
-
-
0242301675
-
Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
-
J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, "Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography," Opt. Lett. 28(21), 2067-2069 (2003).
-
(2003)
Opt. Lett
, vol.28
, Issue.21
, pp. 2067-2069
-
-
de Boer, J.F.1
Cense, B.2
Park, B.H.3
Pierce, M.C.4
Tearney, G.J.5
Bouma, B.E.6
-
11
-
-
2942703878
-
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
-
M. Choma, M. Sarunic, C. Yang, and J. Izatt, "Sensitivity advantage of swept source and Fourier domain optical coherence tomography," Opt. Express 11(18), 2183-2189 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.18
, pp. 2183-2189
-
-
Choma, M.1
Sarunic, M.2
Yang, C.3
Izatt, J.4
-
12
-
-
2942701942
-
Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography
-
B. Cense, N. Nassif, T. Chen, M. Pierce, S.-H. Yun, B. Park, B. Bouma, G. Tearney, and J. de Boer, "Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography," Opt. Express 12(11), 2435-2447 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.11
, pp. 2435-2447
-
-
Cense, B.1
Nassif, N.2
Chen, T.3
Pierce, M.4
Yun, S.-H.5
Park, B.6
Bouma, B.7
Tearney, G.8
de Boer, J.9
-
13
-
-
53449100805
-
In vivo three-dimensional imaging of neovascular age-related macular degeneration using optical frequency domain imaging at 1050 nm
-
D. M. de Bruin, D. L. Burnes, J. Loewenstein, Y. Chen, S. Chang, T. C. Chen, D. D. Esmaili, and J. F. de Boer, "In vivo three-dimensional imaging of neovascular age-related macular degeneration using optical frequency domain imaging at 1050 nm," Invest. Ophthalmol. Vis. Sci. 49(10), 4545-4552 (2008).
-
(2008)
Invest. Ophthalmol. Vis. Sci
, vol.49
, Issue.10
, pp. 4545-4552
-
-
de Bruin, D.M.1
Burnes, D.L.2
Loewenstein, J.3
Chen, Y.4
Chang, S.5
Chen, T.C.6
Esmaili, D.D.7
de Boer, J.F.8
-
14
-
-
33646552709
-
In vivo optical frequency domain imaging of human retina and choroid
-
E. C. Lee, J. F. de Boer, M. Mujat, H. Lim, and S. H. Yun, "In vivo optical frequency domain imaging of human retina and choroid," Opt. Express 14(10), 4403-4411 (2006).
-
(2006)
Opt. Express
, vol.14
, Issue.10
, pp. 4403-4411
-
-
Lee, E.C.1
de Boer, J.F.2
Mujat, M.3
Lim, H.4
Yun, S.H.5
-
15
-
-
33845726046
-
High-speed imaging of human retina in vivo with swept-source optical coherence tomography
-
H. Lim, M. Mujat, C. Kerbage, E. C. Lee, Y. Chen, T. C. Chen, and J. F. de Boer, "High-speed imaging of human retina in vivo with swept-source optical coherence tomography," Opt. Express 14(26), 12902-12908 (2006).
-
(2006)
Opt. Express
, vol.14
, Issue.26
, pp. 12902-12908
-
-
Lim, H.1
Mujat, M.2
Kerbage, C.3
Lee, E.C.4
Chen, Y.5
Chen, T.C.6
de Boer, J.F.7
-
16
-
-
2942726216
-
Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation
-
M. Wojtkowski, V. Srinivasan, T. Ko, J. Fujimoto, A. Kowalczyk, and J. Duker, "Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation," Opt. Express 12(11), 2404-2422 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.11
, pp. 2404-2422
-
-
Wojtkowski, M.1
Srinivasan, V.2
Ko, T.3
Fujimoto, J.4
Kowalczyk, A.5
Duker, J.6
-
17
-
-
2942717185
-
Ultrahigh resolution Fourier domain optical coherence tomography
-
R. A. Leitgeb, W. Drexler, A. Unterhuber, B. Hermann, T. Bajraszewski, T. Le, A. Stingl, and A. F. Fercher, "Ultrahigh resolution Fourier domain optical coherence tomography," Opt. Express 12(10), 2156-2165 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.10
, pp. 2156-2165
-
-
Leitgeb, R.A.1
Drexler, W.2
Unterhuber, A.3
Hermann, B.4
Bajraszewski, T.5
Le, T.6
Stingl, A.7
Fercher, A.F.8
-
18
-
-
33847628411
-
High-speed, high-resolution optical coherence tomography retinal imaging with a frequency-swept laser at 850 nm
-
V. J. Srinivasan, R. Huber, I. Gorczynska, J. G. Fujimoto, J. Y. Jiang, P. Reisen, and A. E. Cable, "High-speed, high-resolution optical coherence tomography retinal imaging with a frequency-swept laser at 850 nm," Opt. Lett. 32(4), 361-363 (2007).
-
(2007)
Opt. Lett
, vol.32
, Issue.4
, pp. 361-363
-
-
Srinivasan, V.J.1
Huber, R.2
Gorczynska, I.3
Fujimoto, J.G.4
Jiang, J.Y.5
Reisen, P.6
Cable, A.E.7
-
19
-
-
33846519303
-
Resonant Doppler flow imaging and optical vivisection of retinal blood vessels
-
A. H. Bachmann, M. L. Villiger, C. Blatter, T. Lasser, and R. A. Leitgeb, "Resonant Doppler flow imaging and optical vivisection of retinal blood vessels," Opt. Express 15(2), 408-422 (2007).
-
(2007)
Opt. Express
, vol.15
, Issue.2
, pp. 408-422
-
-
Bachmann, A.H.1
Villiger, M.L.2
Blatter, C.3
Lasser, T.4
Leitgeb, R.A.5
-
20
-
-
47849098802
-
In vivo volumetric imaging of vascular perfusion within human retina and choroids with optical micro-angiography
-
L. An and R. K. Wang, "In vivo volumetric imaging of vascular perfusion within human retina and choroids with optical micro-angiography," Opt. Express 16(15), 11438-11452 (2008).
-
(2008)
Opt. Express
, vol.16
, Issue.15
, pp. 11438-11452
-
-
An, L.1
Wang, R.K.2
-
21
-
-
70350565505
-
Three-dimensional microscopy of the tumor microenvironment in vivo using optical frequency domain imaging
-
B. J. Vakoc, R. M. Lanning, J. A. Tyrrell, T. P. Padera, L. A. Bartlett, T. Stylianopoulos, L. L. Munn, G. J. Tearney, D. Fukumura, R. K. Jain, and B. E. Bouma, "Three-dimensional microscopy of the tumor microenvironment in vivo using optical frequency domain imaging," Nat. Med. 15(10), 1219-1223 (2009).
-
(2009)
Nat. Med
, vol.15
, Issue.10
, pp. 1219-1223
-
-
Vakoc, B.J.1
Lanning, R.M.2
Tyrrell, J.A.3
Padera, T.P.4
Bartlett, L.A.5
Stylianopoulos, T.6
Munn, L.L.7
Tearney, G.J.8
Fukumura, D.9
Jain, R.K.10
Bouma, B.E.11
-
22
-
-
2942733251
-
In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical coherence tomography
-
B. R. White, M. C. Pierce, N. Nassif, B. Cense, B. H. Park, G. J. Tearney, B. E. Bouma, T. C. Chen, and J. de Boer, "In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical coherence tomography," Opt. Express 11(25), 3490-3497 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.25
, pp. 3490-3497
-
-
White, B.R.1
Pierce, M.C.2
Nassif, N.3
Cense, B.4
Park, B.H.5
Tearney, G.J.6
Bouma, B.E.7
Chen, T.C.8
de Boer, J.9
-
23
-
-
72449129943
-
Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique
-
J. Fingler, R. J. Zawadzki, J. S. Werner, D. Schwartz, and S. E. Fraser, "Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique," Opt. Express 17(24), 22190-22200 (2009).
-
(2009)
Opt. Express
, vol.17
, Issue.24
, pp. 22190-22200
-
-
Fingler, J.1
Zawadzki, R.J.2
Werner, J.S.3
Schwartz, D.4
Fraser, S.E.5
-
24
-
-
77956623680
-
High-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiography
-
L. An, H. M. Subhush, D. J. Wilson, and R. K. Wang, "High-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiography," J. Biomed. Opt. 15(2), 026011 (2010).
-
(2010)
J. Biomed. Opt
, vol.15
, Issue.2
, pp. 026011
-
-
An, L.1
Subhush, H.M.2
Wilson, D.J.3
Wang, R.K.4
-
25
-
-
77953152933
-
Doppler variance imaging for three-dimensional retina and choroid angiography
-
L. Yu and Z. Chen, "Doppler variance imaging for three-dimensional retina and choroid angiography," J. Biomed. Opt. 15(1), 016029 (2010).
-
(2010)
J. Biomed. Opt
, vol.15
, Issue.1
, pp. 016029
-
-
Yu, L.1
Chen, Z.2
-
26
-
-
43049093773
-
Flow velocity estimation using joint spectral and time domain optical coherence tomography
-
M. Szkulmowski, A. Szkulmowska, T. Bajraszewski, A. Kowalczyk, and M. Wojtkowski, "Flow velocity estimation using joint spectral and time domain optical coherence tomography," Opt. Express 16(9), 6008-6025 (2008).
-
(2008)
Opt. Express
, vol.16
, Issue.9
, pp. 6008-6025
-
-
Szkulmowski, M.1
Szkulmowska, A.2
Bajraszewski, T.3
Kowalczyk, A.4
Wojtkowski, M.5
-
27
-
-
77956631054
-
Optical microangiography provides depth-resolved images of directional ocular blood perfusion in posterior eye segment
-
R. K. Wang, L. An, S. Saunders, and D. J. Wilson, "Optical microangiography provides depth-resolved images of directional ocular blood perfusion in posterior eye segment," J. Biomed. Opt. 15(2), 020502 (2010).
-
(2010)
J. Biomed. Opt
, vol.15
, Issue.2
, pp. 020502
-
-
Wang, R.K.1
An, L.2
Saunders, S.3
Wilson, D.J.4
-
28
-
-
78751519380
-
Comprehensive in vivo micro-vascular imaging of the human eye by dual-beam-scan Doppler optical coherence angiography
-
S. Makita, F. Jaillon, M. Yamanari, M. Miura, and Y. Yasuno, "Comprehensive in vivo micro-vascular imaging of the human eye by dual-beam-scan Doppler optical coherence angiography," Opt. Express 19(2), 1271-1283 (2011).
-
(2011)
Opt. Express
, vol.19
, Issue.2
, pp. 1271-1283
-
-
Makita, S.1
Jaillon, F.2
Yamanari, M.3
Miura, M.4
Yasuno, Y.5
-
29
-
-
33747769290
-
Optical coherence angiography
-
S. Makita, Y. Hong, M. Yamanari, T. Yatagai, and Y. Yasuno, "Optical coherence angiography," Opt. Express 14(17), 7821-7840 (2006).
-
(2006)
Opt. Express
, vol.14
, Issue.17
, pp. 7821-7840
-
-
Makita, S.1
Hong, Y.2
Yamanari, M.3
Yatagai, T.4
Yasuno, Y.5
-
30
-
-
77957013968
-
Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second
-
B. Potsaid, B. Baumann, D. Huang, S. Barry, A. E. Cable, J. S. Schuman, J. S. Duker, and J. G. Fujimoto, "Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second," Opt. Express 18(19), 20029-20048 (2010).
-
(2010)
Opt. Express
, vol.18
, Issue.19
, pp. 20029-20048
-
-
Potsaid, B.1
Baumann, B.2
Huang, D.3
Barry, S.4
Cable, A.E.5
Schuman, J.S.6
Duker, J.S.7
Fujimoto, J.G.8
-
31
-
-
79960639422
-
Wavelength swept amplified spontaneous emission source for high speed retinal optical coherence tomography at 1060 nm
-
C. M. Eigenwillig, T. Klein, W. Wieser, B. R. Biedermann, and R. Huber, "Wavelength swept amplified spontaneous emission source for high speed retinal optical coherence tomography at 1060 nm," J Biophotonics 4(7-8), 552-558 (2011).
-
(2011)
J Biophotonics
, vol.4
, Issue.7-8
, pp. 552-558
-
-
Eigenwillig, C.M.1
Klein, T.2
Wieser, W.3
Biedermann, B.R.4
Huber, R.5
-
32
-
-
79951610223
-
Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain mode-locked laser
-
T. Klein, W. Wieser, C. M. Eigenwillig, B. R. Biedermann, and R. Huber, "Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain mode-locked laser," Opt. Express 19(4), 3044-3062 (2011).
-
(2011)
Opt. Express
, vol.19
, Issue.4
, pp. 3044-3062
-
-
Klein, T.1
Wieser, W.2
Eigenwillig, C.M.3
Biedermann, B.R.4
Huber, R.5
-
33
-
-
69049105425
-
Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range
-
M. Gora, K. Karnowski, M. Szkulmowski, B. J. Kaluzny, R. Huber, A. Kowalczyk, and M. Wojtkowski, "Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range," Opt. Express 17(17), 14880-14894 (2009).
-
(2009)
Opt. Express
, vol.17
, Issue.17
, pp. 14880-14894
-
-
Gora, M.1
Karnowski, K.2
Szkulmowski, M.3
Kaluzny, B.J.4
Huber, R.5
Kowalczyk, A.6
Wojtkowski, M.7
-
34
-
-
56149105399
-
Ultrahigh-speed optical coherence tomography for three-dimensional and en face imaging of the retina and optic nerve head
-
V. J. Srinivasan, D. C. Adler, Y. Chen, I. Gorczynska, R. Huber, J. S. Duker, J. S. Schuman, and J. G. Fujimoto, "Ultrahigh-speed optical coherence tomography for three-dimensional and en face imaging of the retina and optic nerve head," Invest. Ophthalmol. Vis. Sci. 49(11), 5103-5110 (2008).
-
(2008)
Invest. Ophthalmol. Vis. Sci
, vol.49
, Issue.11
, pp. 5103-5110
-
-
Srinivasan, V.J.1
Adler, D.C.2
Chen, Y.3
Gorczynska, I.4
Huber, R.5
Duker, J.S.6
Schuman, J.S.7
Fujimoto, J.G.8
-
35
-
-
51849093532
-
Ultrahigh speed spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second
-
B. Potsaid, I. Gorczynska, V. J. Srinivasan, Y. L. Chen, J. Jiang, A. Cable, and J. G. Fujimoto, "Ultrahigh speed spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second," Opt. Express 16(19), 15149-15169 (2008).
-
(2008)
Opt. Express
, vol.16
, Issue.19
, pp. 15149-15169
-
-
Potsaid, B.1
Gorczynska, I.2
Srinivasan, V.J.3
Chen, Y.L.4
Jiang, J.5
Cable, A.6
Fujimoto, J.G.7
-
36
-
-
84856464872
-
In vivo volumetric imaging of human retinal circulation with phase-variance optical coherence tomography
-
D. Y. Kim, J. Fingler, J. S. Werner, D. M. Schwartz, S. E. Fraser, and R. J. Zawadzki, "In vivo volumetric imaging of human retinal circulation with phase-variance optical coherence tomography," Biomed. Opt. Express 2(6), 1504-1513 (2011).
-
(2011)
Biomed. Opt. Express
, vol.2
, Issue.6
, pp. 1504-1513
-
-
Kim, D.Y.1
Fingler, J.2
Werner, J.S.3
Schwartz, D.M.4
Fraser, S.E.5
Zawadzki, R.J.6
-
37
-
-
77954714473
-
Depth-resolved imaging of capillary networks in retina and choroid using ultrahigh sensitive optical microangiography
-
R. K. Wang, L. An, P. Francis, and D. J. Wilson, "Depth-resolved imaging of capillary networks in retina and choroid using ultrahigh sensitive optical microangiography," Opt. Lett. 35(9), 1467-1469 (2010).
-
(2010)
Opt. Lett
, vol.35
, Issue.9
, pp. 1467-1469
-
-
Wang, R.K.1
An, L.2
Francis, P.3
Wilson, D.J.4
-
38
-
-
84863753268
-
High speed spectral domain optical coherence tomography for retinal imaging at 500,000 A-lines per second
-
L. An, P. Li, T. T. Shen, and R. K. Wang, "High speed spectral domain optical coherence tomography for retinal imaging at 500,000 A-lines per second," Biomed. Opt. Express 2(10), 2770-2783 (2011).
-
(2011)
Biomed. Opt. Express
, vol.2
, Issue.10
, pp. 2770-2783
-
-
An, L.1
Li, P.2
Shen, T.T.3
Wang, R.K.4
-
39
-
-
0347933232
-
Optimal wavelength for ultrahigh-resolution optical coherence tomography
-
Y. Wang, J. Nelson, Z. Chen, B. Reiser, R. Chuck, and R. Windeler, "Optimal wavelength for ultrahigh-resolution optical coherence tomography," Opt. Express 11(12), 1411-1417 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.12
, pp. 1411-1417
-
-
Wang, Y.1
Nelson, J.2
Chen, Z.3
Reiser, B.4
Chuck, R.5
Windeler, R.6
-
40
-
-
77952058447
-
Generic real-time uniform K-space sampling method for high-speed swept-source optical coherence tomography
-
J. Xi, L. Huo, J. Li, and X. Li, "Generic real-time uniform K-space sampling method for high-speed swept-source optical coherence tomography," Opt. Express 18(9), 9511-9517 (2010).
-
(2010)
Opt. Express
, vol.18
, Issue.9
, pp. 9511-9517
-
-
Xi, J.1
Huo, L.2
Li, J.3
Li, X.4
-
41
-
-
77954950579
-
Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second
-
W. Wieser, B. R. Biedermann, T. Klein, C. M. Eigenwillig, and R. Huber, "Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second," Opt. Express 18(14), 14685-14704 (2010).
-
(2010)
Opt. Express
, vol.18
, Issue.14
, pp. 14685-14704
-
-
Wieser, W.1
Biedermann, B.R.2
Klein, T.3
Eigenwillig, C.M.4
Huber, R.5
-
42
-
-
51849143798
-
Development of phase-stabilized swept-source OCT for the ultrasensitive quantification of microbubbles
-
R. K. Manapuram, V. G. R. Manne, and K. V. Larin, "Development of phase-stabilized swept-source OCT for the ultrasensitive quantification of microbubbles," Laser Phys. 18(9), 1080-1086 (2008).
-
(2008)
Laser Phys
, vol.18
, Issue.9
, pp. 1080-1086
-
-
Manapuram, R.K.1
Manne, V.G.R.2
Larin, K.V.3
-
43
-
-
80052597258
-
Doppler velocity detection limitations in spectrometer-based versus swept-source optical coherence tomography
-
H. C. Hendargo, R. P. McNabb, A. H. Dhalla, N. Shepherd, and J. A. Izatt, "Doppler velocity detection limitations in spectrometer-based versus swept-source optical coherence tomography," Biomed. Opt. Express 2(8), 2175-2188 (2011).
-
(2011)
Biomed. Opt. Express
, vol.2
, Issue.8
, pp. 2175-2188
-
-
Hendargo, H.C.1
McNabb, R.P.2
Dhalla, A.H.3
Shepherd, N.4
Izatt, J.A.5
-
44
-
-
80053968839
-
Phase-stabilized optical frequency domain imaging at 1-μm for the measurement of blood flow in the human choroid
-
B. Braaf, K. A. Vermeer, V. A. Sicam, E. van Zeeburg, J. C. van Meurs, and J. F. de Boer, "Phase-stabilized optical frequency domain imaging at 1-μm for the measurement of blood flow in the human choroid," Opt. Express 19(21), 20886-20903 (2011).
-
(2011)
Opt. Express
, vol.19
, Issue.21
, pp. 20886-20903
-
-
Braaf, B.1
Vermeer, K.A.2
Sicam, V.A.3
van Zeeburg, E.4
van Meurs, J.C.5
de Boer, J.F.6
-
45
-
-
22744438867
-
Phase-resolved optical frequency domain imaging
-
B. J. Vakoc, S. H. Yun, J. F. de Boer, G. J. Tearney, and B. E. Bouma, "Phase-resolved optical frequency domain imaging," Opt. Express 13(14), 5483-5493 (2005).
-
(2005)
Opt. Express
, vol.13
, Issue.14
, pp. 5483-5493
-
-
Vakoc, B.J.1
Yun, S.H.2
de Boer, J.F.3
Tearney, G.J.4
Bouma, B.E.5
-
46
-
-
25144461753
-
In vivo blood flow imaging by a swept laser source based Fourier domain optical Doppler tomography
-
J. Zhang and Z. Chen, "In vivo blood flow imaging by a swept laser source based Fourier domain optical Doppler tomography," Opt. Express 13(19), 7449-7457 (2005).
-
(2005)
Opt. Express
, vol.13
, Issue.19
, pp. 7449-7457
-
-
Zhang, J.1
Chen, Z.2
-
47
-
-
80053985896
-
Total retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCT
-
B. Baumann, B. Potsaid, M. F. Kraus, J. J. Liu, D. Huang, J. Hornegger, A. E. Cable, J. S. Duker, and J. G. Fujimoto, "Total retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCT," Biomed. Opt. Express 2(6), 1539-1552 (2011).
-
(2011)
Biomed. Opt. Express
, vol.2
, Issue.6
, pp. 1539-1552
-
-
Baumann, B.1
Potsaid, B.2
Kraus, M.F.3
Liu, J.J.4
Huang, D.5
Hornegger, J.6
Cable, A.E.7
Duker, J.S.8
Fujimoto, J.G.9
-
48
-
-
84863015300
-
High-penetration swept source Doppler optical coherence angiography by fully numerical phase stabilization
-
Y. J. Hong, S. Makita, F. Jaillon, M. J. Ju, E. J. Min, B. H. Lee, M. Itoh, M. Miura, and Y. Yasuno, "High-penetration swept source Doppler optical coherence angiography by fully numerical phase stabilization," Opt. Express 20(3), 2740-2760 (2012).
-
(2012)
Opt. Express
, vol.20
, Issue.3
, pp. 2740-2760
-
-
Hong, Y.J.1
Makita, S.2
Jaillon, F.3
Ju, M.J.4
Min, E.J.5
Lee, B.H.6
Itoh, M.7
Miura, M.8
Yasuno, Y.9
-
49
-
-
80455177162
-
Multifunctional imaging of human retina and choroid with 1050-nm spectral domain optical coherence tomography at 92-kHz line scan rate
-
R. K. Wang and L. An, "Multifunctional imaging of human retina and choroid with 1050-nm spectral domain optical coherence tomography at 92-kHz line scan rate," J. Biomed. Opt. 16(5), 050503 (2011).
-
(2011)
J. Biomed. Opt
, vol.16
, Issue.5
, pp. 050503
-
-
Wang, R.K.1
An, L.2
-
51
-
-
0037082056
-
Real-time phase-resolved functional optical coherence tomography by use of optical Hilbert transformation
-
Y. Zhao, Z. Chen, Z. Ding, H. Ren, and J. S. Nelson, "Real-time phase-resolved functional optical coherence tomography by use of optical Hilbert transformation," Opt. Lett. 27(2), 98-100 (2002).
-
(2002)
Opt. Lett
, vol.27
, Issue.2
, pp. 98-100
-
-
Zhao, Y.1
Chen, Z.2
Ding, Z.3
Ren, H.4
Nelson, J.S.5
-
52
-
-
33750533185
-
Real-time flow imaging by removing texture pattern artifacts in spectral-domain optical Doppler tomography
-
R. K. Wang and Z. Ma, "Real-time flow imaging by removing texture pattern artifacts in spectral-domain optical Doppler tomography," Opt. Lett. 31(20), 3001-3003 (2006).
-
(2006)
Opt. Lett
, vol.31
, Issue.20
, pp. 3001-3003
-
-
Wang, R.K.1
Ma, Z.2
-
53
-
-
33749470621
-
Tissue Doppler optical coherence elastography for real time strain rate and strain mapping of soft tissue
-
R. K. Wang, Z. Ma, and S. J. Kirkpatrick, "Tissue Doppler optical coherence elastography for real time strain rate and strain mapping of soft tissue," Appl. Phys. Lett. 89, 3 (2006).
-
(2006)
Appl. Phys. Lett
, vol.89
, pp. 3
-
-
Wang, R.K.1
Ma, Z.2
Kirkpatrick, S.J.3
-
54
-
-
41649089761
-
Photothermal detection of gold nanoparticles using phase-sensitive optical coherence tomography
-
D. C. Adler, S. W. Huang, R. Huber, and J. G. Fujimoto, "Photothermal detection of gold nanoparticles using phase-sensitive optical coherence tomography," Opt. Express 16(7), 4376-4393 (2008).
-
(2008)
Opt. Express
, vol.16
, Issue.7
, pp. 4376-4393
-
-
Adler, D.C.1
Huang, S.W.2
Huber, R.3
Fujimoto, J.G.4
-
55
-
-
79960283281
-
Three-dimensional high-resolution imaging of gold nanorods uptake in sentinel lymph nodes
-
Y. Jung, R. Reif, Y. Zeng, and R. K. Wang, "Three-dimensional high-resolution imaging of gold nanorods uptake in sentinel lymph nodes," Nano Lett. 11(7), 2938-2943 (2011).
-
(2011)
Nano Lett
, vol.11
, Issue.7
, pp. 2938-2943
-
-
Jung, Y.1
Reif, R.2
Zeng, Y.3
Wang, R.K.4
-
56
-
-
79952520284
-
Phase-sensitive optical coherence tomography imaging of the tissue motion within the organ of Corti at a subnanometer scale: A preliminary study
-
R. K. Wang and A. L. Nuttall, "Phase-sensitive optical coherence tomography imaging of the tissue motion within the organ of Corti at a subnanometer scale: a preliminary study," J. Biomed. Opt. 15(5), 056005 (2010).
-
(2010)
J. Biomed. Opt
, vol.15
, Issue.5
, pp. 056005
-
-
Wang, R.K.1
Nuttall, A.L.2
-
57
-
-
1542532020
-
Ocular blood flow and systemic blood pressure in patients with primary open-angle glaucoma and ocular hypertension
-
G. Fuchsjäger-Mayrl, B. Wally, M. Georgopoulos, G. Rainer, K. Kircher, W. Buehl, T. Amoako-Mensah, H. G. Eichler, C. Vass, and L. Schmetterer, "Ocular blood flow and systemic blood pressure in patients with primary open-angle glaucoma and ocular hypertension," Invest. Ophthalmol. Vis. Sci. 45(3), 834-839 (2004).
-
(2004)
Invest. Ophthalmol. Vis. Sci
, vol.45
, Issue.3
, pp. 834-839
-
-
Fuchsjäger-Mayrl, G.1
Wally, B.2
Georgopoulos, M.3
Rainer, G.4
Kircher, K.5
Buehl, W.6
Amoako-Mensah, T.7
Eichler, H.G.8
Vass, C.9
Schmetterer, L.10
-
58
-
-
0026706830
-
Retinal blood flow in diabetic retinopathy
-
V. Patel, S. Rassam, R. Newsom, J. Wiek, and E. Kohner, "Retinal blood flow in diabetic retinopathy," BMJ 305(6855), 678-683 (1992).
-
(1992)
BMJ
, vol.305
, Issue.6855
, pp. 678-683
-
-
Patel, V.1
Rassam, S.2
Newsom, R.3
Wiek, J.4
Kohner, E.5
-
59
-
-
33745066938
-
Retinal haemodynamics in patients with age-related macular degeneration
-
E. Sato, G. T. Feke, M. N. Menke, and J. Wallace McMeel, "Retinal haemodynamics in patients with age-related macular degeneration," Eye (Lond.) 20(6), 697-702 (2006).
-
(2006)
Eye (Lond.)
, vol.20
, Issue.6
, pp. 697-702
-
-
Sato, E.1
Feke, G.T.2
Menke, M.N.3
McMeel, J.W.4
-
60
-
-
58149374694
-
Imaging pulsatile retinal blood flow in human eye
-
B. Rao, L. Yu, H. K. Chiang, L. C. Zacharias, R. M. Kurtz, B. D. Kuppermann, and Z. Chen, "Imaging pulsatile retinal blood flow in human eye," J. Biomed. Opt. 13(4), 040505 (2008).
-
(2008)
J. Biomed. Opt
, vol.13
, Issue.4
, pp. 040505
-
-
Rao, B.1
Yu, L.2
Chiang, H.K.3
Zacharias, L.C.4
Kurtz, R.M.5
Kuppermann, B.D.6
Chen, Z.7
|