메뉴 건너뛰기




Volumn 2, Issue 5-6, 2011, Pages 133-136

Anatomical features of the pronator quadratus muscle related to minimally invasive plate osteosynthesis of distal radial fractures with a volar locking plate: A cadaver study

Author keywords

Distal radius; Fracture; MIPO; Pronator quadratus

Indexed keywords

ADULT; AGED; ANATOMICAL CONCEPTS; ARTICLE; FEMALE; HUMAN; MALE; MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS; MINIMALLY INVASIVE PROCEDURE; MUSCLE CELL; OSTEOSYNTHESIS; QUADRATUS FEMORIS MUSCLE; RADIUS FRACTURE; VOLAR PLATE FIXATION;

EID: 84873177348     PISSN: 18674569     EISSN: 18674577     Source Type: Journal    
DOI: 10.1007/s12570-011-0079-1     Document Type: Article
Times cited : (8)

References (23)
  • 1
    • 0035753023 scopus 로고    scopus 로고
    • Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur
    • Krettek C, Müller M, Miclau T (2001) Evolution of minimally invasive plate osteosynthesis (MIPO) in the femur. Injury 32: 14-23.
    • (2001) Injury , vol.32 , pp. 14-23
    • Krettek, C.1    Müller, M.2    Miclau, T.3
  • 2
    • 68349085791 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated
    • Apivatthakakul T, Chiewcharntanakit S (2009) Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated. Int Orthop 33: 1119-1126.
    • (2009) Int Orthop , vol.33 , pp. 1119-1126
    • Apivatthakakul, T.1    Chiewcharntanakit, S.2
  • 3
    • 33747096914 scopus 로고    scopus 로고
    • Minimally invasive locking plate osteosynthesis for fractures of the distal tibia-results in 20 patients
    • Hazarika S, Chakravarthy J, Cooper J (2006) Minimally invasive locking plate osteosynthesis for fractures of the distal tibia-results in 20 patients. Injury 37: 877-887.
    • (2006) Injury , vol.37 , pp. 877-887
    • Hazarika, S.1    Chakravarthy, J.2    Cooper, J.3
  • 4
    • 34447295639 scopus 로고    scopus 로고
    • Minimally invasive plating of high-energy metaphyseal distal tibia fractures
    • Collinge C, Kuper M, Larson K, Protzman R (2007) Minimally invasive plating of high-energy metaphyseal distal tibia fractures. J Orthop Traoma 21: 355-361.
    • (2007) J Orthop Traoma , vol.21 , pp. 355-361
    • Collinge, C.1    Kuper, M.2    Larson, K.3    Protzman, R.4
  • 5
    • 6044229599 scopus 로고    scopus 로고
    • A minimally invasive approach for plate fixation of the proximal humerus
    • Gardner MJ, Griffith MH, Dines JS, Lorich DG (2004) A minimally invasive approach for plate fixation of the proximal humerus. Bull Hosp Jt Dis 62: 18-23.
    • (2004) Bull Hosp Jt Dis , vol.62 , pp. 18-23
    • Gardner, M.J.1    Griffith, M.H.2    Dines, J.S.3    Lorich, D.G.4
  • 6
    • 33750693402 scopus 로고    scopus 로고
    • Vascular implications of minimally invasive plating of proximal humerus fractures
    • Gardner MJ, Voos JE, Wanich T, Helfet DL, Lorich DG (2006) Vascular implications of minimally invasive plating of proximal humerus fractures. J Orthop Trauma 20: 602-607.
    • (2006) J Orthop Trauma , vol.20 , pp. 602-607
    • Gardner, M.J.1    Voos, J.E.2    Wanich, T.3    Helfet, D.L.4    Lorich, D.G.5
  • 7
    • 43249104400 scopus 로고    scopus 로고
    • Percutaneous humeral plating of fractures of the proximal humerus: results of a prospective multicenter clinical trial
    • Laflamme GY, Rouleau DM, Berry GK, Beaumont PH, Reindl R, Harvey EJ (2008) Percutaneous humeral plating of fractures of the proximal humerus: results of a prospective multicenter clinical trial. J Orthop Traoma 22: 153-158.
    • (2008) J Orthop Traoma , vol.22 , pp. 153-158
    • Laflamme, G.Y.1    Rouleau, D.M.2    Berry, G.K.3    Beaumont, P.H.4    Reindl, R.5    Harvey, E.J.6
  • 8
    • 35348908986 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture
    • Lau TW, Leung F, Chan CF, Chow SP (2007) Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture. Int Orthop 31: 657-664.
    • (2007) Int Orthop , vol.31 , pp. 657-664
    • Lau, T.W.1    Leung, F.2    Chan, C.F.3    Chow, S.P.4
  • 9
    • 35148886200 scopus 로고    scopus 로고
    • Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures
    • Zhiquan A, Bingfang Z, Yeming W, Chi Z, Peiyan H (2007) Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures. J Orthop Trauma 21: 628-633.
    • (2007) J Orthop Trauma , vol.21 , pp. 628-633
    • Zhiquan, A.1    Bingfang, Z.2    Yeming, W.3    Chi, Z.4    Peiyan, H.5
  • 10
    • 77949903328 scopus 로고    scopus 로고
    • Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique
    • An Z, Zeng B, He X, Chen Q, Hu S (2010) Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique. Int Orthop 34: 131-135.
    • (2010) Int Orthop , vol.34 , pp. 131-135
    • An, Z.1    Zeng, B.2    He, X.3    Chen, Q.4    Hu, S.5
  • 11
    • 34547813191 scopus 로고    scopus 로고
    • Minimally invasive plating for complex humeral shaft fractures
    • Jiang R, Luo CF, Zeng BF, Mei GH (2007) Minimally invasive plating for complex humeral shaft fractures. Arch Orthop Trauma Surg 127: 531-535.
    • (2007) Arch Orthop Trauma Surg , vol.127 , pp. 531-535
    • Jiang, R.1    Luo, C.F.2    Zeng, B.F.3    Mei, G.H.4
  • 12
    • 77950273998 scopus 로고    scopus 로고
    • Early full range of shoulder and elbow motion is possible after minimally invasive plate osteosynthesis for humeral shaft fractures
    • Kobayashi M, Watanabe Y, Matsushita T (2010) Early full range of shoulder and elbow motion is possible after minimally invasive plate osteosynthesis for humeral shaft fractures. J Orthop Trauma 24: 212-216.
    • (2010) J Orthop Trauma , vol.24 , pp. 212-216
    • Kobayashi, M.1    Watanabe, Y.2    Matsushita, T.3
  • 13
    • 14744293729 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius
    • Imatani J, Noda T, Morito Y, Sato T, Hashizume H, Inoue H (2005) Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius. J Hand Surg Br 30: 220-225.
    • (2005) J Hand Surg Br , vol.30 , pp. 220-225
    • Imatani, J.1    Noda, T.2    Morito, Y.3    Sato, T.4    Hashizume, H.5    Inoue, H.6
  • 14
    • 0036931799 scopus 로고    scopus 로고
    • Condylar stabilizing technique with AO/ASIF distal radius plate for Colles' fracture associated with osteoporosis
    • Kiyoshige Y (2002) Condylar stabilizing technique with AO/ASIF distal radius plate for Colles' fracture associated with osteoporosis. Tech Hand Up Extrem Surg 6: 205-208.
    • (2002) Tech Hand Up Extrem Surg , vol.6 , pp. 205-208
    • Kiyoshige, Y.1
  • 15
    • 15944376849 scopus 로고    scopus 로고
    • Condylar stabilizing technique for intra-articular fracture of the distal radius
    • Kiyoshige Y (2005) Condylar stabilizing technique for intra-articular fracture of the distal radius. Tech Hand Up Extrem Surg 9: 17-20.
    • (2005) Tech Hand Up Extrem Surg , vol.9 , pp. 17-20
    • Kiyoshige, Y.1
  • 16
    • 68349158468 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis for distal radius fractures: surgical technique
    • Tobe M, Mizutani K, Tsubuku Y, Yanagihara Y (2006) Minimally invasive plate osteosynthesis for distal radius fractures: surgical technique. Riv Chir Mano 3: 280-284.
    • (2006) Riv Chir Mano , vol.3 , pp. 280-284
    • Tobe, M.1    Mizutani, K.2    Tsubuku, Y.3    Yanagihara, Y.4
  • 17
    • 41849089691 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach
    • Sen MK, Harvey EJ (2008) Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. Tech Hand Up Extrem Surg 12: 2-6.
    • (2008) Tech Hand Up Extrem Surg , vol.12 , pp. 2-6
    • Sen, M.K.1    Harvey, E.J.2
  • 18
    • 0029731288 scopus 로고    scopus 로고
    • Pronator quadratus revisited
    • Stuart PR (1996) Pronator quadratus revisited. J Hand Surg Br 21: 714-722.
    • (1996) J Hand Surg Br , vol.21 , pp. 714-722
    • Stuart, P.R.1
  • 19
    • 70350566655 scopus 로고    scopus 로고
    • Quantification of pronator quadratus contribution to isometric pronation torque of the forearm
    • McConkey MO, Schwab TD, Travlos A, Oxland TR, Goetz T (2009) Quantification of pronator quadratus contribution to isometric pronation torque of the forearm. J Hand Surg Am 34: 1612-1617.
    • (2009) J Hand Surg Am , vol.34 , pp. 1612-1617
    • McConkey, M.O.1    Schwab, T.D.2    Travlos, A.3    Oxland, T.R.4    Goetz, T.5
  • 20
    • 0025346660 scopus 로고
    • Vascular anatomy of the pronator quadratus muscle-bone flap: a justification for its use with a distally based blood supply
    • Rath S, Hung LK, Leung PC (1990) Vascular anatomy of the pronator quadratus muscle-bone flap: a justification for its use with a distally based blood supply. J Hand Surg Am 15: 630-636.
    • (1990) J Hand Surg Am , vol.15 , pp. 630-636
    • Rath, S.1    Hung, L.K.2    Leung, P.C.3
  • 21
    • 0030729922 scopus 로고    scopus 로고
    • The anatomical basis of the vascularized pronator quadratus pedicled bone graft
    • Lee JC, Lim J, Chacha PB (1997) The anatomical basis of the vascularized pronator quadratus pedicled bone graft. J Hand Surg Br 22: 644-646.
    • (1997) J Hand Surg Br , vol.22 , pp. 644-646
    • Lee, J.C.1    Lim, J.2    Chacha, P.B.3
  • 22
    • 72449188092 scopus 로고    scopus 로고
    • Intraosseous vascularity of the distal radius: anatomy and clinical implications in distal radius fractures
    • Lamas C, Llusa M, Mendez A, Proubasta I, Carrera A, Forcada P (2009) Intraosseous vascularity of the distal radius: anatomy and clinical implications in distal radius fractures. Hand (NY) 4: 418-423.
    • (2009) Hand (NY) , vol.4 , pp. 418-423
    • Lamas, C.1    Llusa, M.2    Mendez, A.3    Proubasta, I.4    Carrera, A.5    Forcada, P.6
  • 23
    • 0017209427 scopus 로고
    • The pronator quadratus in motions and in stabilization of the radius and ulnar at the distal radioulnar joint
    • Johnson RK, Shrewsbury MM (1976) The pronator quadratus in motions and in stabilization of the radius and ulnar at the distal radioulnar joint. J Hand Surg Am 1: 205-209.
    • (1976) J Hand Surg Am , vol.1 , pp. 205-209
    • Johnson, R.K.1    Shrewsbury, M.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.