메뉴 건너뛰기




Volumn 8, Issue 9, 2013, Pages 1094-1098

The Amplatzer™ Cardiac Plug 2 for left atrial appendage occlusion: Novel features and first-in-man experience

Author keywords

Amplatzer cardiac plug; Atrial fibrillation; Left atrial appendage; Stroke

Indexed keywords

ACETYLSALICYLIC ACID; ANTIBIOTIC AGENT; CLOPIDOGREL;

EID: 84873147146     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV8I9A167     Document Type: Article
Times cited : (87)

References (11)
  • 1
    • 68349151861 scopus 로고    scopus 로고
    • Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: A randomised non-inferiority trial
    • PROTECT AF Investigators
    • Holmes DR, Reddy VY, Turi ZG, Doshi SK, Sievert H, Buchbinder M, Mullin CM, Sick P; PROTECT AF Investigators. Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial. Lancet. 2009;374:534-42.
    • (2009) Lancet , vol.374 , pp. 534-542
    • Holmes, D.R.1    Reddy, V.Y.2    Turi, Z.G.3    Doshi, S.K.4    Sievert, H.5    Buchbinder, M.6    Mullin, C.M.7    Sick, P.8
  • 5
    • 77955139218 scopus 로고    scopus 로고
    • Transcatheter closure of the left atrial appendage: Initial experience with the Amplatzer cardiac plug device
    • Rodés-Cabau J, Champagne J, Bernier M. Transcatheter closure of the left atrial appendage: initial experience with the Amplatzer cardiac plug device. Catheter Cardiovasc Interv. 2010;76:186-92.
    • (2010) Catheter Cardiovasc Interv. , vol.76 , pp. 186-192
    • Rodés-Cabau, J.1    Champagne, J.2    Bernier, M.3
  • 7
    • 81455143122 scopus 로고    scopus 로고
    • Thrombus formation after left atrial appendage exclusion using an Amplatzer cardiac plug device
    • Cruz-Gonzalez I, Martín Moreiras J, García E. Thrombus formation after left atrial appendage exclusion using an Amplatzer cardiac plug device. Catheter Cardiovasc Interv. 2011;78:970-3.
    • (2011) Catheter Cardiovasc Interv. , vol.78 , pp. 970-973
    • Cruz-Gonzalez, I.1    Moreiras, J.M.2    García, E.3
  • 8
    • 33845980209 scopus 로고    scopus 로고
    • Catheter-based atrial shunt occlusion, when the going gets even tougher: Editorial comment to use of a straight, side-hole (SSH), delivery sheath for improved delivery of amplatzer ASD occluder
    • DOI 10.1002/ccd.20988
    • Meier B. Catheter-based atrial shunt occlusion, when the going gets even tougher: editorial comment to use of a straight, side-hole (SSH), delivery sheath for improved delivery of Amplatzer ASD occluder. Catheter Cardiovasc Interv. 2007;69:21-2. (Pubitemid 46052586)
    • (2007) Catheterization and Cardiovascular Interventions , vol.69 , Issue.1 , pp. 21-22
    • Meier, B.1
  • 10
    • 84873159609 scopus 로고    scopus 로고
    • Acute safety results from ACP European multicentre post-market observational Study
    • Paris
    • Park JW. Acute safety results from ACP European multicentre post-market observational Study. EuroPCR 2011, Paris.
    • (2011) EuroPCR
    • Park, J.W.1
  • 11
    • 79751531253 scopus 로고    scopus 로고
    • Safety of percutaneous left atrial appendage closure: Results from the Watchman Left Atrial Appendage System for Embolic Protection in Patients with AF (PROTECT AF) clinical trial and the Continued Access Registry
    • Reddy VY, Holmes D, Doshi SK, Neuzil P, Kar S. Safety of percutaneous left atrial appendage closure: results from the Watchman Left Atrial Appendage System for Embolic Protection in Patients with AF (PROTECT AF) clinical trial and the Continued Access Registry. Circulation. 2011;123:417-24.
    • (2011) Circulation , vol.123 , pp. 417-424
    • Reddy, V.Y.1    Holmes, D.2    Doshi, S.K.3    Neuzil, P.4    Kar, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.