메뉴 건너뛰기




Volumn 78, Issue 6, 2011, Pages 970-973

Thrombus formation after left atrial appendage exclusion using an amplatzer cardiac plug device

Author keywords

complications adult cath intervention (COMP); left arterial appendage closure (LAC); thrombus

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; ENOXAPARIN; WARFARIN;

EID: 81455143122     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.23126     Document Type: Article
Times cited : (42)

References (14)
  • 1
    • 0141817929 scopus 로고    scopus 로고
    • Obliteration of the left atrial appendage for prevention of thromboembolism
    • DOI 10.1016/S0735-1097(03)00958-6
    • Halperin JL, Gomberg-Maitland M,. Obliteration of the left atrial appendage for prevention of thromboembolism. J Am Coll Cardiol 2003; 42; 1259-1261. (Pubitemid 37203397)
    • (2003) Journal of the American College of Cardiology , vol.42 , Issue.7 , pp. 1259-1261
    • Halperin, J.L.1    Gomberg-Maitland, M.2
  • 2
    • 28644446215 scopus 로고    scopus 로고
    • Transcatheter occlusion of the left atrial appendage for stroke prevention
    • DOI 10.1586/14779072.3.6.1003
    • Bayard YL, Ostermayer SH, Sievert H,. Transcatheter occlusion of the left atrial appendage for stroke prevention. Expert Rev Cardiovasc Ther 2005; 3: 1003-1008. (Pubitemid 41748367)
    • (2005) Expert Review of Cardiovascular Therapy , vol.3 , Issue.6 , pp. 1003-1008
    • Bayard, Y.L.1    Ostermayer, S.H.2    Sievert, H.3
  • 3
    • 33846585054 scopus 로고    scopus 로고
    • Left atrial appendage exclusion for stroke prevention in patients with nonrheumatic atrial fibrillation
    • DOI 10.1161/01.STR.0000250166.06949.95, PII 0000767020070200100005
    • Onalan O, Crystal E,. Left atrial appendage exclusion for stroke prevention in patients with nonrheumatic atrial fibrillation. Stroke 2007; 38: 624-630. (Pubitemid 46184230)
    • (2007) Stroke , vol.38 , Issue.2 PART 2 , pp. 624-630
    • Onalan, O.1    Crystal, E.2
  • 5
    • 77955139218 scopus 로고    scopus 로고
    • Transcatheter closure of the left atrial appendage: Initial experience with the Amplatzer cardiac plug device
    • Rodés-Cabau J, Champagne J, Bernier M,. Transcatheter closure of the left atrial appendage: Initial experience with the Amplatzer cardiac plug device. Cathet Cardiovasc Interv 2010; 76: 186-192.
    • (2010) Cathet Cardiovasc Interv , vol.76 , pp. 186-192
    • Rodés-Cabau, J.1    Champagne, J.2    Bernier, M.3
  • 7
    • 68349151861 scopus 로고    scopus 로고
    • Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: A randomised non-inferiority trial
    • Holmes DR, Reddy VY, Turi ZG, Doshi SK, Sievert H, Buchbinder M, Mullin CM, Sick P,. Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: A randomised non-inferiority trial. Lancet 2009; 374: 534-542.
    • (2009) Lancet , vol.374 , pp. 534-542
    • Holmes, D.R.1    Reddy, V.Y.2    Turi, Z.G.3    Doshi, S.K.4    Sievert, H.5    Buchbinder, M.6    Mullin, C.M.7    Sick, P.8
  • 12
    • 0031973519 scopus 로고    scopus 로고
    • Thrombus formation on transcatheter ASD occluder device in a patient with coagulation factor XII deficiency
    • DOI 10.1002/(SICI)1097-0304(199801)43:1<81::AID-CCD24>3.0.CO;2-V
    • Gastmann O, Werner GS, Babic U, Figulla H,. Thrombus formation on transcatheter ASD occluder device in a patient with coagulation factor XII deficiency. Cathet Cardiovasc Diagn 1998; 43: 81-83. (Pubitemid 28023984)
    • (1998) Catheterization and Cardiovascular Diagnosis , vol.43 , Issue.1 , pp. 81-83
    • Gastmann, O.1    Werner, G.S.2    Babic, U.U.3    Figulla, H.R.4
  • 14
    • 79751531253 scopus 로고    scopus 로고
    • Safety of percutaneous left atrial appendage closure: Results from the watchman left atrial appendage system for embolic protection in patients with AF (PROTECT AF) clinical trial and the continued access registry
    • Reddy VY, Holmes D, Doshi SK, Neuzil P, Kar S,. Safety of percutaneous left atrial appendage closure: Results from the watchman left atrial appendage system for embolic protection in patients with AF (PROTECT AF) clinical trial and the continued access registry. Circulation 2011; 123: 417-424.
    • (2011) Circulation , vol.123 , pp. 417-424
    • Reddy, V.Y.1    Holmes, D.2    Doshi, S.K.3    Neuzil, P.4    Kar, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.