메뉴 건너뛰기




Volumn 23, Issue 1, 2013, Pages 216-222

Intra-session and inter-day reliability of forearm surface EMG during varying hand grip forces

Author keywords

EMG; Hand grip; ICC; Reliability; SEM

Indexed keywords

ADULT; ARTICLE; CORRELATION COEFFICIENT; ELECTROMYOGRAM; FEMALE; FLEXOR CARPI RADIALIS MUSCLE; FLEXOR CARPI ULNARIS MUSCLE; FLEXOR DIGITORUM SUPERFICIALIS MUSCLE; FLEXOR MUSCLE; FLEXOR POLLICIS LONGUS MUSCLE; FOREARM; GRIP STRENGTH; HUMAN; HUMAN EXPERIMENT; MALE; MEASUREMENT ERROR; MOTOR PERFORMANCE; MUSCLE ISOMETRIC CONTRACTION; MUSCLE STRENGTH; NORMAL HUMAN; PALMARIS LONGUS MUSCLE; PRIORITY JOURNAL; TEST RETEST RELIABILITY;

EID: 84873105623     PISSN: 10506411     EISSN: 18735711     Source Type: Journal    
DOI: 10.1016/j.jelekin.2012.08.011     Document Type: Article
Times cited : (37)

References (22)
  • 1
    • 0032004826 scopus 로고    scopus 로고
    • EMG signal amplitude assessment during abdominal bracing and hollowing
    • Allison G.T., Godfrey P., Robinson G. EMG signal amplitude assessment during abdominal bracing and hollowing. J Electromyogr Kinesiol 1998, 8(1):51-57.
    • (1998) J Electromyogr Kinesiol , vol.8 , Issue.1 , pp. 51-57
    • Allison, G.T.1    Godfrey, P.2    Robinson, G.3
  • 2
    • 67349157069 scopus 로고    scopus 로고
    • Reliability of electromyographic amplitude values of the upper limb muscles during closed kinetic chain exercises with stable and unstable surfaces
    • Araujo R.C., Tucci H.T., de Andrade R., Martins J., Bevilaqua-Grossi D., de Oliveira A.S. Reliability of electromyographic amplitude values of the upper limb muscles during closed kinetic chain exercises with stable and unstable surfaces. J Electromyogr Kinesiol 2009, 19(4):685-694.
    • (2009) J Electromyogr Kinesiol , vol.19 , Issue.4 , pp. 685-694
    • Araujo, R.C.1    Tucci, H.T.2    de Andrade, R.3    Martins, J.4    Bevilaqua-Grossi, D.5    de Oliveira, A.S.6
  • 4
    • 0030867084 scopus 로고    scopus 로고
    • Isometric abduction muscle activation in patients with rotator tendinosis of the shoulder
    • Brox J.I., Roe C., Saugen E., Vollestad N.K. Isometric abduction muscle activation in patients with rotator tendinosis of the shoulder. Arch Phys Med Rehabil 1997, 78(11):1260-1267.
    • (1997) Arch Phys Med Rehabil , vol.78 , Issue.11 , pp. 1260-1267
    • Brox, J.I.1    Roe, C.2    Saugen, E.3    Vollestad, N.K.4
  • 5
    • 34547516845 scopus 로고    scopus 로고
    • Examination of EMG normalisation methods for the study of the posterior and posterolateral neck muscles in healthy controls
    • Burnett A., Green J., Netto K., Rodrigues J. Examination of EMG normalisation methods for the study of the posterior and posterolateral neck muscles in healthy controls. J Electromyogr Kinesiol 2007, 17(5):635-641.
    • (2007) J Electromyogr Kinesiol , vol.17 , Issue.5 , pp. 635-641
    • Burnett, A.1    Green, J.2    Netto, K.3    Rodrigues, J.4
  • 6
    • 16544393195 scopus 로고    scopus 로고
    • Reliability of EMG measurements for trunk muscles during maximal and sub-maximal voluntary isometric contractions in healthy controls and CLBP patients
    • Dankaerts W., O'Sullivan P.B., Burnett A.F., Straker L.M., Danneels L.A. Reliability of EMG measurements for trunk muscles during maximal and sub-maximal voluntary isometric contractions in healthy controls and CLBP patients. J Electromyogr Kinesiol 2004, 14(3):333-342.
    • (2004) J Electromyogr Kinesiol , vol.14 , Issue.3 , pp. 333-342
    • Dankaerts, W.1    O'Sullivan, P.B.2    Burnett, A.F.3    Straker, L.M.4    Danneels, L.A.5
  • 7
    • 0030973129 scopus 로고    scopus 로고
    • The use of surface electromyography in biomechanics
    • De Luca C.J. The use of surface electromyography in biomechanics. J Appl Biomech 1997, 13:135-163.
    • (1997) J Appl Biomech , vol.13 , pp. 135-163
    • De Luca, C.J.1
  • 8
    • 34249740733 scopus 로고    scopus 로고
    • Predictors of perceived effort in the shoulder during load transfer tasks
    • Dickerson C.R., Martin B.J., Chaffin D.B. Predictors of perceived effort in the shoulder during load transfer tasks. Ergonomics 2007, 50(7):1004-1016.
    • (2007) Ergonomics , vol.50 , Issue.7 , pp. 1004-1016
    • Dickerson, C.R.1    Martin, B.J.2    Chaffin, D.B.3
  • 9
    • 0029239818 scopus 로고
    • Evaluation of handgrip force from EMG measurements
    • Duque J., Masset D., Malchaire J. Evaluation of handgrip force from EMG measurements. Appl Ergon 1995, 26(1):61-66.
    • (1995) Appl Ergon , vol.26 , Issue.1 , pp. 61-66
    • Duque, J.1    Masset, D.2    Malchaire, J.3
  • 11
    • 0032147098 scopus 로고    scopus 로고
    • Reproducibility of electromyographic recordings of submaximal concentric and eccentric muscle contractions in humans
    • Finucane S.D., Rafeei T., Kues J., Lamb R.L., Mayhew T.P. Reproducibility of electromyographic recordings of submaximal concentric and eccentric muscle contractions in humans. Electroencephalogr Clin Neurophysiol 1998, 109(4):290-296.
    • (1998) Electroencephalogr Clin Neurophysiol , vol.109 , Issue.4 , pp. 290-296
    • Finucane, S.D.1    Rafeei, T.2    Kues, J.3    Lamb, R.L.4    Mayhew, T.P.5
  • 12
    • 16244419414 scopus 로고    scopus 로고
    • Prediction of handgrip forces using surface EMG of forearm muscles
    • Hoozemans M.J.M., van Dieën J.H. Prediction of handgrip forces using surface EMG of forearm muscles. J Electromyogr Kinesiol 2005, 15(4):358-366.
    • (2005) J Electromyogr Kinesiol , vol.15 , Issue.4 , pp. 358-366
    • Hoozemans, M.J.M.1    van Dieën, J.H.2
  • 13
    • 1842554829 scopus 로고    scopus 로고
    • Test-retest reliability of static EMG scan configural profiling
    • Iacono C.U. Test-retest reliability of static EMG scan configural profiling. Appl Psychophysiol Biofeedback 2004, 29(1):35-50.
    • (2004) Appl Psychophysiol Biofeedback , vol.29 , Issue.1 , pp. 35-50
    • Iacono, C.U.1
  • 14
    • 42949117042 scopus 로고    scopus 로고
    • Reliability of EMG power-spectrum and amplitude of the semitendinosus and biceps femoris muscles during ramp isometric contractions
    • Kellis E., Katis A. Reliability of EMG power-spectrum and amplitude of the semitendinosus and biceps femoris muscles during ramp isometric contractions. J Electromyogr Kinesiol 2008, 18(3):351-358.
    • (2008) J Electromyogr Kinesiol , vol.18 , Issue.3 , pp. 351-358
    • Kellis, E.1    Katis, A.2
  • 15
    • 0032909102 scopus 로고    scopus 로고
    • Reliability of surface electromyographic measurements
    • Kollmitzer J., Ebenbichler G.R., Kopf A. Reliability of surface electromyographic measurements. Clin Neurophysiol 1999, 110(4):725-734.
    • (1999) Clin Neurophysiol , vol.110 , Issue.4 , pp. 725-734
    • Kollmitzer, J.1    Ebenbichler, G.R.2    Kopf, A.3
  • 16
    • 0345549546 scopus 로고    scopus 로고
    • Reliability of electromyographic and torque measures during isometric axial rotation exertions of the trunk
    • Ng J.K., Parnianpour M., Kippers V., Richardson C.A. Reliability of electromyographic and torque measures during isometric axial rotation exertions of the trunk. Clin Neurophysiol 2003, 114(12):2355-2361.
    • (2003) Clin Neurophysiol , vol.114 , Issue.12 , pp. 2355-2361
    • Ng, J.K.1    Parnianpour, M.2    Kippers, V.3    Richardson, C.A.4
  • 17
    • 77951093048 scopus 로고    scopus 로고
    • Reliability and interpretation of single leg stance and maximum voluntary isometric contraction methods of electromyography normalization
    • Norcross M.F., Blackburn J.T., Goerger B.M. Reliability and interpretation of single leg stance and maximum voluntary isometric contraction methods of electromyography normalization. J Electromyogr Kinesiol 2010, 20(3):420-425.
    • (2010) J Electromyogr Kinesiol , vol.20 , Issue.3 , pp. 420-425
    • Norcross, M.F.1    Blackburn, J.T.2    Goerger, B.M.3
  • 18
    • 20444426274 scopus 로고    scopus 로고
    • Repeatability of surface EMG parameters at various isometric contraction levels and during fatigue using bipolar and Laplacian electrode configurations
    • Ollivier K., Portero P., Maisetti O., Hogrel J.Y. Repeatability of surface EMG parameters at various isometric contraction levels and during fatigue using bipolar and Laplacian electrode configurations. J Electromyogr Kinesiol 2005, 15(5):466-473.
    • (2005) J Electromyogr Kinesiol , vol.15 , Issue.5 , pp. 466-473
    • Ollivier, K.1    Portero, P.2    Maisetti, O.3    Hogrel, J.Y.4
  • 19
    • 71349085808 scopus 로고    scopus 로고
    • Reliability and precision of EMG in leg, torso, and arm muscles during running
    • Smoliga J.M., Myers J.B., Redfern M.S., Lephart S.M. Reliability and precision of EMG in leg, torso, and arm muscles during running. J Electromyogr Kinesiol 2010, 20(1):e1-9.
    • (2010) J Electromyogr Kinesiol , vol.20 , Issue.1
    • Smoliga, J.M.1    Myers, J.B.2    Redfern, M.S.3    Lephart, S.M.4
  • 21
    • 77950849319 scopus 로고    scopus 로고
    • Linearity and reliability of the EMG amplitude versus dynamic torque relationships for the superficial quadriceps femoris muscles
    • Stock M.S., Beck T.W., DeFreitas J.M., Dillon M.A. Linearity and reliability of the EMG amplitude versus dynamic torque relationships for the superficial quadriceps femoris muscles. Electromyogr Clin Neurophysiol 2010, 50(2):97-106.
    • (2010) Electromyogr Clin Neurophysiol , vol.50 , Issue.2 , pp. 97-106
    • Stock, M.S.1    Beck, T.W.2    DeFreitas, J.M.3    Dillon, M.A.4
  • 22
    • 15744385505 scopus 로고    scopus 로고
    • Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM
    • Weir J.P. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res 2005, 19(1):231-240.
    • (2005) J Strength Cond Res , vol.19 , Issue.1 , pp. 231-240
    • Weir, J.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.