메뉴 건너뛰기




Volumn 69, Issue 2, 2013, Pages 411-420

Transperineal prostate MR elastography: Initial in vivo results

Author keywords

magnetic resonance elastography; mechanical properties of the prostate; noninvasive in vivo MR imaging; prostate MR elastography

Indexed keywords

DISEASES; FREQUENCY ESTIMATION; HYDRAULIC ACTUATORS; IMAGE ENHANCEMENT; MAGNETIC RESONANCE IMAGING; MAGNETISM; PHANTOMS; RESONANCE; SHEAR FLOW; SHEAR WAVES; UROLOGY;

EID: 84872971059     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24268     Document Type: Article
Times cited : (46)

References (52)
  • 1
    • 0034694715 scopus 로고    scopus 로고
    • Prostate biopsy grading errors: A sampling problem?
    • DOI 10.1002/1097-0215(20001220)90:6<326::AID-IJC3>3.0.CO;2-J
    • King CR, Long JP,. Prostate biopsy grading errors: a sampling problem? Int J Cancer 2000; 90: 326-330. (Pubitemid 32049294)
    • (2000) International Journal of Cancer , vol.90 , Issue.6 , pp. 326-330
    • King, C.R.1    Long, J.P.2
  • 2
    • 37349094329 scopus 로고    scopus 로고
    • Multiparametric magnetic resonance imaging in prostate cancer: Present and future
    • DOI 10.1097/MOU.0b013e3282f19d01, PII 0004230720080100000015
    • Kurhanewicz J, Vigneron D, Carroll P, Coakley F,. Multiparametric magnetic resonance imaging in prostate cancer: present and future. Curr Opin Urol 2008; 18: 71-77. (Pubitemid 350307535)
    • (2008) Current Opinion in Urology , vol.18 , Issue.1 , pp. 71-77
    • Kurhanewicz, J.1    Vigneron, D.2    Carroll, P.3    Coakley, F.4
  • 8
    • 0025806883 scopus 로고
    • Elastography: A quantitative method for imaging the elasticity of biological tissues
    • Ophir J, Cespedes I, Ponnekanti H, Yazdi Y, Li X,. Elastography: a quantitative method for imaging the elasticity of biological tissues. Ultrason Imaging 1991; 13: 111-134.
    • (1991) Ultrason Imaging , vol.13 , pp. 111-134
    • Ophir, J.1    Cespedes, I.2    Ponnekanti, H.3    Yazdi, Y.4    Li, X.5
  • 10
    • 54049085385 scopus 로고    scopus 로고
    • MR elastography of liver fibrosis: Preliminary results comparing spin-echo and echo-planar imaging
    • Huwart L, Salameh N, ter Beek L, Vicaut E, Peeters F, Sinkus R, Van Beers BE,. MR elastography of liver fibrosis: preliminary results comparing spin-echo and echo-planar imaging. Eur Radiol 2008; 18: 2535-2541.
    • (2008) Eur Radiol , vol.18 , pp. 2535-2541
    • Huwart, L.1    Salameh, N.2    Ter Beek, L.3    Vicaut, E.4    Peeters, F.5    Sinkus, R.6    Van Beers, B.E.7
  • 13
  • 14
    • 36949003435 scopus 로고    scopus 로고
    • Noninvasive assessment of the rheological behavior of human organs using multifrequency MR elastography: A study of brain and liver viscoelasticity
    • Klatt D, Hamhaber U, Asbach P, Braun J, Sack I,. Noninvasive assessment of the rheological behavior of human organs using multifrequency MR elastography: a study of brain and liver viscoelasticity. Phys Med Biol 2007; 52: 7281.
    • (2007) Phys Med Biol , vol.52 , pp. 7281
    • Klatt, D.1    Hamhaber, U.2    Asbach, P.3    Braun, J.4    Sack, I.5
  • 17
    • 33751331428 scopus 로고    scopus 로고
    • Three-dimensional analysis of shear wave propagation observed by in vivo magnetic resonance elastography of the brain
    • Hamhaber U, Sack I, Papazoglou S, Rump J, Klatt D, Braun J,. Three-dimensional analysis of shear wave propagation observed by in vivo magnetic resonance elastography of the brain. Acta Biomater 2007; 3: 127-138.
    • (2007) Acta Biomater , vol.3 , pp. 127-138
    • Hamhaber, U.1    Sack, I.2    Papazoglou, S.3    Rump, J.4    Klatt, D.5    Braun, J.6
  • 18
    • 37549034251 scopus 로고    scopus 로고
    • MR elastography of the lung with hyperpolarized 3He
    • McGee KP, Hubmayr RD, Ehman RL,. MR elastography of the lung with hyperpolarized 3He. Magn Reson Med 2008; 59: 14-18.
    • (2008) Magn Reson Med , vol.59 , pp. 14-18
    • McGee, K.P.1    Hubmayr, R.D.2    Ehman, R.L.3
  • 20
    • 62649114456 scopus 로고    scopus 로고
    • MR elastography of the human heart: Noninvasive assessment of myocardial elasticity changes by shear wave amplitude variations
    • Sack I, Rump J, Elgeti T, Samani A, Braun J,. MR elastography of the human heart: noninvasive assessment of myocardial elasticity changes by shear wave amplitude variations. Magn Reson Med 2009; 61: 668-677.
    • (2009) Magn Reson Med , vol.61 , pp. 668-677
    • Sack, I.1    Rump, J.2    Elgeti, T.3    Samani, A.4    Braun, J.5
  • 21
    • 70449393267 scopus 로고    scopus 로고
    • Application of DENSE-MR-elastography to the human heart
    • Robert B, Sinkus R, Gennisson JL, Fink M,. Application of DENSE-MR-elastography to the human heart. Magn Reson Med 2009; 62: 1155-1163.
    • (2009) Magn Reson Med , vol.62 , pp. 1155-1163
    • Robert, B.1    Sinkus, R.2    Gennisson, J.L.3    Fink, M.4
  • 25
    • 79960953801 scopus 로고    scopus 로고
    • A feasibility study of MR elastography in the diagnosis of prostate cancer at 3.0 T
    • Li S, Chen M, Wang W, Zhao W, Wang J, Zhao X, Zhou C,. A feasibility study of MR elastography in the diagnosis of prostate cancer at 3.0 T. Acta Radiol 2011; 52: 354-358.
    • (2011) Acta Radiol , vol.52 , pp. 354-358
    • Li, S.1    Chen, M.2    Wang, W.3    Zhao, W.4    Wang, J.5    Zhao, X.6    Zhou, C.7
  • 29
    • 79251558800 scopus 로고    scopus 로고
    • Transurethral prostate magnetic resonance elastography: Prospective imaging requirements
    • Arani A, Plewes D, Chopra R,. Transurethral prostate magnetic resonance elastography: prospective imaging requirements. Magn Reson Med 2011; 65: 340-349.
    • (2011) Magn Reson Med , vol.65 , pp. 340-349
    • Arani, A.1    Plewes, D.2    Chopra, R.3
  • 32
  • 36
    • 23744431604 scopus 로고    scopus 로고
    • Measurement of tissue mechanical characteristics to distinguish between benign and malignant prostatic disease
    • DOI 10.1016/j.urology.2005.03.017, PII S0090429505003274
    • Phipps S, Yang THJ, Habib FK, Reuben RL, McNeill SA,. Measurement of tissue mechanical characteristics to distinguish between benign and malignant prostatic disease. Urology 2005; 66: 447-450. (Pubitemid 41138122)
    • (2005) Urology , vol.66 , Issue.2 , pp. 447-450
    • Phipps, S.1    Yang, T.H.J.2    Habib, F.K.3    Reuben, R.L.4    McNeill, S.A.5
  • 39
    • 77954963688 scopus 로고    scopus 로고
    • Mechanical property characterization of prostate cancer using a minimally motorized indenter in an ex vivo indentation experiment
    • Ahn B-M, Kim J, Ian L, Rha K-H, Kim H-J,. Mechanical property characterization of prostate cancer using a minimally motorized indenter in an ex vivo indentation experiment. Urology 2010; 76: 1007-1011.
    • (2010) Urology , vol.76 , pp. 1007-1011
    • Ahn, B.-M.1    Kim, J.2    Ian, L.3    Rha, K.-H.4    Kim, H.-J.5
  • 43
    • 81355138898 scopus 로고    scopus 로고
    • The feasibility of endorectal MR elastography for prostate cancer localization
    • Arani A, Plewes D, Krieger A, Chopra R,. The feasibility of endorectal MR elastography for prostate cancer localization. Magn Reson Med 2011; 66: 1649-1657.
    • (2011) Magn Reson Med , vol.66 , pp. 1649-1657
    • Arani, A.1    Plewes, D.2    Krieger, A.3    Chopra, R.4
  • 45
    • 67749095104 scopus 로고    scopus 로고
    • Magnetic resonance elastography in the liver at 3 Tesla using a second harmonic approach
    • Herzka DA, Kotys MS, Sinkus R, Pettigrew RI, Gharib AM,. Magnetic resonance elastography in the liver at 3 Tesla using a second harmonic approach. Magn Reson Med 2009; 62: 284-291.
    • (2009) Magn Reson Med , vol.62 , pp. 284-291
    • Herzka, D.A.1    Kotys, M.S.2    Sinkus, R.3    Pettigrew, R.I.4    Gharib, A.M.5
  • 46
    • 36849035742 scopus 로고    scopus 로고
    • MR elastography of breast lesions: Understanding the solid/liquid duality can improve the specificity of contrast-enhanced MR mammography
    • DOI 10.1002/mrm.21404
    • Sinkus R, Siegmann K, Xydeas T, Tanter M, Claussen C, Fink M,. MR elastography of breast lesions: understanding the solid/liquid duality can improve the specificity of contrast-enhanced MR mammography. Magn Reson Med 2007; 58: 1135-1144. (Pubitemid 350234200)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1135-1144
    • Sinkus, R.1    Siegmann, K.2    Xydeas, T.3    Tanter, M.4    Claussen, C.5    Fink, M.6
  • 48
    • 84947788569 scopus 로고    scopus 로고
    • Reconstruction of Elasticity and Attenuation Maps in Shear Wave Imaging: An Inverse Approach
    • Medical Image Computing and Computer-Assisted Intervention - MICCAI'98
    • Manduca A, Dutt V, Borup DT, Muthupillai R, Ehman RL, Greenleaf JF,. Reconstruction of elasticity and attenuation maps in shear wave imaging: An inverse approach. In, Wells WM, Colchester A, Delp S, eds. Medical Image Computing and Computer-Assisted Interventation-MICCAI'98, vol. 1496. Berlin/Heidelberg, Germany: Springer-Verlag, 1998; p. 606-613. (Pubitemid 128152706)
    • (1998) Lecture Notes in Computer Science , Issue.1496 , pp. 606-613
    • Manduca, A.1    Dutt, V.2    Borup, D.T.3    Muthupillai, R.4    Ehman, R.L.5    Greenleaf, J.F.6
  • 49
    • 0026185137 scopus 로고
    • Phase-contrast MR angiography with reduced acquisition time: New concepts in sequence design
    • Hausmann R, Lewin JS, Laub G,. Phase-contrast MR angiography with reduced acquisition time: new concepts in sequence design. J Magn Reson Imaging 1991; 1: 415-422.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 415-422
    • Hausmann, R.1    Lewin, J.S.2    Laub, G.3
  • 51
    • 0038675123 scopus 로고    scopus 로고
    • Applying the right statistics: Analyses of measurement studies
    • DOI 10.1002/uog.122
    • Bland JM, Altman DG,. Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol 2003; 22: 85-93. (Pubitemid 36886457)
    • (2003) Ultrasound in Obstetrics and Gynecology , vol.22 , Issue.1 , pp. 85-93
    • Bland, J.M.1    Altman, D.G.2
  • 52
    • 84872970085 scopus 로고    scopus 로고
    • Physical Boundary Conditions Reconstruction: A Novel Method to Determine Viscoelastic Parameters from Magnetic Resonance Elastography Data
    • In, Canada, p.
    • Garteiser P, Doblas S, VanBeers BE, Vilgrain V, Sinkus R,. Physical Boundary Conditions Reconstruction: a Novel Method to Determine Viscoelastic Parameters from Magnetic Resonance Elastography Data. In Proceedings of the 19th Annual Meeting of ISMRM, Montreal, Canada, 2011. p. 3382.
    • (2011) Proceedings of the 19th Annual Meeting of ISMRM, Montreal , pp. 3382
    • Garteiser, P.1    Doblas, S.2    Vanbeers, B.E.3    Vilgrain, V.4    Sinkus, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.