메뉴 건너뛰기




Volumn 62, Issue 2, 2009, Pages 284-291

Magnetic resonance elastography in the liver at 3 Tesla using a second harmonic approach

Author keywords

Elastography; Liver fibrosis; Liver stiffness; Magnetic resonance elastography

Indexed keywords

IMAGE CODING; IMAGE SEGMENTATION; MAGNETISM; MEDICAL IMAGING; SIGNAL TO NOISE RATIO; STIFFNESS;

EID: 67749095104     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21956     Document Type: Article
Times cited : (41)

References (14)
  • 3
    • 36849035742 scopus 로고    scopus 로고
    • MR elastography of breast lesions: Understanding the solid/liquid duality can improve the specificity of contrast-enhanced MR mammography
    • Sinkus R, Siegmann K, Xydeas T, Tanter M, Claussen C, Fink M. MR elastography of breast lesions: understanding the solid/liquid duality can improve the specificity of contrast-enhanced MR mammography. Magn Reson Med 2007;58:1135-1144.
    • (2007) Magn Reson Med , vol.58 , pp. 1135-1144
    • Sinkus, R.1    Siegmann, K.2    Xydeas, T.3    Tanter, M.4    Claussen, C.5    Fink, M.6
  • 4
    • 34748861747 scopus 로고    scopus 로고
    • Yin M, Talwalkar JA, Glaser KJ, Manduca A, Grimm RC, Rossman PJ, Fidler JL, Ehman RL. Assessment of hepatic fibrosis with magnetic resonance elastography. Clin Gastroenterol Hepatol 2007;5:1207-1213.e2.
    • Yin M, Talwalkar JA, Glaser KJ, Manduca A, Grimm RC, Rossman PJ, Fidler JL, Ehman RL. Assessment of hepatic fibrosis with magnetic resonance elastography. Clin Gastroenterol Hepatol 2007;5:1207-1213.e2.
  • 7
    • 0031083548 scopus 로고    scopus 로고
    • The intrinsic signal-to-noise ratio in human cardiac imaging at 1.5, 3, and 4 T
    • Wen H, Denison TJ, Singerman RW, Balaban RS. The intrinsic signal-to-noise ratio in human cardiac imaging at 1.5, 3, and 4 T. J Magn Reson 1997;125:65-71.
    • (1997) J Magn Reson , vol.125 , pp. 65-71
    • Wen, H.1    Denison, T.J.2    Singerman, R.W.3    Balaban, R.S.4
  • 9
    • 33846818960 scopus 로고    scopus 로고
    • Fractional encoding of harmonic motions in MR elastography
    • Rump J, Klatt D, Braun J, Warmuth C, Sack I. Fractional encoding of harmonic motions in MR elastography. Magn Reson Med 2007;57:388-395.
    • (2007) Magn Reson Med , vol.57 , pp. 388-395
    • Rump, J.1    Klatt, D.2    Braun, J.3    Warmuth, C.4    Sack, I.5
  • 10
    • 54049085385 scopus 로고    scopus 로고
    • MR elastography of liver fibrosis: Preliminary results comparing spin-echo and echo-planar imaging
    • Huwart L, Salameh N, Ter Beek L, Vicaut E, Peeters F, Sinkus R, Van Beers BE. MR elastography of liver fibrosis: preliminary results comparing spin-echo and echo-planar imaging. Eur Radiol 2008;18:2535-2541.
    • (2008) Eur Radiol , vol.18 , pp. 2535-2541
    • Huwart, L.1    Salameh, N.2    Ter Beek, L.3    Vicaut, E.4    Peeters, F.5    Sinkus, R.6    Van Beers, B.E.7
  • 12
    • 33846930899 scopus 로고    scopus 로고
    • Comparison of motion encoding waveforms for magnetic resonance elastography
    • at
    • Dunn T, Majumdar S. Comparison of motion encoding waveforms for magnetic resonance elastography at 3T. Conf Proc IEEE Eng Med Biol Soc 2005;7:7405-7408.
    • (2005) Conf Proc IEEE Eng Med Biol Soc , vol.7
    • Dunn, T.1    Majumdar, S.2
  • 14
    • 33644501186 scopus 로고    scopus 로고
    • Noninvasive measures of liver fibrosis
    • Rockey DC, Bissell DM. Noninvasive measures of liver fibrosis. Hepatology 2006;43(Suppl 1):S113-S120.
    • (2006) Hepatology , vol.43 , Issue.SUPPL. 1
    • Rockey, D.C.1    Bissell, D.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.