-
2
-
-
35848942605
-
Standards for medical devices in MRI: Present and future
-
DOI 10.1002/jmri.21140
-
Woods TO,. Standards for medical devices in MRI: present and future. J Magn Reson Imaging 2007; 26: 1186-1189. (Pubitemid 350058284)
-
(2007)
Journal of Magnetic Resonance Imaging
, vol.26
, Issue.5
, pp. 1186-1189
-
-
Woods, T.O.1
-
3
-
-
84857105170
-
-
ASTM. West Conshohocken, PA: ASTM International, DOI: 10.1520/F2182-11A, www.astm.org
-
ASTM. Standard F2182-11a, 2011, standard test method for measurement of radio frequency induced heating on or near passive implants during magnetic resonance imaging. West Conshohocken, PA: ASTM International, 2011, DOI: 10.1520/F2182-11A, www.astm.org
-
(2011)
Standard F2182-11a, 2011, Standard Test Method for Measurement of Radio Frequency Induced Heating on or Near Passive Implants during Magnetic Resonance Imaging
-
-
-
4
-
-
84872974103
-
Reference manual for the SEMCAD simulation platform for electromagnetic compatibility, antenna design and dosimetry
-
SEMCAD X. Reference manual for the SEMCAD simulation platform for electromagnetic compatibility, antenna design and dosimetry. SPEAG-Schmid & Partner Engineering.
-
SPEAG - Schmid & Partner Engineering
-
-
Semcad, X.1
-
5
-
-
70249139553
-
Measurement, simulation, and uncertainty during MRI
-
Neufeld E, Kuhn S, Szekely G, Kuster N,. Measurement, simulation, and uncertainty during MRI. Phys Med Biol 2009; 54: 4151-4169.
-
(2009)
Phys Med Biol
, vol.54
, pp. 4151-4169
-
-
Neufeld, E.1
Kuhn, S.2
Szekely, G.3
Kuster, N.4
-
6
-
-
0032079741
-
1-field inhomogeneity of shielded RF coils loaded with the human head
-
DOI 10.1109/10.668756
-
Chen J, Feng Z, Jin JM,. Numerical simulation of SAR and B1-field inhomogeneity of shielded RF coils loaded with the human head. IEEE Trans Biomed Eng 1998; 45: 650-659. (Pubitemid 28212778)
-
(1998)
IEEE Transactions on Biomedical Engineering
, vol.45
, Issue.5
, pp. 650-659
-
-
Chen, J.1
Feng, Z.2
Jin, J.-M.3
-
8
-
-
77950445055
-
Analysis of the role of lead resistivity in specific absorption rate for deep brain stimulator leads at 3T MRI
-
Angelone LM, Ahveninen J, Belliveau JW, Bonmassar G,. Analysis of the role of lead resistivity in specific absorption rate for deep brain stimulator leads at 3T MRI. IEEE Trans Med Imaging 2010; 29: 1029-1038.
-
(2010)
IEEE Trans Med Imaging
, vol.29
, pp. 1029-1038
-
-
Angelone, L.M.1
Ahveninen, J.2
Belliveau, J.W.3
Bonmassar, G.4
-
9
-
-
84870353821
-
Numerical simulation of SAR induced around Co-Cr-Mo hip prostheses in situ exposed to RF fields associated with 1.5- and 3-T MRI body coils
-
[Epub ahead of print].
-
Powell J, Papadaki A, Hand J, Hart A, McRobbie D,. Numerical simulation of SAR induced around Co-Cr-Mo hip prostheses in situ exposed to RF fields associated with 1.5- and 3-T MRI body coils. Magn Reson Med 2011 [Epub ahead of print].
-
(2011)
Magn Reson Med
-
-
Powell, J.1
Papadaki, A.2
Hand, J.3
Hart, A.4
McRobbie, D.5
-
10
-
-
73349094324
-
Experimental and numerical assessment of MRI-induced temperature change and SAR distributions in phantoms and in vivo
-
Oh S, Webb AG, Neuberger T, Park B, Collins CM,. Experimental and numerical assessment of MRI-induced temperature change and SAR distributions in phantoms and in vivo. Magn Reson Med 2010; 63: 218-223.
-
(2010)
Magn Reson Med
, vol.63
, pp. 218-223
-
-
Oh, S.1
Webb, A.G.2
Neuberger, T.3
Park, B.4
Collins, C.M.5
-
11
-
-
42349090347
-
Complexity of MRI induced heating on metallic leads: Experimental measurements of 374 configurations
-
Mattei E, Triventi M, Calcagnini G, et al. Complexity of MRI induced heating on metallic leads: experimental measurements of 374 configurations. Biomed Eng Online 2008; 7: 11.
-
(2008)
Biomed Eng Online
, vol.7
, pp. 11
-
-
Mattei, E.1
Triventi, M.2
Calcagnini, G.3
|