Volumn 54, Issue 13, 2009, Pages 4151-4169

Measurement, simulation and uncertainty assessment of implant heating during MRI

Author keywords

[No Author keywords available]

Indexed keywords

COMBINED UNCERTAINTY; EXPERIMENTAL ASSESSMENT; INTERLABORATORY COMPARISON; LEAD STRUCTURE; SIMULATIONS AND MEASUREMENTS; UNCERTAINTY ASSESSMENT; UNCERTAINTY BUDGET;

EID: 70249139553     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/54/13/012     Document Type: Article
Times cited : (74)

References (28)
  • 1
    • 70350643306 scopus 로고    scopus 로고
    • American National Standards Institute (ANSI)
    • American National Standards Institute (ANSI) 2003a IEEE recommended practice for determining the peak spatial-average specific absorption rate (SAR) in the human head from wireless communications devices: measurement techniques IEEE Std 1528-2003
    • (2003)
  • 2
    • 70350699039 scopus 로고    scopus 로고
    • American National Standards Institute (ANSI)
    • American National Standards Institute (ANSI) 2003b IEEE recommended practice for determining the peak spatial-average specific absorption rate (SAR) in the human head from wireless communications devices: computational techniques IEEE Std 1529-2003
    • (2003)
  • 3
    • 70350683217 scopus 로고    scopus 로고
    • American Society for Testing Materials (ASTM)
    • American Society for Testing and Materials (ASTM) 2007 Standard test method for measurement of radio frequency induced heating near passive implants during magnetic resonance imaging ASTM International Std F218202a
    • (2007)
  • 4
    • 7544239159 scopus 로고    scopus 로고
    • RF-induced temperature elevation along metallic wires in clinical magnetic resonance imaging: Influence of diameter and length
    • Armenean C, Perrin E, Armenean M, Beuf O, Pilleul F and Saint-Jalmes H 2004 RF-induced temperature elevation along metallic wires in clinical magnetic resonance imaging: influence of diameter and length Magn. Reson. Med. 52 1200-6
    • (2004) Magn. Reson. Med. , vol.52 , Issue.5 , pp. 1200-1206
    • Armenean, C.1    Perrin, E.2    Armenean, M.3    Beuf, O.4    Pilleul, F.5    Saint-Jalmes, H.6
  • 5
    • 33744720336 scopus 로고    scopus 로고
    • MRI-induced heating of selected thin wire metallic implants-laboratory and computational studies-findings and new questions raised
    • Bassen H, Kainz W, Mendoza G and Kellom T 2006 MRI-induced heating of selected thin wire metallic implants-laboratory and computational studies-findings and new questions raised Min. Invas. Therapy 15 76-84
    • (2006) Min. Invas. Therapy , vol.15 , Issue.2 , pp. 76-84
    • Bassen, H.1    Kainz, W.2    Mendoza, G.3    Kellom, T.4
  • 6
    • 28044459877 scopus 로고
    • A perfectly matched layer for the absorption of electromagnetic waves
    • Berenger J P 1994 A perfectly matched layer for the absorption of electromagnetic waves J. Comput. Phys. 114 185-200
    • (1994) J. Comput. Phys. , vol.114 , Issue.2 , pp. 185-200
    • Berenger, J.P.1
  • 7
    • 3042543914 scopus 로고    scopus 로고
    • Biological effects of exposure to magnetic resonance imaging: An overview
    • Formica D and Silvestri S 2004 Biological effects of exposure to magnetic resonance imaging: an overview Biomed. Eng. OnLine 3 11
    • (2004) Biomed. Eng. OnLine , vol.3 , Issue.1 , pp. 11
    • Formica, D.1    Silvestri, S.2
  • 8
    • 0034806846 scopus 로고    scopus 로고
    • Safety of metallic implants in magnetic resonance imaging
    • Ho H S 2001 Safety of metallic implants in magnetic resonance imaging J. Magn. Reson. Imaging 14 472-7
    • (2001) J. Magn. Reson. Imaging , vol.14 , Issue.4 , pp. 472-477
    • Ho, H.S.1
  • 9
    • 70350700336 scopus 로고    scopus 로고
    • Iec AIMD M. R. I.
    • IEC, AIMD MRI compatibility draft ISO 10974 TS V0.6 IEC Standards Department
  • 11
  • 12
    • 70350698950 scopus 로고    scopus 로고
    • Luechinger O 2002 Safety aspects of cardiac pacemakers in magnetic resonance imaging PhD Thesis ETH Zurich, Switzerland http://e-collection.ethbib. ethz.ch/cgi-bin/show.pl?type=diss&nr=14655
    • (2002)
    • Luechinger, O.1
  • 14
    • 34247534258 scopus 로고    scopus 로고
    • Temperature and SAR measurement errors in the evaluation of metallic linear structures heating during MRI using fluoroptic probes
    • Mattei E, Triventi M, Calcagnini G, Censi F, Kainz W, Bassen H I and Bartolini P 2007 Temperature and SAR measurement errors in the evaluation of metallic linear structures heating during MRI using fluoroptic probes Phys. Med. Biol. 52 1633-46
    • (2007) Phys. Med. Biol. , vol.52 , Issue.6 , pp. 1633-1646
    • Mattei, E.1    Triventi, M.2    Calcagnini, G.3    Censi, F.4    Kainz, W.5    Bassen, H.I.6    Bartolini, P.7
  • 15
    • 70350665775 scopus 로고    scopus 로고
    • Simulating the thermal impact of vessels, highly conductive wires and 1-D boundary conditions in FDTD-a unified approach
    • Neufeld E, Cabot E, Chavannes N, Szekely G and Kuster N 2009 Simulating the thermal impact of vessels, highly conductive wires and 1-D boundary conditions in FDTD-a unified approach Phys. Med. Biol. submitted
    • (2009) Phys. Med. Biol.
    • Neufeld, E.1    Cabot, E.2    Chavannes, N.3    Szekely, G.4    Kuster, N.5
  • 17
    • 0035172358 scopus 로고    scopus 로고
    • On the heating of linear conductive structures as guide wires and catheters in interventional MRI
    • Nitz W R, Oppelt A, Renz W, Manke C, Lenhart M and Link J 2001 On the heating of linear conductive structures as guide wires and catheters in interventional MRI J. Magn. Reson. Imaging 13 105-14
    • (2001) J. Magn. Reson. Imaging , vol.13 , Issue.1 , pp. 105-114
    • Nitz, W.R.1    Oppelt, A.2    Renz, W.3    Manke, C.4    Lenhart, M.5    Link, J.6
  • 18
    • 62649135122 scopus 로고    scopus 로고
    • Measuring RF-induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leads
    • Nordbeck P et al 2009 Measuring RF-induced currents inside implants: impact of device configuration on MRI safety of cardiac pacemaker leads Magn. Reson. Med. 61 570-78
    • (2009) Magn. Reson. Med. , vol.61 , Issue.3 , pp. 570-578
    • Nordbeck, P.1
  • 20
    • 35848946812 scopus 로고    scopus 로고
    • Calculation of MRI-induced heating of an implanted medical lead wire with an electric field transfer function
    • Park S M, Kamondetdacha R and Nyenhuis J A 2007 Calculation of MRI-induced heating of an implanted medical lead wire with an electric field transfer function J. Magn. Reson. Imaging 26 1278-85
    • (2007) J. Magn. Reson. Imaging , vol.26 , Issue.5 , pp. 1278-1285
    • Park, S.M.1    Kamondetdacha, R.2    Nyenhuis, J.A.3
  • 22
    • 0141918488 scopus 로고    scopus 로고
    • Gelled versus nongelled phantom material for measurement of MRI-induced temperature increases with bioimplants
    • Park S M et al 2003 Gelled versus nongelled phantom material for measurement of MRI-induced temperature increases with bioimplants IEEE Trans. Magn. 39 3367-71
    • (2003) IEEE Trans. Magn. , vol.39 , Issue.5 , pp. 3367-3371
    • Park, S.M.1
  • 23
    • 70350695658 scopus 로고    scopus 로고
    • SPEAG, SEMCAD X (incl. manual) 2006 Schmid und Partner Engineering AG (SPEAG) Zurich, Switzerland
    • (2006)
  • 25
    • 0036136666 scopus 로고    scopus 로고
    • RF safety of wires in interventional MRI: Using a safety index
    • Yeung C J, Susil R C and Saint-Atalar E 2002a RF safety of wires in interventional MRI: using a safety index Magn. Reson. Med. 47 187-93
    • (2002) Magn. Reson. Med. , vol.47 , Issue.1 , pp. 187-193
    • Yeung, C.J.1    Susil, R.C.2    Saint-Atalar, E.3
  • 26
    • 0036892879 scopus 로고    scopus 로고
    • RF heating due to conductive wires during MRI depends on the phase distribution of the transmit field
    • Yeung C J, Susil R C and Atalar E 2002b RF heating due to conductive wires during MRI depends on the phase distribution of the transmit field Magn. Reson. Med. 48 1096-8
    • (2002) Magn. Reson. Med. , vol.48 , Issue.6 , pp. 1096-1098
    • Yeung, C.J.1    Susil, R.C.2    Atalar, E.3
  • 27
    • 70350689408 scopus 로고    scopus 로고
    • ZAE Bayern 2007a Differential Scanning Calorimetry (DSC) http://www.zae-bayern.de/files/ddk.pdf
    • (2007)
    • Bayern, Z.A.E.1
  • 28
    • 70350653422 scopus 로고    scopus 로고
    • ZAE Bayern 2007b Hot-wire method http://www.zae-bayern.de/files/ hitzdraht.pdf
    • (2007)
    • Bayern, Z.A.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.