메뉴 건너뛰기




Volumn 84, Issue 1000, 2011, Pages 335-341

Image quality of multiplanar reconstruction of pulmonary CT scans using adaptive statistical iterative reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ARTIFACT; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST ENHANCEMENT; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; LUNG SCINTISCANNING; LUNG STRUCTURE; NOISE; SCORING SYSTEM; VISUAL ANALOG SCALE;

EID: 79952812090     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/57998586     Document Type: Article
Times cited : (29)

References (21)
  • 1
    • 1642575994 scopus 로고    scopus 로고
    • Comparison of Axial High-Resolution CT and Thin-Section Multiplanar Reformation (MPR) for Diagnosis of Diseases of the Pulmonary Parenchyma: Preliminary Study in 49 Patients
    • DOI 10.1097/00005382-200401000-00004
    • Arakawa H, Sasaka K, Lu WM, Hirayanagi N, Nakajima Y. Comparison of axial high-resolution CT and thin-section multiplanar reformation (MPR) for diagnosis of diseases of the pulmonary parenchyma: preliminary study in 49 patients. J Thorac Imaging 2004;19:24-31. (Pubitemid 38114384)
    • (2004) Journal of Thoracic Imaging , vol.19 , Issue.1 , pp. 24-31
    • Arakawa, H.1    Sasaka, K.2    Lu, W.M.3    Hirayanagi, N.4    Nakajima, Y.5
  • 2
    • 46849106711 scopus 로고    scopus 로고
    • Comparison between coronal reformatted images and direct coronal CT images of the swine lung specimen: Assessment of image quality with 64-detector row CT
    • DOI 10.1259/bjr/63217190
    • Choi EJ, Oh YW, Ham SY, Lee KY, Kang EY. Comparison between coronal reformatted images and direct coronal CT images of the swine lung specimen: assessment of image quality with 64-detector row CT. Br J Radiol 2008;81:463-7. (Pubitemid 351957757)
    • (2008) British Journal of Radiology , vol.81 , Issue.966 , pp. 463-467
    • Choi, E.J.1    Oh, Y.-W.2    Ham, S.Y.3    Lee, K.Y.4    Kang, E.-Y.5
  • 3
    • 0031932289 scopus 로고    scopus 로고
    • Reducing the influence of the partial volume effect on SPECT activity quantitation with 3D modelling of spatial resolution in iterative reconstruction
    • DOI 10.1088/0031-9155/43/2/014, PII S0031915598839948
    • Pretorius PH, King MA, Pan TS, de Vries DJ, Glick SJ, Byrne CL. Reducing the influence of the partial volume effect on SPECT activity quantitation with 3D modelling of spatial resolution in iterative reconstruction. Phys Med Biol 1998;43:407-20. (Pubitemid 28100141)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.2 , pp. 407-420
    • Pretorius, P.H.1    King, M.A.2    Pan, T.-S.3    De Vries, D.J.4    Glick, S.J.5    Byrne, C.L.6
  • 5
    • 0029934050 scopus 로고    scopus 로고
    • A new iterative reconstruction technique for attenuation correction in high-resolution positron emission tomography
    • DOI 10.1007/BF00834527
    • Knesaurek K, Machac J, Vallabhajosula S, Buchsbaum MS. A new iterative reconstruction technique for attenuation correction in high-resolution positron emission tomography. Eur J Nucl Med 1996;23:656-61. (Pubitemid 26187214)
    • (1996) European Journal of Nuclear Medicine , vol.23 , Issue.6 , pp. 656-661
    • Knesaurek, K.1    Machac, J.2    Vallabhajosula, S.3    Buchsbaum, M.S.4
  • 7
    • 0002129849 scopus 로고
    • Preparation of inflated lung specimens
    • Heitzman ER, editor. 3rd edn. St. Louis, MO: Mosby
    • Markarian B, Dailey ET. Preparation of inflated lung specimens. In: Heitzman ER, editor. The lung: radiologic-pathologic correlations, 3rd edn. St. Louis, MO: Mosby, 1993: 4-12.
    • (1993) The Lung: Radiologic-pathologic Correlations , pp. 4-12
    • Markarian, B.1    Dailey, E.T.2
  • 8
    • 40049100060 scopus 로고    scopus 로고
    • An outlook on x-ray CT research and development
    • DOI 10.1118/1.2836950
    • Wang G, Yu H, De Man B. An outlook on x-ray CT research and development. Med Phys 2008;35:1051-64. (Pubitemid 351322651)
    • (2008) Medical Physics , vol.35 , Issue.3 , pp. 1051-1064
    • Wang, G.1    Yu, H.2    De Man, B.3
  • 9
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • DOI 10.1118/1.2789499
    • Thibault JB, Sauer KD, Bouman CA, Hsieh J. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys 2007;34:4526-44. (Pubitemid 350029675)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4526-4544
    • Thibault, J.-B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 10
    • 0036462553 scopus 로고    scopus 로고
    • Statistical image reconstruction for polyenergetic X-ray computed tomography
    • DOI 10.1109/42.993128, PII S0278006202029361
    • Elbakri IA, Fessler JA. Statistical image reconstruction for polyenergetic X-ray computed tomography. IEEE Trans Med Imaging 2002;21:89-99. (Pubitemid 34466423)
    • (2002) IEEE Transactions on Medical Imaging , vol.21 , Issue.2 , pp. 89-99
    • Elbakri, I.A.1    Fessler, J.A.2
  • 11
    • 74749087439 scopus 로고    scopus 로고
    • Innovations in CT dose reduction strategy: Application of the adaptive statistical iterative reconstruction algorithm
    • Silva AC, Lawder HJ, Hara A, Kujak J, Pavlicek W. Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol 2010;194:191-9.
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 191-199
    • Silva, A.C.1    Lawder, H.J.2    Hara, A.3    Kujak, J.4    Pavlicek, W.5
  • 13
    • 77949865226 scopus 로고    scopus 로고
    • Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique
    • Prakash P, Kalra MK, Kambadakone AK, Pien H, Hsieh J, Blake MA, et al. Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique. Invest Radiol 2010;45:202-10.
    • (2010) Invest Radiol , vol.45 , pp. 202-210
    • Prakash, P.1    Kalra, M.K.2    Kambadakone, A.K.3    Pien, H.4    Hsieh, J.5    Blake, M.A.6
  • 14
    • 76449091107 scopus 로고    scopus 로고
    • Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: Initial experience
    • Prakash P, Kalra MK, Digumarthy SR, Hsieh J, Pien H, Singh S, et al. Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience. J Comput Assist Tomogr 2010;34:40-5.
    • (2010) J Comput Assist Tomogr , vol.34 , pp. 40-45
    • Prakash, P.1    Kalra, M.K.2    Digumarthy, S.R.3    Hsieh, J.4    Pien, H.5    Singh, S.6
  • 15
    • 67649391776 scopus 로고    scopus 로고
    • High-definition multidetector computed tomography for evaluation of coronary artery stents: Comparison to standard-definition 64-detector row computed tomography
    • Min JK, Swaminathan RV, Vass M, Gallagher S, Weinsaft JW. High-definition multidetector computed tomography for evaluation of coronary artery stents: comparison to standard-definition 64-detector row computed tomography. J Cardiovasc Comput Tomogr 2009;3:246-51.
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 246-251
    • Min, J.K.1    Swaminathan, R.V.2    Vass, M.3    Gallagher, S.4    Weinsaft, J.W.5
  • 16
    • 0023950428 scopus 로고
    • Optimization of computed tomography technique to demonstrate the fine structure of the lung
    • Murata K, Khan A, Rojas KA, Herman PG. Optimization of computed tomography technique to demonstrate the fine structure of the lung. Invest Radiol 1988;23:170-5.
    • (1988) Invest Radiol , vol.23 , pp. 170-175
    • Murata, K.1    Khan, A.2    Rojas, K.A.3    Herman, P.G.4
  • 17
    • 0023220989 scopus 로고
    • High-resolution CT of the lungs: An optimal approach
    • Mayo JR, Webb WR, Gould R, Stein MG, Bass I, Gamsu G, et al. High-resolution CT of the lungs: an optimal approach. Radiology 1987;163:507-10. (Pubitemid 17068935)
    • (1987) Radiology , vol.163 , Issue.2 , pp. 507-510
    • Mayo, J.R.1    Webb, W.R.2    Gould, R.3
  • 18
    • 0024369374 scopus 로고
    • High-spatial-frequency (bone) algorithm improves quality of standard CT of the thorax
    • Zwirewich CV, Terriff B, Müller NL. High-spatial-frequency (bone) algorithm improves quality of standard CT of the thorax. AJR Am J Roentgenol 1989;153:1169-73. (Pubitemid 20006530)
    • (1989) American Journal of Roentgenology , vol.153 , Issue.6 , pp. 1169-1173
    • Zwirewich, C.V.1    Terriff, B.2    Muller, N.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.