메뉴 건너뛰기




Volumn 28, Issue 1, 2013, Pages 551-558

Generation system reliability evaluation incorporating correlations of wind speeds with different distributions

Author keywords

Monte Carlo simulation; power system reliability; probability distribution; wind speed correlation

Indexed keywords

CORRELATION MATRIX; DIFFERENT DISTRIBUTIONS; GAMMA DISTRIBUTION; GENERATION SYSTEMS; LOG-NORMAL; MODEL CORRELATION; MONTE CARLO; MONTE CARLO SIMULATION; POWER SYSTEM RELIABILITY; RELIABILITY EVALUATION; WEIBULL; WIND FARM; WIND SPEED;

EID: 84872874181     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2012.2205410     Document Type: Article
Times cited : (149)

References (24)
  • 1
    • 84872862681 scopus 로고    scopus 로고
    • Global Wind Power Growth Continues To Strengthen
    • Global Wind Power Growth Continues to Strengthen. [Online]. Available: http://www.ewea.org.
  • 2
    • 33947671422 scopus 로고    scopus 로고
    • Aspects of relevance in offshore wind farm reliability assessment
    • DOI 10.1109/TEC.2006.889610, Special Issue on Wind Power
    • N. B. Negra, O. Holmstrom, B. Bak-Jesen, and P. Sorensen, "Aspects of relevance in offshore wind farm reliability assessment," IEEE Trans. Energy Convers., vol. 22, no. 1, pp. 159-166, Mar. 2007. (Pubitemid 46487488)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.1 , pp. 159-166
    • Barberis Negra, N.1    Holmstrom, O.2    Bak-Jensen, B.3    Sorensen, P.4
  • 3
    • 34548030244 scopus 로고    scopus 로고
    • Utility wind integration and operating impact state of the art
    • DOI 10.1109/TPWRS.2007.901598
    • J. C. Smith, M. R. Milligan, E. A. DeMeo, and B. Parsons, "Utility wind integration and operating impact state of the art," IEEE Trans. Power Syst., vol. 22, no. 3, pp. 900-908, Aug. 2007. (Pubitemid 47278349)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.3 , pp. 900-908
    • Smith, J.C.1    Milligan, M.R.2    DeMeo, E.A.3    Parsons, B.4
  • 4
    • 4544255264 scopus 로고    scopus 로고
    • Generating capacity adequacy associated with wind energy
    • Aug.
    • R. Billinton and G. Bai, "Generating capacity adequacy associated with wind energy," IEEE Trans. Power Syst., vol. 19, no. 3, pp. 641-646, Aug. 2004.
    • (2004) IEEE Trans. Power Syst. , vol.19 , Issue.3 , pp. 641-646
    • Billinton, R.1    Bai, G.2
  • 5
    • 40849098849 scopus 로고    scopus 로고
    • Multistate wind energy conversion system models for adequacy assessment of generating systems incorporating wind energy
    • DOI 10.1109/TEC.2006.882415
    • R. Billinton and Y. Gao, "Multistate wind energy conversion system models for adequacy assessment of generating systems incorporating wind energy," IEEE Trans. Energy Convers., vol. 23, no. 1, pp. 163-170, Mar. 2008. (Pubitemid 351392311)
    • (2008) IEEE Transactions on Energy Conversion , vol.23 , Issue.1 , pp. 163-170
    • Billinton, R.1    Gao, Y.2
  • 6
    • 1642310555 scopus 로고    scopus 로고
    • Correlation of wind speed between neighboring measuring stations
    • Jun.
    • D. A. Bechrakis and P. D. Sparis, "Correlation of wind speed between neighboring measuring stations," IEEE Trans. Energy Convers., vol. 19, no. 2, pp. 400-406, Jun. 2004.
    • (2004) IEEE Trans. Energy Convers. , vol.19 , Issue.2 , pp. 400-406
    • Bechrakis, D.A.1    Sparis, P.D.2
  • 7
    • 42549086105 scopus 로고    scopus 로고
    • Spatially correlated wind speed modeling for generation adequacy studies in the UK
    • Tampa, FL
    • M. S. Miranda and R. W. Dunn, "Spatially correlated wind speed modeling for generation adequacy studies in the UK," in Proc. IEEE Power Eng. Soc. General Meeting, Tampa, FL, 2007.
    • (2007) Proc. IEEE Power Eng. Soc. General Meeting
    • Miranda, M.S.1    Dunn, R.W.2
  • 8
    • 77951483601 scopus 로고    scopus 로고
    • Adequacy evaluation of wind farm integration in power generation and transmission systems
    • Apr.
    • S. Zhang, G. Li, and M. Zhou, "Adequacy evaluation of wind farm integration in power generation and transmission systems," in Proc. Int. Conf. Sustainable Power Generation and Supply, Apr. 2009, pp. 1-7.
    • (2009) Proc. Int. Conf. Sustainable Power Generation and Supply , pp. 1-7
    • Zhang, S.1    Li, G.2    Zhou, M.3
  • 9
    • 68749116205 scopus 로고    scopus 로고
    • A review on reliability assessment for wind power
    • Dec.
    • W. Jiang, Z. Yan, and D. Feng, "A review on reliability assessment for wind power," Renew. Sustain. Energy Rev., vol. 13, no. 9, pp. 2485-2494, Dec. 2009.
    • (2009) Renew. Sustain. Energy Rev. , vol.13 , Issue.9 , pp. 2485-2494
    • Jiang, W.1    Yan, Z.2    Feng, D.3
  • 11
    • 33947319093 scopus 로고    scopus 로고
    • Considering load-carrying capability and wind speed correlation of WECS in generation adequacy assessment
    • DOI 10.1109/TEC.2006.875475
    • W. Wangdee and R. Billinton, "Considering load-carrying capability and wind speed correlation of WECS in generation adequacy assessment," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 734-741, Sep. 2006. (Pubitemid 46445162)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 734-741
    • Wangdee, W.1    Billinton, R.2
  • 12
    • 68349135406 scopus 로고    scopus 로고
    • Composite system adequacy assessment incorporating large scale wind energy conversion systems considering wind speed correlation
    • Aug.
    • R. Billinton, Y. Gao, and R. Karki, "Composite system adequacy assessment incorporating large scale wind energy conversion systems considering wind speed correlation," IEEE Trans. Power Syst., vol. 24, no. 3, pp. 1375-1382, Aug. 2009.
    • (2009) IEEE Trans. Power Syst. , vol.24 , Issue.3 , pp. 1375-1382
    • Billinton, R.1    Gao, Y.2    Karki, R.3
  • 13
    • 59449107697 scopus 로고    scopus 로고
    • Considering wind speed correlation of WECS in reliability evaluation using the time-shifting technique
    • Apr.
    • K. Xie and R. Billinton, "Considering wind speed correlation of WECS in reliability evaluation using the time-shifting technique," Elect. Power Syst. Res., vol. 79, no. 4, pp. 687-693, Apr. 2008.
    • (2008) Elect. Power Syst. Res. , vol.79 , Issue.4 , pp. 687-693
    • Xie, K.1    Billinton, R.2
  • 15
    • 77958198848 scopus 로고    scopus 로고
    • Quality of wind speed fitting distributions for the urban area of Palermo, Italy
    • Mar.
    • V. Lo Brano, A. Orioli, G. Ciulla, and S. Culotta, "Quality of wind speed fitting distributions for the urban area of Palermo, Italy," Renew. Energy, vol. 36, no. 3, pp. 1026-1039, Mar. 2011.
    • (2011) Renew. Energy , vol.36 , Issue.3 , pp. 1026-1039
    • Lo Brano, V.1    Orioli, A.2    Ciulla, G.3    Culotta, S.4
  • 16
    • 80052523055 scopus 로고    scopus 로고
    • Estimating wind speed probability distribution using kernel density method
    • Dec.
    • Z. Qin, W. Li, and X. Xiong, "Estimating wind speed probability distribution using kernel density method," Elect. Power Syst. Res., vol. 81, no. 12, pp. 2139-2146, Dec. 2011.
    • (2011) Elect. Power Syst. Res. , vol.81 , Issue.12 , pp. 2139-2146
    • Qin, Z.1    Li, W.2    Xiong, X.3
  • 17
    • 76849110959 scopus 로고    scopus 로고
    • Simulation of correlated wind speed and power variates in wind parks
    • May
    • P. F. Correia and J. M. Ferreira de Jesus, "Simulation of correlated wind speed and power variates in wind parks," Elect. Power Syst. Res., vol. 80, no. 5, pp. 592-598, May 2010.
    • (2010) Elect. Power Syst. Res. , vol.80 , Issue.5 , pp. 592-598
    • Correia, P.F.1    Jesus De Ferreira, J.M.2
  • 19
    • 0026257215 scopus 로고
    • Effect of bus load uncertainty and correlation in composite system adequacy evaluation
    • Nov.
    • W. Li and R. Billinton, "Effect of bus load uncertainty and correlation in composite system adequacy evaluation," IEEE Trans. Power Syst., vol. 6, no. 4, pp. 1522-1529, Nov. 1991.
    • (1991) IEEE Trans. Power Syst. , vol.6 , Issue.4 , pp. 1522-1529
    • Li, W.1    Billinton, R.2
  • 23
    • 84872844090 scopus 로고    scopus 로고
    • The Hourly Wind Speed Data For Each Site In The Period Of 10 Years. [Online]. Available:
    • The Hourly Wind Speed Data for Each Site in the Period of 10 Years. [Online]. Available: http://cdc.cma.gov.cn/shuju/index3. jsp?tpcat= SURF&dsid=SURF-CLI-CHN-MUL-DAY.
  • 24
    • 0018544097 scopus 로고
    • IEEE reliability test system
    • Reliability Test System Task Force Of The Application Of Probability Methods Subcommittee Nov.
    • Reliability Test System Task Force of the Application of Probability Methods Subcommittee, "IEEE reliability test system," IEEE Trans. Power Appl. Syst., vol. PAS-98, no. 6, pp. 2047-2054, Nov. 1979.
    • (1979) IEEE Trans. Power Appl. Syst. , vol.PAS-98 , Issue.6 , pp. 2047-2054


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.