메뉴 건너뛰기




Volumn 69, Issue 1, 2013, Pages 71-81

IR TrueFISP with a golden-ratio-based radial readout: Fast quantification of T1, T2, and proton density

Author keywords

bSSFP; inversion recovery; IR TrueFISP; synthetic image generation; TrueFISP

Indexed keywords

BSSFP; EXPERIMENTAL FACTORS; INVERSION RECOVERY; MAGNETIZATION TRANSFER; MEASUREMENT PROTOCOL; STEADY STATE FREE PRECESSIONS; SYNTHETIC IMAGE GENERATION; TRUEFISP;

EID: 84872862131     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24225     Document Type: Article
Times cited : (97)

References (44)
  • 1
    • 33847701745 scopus 로고    scopus 로고
    • Novel method for rapid, simultaneous T1, T2*, and proton density quantification
    • Warntjes JBM, Dahlqvist O, Lundberg P,. Novel method for rapid, simultaneous T1, T2*, and proton density quantification. Magn Reson Med 2007; 57: 528-537.
    • (2007) Magn Reson Med , vol.57 , pp. 528-537
    • Warntjes, J.B.M.1    Dahlqvist, O.2    Lundberg, P.3
  • 2
    • 49049099802 scopus 로고    scopus 로고
    • Rapid magnetic resonance quantification on the brain: Optimization for clinical usage
    • Warntjes JBM, Leinhard OD, West J, Lundberg P,. Rapid magnetic resonance quantification on the brain: optimization for clinical usage. Magn Reson Med 2008; 60: 320-329.
    • (2008) Magn Reson Med , vol.60 , pp. 320-329
    • Warntjes, J.B.M.1    Leinhard, O.D.2    West, J.3    Lundberg, P.4
  • 3
    • 75749116307 scopus 로고    scopus 로고
    • Quantification of T(2) in the abdomen at 3.0 T using a T(2)-prepared balanced turbo field echo sequence
    • Hoad CL, Cox EF, Gowland PA,. Quantification of T(2) in the abdomen at 3.0 T using a T(2)-prepared balanced turbo field echo sequence. Magn Reson Med 2010; 63: 356-364.
    • (2010) Magn Reson Med , vol.63 , pp. 356-364
    • Hoad, C.L.1    Cox, E.F.2    Gowland, P.A.3
  • 4
    • 77950186524 scopus 로고    scopus 로고
    • Quantitative T2 mapping of knee cartilage: Differentiation of healthy control cartilage and cartilage repair tissue in the knee with unloading - Initial results
    • Mamisch TC, Trattnig S, Quirbach S, Marlovits S, White LM, Welsch GH,. Quantitative T2 mapping of knee cartilage: differentiation of healthy control cartilage and cartilage repair tissue in the knee with unloading-initial results. Radiology 2010; 254: 818-826.
    • (2010) Radiology , vol.254 , pp. 818-826
    • Mamisch, T.C.1    Trattnig, S.2    Quirbach, S.3    Marlovits, S.4    White, L.M.5    Welsch, G.H.6
  • 6
    • 0033045138 scopus 로고    scopus 로고
    • T1 and T2 in the brain of healthy subjects, patients with Parkinson disease, and patients with multiple system atrophy: Relation to iron content
    • Vymazal J, Righini A, Brooks RA, Canesi M, Mariani C, Leonardi M, Pezzoli G,. T1 and T2 in the brain of healthy subjects, patients with Parkinson disease, and patients with multiple system atrophy: relation to iron content. Radiology 1999; 211: 489-495.
    • (1999) Radiology , vol.211 , pp. 489-495
    • Vymazal, J.1    Righini, A.2    Brooks, R.A.3    Canesi, M.4    Mariani, C.5    Leonardi, M.6    Pezzoli, G.7
  • 10
    • 0022547676 scopus 로고
    • Toward an automated analysis system for nuclear magnetic resonance imaging. II. Initial segmentation algorithm
    • O'Donnell M, Gore JC, Adams WJ,. Toward an automated analysis system for nuclear magnetic resonance imaging. II. Initial segmentation algorithm. Med Phys 1986; 13: 293-297.
    • (1986) Med Phys , vol.13 , pp. 293-297
    • O'Donnell, M.1    Gore, J.C.2    Adams, W.J.3
  • 11
    • 0023670197 scopus 로고
    • Optimal pulse sequences for magnetic resonance imaging - Computing accurate T1, T2, and proton density images
    • Iwaoka H, Hirata T, Matsuura H,. Optimal pulse sequences for magnetic resonance imaging-computing accurate T1, T2, and proton density images. IEEE Trans Med Imaging 1987; 6: 360-369.
    • (1987) IEEE Trans Med Imaging , vol.6 , pp. 360-369
    • Iwaoka, H.1    Hirata, T.2    Matsuura, H.3
  • 13
    • 0014732355 scopus 로고
    • Time saving in measurement of NMR and EPR relaxation times
    • Look DC, Locker DR,. Time saving in measurement of NMR and EPR relaxation times. Rev Sci Instrum 1970: 41: 250-251.
    • (1970) Rev Sci Instrum , vol.41 , pp. 250-251
    • Look, D.C.1    Locker, D.R.2
  • 14
    • 0026344888 scopus 로고
    • Practical implementation and optimization of one-shot T1 imaging
    • Kay I, Henkelman RM,. Practical implementation and optimization of one-shot T1 imaging. Magn Reson Med 1991; 22: 414-424.
    • (1991) Magn Reson Med , vol.22 , pp. 414-424
    • Kay, I.1    Henkelman, R.M.2
  • 15
    • 33847803187 scopus 로고
    • Optimal determination of relaxation times of Fourier transform nuclear magnetic resonance. Determination of spin-lattice relaxation times in chemically polarized species
    • Christensen KA, Grant DM, Schulman EM, Walling C,. Optimal determination of relaxation times of Fourier transform nuclear magnetic resonance. Determination of spin-lattice relaxation times in chemically polarized species. J Phys Chem 1974; 78: 1971-1977.
    • (1974) J Phys Chem , vol.78 , pp. 1971-1977
    • Christensen, K.A.1    Grant, D.M.2    Schulman, E.M.3    Walling, C.4
  • 17
    • 33847534249 scopus 로고
    • Effects of diffusion on free precession in nuclear magnetic resonance experiments
    • Carr H, Purcell E,. Effects of diffusion on free precession in nuclear magnetic resonance experiments. Phys Rev 1954; 94: 630-638.
    • (1954) Phys Rev , vol.94 , pp. 630-638
    • Carr, H.1    Purcell, E.2
  • 18
    • 0002899752 scopus 로고
    • Modified spin-echo method for measuring nuclear relaxation times
    • Meiboom S, Gill D,. Modified spin-echo method for measuring nuclear relaxation times. Rev Sci Instrum 1958; 29: 688-691.
    • (1958) Rev Sci Instrum , vol.29 , pp. 688-691
    • Meiboom, S.1    Gill, D.2
  • 19
    • 12144277049 scopus 로고    scopus 로고
    • High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2
    • Deoni SCL, Peters TM, Rutt BK,. High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2. Magn Reson Med 2005; 53: 237-241.
    • (2005) Magn Reson Med , vol.53 , pp. 237-241
    • Deoni, S.C.L.1    Peters, T.M.2    Rutt, B.K.3
  • 22
    • 9244237599 scopus 로고    scopus 로고
    • Towards a single-sequence neurologic magnetic resonance imaging examination: Multiple-contrast images from an IR TrueFISP experiment
    • Gulani V, Schmitt P, Griswold MA, Webb AG, Jakob PM,. Towards a single-sequence neurologic magnetic resonance imaging examination: multiple-contrast images from an IR TrueFISP experiment. Invest Radiol 2004; 39: 767-774.
    • (2004) Invest Radiol , vol.39 , pp. 767-774
    • Gulani, V.1    Schmitt, P.2    Griswold, M.A.3    Webb, A.G.4    Jakob, P.M.5
  • 23
  • 24
    • 0033646318 scopus 로고    scopus 로고
    • K-Space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI
    • Song HK, Dougherty L,. k-Space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI. Magn Reson Med 2000; 44: 825-832.
    • (2000) Magn Reson Med , vol.44 , pp. 825-832
    • Song, H.K.1    Dougherty, L.2
  • 25
    • 0037306521 scopus 로고    scopus 로고
    • Nonuniform fast Fourier transforms using min-max interpolation
    • Fessler JA, Sutton BP,. Nonuniform fast Fourier transforms using min-max interpolation. IEEE Trans Med Imaging 2003; 51: 560-574.
    • (2003) IEEE Trans Med Imaging , vol.51 , pp. 560-574
    • Fessler, J.A.1    Sutton, B.P.2
  • 26
    • 33750633047 scopus 로고    scopus 로고
    • On the origin of apparent low tissue signals in balanced SSFP
    • Bieri O, Scheffler K,. On the origin of apparent low tissue signals in balanced SSFP. Magn Reson Med 2006; 56: 1067-1074.
    • (2006) Magn Reson Med , vol.56 , pp. 1067-1074
    • Bieri, O.1    Scheffler, K.2
  • 27
    • 36349030346 scopus 로고    scopus 로고
    • Optimized balanced steady-state free precession magnetization transfer imaging
    • Bieri O, Scheffler K,. Optimized balanced steady-state free precession magnetization transfer imaging. Magn Reson Med 2007; 58: 511-518.
    • (2007) Magn Reson Med , vol.58 , pp. 511-518
    • Bieri, O.1    Scheffler, K.2
  • 28
    • 51449112832 scopus 로고    scopus 로고
    • Quantitative magnetization transfer imaging using balanced SSFP
    • Gloor M, Scheffler K, Bieri O,. Quantitative magnetization transfer imaging using balanced SSFP. Magn Reson Med 2008; 60: 691-700.
    • (2008) Magn Reson Med , vol.60 , pp. 691-700
    • Gloor, M.1    Scheffler, K.2    Bieri, O.3
  • 29
    • 0036847421 scopus 로고    scopus 로고
    • Optimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequences
    • Hennig J, Speck O, Scheffler K,. Optimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequences. Magn Reson Med 2002; 48: 801-809.
    • (2002) Magn Reson Med , vol.48 , pp. 801-809
    • Hennig, J.1    Speck, O.2    Scheffler, K.3
  • 30
    • 70449371825 scopus 로고    scopus 로고
    • SSFP signal with finite RF pulses
    • Bieri O, Scheffler K,. SSFP signal with finite RF pulses. Magn Reson Med 2009; 62: 1232-1241.
    • (2009) Magn Reson Med , vol.62 , pp. 1232-1241
    • Bieri, O.1    Scheffler, K.2
  • 31
    • 0034060592 scopus 로고    scopus 로고
    • Adaptive reconstruction of phased array MR imagery
    • Walsh DO, Gmitro AF, Marcellin MW,. Adaptive reconstruction of phased array MR imagery. Magn Reson Med 2000; 43: 682-690.
    • (2000) Magn Reson Med , vol.43 , pp. 682-690
    • Walsh, D.O.1    Gmitro, A.F.2    Marcellin, M.W.3
  • 32
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Börnert P, Boesiger P,. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001; 46: 638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Börnert, P.3    Boesiger, P.4
  • 33
    • 79251579662 scopus 로고    scopus 로고
    • Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging
    • Seiberlich N, Ehses P, Duerk J, Gilkeson R, Griswold M,. Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging. Magn Reson Med 2010; 65: 492-505.
    • (2010) Magn Reson Med , vol.65 , pp. 492-505
    • Seiberlich, N.1    Ehses, P.2    Duerk, J.3    Gilkeson, R.4    Griswold, M.5
  • 35
    • 84859708312 scopus 로고    scopus 로고
    • Superbalanced steady state free precession
    • doi: 10.1002/mrm.23122
    • Bieri O,. Superbalanced steady state free precession. Magn Reson Med, 2011. doi: 10.1002/mrm.23122.
    • (2011) Magn Reson Med
    • Bieri, O.1
  • 37
    • 0032831184 scopus 로고    scopus 로고
    • A fast 3D look-locker method for volumetric T1 mapping
    • Henderson E, McKinnon G, Lee TY, Rutt BK,. A fast 3D look-locker method for volumetric T1 mapping. Magn Reson Med 1999; 17: 1163-1171.
    • (1999) Magn Reson Med , vol.17 , pp. 1163-1171
    • Henderson, E.1    McKinnon, G.2    Lee, T.Y.3    Rutt, B.K.4
  • 38
    • 0037240173 scopus 로고    scopus 로고
    • Standardized, reproducible, high resolution global measurements of T1 relaxation metrics in cases of multiple sclerosis
    • Srinivasan R, Henry R, Pelletier D, Nelson S,. Standardized, reproducible, high resolution global measurements of T1 relaxation metrics in cases of multiple sclerosis. AJNR Am J Neuroradiol 2003; 24: 58-67.
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 58-67
    • Srinivasan, R.1    Henry, R.2    Pelletier, D.3    Nelson, S.4
  • 41
    • 0026914023 scopus 로고
    • Practical T2 quantitation for clinical applications
    • Poon CS, Henkelman RM,. Practical T2 quantitation for clinical applications. J Magn Reson Imaging 1992; 2: 541-553.
    • (1992) J Magn Reson Imaging , vol.2 , pp. 541-553
    • Poon, C.S.1    Henkelman, R.M.2
  • 42
    • 79251546469 scopus 로고    scopus 로고
    • An analytical description of balanced steady-state free precession with finite radio-frequency excitation
    • Bieri O,. An analytical description of balanced steady-state free precession with finite radio-frequency excitation. Magn Reson Med 2011; 65: 422-431.
    • (2011) Magn Reson Med , vol.65 , pp. 422-431
    • Bieri, O.1
  • 43
  • 44
    • 3543057674 scopus 로고    scopus 로고
    • Off-resonance effects in the transient response of SSFP sequences
    • Ganter C,. Off-resonance effects in the transient response of SSFP sequences. Magn Reson Med 2004; 52: 368-375.
    • (2004) Magn Reson Med , vol.52 , pp. 368-375
    • Ganter, C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.