메뉴 건너뛰기




Volumn 31, Issue 2, 2013, Pages 278-286

Accuracy of the pulse delay time technique with triple cuff for objective indirect blood pressure measurement

Author keywords

delay time technique; noninvasive blood pressure measurement; pulse transit time technique; triple cuff and pulse delay time technique

Indexed keywords

ADULT; ARTICLE; BLOOD PRESSURE MEASUREMENT; CONTROLLED STUDY; CORRELATION COEFFICIENT; FEMALE; HEART AUSCULTATION; HUMAN; MAJOR CLINICAL STUDY; MALE; MEASUREMENT ACCURACY; PRACTICE GUIDELINE; PRIORITY JOURNAL; TRIPLE CUFF AND PULSE DELAY BLOOD PRESSURE MEASUREMENT;

EID: 84872839917     PISSN: 02636352     EISSN: 14735598     Source Type: Journal    
DOI: 10.1097/HJH.0b013e32835c0e7f     Document Type: Article
Times cited : (7)

References (12)
  • 1
    • 0028243132 scopus 로고
    • Theory of the oscillometric maximum and the systolic and diastolic detection ratios
    • Drzewiecki G, Hood R, Apple H. Theory of the oscillometric maximum and the systolic and diastolic detection ratios. Ann Biomed Eng 1994; 22:88-96.
    • (1994) Ann Biomed Eng , vol.22 , pp. 88-96
    • Drzewiecki, G.1    Hood, R.2    Apple, H.3
  • 2
    • 0020307159 scopus 로고
    • Characterization of the oscillometric method for measuring indirect blood pressure
    • Geddes LA, Voelz M, Combs C, Reiner D, Babbs CF. Characterization of the oscillometric method for measuring indirect blood pressure. Ann Biomed Eng 1982; 10:271-280.
    • (1982) Ann Biomed Eng , vol.10 , pp. 271-280
    • Geddes, L.A.1    Voelz, M.2    Combs, C.3    Reiner, D.4    Babbs, C.F.5
  • 3
    • 0034859672 scopus 로고    scopus 로고
    • A new double cuff sphygmotonometer for accurate blood pressure measurement
    • Tochikubo O, Watanabe J, Hanada K, Miyajima E, Kimura K. A new double cuff sphygmotonometer for accurate blood pressure measurement. Hypertens Res 2001; 24:353-357.
    • (2001) Hypertens Res , vol.24 , pp. 353-357
    • Tochikubo, O.1    Watanabe, J.2    Hanada, K.3    Miyajima, E.4    Kimura, K.5
  • 4
    • 1542648293 scopus 로고    scopus 로고
    • Accuracy and applicability of the Terumo ES-H55 double-cuff sphygmomanometer for hospital use
    • Tochikubo O, Nishijima K, Ohshige K, Kimura K. Accuracy and applicability of the Terumo ES-H55 double-cuff sphygmomanometer for hospital use. Blood Press Monit 2003; 8:203-209.
    • (2003) Blood Press Monit , vol.8 , pp. 203-209
    • Tochikubo, O.1    Nishijima, K.2    Ohshige, K.3    Kimura, K.4
  • 5
    • 0031059674 scopus 로고    scopus 로고
    • A new photo-oscillometric method employing the delta-algorithm for accurate blood pressure measurement
    • Tochikubo O, Kawano Y, Miyajima E, Ishii M. A new photo-oscillometric method employing the delta-algorithm for accurate blood pressure measurement. J Hypertens 1997; 15:147-156.
    • (1997) J Hypertens , vol.15 , pp. 147-156
    • Tochikubo, O.1    Kawano, Y.2    Miyajima, E.3    Ishii, M.4
  • 7
    • 0030221353 scopus 로고    scopus 로고
    • A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement
    • Ursino M, Cristalli C. A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement. IEEE Trans Biomed Eng 1996; 43:761-778.
    • (1996) IEEE Trans Biomed Eng , vol.43 , pp. 761-778
    • Ursino, M.1    Cristalli, C.2
  • 9
    • 0033312562 scopus 로고    scopus 로고
    • Simultaneous application of multiple oscillometric methods for blood pressure measurement in finger
    • Senior Member Atlanta, GA, USA
    • Santić A, Senior Member. Simultaneous application of multiple oscillometric methods for blood pressure measurement in finger. Proceedings of The First Joint BMES/EMBS Conference Serving Humanity Advancing Technology, Atlanta, GA, USA. 1999. pp. 231.
    • (1999) Proceedings of the First Joint BMES/EMBS Conference Serving Humanity Advancing Technology , pp. 231
    • Santić, A.1
  • 11
    • 0035992025 scopus 로고    scopus 로고
    • Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults
    • O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, et al. Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7:3-17.
    • (2002) Blood Press Monit , vol.7 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3    Myers, M.4    Parati, G.5    Staessen, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.