-
1
-
-
0036260633
-
MRI of the lungs using hyperpolarized noble gases
-
Möller HE, Chen XJ, Saam B, Hagspiel KD, Johnson GA, Altes TA, de Lange EE, Kauczor H-U,. MRI of the lungs using hyperpolarized noble gases. Magn Reson Med 2002; 47: 1029-1051.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1029-1051
-
-
Möller, H.E.1
Chen, X.J.2
Saam, B.3
Hagspiel, K.D.4
Johnson, G.A.5
Altes, T.A.6
De Lange, E.E.7
Kauczor, H.-U.8
-
2
-
-
61749083987
-
Changes in regional airflow obstruction over time in the lungs of patients with asthma: Evaluation with 3He MR imaging
-
de Lange EE, Altes TA, Patrie JT, Battiston JJ, Juersivich AP, Mugler JP 3rd, Platts-Mills TA,. Changes in regional airflow obstruction over time in the lungs of patients with asthma: evaluation with 3He MR imaging. Radiology 2009; 250: 567-575.
-
(2009)
Radiology
, vol.250
, pp. 567-575
-
-
De Lange, E.E.1
Altes, T.A.2
Patrie, J.T.3
Battiston, J.J.4
Juersivich, A.P.5
Mugler III, J.P.6
Platts-Mills, T.A.7
-
3
-
-
64349104057
-
The difference in ventilation heterogeneity between asthmatic and healthy subjects quantified using hyperpolarized He-3 MRI
-
Tzeng YS, Lutchen K, Albert M,. The difference in ventilation heterogeneity between asthmatic and healthy subjects quantified using hyperpolarized He-3 MRI. J Appl Physiol 2009; 106: 813-822.
-
(2009)
J Appl Physiol
, vol.106
, pp. 813-822
-
-
Tzeng, Y.S.1
Lutchen, K.2
Albert, M.3
-
4
-
-
51249122850
-
Hyperpolarized 3He magnetic resonance imaging of chronic obstructive pulmonary disease: Reproducibility at 3.0 tesla
-
Mathew L, Evans A, Ouriadov A, Etemad-Rezai R, Fogel R, Santyr G, McCormack DG, Parraga G,. Hyperpolarized 3He magnetic resonance imaging of chronic obstructive pulmonary disease: reproducibility at 3.0 tesla. Acad Radiol 2008; 15: 1298-1311.
-
(2008)
Acad Radiol
, vol.15
, pp. 1298-1311
-
-
Mathew, L.1
Evans, A.2
Ouriadov, A.3
Etemad-Rezai, R.4
Fogel, R.5
Santyr, G.6
McCormack, D.G.7
Parraga, G.8
-
5
-
-
77953937210
-
Chronic obstructive pulmonary disease: Longitudinal hyperpolarized (3)He MR imaging
-
Kirby M, Mathew L, Wheatley A, Santyr GE, McCormack DG, Parraga G,. Chronic obstructive pulmonary disease: longitudinal hyperpolarized (3)He MR imaging. Radiology 2010; 256: 280-289.
-
(2010)
Radiology
, vol.256
, pp. 280-289
-
-
Kirby, M.1
Mathew, L.2
Wheatley, A.3
Santyr, G.E.4
McCormack, D.G.5
Parraga, G.6
-
6
-
-
75149180414
-
Rapid 3-D mapping of hyperpolarized He-3 spin-lattice relaxation times using variable flip angle gradient echo imaging with application to alveolar oxygen partial pressure measurement in rat lungs
-
Ouriadov AV, Lam WW, Santyr GE,. Rapid 3-D mapping of hyperpolarized He-3 spin-lattice relaxation times using variable flip angle gradient echo imaging with application to alveolar oxygen partial pressure measurement in rat lungs. Magn Reson Mater Phys 2009; 22: 309-318.
-
(2009)
Magn Reson Mater Phys
, vol.22
, pp. 309-318
-
-
Ouriadov, A.V.1
Lam, W.W.2
Santyr, G.E.3
-
7
-
-
27244438435
-
Measurements of regional alveolar oxygen pressure using hyperpolarized He-3 MRI
-
Fischer MC, Kadlecek S, Yu JS, Ishii M, Emami K, Vahdat V, Lipson DA, Rizi RR,. Measurements of regional alveolar oxygen pressure using hyperpolarized He-3 MRI. Acad Radiol 2005; 12: 1430-1439.
-
(2005)
Acad Radiol
, vol.12
, pp. 1430-1439
-
-
Fischer, M.C.1
Kadlecek, S.2
Yu, J.S.3
Ishii, M.4
Emami, K.5
Vahdat, V.6
Lipson, D.A.7
Rizi, R.R.8
-
8
-
-
78349256613
-
Measurement of alveolar oxygen partial pressure in the rat lung using Carr-Purcell-Meiboom-Gill spin-spin relaxation times of hyperpolarized 3He and 129Xe at 74 mT
-
Kraayvanger RJ, Bidinosti CP, Dominguez-Viqueira W, Parra-Robles J, Fox M, Lam WW, Santyr GE,. Measurement of alveolar oxygen partial pressure in the rat lung using Carr-Purcell-Meiboom-Gill spin-spin relaxation times of hyperpolarized 3He and 129Xe at 74 mT. Magn Reson Med 2010; 64: 1484-1490.
-
(2010)
Magn Reson Med
, vol.64
, pp. 1484-1490
-
-
Kraayvanger, R.J.1
Bidinosti, C.P.2
Dominguez-Viqueira, W.3
Parra-Robles, J.4
Fox, M.5
Lam, W.W.6
Santyr, G.E.7
-
9
-
-
0344980295
-
Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part I: Diffusion coefficient
-
Chen XJ, Moller HE, Chawla MS, Cofer GP, Driehuys B, Hedlund LW, Johnson GA,. Spatially resolved measurements of hyperpolarized gas properties in the lung in vivo. Part I: diffusion coefficient. Magn Reson Med 1999; 42: 721-728.
-
(1999)
Magn Reson Med
, vol.42
, pp. 721-728
-
-
Chen, X.J.1
Moller, H.E.2
Chawla, M.S.3
Cofer, G.P.4
Driehuys, B.5
Hedlund, L.W.6
Johnson, G.A.7
-
10
-
-
41949094645
-
Hyperpolarized He-3 apparent diffusion coefficient MRI of the lung: Reproducibility and volume dependency in healthy volunteers and patients with emphysema
-
Diaz S, Casselbrant I, Piitulainen E, Pettersson G, Magnusson P, Peterson B, Wollmer P, Leander P, Ekberg O, Akeson P,. Hyperpolarized He-3 apparent diffusion coefficient MRI of the lung: reproducibility and volume dependency in healthy volunteers and patients with emphysema. J Magn Reson Imaging 2008; 27: 763-770.
-
(2008)
J Magn Reson Imaging
, vol.27
, pp. 763-770
-
-
Diaz, S.1
Casselbrant, I.2
Piitulainen, E.3
Pettersson, G.4
Magnusson, P.5
Peterson, B.6
Wollmer, P.7
Leander, P.8
Ekberg, O.9
Akeson, P.10
-
11
-
-
0042311382
-
Helium-3 MRI diffusion coefficient: Correlation to morphometry in a model of mild emphysema
-
Peces-Barba G, Ruiz-Cabello J, Cremillieux Y, Rodriguez I, Dupuich D, Callot V, Ortega M, Rubio Arbo ML, Cortijo M, Gonzalez-Mangado N,. Helium-3 MRI diffusion coefficient: correlation to morphometry in a model of mild emphysema. Eur Respir J 2003; 22: 14-19.
-
(2003)
Eur Respir J
, vol.22
, pp. 14-19
-
-
Peces-Barba, G.1
Ruiz-Cabello, J.2
Cremillieux, Y.3
Rodriguez, I.4
Dupuich, D.5
Callot, V.6
Ortega, M.7
Rubio Arbo, M.L.8
Cortijo, M.9
Gonzalez-Mangado, N.10
-
12
-
-
70349669254
-
Effects of diffusion time on short-range hyperpolarized3He diffusivity measurements in emphysema
-
Gierada DS, Woods JC, Bierhals AJ, Bartel ST, Ritter JH, Choong CK, Das NA, Hong C, Pilgram TK, Chang YV, Jacob RE, Hogg JC, Battafarano RJ, Cooper JD, Meyers BF, Patterson GA, Yablonskiy DA, Conradi MS,. Effects of diffusion time on short-range hyperpolarized3He diffusivity measurements in emphysema. J Magn Reson Imaging 2009; 30: 801-808.
-
(2009)
J Magn Reson Imaging
, vol.30
, pp. 801-808
-
-
Gierada, D.S.1
Woods, J.C.2
Bierhals, A.J.3
Bartel, S.T.4
Ritter, J.H.5
Choong, C.K.6
Das, N.A.7
Hong, C.8
Pilgram, T.K.9
Chang, Y.V.10
Jacob, R.E.11
Hogg, J.C.12
Battafarano, R.J.13
Cooper, J.D.14
Meyers, B.F.15
Patterson, G.A.16
Yablonskiy, D.A.17
Conradi, M.S.18
-
13
-
-
33845247818
-
Hyperpolarized 3He diffusion MRI and histology in pulmonary emphysema
-
Woods JC, Choong CK, Yablonskiy DA, Bentley J, Wong J, Pierce JA, Cooper JD, Macklem PT, Conradi MS, Hogg JC,. Hyperpolarized 3He diffusion MRI and histology in pulmonary emphysema. Magn Reson Med 2006; 56: 1293-1300.
-
(2006)
Magn Reson Med
, vol.56
, pp. 1293-1300
-
-
Woods, J.C.1
Choong, C.K.2
Yablonskiy, D.A.3
Bentley, J.4
Wong, J.5
Pierce, J.A.6
Cooper, J.D.7
MacKlem, P.T.8
Conradi, M.S.9
Hogg, J.C.10
-
14
-
-
0037022621
-
Quantitative in vivo assessment of lung microstructure at the alveolar level with hyperpolarized 3He diffusion MRI
-
Yablonskiy DA,. Quantitative in vivo assessment of lung microstructure at the alveolar level with hyperpolarized 3He diffusion MRI. Proc Natl Acad Sci 2002; 99: 3111-3116.
-
(2002)
Proc Natl Acad Sci
, vol.99
, pp. 3111-3116
-
-
Yablonskiy, D.A.1
-
15
-
-
84859108166
-
Mapping of 3He apparent diffusion coefficient anisotropy at sub-millisecond diffusion times in an elastase-instilled rat model of emphysema
-
doi: 10.1002/mrm.23098
-
Xu X, Boudreau M, Ouriadov A, Santyr GE,. Mapping of 3He apparent diffusion coefficient anisotropy at sub-millisecond diffusion times in an elastase-instilled rat model of emphysema. Magn Reson Med 2012; doi: 10.1002/mrm.23098.
-
(2012)
Magn Reson Med
-
-
Xu, X.1
Boudreau, M.2
Ouriadov, A.3
Santyr, G.E.4
-
16
-
-
33746742953
-
Time dependence of3He diffusion in the human lung: Measurement in the long-time regime using stimulated echoes
-
Wang C, Miller GW, Altes TA, de Lange EE, Cates GD Jr, Mugler JP,. Time dependence of3He diffusion in the human lung: measurement in the long-time regime using stimulated echoes. Magn Reson Med 2006; 56: 296-309.
-
(2006)
Magn Reson Med
, vol.56
, pp. 296-309
-
-
Wang, C.1
Miller, G.W.2
Altes, T.A.3
De Lange, E.E.4
Cates, Jr.G.D.5
Mugler, J.P.6
-
17
-
-
60349112013
-
Long-range diffusion of hyperpolarized3He in rats
-
Rodríguez I, Pérez-Sánchez JM, Peces-Barba G, Kaulisch T, Stiller D, Ruiz-Cabello J,. Long-range diffusion of hyperpolarized3He in rats. Magn Reson Med 2009; 61: 54-58.
-
(2009)
Magn Reson Med
, vol.61
, pp. 54-58
-
-
Rodríguez, I.1
Pérez-Sánchez, J.M.2
Peces-Barba, G.3
Kaulisch, T.4
Stiller, D.5
Ruiz-Cabello, J.6
-
18
-
-
2342588151
-
Magnetization tagging decay to measure long-range3He diffusion in healthy and emphysematous canine lungs
-
Woods JC, Yablonskiy DA, Chino K, Tanoli TSK, Cooper JD, Conradi MS,. Magnetization tagging decay to measure long-range3He diffusion in healthy and emphysematous canine lungs. Magn Reson Med 2004; 51: 1002-1008.
-
(2004)
Magn Reson Med
, vol.51
, pp. 1002-1008
-
-
Woods, J.C.1
Yablonskiy, D.A.2
Chino, K.3
Tanoli, T.S.K.4
Cooper, J.D.5
Conradi, M.S.6
-
19
-
-
47549111310
-
An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging
-
Tsai LL, Mair RW, Rosen MS, Patz S, Walsworth RL,. An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging. J Magn Reson 2008; 193: 274-285.
-
(2008)
J Magn Reson
, vol.193
, pp. 274-285
-
-
Tsai, L.L.1
Mair, R.W.2
Rosen, M.S.3
Patz, S.4
Walsworth, R.L.5
-
20
-
-
54949093229
-
A variable field strength system for hyperpolarized noble gas MR imaging of rodent lungs
-
Dominguez-Viqueira W, Parra-Robles J, Fox M, Handler WB, Chronik BA, Santyr GE,. A variable field strength system for hyperpolarized noble gas MR imaging of rodent lungs. Concepts Magn Reson B: Magn Reson Eng 2008; 33B: 124-137.
-
(2008)
Concepts Magn Reson B: Magn Reson Eng
, vol.33 B
, pp. 124-137
-
-
Dominguez-Viqueira, W.1
Parra-Robles, J.2
Fox, M.3
Handler, W.B.4
Chronik, B.A.5
Santyr, G.E.6
-
21
-
-
12844279813
-
Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs
-
Parra-Robles J, Cross AR, Santyr GE,. Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs. Med Phys 2005; 32: 221.
-
(2005)
Med Phys
, vol.32
, pp. 221
-
-
Parra-Robles, J.1
Cross, A.R.2
Santyr, G.E.3
-
22
-
-
42749094084
-
Theoretical prediction and experimental measurement of the field dependence of the apparent transverse relaxation of hyperpolarized noble gases in lungs
-
Parra-Robles J, Dominguez Viqueira W, Xu X, Ouriadov A, Santyr GE,. Theoretical prediction and experimental measurement of the field dependence of the apparent transverse relaxation of hyperpolarized noble gases in lungs. J Magn Reson 2008; 192: 85-91.
-
(2008)
J Magn Reson
, vol.192
, pp. 85-91
-
-
Parra-Robles, J.1
Dominguez Viqueira, W.2
Xu, X.3
Ouriadov, A.4
Santyr, G.E.5
-
23
-
-
0036136002
-
CPMG measurements and ultrafast imaging in human lungs with hyperpolarized helium-3 at low field (0.1 T)
-
Durand E, Guillot G, Darrasse L, Tastevin G, Nacher PJ, Vignaud A, Vattolo D, Bittoun J,. CPMG measurements and ultrafast imaging in human lungs with hyperpolarized helium-3 at low field (0.1 T). Magn Reson Med 2002; 47: 75-81.
-
(2002)
Magn Reson Med
, vol.47
, pp. 75-81
-
-
Durand, E.1
Guillot, G.2
Darrasse, L.3
Tastevin, G.4
Nacher, P.J.5
Vignaud, A.6
Vattolo, D.7
Bittoun, J.8
-
24
-
-
4744371577
-
Finite-difference simulations of 3He diffusion in 3D alveolar ducts: Comparison with the cylinder model
-
Fichele S, Paley MNJ, Woodhouse N, Griffiths PD, van Beek EJR, Wild JM,. Finite-difference simulations of 3He diffusion in 3D alveolar ducts: comparison with the cylinder model. Magn Reson Med 2004; 52: 917-920.
-
(2004)
Magn Reson Med
, vol.52
, pp. 917-920
-
-
Fichele, S.1
Paley, M.N.J.2
Woodhouse, N.3
Griffiths, P.D.4
Van Beek, E.J.R.5
Wild, J.M.6
-
25
-
-
1242287522
-
Investigating 3He diffusion NMR in the lungs using finite difference simulations and in vivo PGSE experiments
-
Fichele S,. Investigating 3He diffusion NMR in the lungs using finite difference simulations and in vivo PGSE experiments. J Magn Reson 2004; 167: 1-11.
-
(2004)
J Magn Reson
, vol.167
, pp. 1-11
-
-
Fichele, S.1
-
26
-
-
0018606001
-
Diffusion of water in the endosperm tissue of wheat grains as studied by pulsed field gradient nuclear magnetic resonance
-
Callaghan PT, Jolley KW, Lelievre J,. Diffusion of water in the endosperm tissue of wheat grains as studied by pulsed field gradient nuclear magnetic resonance. Biophys J 1979; 28: 133-141.
-
(1979)
Biophys J
, vol.28
, pp. 133-141
-
-
Callaghan, P.T.1
Jolley, K.W.2
Lelievre, J.3
-
27
-
-
38149014668
-
In vivo lung morphometry with hyperpolarized 3He diffusion MRI: Theoretical background
-
Sukstanskii A, Yablonskiy D,. In vivo lung morphometry with hyperpolarized 3He diffusion MRI: theoretical background. J Magn Reson 2008; 190: 200-210.
-
(2008)
J Magn Reson
, vol.190
, pp. 200-210
-
-
Sukstanskii, A.1
Yablonskiy, D.2
-
28
-
-
70350124053
-
Quantification of lung microstructure with hyperpolarized 3He diffusion MRI
-
Yablonskiy DA, Sukstanskii AL, Woods JC, Gierada DS, Quirk JD, Hogg JC, Cooper JD, Conradi MS,. Quantification of lung microstructure with hyperpolarized 3He diffusion MRI. J Appl Physiol 2009; 107: 1258-1265.
-
(2009)
J Appl Physiol
, vol.107
, pp. 1258-1265
-
-
Yablonskiy, D.A.1
Sukstanskii, A.L.2
Woods, J.C.3
Gierada, D.S.4
Quirk, J.D.5
Hogg, J.C.6
Cooper, J.D.7
Conradi, M.S.8
-
29
-
-
36148998718
-
Hyperpolarized (129)Xe MRI: A viable functional lung imaging modality?
-
Patz S, Hersman FW, Muradian I, Hrovat MI, Ruset IC, Ketel S, Jacobson F, Topulos GP, Hatabu H, Butler JP,. Hyperpolarized (129)Xe MRI: a viable functional lung imaging modality? Eur J Radiol 2007; 64: 335-344.
-
(2007)
Eur J Radiol
, vol.64
, pp. 335-344
-
-
Patz, S.1
Hersman, F.W.2
Muradian, I.3
Hrovat, M.I.4
Ruset, I.C.5
Ketel, S.6
Jacobson, F.7
Topulos, G.P.8
Hatabu, H.9
Butler, J.P.10
-
30
-
-
33144457338
-
Optical pumping system design for large production of hyperpolarized
-
Ruset IC, Ketel S, Hersman FW,. Optical pumping system design for large production of hyperpolarized. Phys Rev Lett 2006; 96: 053002.
-
(2006)
Phys Rev Lett
, vol.96
, pp. 053002
-
-
Ruset, I.C.1
Ketel, S.2
Hersman, F.W.3
-
31
-
-
43249093673
-
Large production system for hyperpolarized 129Xe for human lung imaging studies
-
Hersman FW, Ruset IC, Ketel S, Muradian I, Covrig SD, Distelbrink J, Porter W, Watt D, Ketel J, Brackett J, Hope A, Patz S,. Large production system for hyperpolarized 129Xe for human lung imaging studies. Acad Radiol 2008; 15: 683-692.
-
(2008)
Acad Radiol
, vol.15
, pp. 683-692
-
-
Hersman, F.W.1
Ruset, I.C.2
Ketel, S.3
Muradian, I.4
Covrig, S.D.5
Distelbrink, J.6
Porter, W.7
Watt, D.8
Ketel, J.9
Brackett, J.10
Hope, A.11
Patz, S.12
-
32
-
-
43249124925
-
Human pulmonary imaging and spectroscopy with hyperpolarized 129Xe at 0.2T
-
Patz S, Muradian I, Hrovat MI, Ruset IC, Topulos G, Covrig SD, Frederick E, Hatabu H, Hersman FW, Butler JP,. Human pulmonary imaging and spectroscopy with hyperpolarized 129Xe at 0.2T. Acad Radiol 2008; 15: 713-727.
-
(2008)
Acad Radiol
, vol.15
, pp. 713-727
-
-
Patz, S.1
Muradian, I.2
Hrovat, M.I.3
Ruset, I.C.4
Topulos, G.5
Covrig, S.D.6
Frederick, E.7
Hatabu, H.8
Hersman, F.W.9
Butler, J.P.10
-
33
-
-
79952785642
-
Diffusion-weighted hyperpolarized (129) Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary disease
-
Kaushik SS, Cleveland ZI, Cofer GP, Metz G, Beaver D, Nouls J, Kraft M, Auffermann W, Wolber J, McAdams HP, Driehuys B,. Diffusion-weighted hyperpolarized (129) Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary disease. Magn Reson Med 2011; 65: 1154-1165.
-
(2011)
Magn Reson Med
, vol.65
, pp. 1154-1165
-
-
Kaushik, S.S.1
Cleveland, Z.I.2
Cofer, G.P.3
Metz, G.4
Beaver, D.5
Nouls, J.6
Kraft, M.7
Auffermann, W.8
Wolber, J.9
McAdams, H.P.10
Driehuys, B.11
-
34
-
-
78650737069
-
Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129
-
Mugler JP 3rd, Altes TA, Ruset IC, Dregely IM, Mata JF, Miller GW, Ketel S, Ketel J, Hersman FW, Ruppert K,. Simultaneous magnetic resonance imaging of ventilation distribution and gas uptake in the human lung using hyperpolarized xenon-129. Proc Natl Acad Sci USA 2010; 107: 21707-21712.
-
(2010)
Proc Natl Acad Sci USA
, vol.107
, pp. 21707-21712
-
-
Mugler III, J.P.1
Altes, T.A.2
Ruset, I.C.3
Dregely, I.M.4
Mata, J.F.5
Miller, G.W.6
Ketel, S.7
Ketel, J.8
Hersman, F.W.9
Ruppert, K.10
-
35
-
-
0019291109
-
Solubility of inert-gases in biological-fluids and tissues - A review
-
Weathersby PK, Homer LD,. Solubility of inert-gases in biological-fluids and tissues-a review. Undersea Biomed Res 1980; 7: 277-296.
-
(1980)
Undersea Biomed Res
, vol.7
, pp. 277-296
-
-
Weathersby, P.K.1
Homer, L.D.2
-
36
-
-
0036715975
-
Echo-planar MR imaging of dissolved hyperpolarized 129Xe
-
Mansson S, Johansson E, Svensson J, Olsson LE, Stahlberg F, Petersson JS, Golman K,. Echo-planar MR imaging of dissolved hyperpolarized 129Xe. Acta Radiol 2002; 43: 455-460.
-
(2002)
Acta Radiol
, vol.43
, pp. 455-460
-
-
Mansson, S.1
Johansson, E.2
Svensson, J.3
Olsson, L.E.4
Stahlberg, F.5
Petersson, J.S.6
Golman, K.7
-
37
-
-
77957880663
-
Hyperpolarized Xe MR imaging of alveolar gas uptake in humans
-
Cleveland ZI, Cofer GP, Metz G, Beaver D, Nouls J, Kaushik SS, Kraft M, Wolber J, Kelly KT, McAdams HP, Driehuys B,. Hyperpolarized Xe MR imaging of alveolar gas uptake in humans. PLoS One 2010; 5: e12192.
-
(2010)
PLoS One
, vol.5
-
-
Cleveland, Z.I.1
Cofer, G.P.2
Metz, G.3
Beaver, D.4
Nouls, J.5
Kaushik, S.S.6
Kraft, M.7
Wolber, J.8
Kelly, K.T.9
McAdams, H.P.10
Driehuys, B.11
-
38
-
-
33746685621
-
Measurement of xenon diffusing capacity in the rat lung by hyperpolarized 129Xe MRI and dynamic spectroscopy in a single breath-hold
-
Abdeen N, Cross A, Cron G, White S, Rand T, Miller D, Santyr G,. Measurement of xenon diffusing capacity in the rat lung by hyperpolarized 129Xe MRI and dynamic spectroscopy in a single breath-hold. Magn Reson Med 2006; 56: 255-264.
-
(2006)
Magn Reson Med
, vol.56
, pp. 255-264
-
-
Abdeen, N.1
Cross, A.2
Cron, G.3
White, S.4
Rand, T.5
Miller, D.6
Santyr, G.7
-
39
-
-
84857370695
-
Lung morphometry with hyperpolarized 129Xe: Theoretical background
-
Sukstanskii AL, Yablonskiy DA,. Lung morphometry with hyperpolarized 129Xe: Theoretical background. Magn Reson in Med 2012; 67: 856-866.
-
(2012)
Magn Reson in Med
, vol.67
, pp. 856-866
-
-
Sukstanskii, A.L.1
Yablonskiy, D.A.2
-
40
-
-
44949133164
-
Rapid and efficient mapping of regional ventilation in the rat lung using hyperpolarized3He with Flip angle variation for offset of RF and relaxation (FAVOR)
-
Santyr GE, Lam WW, Ouriadov A,. Rapid and efficient mapping of regional ventilation in the rat lung using hyperpolarized3He with Flip angle variation for offset of RF and relaxation (FAVOR). Magn Reson Med 2008; 59: 1304-1310.
-
(2008)
Magn Reson Med
, vol.59
, pp. 1304-1310
-
-
Santyr, G.E.1
Lam, W.W.2
Ouriadov, A.3
-
41
-
-
84872844669
-
Imaging of lung micromechanics with hyperpolarized gas diffusion MRI: Regional compliace
-
Xin Y, Enami K, Kadlecek SJ, Mongkolwisetwara P, Kuzma NN, Profka H, Xu Y, Hamedani H, Pullinger BM, Ghosh RK, Rajaei S, Pickup S, Ishii M, Rizi RR,. Imaging of lung micromechanics with hyperpolarized gas diffusion MRI: regional compliace. Proc Int Soc Mag Reson Med 2011; 19.
-
(2011)
Proc Int Soc Mag Reson Med
, vol.19
-
-
Xin, Y.1
Enami, K.2
Kadlecek, S.J.3
Mongkolwisetwara, P.4
Kuzma, N.N.5
Profka, H.6
Xu, Y.7
Hamedani, H.8
Pullinger, B.M.9
Ghosh, R.K.10
Rajaei, S.11
Pickup, S.12
Ishii, M.13
Rizi, R.R.14
-
42
-
-
77953007307
-
Litz wire radiofrequency receive coils for hyperpolarized noble gas MR imaging of rodent lungs at 73.5 mT
-
Dominguez-Viqueira W, Berger W, Parra-Robles J, Santyr GE,. Litz wire radiofrequency receive coils for hyperpolarized noble gas MR imaging of rodent lungs at 73.5 mT. Concept Magn Reson B 2010; 37B: 75-85.
-
(2010)
Concept Magn Reson B
, vol.37 B
, pp. 75-85
-
-
Dominguez-Viqueira, W.1
Berger, W.2
Parra-Robles, J.3
Santyr, G.E.4
-
43
-
-
33646376290
-
Spin diffusion measurements: Spin echoes in the presence of a time-dependent field gradient
-
Stejskal EO, Tanner JE,. Spin diffusion measurements: spin echoes in the presence of a time-dependent field gradient. J Chem Phys 1965; 42: 288-292.
-
(1965)
J Chem Phys
, vol.42
, pp. 288-292
-
-
Stejskal, E.O.1
Tanner, J.E.2
-
44
-
-
18744418619
-
Lung fixation for the preservation of air spaces
-
Blümler P, Acosta RH, Thomas-Semm A, Reuss S,. Lung fixation for the preservation of air spaces. Exp Lung Res 2004; 30: 73-82.
-
(2004)
Exp Lung Res
, vol.30
, pp. 73-82
-
-
Blümler, P.1
Acosta, R.H.2
Thomas-Semm, A.3
Reuss, S.4
-
46
-
-
0031873521
-
Lung morphometry by unbiased methods in emphysema: Bronchial and blood vessel volume, alveolar surface area and capillary length
-
Wiebe BM, Laursen H,. Lung morphometry by unbiased methods in emphysema: bronchial and blood vessel volume, alveolar surface area and capillary length. APMIS: acta pathologica, microbiologica, et immunologica Scandinavica 1998; 106: 651-656.
-
(1998)
APMIS: Acta Pathologica, Microbiologica, et Immunologica Scandinavica
, vol.106
, pp. 651-656
-
-
Wiebe, B.M.1
Laursen, H.2
-
47
-
-
43249093673
-
Large production system for hyperpolarized 129Xe for human lung imaging studies
-
Hersman FW, Ruset IC, Ketel S, Muradian I, Covrig SD, Distelbrink J, Porter W, Watt D, Ketel J, Brackett J, Hope A, Patz S,. Large production system for hyperpolarized 129Xe for human lung imaging studies. Acad Radiol 2008; 15: 683-692.
-
(2008)
Acad Radiol
, vol.15
, pp. 683-692
-
-
Hersman, F.W.1
Ruset, I.C.2
Ketel, S.3
Muradian, I.4
Covrig, S.D.5
Distelbrink, J.6
Porter, W.7
Watt, D.8
Ketel, J.9
Brackett, J.10
Hope, A.11
Patz, S.12
-
48
-
-
22744450648
-
Limitations of apparent diffusion coefficient-based models in characterizing non-gaussian diffusion
-
Liu C, Bammer R, Moseley ME,. Limitations of apparent diffusion coefficient-based models in characterizing non-gaussian diffusion. Magn Reson Med 2005; 54: 419-428.
-
(2005)
Magn Reson Med
, vol.54
, pp. 419-428
-
-
Liu, C.1
Bammer, R.2
Moseley, M.E.3
-
49
-
-
77955228075
-
Experimental investigation and numerical simulation of 3He gas diffusion in simple geometries: Implications for analytical models of 3He MR lung morphometry
-
Parra-Robles J, Ajraoui S, Deppe MH, Parnell SR, Wild JM,. Experimental investigation and numerical simulation of 3He gas diffusion in simple geometries: implications for analytical models of 3He MR lung morphometry. J Magn Reson 2010; 204: 228-238.
-
(2010)
J Magn Reson
, vol.204
, pp. 228-238
-
-
Parra-Robles, J.1
Ajraoui, S.2
Deppe, M.H.3
Parnell, S.R.4
Wild, J.M.5
-
50
-
-
34447628702
-
Simulation of the apparent diffusion of helium-3 in the human acinus
-
Verbanck S, Paiva M,. Simulation of the apparent diffusion of helium-3 in the human acinus. J Appl Physiol 2007; 103: 249-254.
-
(2007)
J Appl Physiol
, vol.103
, pp. 249-254
-
-
Verbanck, S.1
Paiva, M.2
-
51
-
-
45149134450
-
Role of collateral paths in long-range diffusion in lungs
-
Bartel SE, Haywood SE, Woods JC, Chang YV, Menard C, Yablonskiy DA, Gierada DS, Conradi MS,. Role of collateral paths in long-range diffusion in lungs. J Appl Physiol 2008; 104: 1495-1503.
-
(2008)
J Appl Physiol
, vol.104
, pp. 1495-1503
-
-
Bartel, S.E.1
Haywood, S.E.2
Woods, J.C.3
Chang, Y.V.4
Menard, C.5
Yablonskiy, D.A.6
Gierada, D.S.7
Conradi, M.S.8
-
52
-
-
0034087960
-
Design and fabrication of a three-axis multilayer gradient coil for magnetic resonance microscopy of mice
-
Chronik B, Alejski A, Rutt BK,. Design and fabrication of a three-axis multilayer gradient coil for magnetic resonance microscopy of mice. Magn Reson Mater Biol Phys Med 2000; 10: 131-146.
-
(2000)
Magn Reson Mater Biol Phys Med
, vol.10
, pp. 131-146
-
-
Chronik, B.1
Alejski, A.2
Rutt, B.K.3
|