-
1
-
-
0025095472
-
The adult cervical spine: implications for airway management
-
Crosby E.T., Lui A. The adult cervical spine: implications for airway management. Can J Anaesth 1990, 37:77-93.
-
(1990)
Can J Anaesth
, vol.37
, pp. 77-93
-
-
Crosby, E.T.1
Lui, A.2
-
2
-
-
0034950360
-
Distribution and patterns of blunt traumatic cervical spine injury
-
NEXUS Group
-
Goldberg W., Mueller C., Panacek E., NEXUS Group, et al. Distribution and patterns of blunt traumatic cervical spine injury. Ann Emerg Med 2001, 38:17-21.
-
(2001)
Ann Emerg Med
, vol.38
, pp. 17-21
-
-
Goldberg, W.1
Mueller, C.2
Panacek, E.3
-
3
-
-
0032967995
-
Cervical spine imaging in patients with trauma: determination of fracture risk to optimize use
-
Blackmore C.C., Emerson S.S., Mann F.A., et al. Cervical spine imaging in patients with trauma: determination of fracture risk to optimize use. Radiology 1999, 211:759-765.
-
(1999)
Radiology
, vol.211
, pp. 759-765
-
-
Blackmore, C.C.1
Emerson, S.S.2
Mann, F.A.3
-
4
-
-
0033999717
-
Nonskeletal cervical spine injuries: epidemiology and diagnostic pitfalls
-
Demetriades D., Charalambides K., Chahwan S., et al. Nonskeletal cervical spine injuries: epidemiology and diagnostic pitfalls. J Trauma 2000, 48:724-727.
-
(2000)
J Trauma
, vol.48
, pp. 724-727
-
-
Demetriades, D.1
Charalambides, K.2
Chahwan, S.3
-
6
-
-
0036127156
-
Cervical spine trauma associated with moderate and severe head injury: incidence, risk factors, and injury characteristics
-
Holly L.T., Kelly D.F., Counelis G.J., et al. Cervical spine trauma associated with moderate and severe head injury: incidence, risk factors, and injury characteristics. J Neurosurg 2002, 96:285-291.
-
(2002)
J Neurosurg
, vol.96
, pp. 285-291
-
-
Holly, L.T.1
Kelly, D.F.2
Counelis, G.J.3
-
7
-
-
24944549606
-
Reduction in mouth opening with semi-rigid cervical collars
-
Goutcher C.M., Lochhead V. Reduction in mouth opening with semi-rigid cervical collars. Br J Anaesth 2005, 95:344-348.
-
(2005)
Br J Anaesth
, vol.95
, pp. 344-348
-
-
Goutcher, C.M.1
Lochhead, V.2
-
8
-
-
0024042917
-
Appropriate techniques for airway management of emergency patients with suspected spinal cord injury
-
Grande C.M., Barton C.R., Stene J.K. Appropriate techniques for airway management of emergency patients with suspected spinal cord injury. Anesth Analg 1988, 67:714-715.
-
(1988)
Anesth Analg
, vol.67
, pp. 714-715
-
-
Grande, C.M.1
Barton, C.R.2
Stene, J.K.3
-
9
-
-
0033778511
-
Effects of cervical spine immobilization technique and laryngoscope blade selection on an unstable cervical spine in a cadaver model of intubation
-
Gerling M.C., Davis D.P., Hamilton R.S., et al. Effects of cervical spine immobilization technique and laryngoscope blade selection on an unstable cervical spine in a cadaver model of intubation. Ann Emerg Med 2000, 36:293-300.
-
(2000)
Ann Emerg Med
, vol.36
, pp. 293-300
-
-
Gerling, M.C.1
Davis, D.P.2
Hamilton, R.S.3
-
10
-
-
0021123860
-
Experimental cervical spine injury model: evaluation of airway management and splinting techniques
-
Aprahamian C., Thompson B.M., Finger W.A., et al. Experimental cervical spine injury model: evaluation of airway management and splinting techniques. Ann Emerg Med 1984, 13:584-587.
-
(1984)
Ann Emerg Med
, vol.13
, pp. 584-587
-
-
Aprahamian, C.1
Thompson, B.M.2
Finger, W.A.3
-
11
-
-
0034033226
-
Segmental cervical spine motion during orotracheal intubation of the intact and injured spine with and without external stabilization
-
Lennarson P.J., Smith D., Todd M.M., et al. Segmental cervical spine motion during orotracheal intubation of the intact and injured spine with and without external stabilization. J Neurosurg 2000, 92:201-206.
-
(2000)
J Neurosurg
, vol.92
, pp. 201-206
-
-
Lennarson, P.J.1
Smith, D.2
Todd, M.M.3
-
12
-
-
0034874984
-
Cervical spinal motion during intubation: efficacy of stabilization maneuvers in the setting of complete segmental instability
-
Lennarson P.J., Smith D.W., Sawin P.D., et al. Cervical spinal motion during intubation: efficacy of stabilization maneuvers in the setting of complete segmental instability. J Neurosurg 2001, 94:265-270.
-
(2001)
J Neurosurg
, vol.94
, pp. 265-270
-
-
Lennarson, P.J.1
Smith, D.W.2
Sawin, P.D.3
-
13
-
-
0033756645
-
Cervical spine motion during airway management: a cinefluoroscopic study of the posteriorly destabilized third cervical vertebrae in human cadavers
-
Brimacombe J., Keller C., Kunzel K.H., et al. Cervical spine motion during airway management: a cinefluoroscopic study of the posteriorly destabilized third cervical vertebrae in human cadavers. Anesth Analg 2000, 91:1274-1278.
-
(2000)
Anesth Analg
, vol.91
, pp. 1274-1278
-
-
Brimacombe, J.1
Keller, C.2
Kunzel, K.H.3
-
14
-
-
0022458991
-
Cervical spine movement during orotracheal intubation
-
Majernick T.G., Bieniek R., Houston J.B., et al. Cervical spine movement during orotracheal intubation. Ann Emerg Med 1986, 15:417-420.
-
(1986)
Ann Emerg Med
, vol.15
, pp. 417-420
-
-
Majernick, T.G.1
Bieniek, R.2
Houston, J.B.3
-
15
-
-
0030770691
-
Spinal cord injury as a result of endotracheal intubation in patients with undiagnosed cervical spine fractures
-
Muckart D.J., Bhagwanjee S., van der Merwe R. Spinal cord injury as a result of endotracheal intubation in patients with undiagnosed cervical spine fractures. Anesthesiology 1997, 87:418-420.
-
(1997)
Anesthesiology
, vol.87
, pp. 418-420
-
-
Muckart, D.J.1
Bhagwanjee, S.2
van der Merwe, R.3
-
16
-
-
0031767044
-
Massive pyramidal tract signs after endotracheal intubation: a case report of spondyloepiphyseal dysplasia congenita
-
Redl G. Massive pyramidal tract signs after endotracheal intubation: a case report of spondyloepiphyseal dysplasia congenita. Anesthesiology 1998, 89:1262-1264.
-
(1998)
Anesthesiology
, vol.89
, pp. 1262-1264
-
-
Redl, G.1
-
17
-
-
0031837851
-
Neurologic deterioration after cervical spinal cord injury
-
Farmer J., Vaccaro A., Albert T.J., et al. Neurologic deterioration after cervical spinal cord injury. J Spinal Disord 1998, 11:192-196.
-
(1998)
J Spinal Disord
, vol.11
, pp. 192-196
-
-
Farmer, J.1
Vaccaro, A.2
Albert, T.J.3
-
18
-
-
0034202246
-
Spinal cord injury and direct laryngoscopy-the legend lives on
-
McLeod A.D., Calder I. Spinal cord injury and direct laryngoscopy-the legend lives on. Br J Anaesth 2000, 84:705-709.
-
(2000)
Br J Anaesth
, vol.84
, pp. 705-709
-
-
McLeod, A.D.1
Calder, I.2
-
19
-
-
0034896550
-
Initial experience of emergency physicians using the intubating laryngeal mask airway: a case series
-
Martel M., Reardon R.F., Cochrane J. Initial experience of emergency physicians using the intubating laryngeal mask airway: a case series. Acad Emerg Med 2001, 8:815-822.
-
(2001)
Acad Emerg Med
, vol.8
, pp. 815-822
-
-
Martel, M.1
Reardon, R.F.2
Cochrane, J.3
-
20
-
-
0035032733
-
The intubating laryngeal mask airway after induction of general anesthesia versus awake fiberoptic intubation in patients with difficult airways
-
Joo H.S., Kapoor S., Rose D.K., et al. The intubating laryngeal mask airway after induction of general anesthesia versus awake fiberoptic intubation in patients with difficult airways. Anesth Analg 2001, 92:1342-1346.
-
(2001)
Anesth Analg
, vol.92
, pp. 1342-1346
-
-
Joo, H.S.1
Kapoor, S.2
Rose, D.K.3
-
21
-
-
0034897548
-
The intubating laryngeal mask airway: suggestions for use in the emergency department
-
Reardon R.F., Martel M. The intubating laryngeal mask airway: suggestions for use in the emergency department. Acad Emerg Med 2001, 8:833-838.
-
(2001)
Acad Emerg Med
, vol.8
, pp. 833-838
-
-
Reardon, R.F.1
Martel, M.2
-
22
-
-
0033945944
-
Segmental cervical spine movement with the intubating laryngeal mask during manual in-line stabilization in patients with cervical pathology undergoing cervical spine surgery
-
Kihara S., Watanabe S., Brimacombe J., et al. Segmental cervical spine movement with the intubating laryngeal mask during manual in-line stabilization in patients with cervical pathology undergoing cervical spine surgery. Anesth Analg 2000, 91:195-200.
-
(2000)
Anesth Analg
, vol.91
, pp. 195-200
-
-
Kihara, S.1
Watanabe, S.2
Brimacombe, J.3
-
23
-
-
78650708929
-
Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2,004 Glidescope intubations, complications, and failures from two institutions
-
Aziz M.F., Healy D., Kheterpal S., et al. Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2,004 Glidescope intubations, complications, and failures from two institutions. Anesthesiology 2011, 114:34-41.
-
(2011)
Anesthesiology
, vol.114
, pp. 34-41
-
-
Aziz, M.F.1
Healy, D.2
Kheterpal, S.3
-
24
-
-
84859099463
-
Comparative effectiveness of the C-MAC video laryngoscope versus direct laryngoscopy in the setting of the predicted difficult airway
-
Aziz M.F., Dillman D., Fu R., et al. Comparative effectiveness of the C-MAC video laryngoscope versus direct laryngoscopy in the setting of the predicted difficult airway. Anesthesiology 2012, 116:629-636.
-
(2012)
Anesthesiology
, vol.116
, pp. 629-636
-
-
Aziz, M.F.1
Dillman, D.2
Fu, R.3
-
25
-
-
62549106552
-
Expected difficult tracheal intubation: a prospective comparison of direct laryngoscopy and video laryngoscopy in 200 patients
-
Jungbauer A., Schumann M., Brunkhorst V., et al. Expected difficult tracheal intubation: a prospective comparison of direct laryngoscopy and video laryngoscopy in 200 patients. Br J Anaesth 2009, 102:546-550.
-
(2009)
Br J Anaesth
, vol.102
, pp. 546-550
-
-
Jungbauer, A.1
Schumann, M.2
Brunkhorst, V.3
-
26
-
-
38349019433
-
Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation
-
Maharaj C.H., Costello J.F., Harte B.H., et al. Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation. Anaesthesia 2008, 63:182-188.
-
(2008)
Anaesthesia
, vol.63
, pp. 182-188
-
-
Maharaj, C.H.1
Costello, J.F.2
Harte, B.H.3
-
27
-
-
74949099834
-
Randomized controlled trial of the Pentax AWS, Glidescope, and Macintosh laryngoscopes in predicted difficult intubation
-
Malik M.A., Subramaniam R., Maharaj C.H., et al. Randomized controlled trial of the Pentax AWS, Glidescope, and Macintosh laryngoscopes in predicted difficult intubation. Br J Anaesth 2009, 103:761-768.
-
(2009)
Br J Anaesth
, vol.103
, pp. 761-768
-
-
Malik, M.A.1
Subramaniam, R.2
Maharaj, C.H.3
-
28
-
-
66149093148
-
Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope, LMA CTrach, and the Macintosh laryngoscopes
-
Malik M.A., Subramaniam R., Churasia S., et al. Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope, LMA CTrach, and the Macintosh laryngoscopes. Br J Anaesth 2009, 102:654-661.
-
(2009)
Br J Anaesth
, vol.102
, pp. 654-661
-
-
Malik, M.A.1
Subramaniam, R.2
Churasia, S.3
-
29
-
-
77449105751
-
Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope
-
Serocki G., Bein B., Scholz J., et al. Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope. Eur J Anaesthesiol 2010, 27:24-30.
-
(2010)
Eur J Anaesthesiol
, vol.27
, pp. 24-30
-
-
Serocki, G.1
Bein, B.2
Scholz, J.3
-
30
-
-
41949120312
-
Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study
-
Enomoto Y., Asai T., Arai T., et al. Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study. Br J Anaesth 2008, 100:544-548.
-
(2008)
Br J Anaesth
, vol.100
, pp. 544-548
-
-
Enomoto, Y.1
Asai, T.2
Arai, T.3
-
31
-
-
54249167043
-
Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization
-
Malik M.A., Maharaj C.H., Harte B.H., et al. Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization. Br J Anaesth 2008, 101:723-730.
-
(2008)
Br J Anaesth
, vol.101
, pp. 723-730
-
-
Malik, M.A.1
Maharaj, C.H.2
Harte, B.H.3
-
32
-
-
34250891900
-
Endotracheal intubation in patients with cervical spine immobilization: a comparison of Macintosh and Airtraq laryngoscopes
-
Maharaj C.H., Buckley E., Harte B.H., et al. Endotracheal intubation in patients with cervical spine immobilization: a comparison of Macintosh and Airtraq laryngoscopes. Anesthesiology 2007, 107:53-59.
-
(2007)
Anesthesiology
, vol.107
, pp. 53-59
-
-
Maharaj, C.H.1
Buckley, E.2
Harte, B.H.3
-
33
-
-
0032744360
-
Evaluation of tracheal intubation difficulty in patients with cervical spine immobilization: fiberoptic (WuScope) versus conventional laryngoscopy
-
Smith C.E., Pinchak A.B., Sidhu T.S., et al. Evaluation of tracheal intubation difficulty in patients with cervical spine immobilization: fiberoptic (WuScope) versus conventional laryngoscopy. Anesthesiology 1999, 91:1253-1259.
-
(1999)
Anesthesiology
, vol.91
, pp. 1253-1259
-
-
Smith, C.E.1
Pinchak, A.B.2
Sidhu, T.S.3
-
34
-
-
0031469105
-
The intubation difficulty scale (IDS): proposal and evaluation of a new score characterizing the complexity of endotracheal intubation
-
Adnet F., Borron S.W., Racine S.X., et al. The intubation difficulty scale (IDS): proposal and evaluation of a new score characterizing the complexity of endotracheal intubation. Anesthesiology 1997, 87:1290-1297.
-
(1997)
Anesthesiology
, vol.87
, pp. 1290-1297
-
-
Adnet, F.1
Borron, S.W.2
Racine, S.X.3
-
35
-
-
79960546333
-
Comparison of the C-MAC(R), Airtraq(R), and Macintosh laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization
-
McElwain J., Laffey J.G. Comparison of the C-MAC(R), Airtraq(R), and Macintosh laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization. Br J Anaesth 2011, 107:258-264.
-
(2011)
Br J Anaesth
, vol.107
, pp. 258-264
-
-
McElwain, J.1
Laffey, J.G.2
-
36
-
-
38449091187
-
Upper cervical spine movement during intubation: fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope
-
Maruyama K., Yamada T., Kawakami R., et al. Upper cervical spine movement during intubation: fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope. Br J Anaesth 2008, 100:120-124.
-
(2008)
Br J Anaesth
, vol.100
, pp. 120-124
-
-
Maruyama, K.1
Yamada, T.2
Kawakami, R.3
-
37
-
-
34548602041
-
Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope
-
Hirabayashi Y., Fujita A., Seo N., et al. Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope. Anaesthesia 2007, 62:1050-1055.
-
(2007)
Anaesthesia
, vol.62
, pp. 1050-1055
-
-
Hirabayashi, Y.1
Fujita, A.2
Seo, N.3
-
38
-
-
0028916427
-
Cervical spine movement during laryngoscopy with the Bullard, Macintosh, and Miller laryngoscopes
-
Hastings R.H., Vigil A.C., Hanna R., et al. Cervical spine movement during laryngoscopy with the Bullard, Macintosh, and Miller laryngoscopes. Anesthesiology 1995, 82:859-869.
-
(1995)
Anesthesiology
, vol.82
, pp. 859-869
-
-
Hastings, R.H.1
Vigil, A.C.2
Hanna, R.3
-
39
-
-
51849102957
-
Randomized cross-over comparison of cervical-spine motion with the AirWay Scope or Macintosh laryngoscope with in-line stabilization: a video-fluoroscopic study
-
Maruyama K., Yamada T., Kawakami R., et al. Randomized cross-over comparison of cervical-spine motion with the AirWay Scope or Macintosh laryngoscope with in-line stabilization: a video-fluoroscopic study. Br J Anaesth 2008, 101:563-567.
-
(2008)
Br J Anaesth
, vol.101
, pp. 563-567
-
-
Maruyama, K.1
Yamada, T.2
Kawakami, R.3
-
40
-
-
23944457635
-
Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope
-
Turkstra T.P., Craen R.A., Pelz D.M., et al. Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope. Anesth Analg 2005, 101:910-915.
-
(2005)
Anesth Analg
, vol.101
, pp. 910-915
-
-
Turkstra, T.P.1
Craen, R.A.2
Pelz, D.M.3
-
41
-
-
67650092016
-
Cervical spine motion: a fluoroscopic comparison of the AirTraq Laryngoscope versus the Macintosh laryngoscope
-
Turkstra T.P., Pelz D.M., Jones P.M. Cervical spine motion: a fluoroscopic comparison of the AirTraq Laryngoscope versus the Macintosh laryngoscope. Anesthesiology 2009, 111:97-101.
-
(2009)
Anesthesiology
, vol.111
, pp. 97-101
-
-
Turkstra, T.P.1
Pelz, D.M.2
Jones, P.M.3
-
42
-
-
39749120846
-
Cervical spine motion during tracheal intubation with manual in-line stabilization: direct laryngoscopy versus GlideScope videolaryngoscopy
-
Robitaille A., Williams S.R., Tremblay M.H., et al. Cervical spine motion during tracheal intubation with manual in-line stabilization: direct laryngoscopy versus GlideScope videolaryngoscopy. Anesth Analg 2008, 106:935-941.
-
(2008)
Anesth Analg
, vol.106
, pp. 935-941
-
-
Robitaille, A.1
Williams, S.R.2
Tremblay, M.H.3
-
43
-
-
58749099150
-
Laryngoscopy via Macintosh blade versus GlideScope: success rate and time for endotracheal intubation in untrained medical personnel
-
Nouruzi-Sedeh P., Schumann M., Groeben H. Laryngoscopy via Macintosh blade versus GlideScope: success rate and time for endotracheal intubation in untrained medical personnel. Anesthesiology 2009, 110:32-37.
-
(2009)
Anesthesiology
, vol.110
, pp. 32-37
-
-
Nouruzi-Sedeh, P.1
Schumann, M.2
Groeben, H.3
-
44
-
-
79960839973
-
The C-MAC videolaryngoscope for prehospital emergency intubation: a prospective, multicentre, observational study
-
Cavus E., Callies A., Doerges V., et al. The C-MAC videolaryngoscope for prehospital emergency intubation: a prospective, multicentre, observational study. Emerg Med J 2011, 28:650-653.
-
(2011)
Emerg Med J
, vol.28
, pp. 650-653
-
-
Cavus, E.1
Callies, A.2
Doerges, V.3
-
45
-
-
84857847010
-
Variables associated with successful intubation attempts using video laryngoscopy: a preliminary report in a helicopter emergency medical service
-
Carlson J.N., Quintero J., Guyette F.X., et al. Variables associated with successful intubation attempts using video laryngoscopy: a preliminary report in a helicopter emergency medical service. Prehosp Emerg Care 2012, 16:293-298.
-
(2012)
Prehosp Emerg Care
, vol.16
, pp. 293-298
-
-
Carlson, J.N.1
Quintero, J.2
Guyette, F.X.3
-
46
-
-
79952120707
-
Use of the Airtraq laryngoscope for emergency intubation in the prehospital setting: a randomized control trial
-
Trimmel H., Kreutziger J., Fertsak G., et al. Use of the Airtraq laryngoscope for emergency intubation in the prehospital setting: a randomized control trial. Crit Care Med 2011, 39:489-493.
-
(2011)
Crit Care Med
, vol.39
, pp. 489-493
-
-
Trimmel, H.1
Kreutziger, J.2
Fertsak, G.3
-
47
-
-
0033034372
-
Devices for difficult airway management in academic emergency departments: results of a national survey
-
Levitan R.M., Kush S., Hollander J.E. Devices for difficult airway management in academic emergency departments: results of a national survey. Ann Emerg Med 1999, 33:694-698.
-
(1999)
Ann Emerg Med
, vol.33
, pp. 694-698
-
-
Levitan, R.M.1
Kush, S.2
Hollander, J.E.3
-
48
-
-
0025324436
-
Fiberoptic intubation in the emergency department
-
Mlinek E.J., Clinton J.E., Plummer D., et al. Fiberoptic intubation in the emergency department. Ann Emerg Med 1990, 19:359-362.
-
(1990)
Ann Emerg Med
, vol.19
, pp. 359-362
-
-
Mlinek, E.J.1
Clinton, J.E.2
Plummer, D.3
-
49
-
-
0036625097
-
The failed intubation attempt in the emergency department: analysis of prevalence, rescue techniques, and personnel
-
Bair A.E., Filbin M.R., Kulkarni R.G., et al. The failed intubation attempt in the emergency department: analysis of prevalence, rescue techniques, and personnel. J Emerg Med 2002, 23:131-140.
-
(2002)
J Emerg Med
, vol.23
, pp. 131-140
-
-
Bair, A.E.1
Filbin, M.R.2
Kulkarni, R.G.3
-
50
-
-
67649882055
-
Utilization of a Glidescope videolaryngoscope for orotracheal intubations in different emergency airway management settings
-
Lim H.C., Goh S.H. Utilization of a Glidescope videolaryngoscope for orotracheal intubations in different emergency airway management settings. Eur J Emerg Med 2009, 16:68-73.
-
(2009)
Eur J Emerg Med
, vol.16
, pp. 68-73
-
-
Lim, H.C.1
Goh, S.H.2
-
51
-
-
78649970748
-
Endotracheal intubation using a GlideScope video laryngoscope by emergency physicians: a multicentre analysis of 345 attempts in adult patients
-
Korean Emergency Airway Management Registry (KEAMR) Investigators
-
Choi H.J., Kang H.G., Lim T.H., Korean Emergency Airway Management Registry (KEAMR) Investigators, et al. Endotracheal intubation using a GlideScope video laryngoscope by emergency physicians: a multicentre analysis of 345 attempts in adult patients. Emerg Med J 2010, 27:380-382.
-
(2010)
Emerg Med J
, vol.27
, pp. 380-382
-
-
Choi, H.J.1
Kang, H.G.2
Lim, T.H.3
-
52
-
-
70149105482
-
A comparison of GlideScope video laryngoscopy versus direct laryngoscopy intubation in the emergency department
-
Platts-Mills T.F., Campagne D., Chinnock B., et al. A comparison of GlideScope video laryngoscopy versus direct laryngoscopy intubation in the emergency department. Acad Emerg Med 2009, 16:866-871.
-
(2009)
Acad Emerg Med
, vol.16
, pp. 866-871
-
-
Platts-Mills, T.F.1
Campagne, D.2
Chinnock, B.3
-
53
-
-
84859711768
-
Tracheal intubation in the emergency department: a comparison of GlideScope((R)) video laryngoscopy to direct laryngoscopy in 822 intubations
-
Sakles J.C., Mosier J.M., Chiu S., et al. Tracheal intubation in the emergency department: a comparison of GlideScope((R)) video laryngoscopy to direct laryngoscopy in 822 intubations. J Emerg Med 2012, 42:400-405.
-
(2012)
J Emerg Med
, vol.42
, pp. 400-405
-
-
Sakles, J.C.1
Mosier, J.M.2
Chiu, S.3
-
54
-
-
84870253268
-
A comparison of the C-MAC video laryngoscope to the Macintosh direct laryngoscope for intubation in the emergency department
-
[Epub ahead of print]
-
Sakles J.C., Mosier J., Chiu S., et al. A comparison of the C-MAC video laryngoscope to the Macintosh direct laryngoscope for intubation in the emergency department. Ann Emerg Med 2012, [Epub ahead of print].
-
(2012)
Ann Emerg Med
-
-
Sakles, J.C.1
Mosier, J.2
Chiu, S.3
-
55
-
-
84862191159
-
Difficult airway management in the emergency department: glidescope videolaryngoscopy compared to direct laryngoscopy
-
Mosier J.M., Stolz U., Chiu S., et al. Difficult airway management in the emergency department: glidescope videolaryngoscopy compared to direct laryngoscopy. J Emerg Med 2012, 42:629-634.
-
(2012)
J Emerg Med
, vol.42
, pp. 629-634
-
-
Mosier, J.M.1
Stolz, U.2
Chiu, S.3
-
56
-
-
69049116267
-
Tracheal intubation with videolaryngoscopes in patients with cervical spine immobilization: a randomized trial of the Airway Scope and the GlideScope
-
Liu E.H., Goy R.W., Tan B.H., et al. Tracheal intubation with videolaryngoscopes in patients with cervical spine immobilization: a randomized trial of the Airway Scope and the GlideScope. Br J Anaesth 2009, 103:446-451.
-
(2009)
Br J Anaesth
, vol.103
, pp. 446-451
-
-
Liu, E.H.1
Goy, R.W.2
Tan, B.H.3
-
57
-
-
0031454801
-
Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury
-
Watts A.D., Gelb A.W., Bach D.B., et al. Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury. Anesthesiology 1997, 87:1335-1342.
-
(1997)
Anesthesiology
, vol.87
, pp. 1335-1342
-
-
Watts, A.D.1
Gelb, A.W.2
Bach, D.B.3
|