메뉴 건너뛰기




Volumn 107, Issue 2, 2011, Pages 258-264

Comparison of the C-MAC®, Airtraq®, and Macintosh laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization

Author keywords

Airtraq laryngoscope; C MAC laryngoscope; difficult intubation; Equipment; Macintosh laryngoscope; intubation; neck immobilization; tracheal

Indexed keywords

ADULT; ANESTHESIST; ARTICLE; CERVICAL SPINE; CONTROLLED STUDY; ENDOTRACHEAL INTUBATION; FEMALE; HEMODYNAMIC MONITORING; HUMAN; IMMOBILIZATION; INTERMETHOD COMPARISON; LARYNGEAL MASK; LARYNGOSCOPE; LARYNGOSCOPY; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; SINGLE BLIND PROCEDURE; SPINE;

EID: 79960546333     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aer099     Document Type: Article
Times cited : (88)

References (34)
  • 1
    • 0025021272 scopus 로고
    • General anesthesia: Management considerations in the trauma patient
    • Stene JK, Grande CM. General anesthesia: management consider-ations in the trauma patient. Crit Care Clin 1990; 6: 73-84 (Pubitemid 20083798)
    • (1990) Critical Care Clinics , vol.6 , Issue.1 , pp. 73-84
    • Stene, J.K.1    Grande, C.M.2
  • 3
    • 0027239954 scopus 로고
    • Orotracheal intubation in patients with potential cervical spine injuries. An indication for the gum elastic bougie
    • Nolan JP, Wilson ME. Orotracheal intubation in patients with potential cervical spine injuries: an indication for the gum elastic bougie. Anaesthesia 1993; 48: 630-3 (Pubitemid 23219769)
    • (1993) Anaesthesia , vol.48 , Issue.7 , pp. 630-633
    • Nolan, J.P.1    Wilson, M.E.2
  • 4
    • 0032744360 scopus 로고    scopus 로고
    • Evaluation of tracheal intubation difficulty in patients with cervical spine immobilization: Fiberoptic (WuScope) versus conventional laryngoscopy
    • DOI 10.1097/00000542-199911000-00015
    • Smith CE, Pinchak AB, Sidhu TS, Radesic BP, Pinchak AC, Hagen JF. Evaluation of tracheal intubation difficulty in patients with cervi-cal spine immobilization: fiberoptic (WuScope) versus convention-al laryngoscopy. Anesthesiology 1999; 91: 1253-9 (Pubitemid 29506086)
    • (1999) Anesthesiology , vol.91 , Issue.5 , pp. 1253-1259
    • Smith, C.E.1    Pinchak, A.B.2    Sidhu, T.S.3    Radesic, B.P.4    Pinchak, A.C.5    Hagen, J.F.6
  • 5
    • 0027987781 scopus 로고
    • The effect on laryngoscopy of different cervical spine immobilisation techniques
    • DOI 10.1111/j.1365-2044.1994.tb04254.x
    • Heath KJ. The effect of laryngoscopy of different cervical spine immobilisation techniques. Anaesthesia 1994; 49: 843-5 (Pubitemid 24315042)
    • (1994) Anaesthesia , vol.49 , Issue.10 , pp. 843-845
    • Heath, K.J.1
  • 6
    • 0025270124 scopus 로고
    • Adverse respiratory events in anesthesia: A Closed Claims Analysis
    • Caplan RA, Posner KL, Ward RJ, Cheney FW. Adverse respiratory events in anesthesia: a closed claims analysis. Anesthesiology 1990; 72: 828-33 (Pubitemid 20149216)
    • (1990) Anesthesiology , vol.72 , Issue.5 , pp. 828-833
    • Caplan, R.A.1    Posner, K.L.2    Ward, R.J.3    Cheney, F.W.4
  • 7
    • 0032856675 scopus 로고    scopus 로고
    • The American Society of Anesthesiologists closed claims project: What have we learned, how has it affected practice, and how will it affect practice in the future?
    • DOI 10.1097/00000542-199908000-00030
    • Cheney FW. The American Society of Anesthesiologists Closed Claims Project: what have we learned, how has it affected prac-tice, and how will it affect practice in the future? Anesthesiology 1999; 91: 552-6 (Pubitemid 29365039)
    • (1999) Anesthesiology , vol.91 , Issue.2 , pp. 552-556
    • Cheney, F.W.1
  • 9
    • 20444414506 scopus 로고    scopus 로고
    • Esophageal intubation with indirect clinical tests during emergency tracheal intubation: A report on patient morbidity
    • DOI 10.1016/j.jclinane.2005.02.004, PII S0952818005000462
    • Mort TC. Esophageal intubation with indirect clinical tests during emergency tracheal intubation: a report on patient morbidity. J Clin Anesth 2005; 17: 255-62 (Pubitemid 40799088)
    • (2005) Journal of Clinical Anesthesia , vol.17 , Issue.4 , pp. 255-262
    • Mort, T.C.1
  • 10
    • 3242753402 scopus 로고    scopus 로고
    • Emergency tracheal intubation: Complications associated with repeated laryngoscopic attempts
    • Mort TC. Emergency tracheal intubation: complications associ-ated with repeated laryngoscopic attempts. Anesth Analg 2004; 99: 607-13, table ofcontents (Pubitemid 38970445)
    • (2004) Anesthesia and Analgesia , vol.99 , Issue.2 , pp. 607-613
    • Mort, T.C.1
  • 11
    • 33745018618 scopus 로고    scopus 로고
    • Learning and performance of tracheal intubation by novice personnel: A comparison of the Airtraq® and Mancintosh laryngoscope
    • DOI 10.1111/j.1365-2044.2006.04653.x
    • Maharaj CH, Costello J, Higgins B, Harte BH, Laffey JG. Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq® and Macintosh laryngoscope. Anaesthesia 2006; 61: 671-7 (Pubitemid 43871476)
    • (2006) Anaesthesia , vol.61 , Issue.7 , pp. 671-677
    • Maharaj, C.H.1    Costello, J.F.2    Higgins, B.D.3    Harte, B.H.4    Laffey, J.G.5
  • 12
    • 34047101309 scopus 로고    scopus 로고
    • Retention of tracheal intubation skills by novice personnel: A comparison of the Airtraq® and Macintosh laryngoscopes
    • DOI 10.1111/j.1365-2044.2007.04938.x
    • Maharaj CH, Costello J, Higgins BD, Harte BH, LaffeyJG. Retention of tracheal intubation skills by novice personnel: a comparison of the Airtraq® and Macintosh laryngoscopes.Anaesthesia 2007; 62:272-8 (Pubitemid 46680648)
    • (2007) Anaesthesia , vol.62 , Issue.3 , pp. 272-278
    • Maharaj, C.H.1    Costello, J.2    Higgins, B.D.3    Harte, B.H.4    Laffey, J.G.5
  • 13
    • 33645778801 scopus 로고    scopus 로고
    • β or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy - A manikin study
    • β or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy - A manikin study. Anaesthesia 2006; 61: 469-77
    • (2006) Anaesthesia , vol.61 , pp. 469-477
    • Maharaj, C.H.1    Higgins, B.2    Harte, B.H.3    Laffey, J.G.4
  • 15
    • 33750041338 scopus 로고    scopus 로고
    • A comparison of tracheal intubation using the Airtraq® or the Macintosh laryngoscope in routine airway management: A randomised, controlled clinical trial
    • DOI 10.1111/j.1365-2044.2006.04819.x
    • Maharaj CH, O'Croinin D, Curley G, Harte BH, Laffey JG. A compari-son of tracheal intubation using the Airtraq or the Macintosh lar-yngoscope in routine airway management: a randomised, controlled clinical trial. Anaesthesia 2006; 61: 1093-9 (Pubitemid 44575338)
    • (2006) Anaesthesia , vol.61 , Issue.11 , pp. 1093-1099
    • Maharaj, C.H.1    O'Croinin, D.2    Curley, G.3    Harte, B.H.4    Laffey, J.G.5
  • 16
    • 34250891900 scopus 로고    scopus 로고
    • Endotracheal intubation in patients with cervical spine immobilization: A comparison of Macintosh and Airtraq laryngoscopes
    • DOI 10.1097/01.anes.0000267529.71756.f0, PII 0000054220070700000012
    • TM laryngoscopes. Anesthesiology 2007; 107: 53-9 (Pubitemid 46987819)
    • (2007) Anesthesiology , vol.107 , Issue.1 , pp. 53-59
    • Maharaj, C.H.1    Buckley, E.2    Harte, B.H.3    Laffey, J.G.4
  • 17
    • 38349019433 scopus 로고    scopus 로고
    • Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation
    • Maharaj CH, Costello JF, Harte BH, Laffey JG. Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation. Anaesthesia 2008; 63:182-8
    • (2008) Anaesthesia , vol.63 , pp. 182-188
    • Maharaj, C.H.1    Costello, J.F.2    Harte, B.H.3    Laffey, J.G.4
  • 18
    • 34249052791 scopus 로고    scopus 로고
    • The Airtraq® as a rescue airway device following failed direct laryngoscopy: A case series
    • DOI 10.1111/j.1365-2044.2007.05036.x
    • Maharaj CH, Costello JF, McDonnell JG, Harte BH, Laffey JG. The Airtraq as a rescue airway device following failed direct laryngoscopy: a case series. Anaesthesia 2007; 62: 598-601 (Pubitemid 46796322)
    • (2007) Anaesthesia , vol.62 , Issue.6 , pp. 598-601
    • Maharaj, C.H.1    Costello, J.F.2    McDonnell, J.G.3    Harte, B.H.4    Laffey, J.G.5
  • 19
    • 77950880176 scopus 로고    scopus 로고
    • Glidescope, and Airtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins
    • Comparison of the C-MAC videolaryngoscope with the Macintosh
    • McElwain J, Malik MA, Harte BH, Flynn NM, Laffey JG. Comparison of the C-MAC videolaryngoscope with the Macintosh, Glidescope, and Airtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins. Anaesthesia 2010; 65: 483-9
    • (2010) Anaesthesia , vol.65 , pp. 483-489
    • McElwain, J.1    Malik, M.A.2    Harte, B.H.3    Flynn, N.M.4    Laffey, J.G.5
  • 20
    • 0031469105 scopus 로고    scopus 로고
    • The intubation difficulty scale (IDS): Proposal and evaluation of a new score characterizing the complexity of endotracheal intubation
    • DOI 10.1097/00000542-199712000-00005
    • Adnet F, Borron SW, Racine SX, et al. The intubation difficulty scale (IDS): proposal and evaluation ofanew score characterizing the complexity of endotracheal intubation. Anesthesiology 1997; 87: 1290-7 (Pubitemid 28007322)
    • (1997) Anesthesiology , vol.87 , Issue.6 , pp. 1290-1297
    • Adnet, F.1    Borron, S.W.2    Racine, S.X.3    Clemessy, J.-L.4    Fournier, J.-L.5    Plaisance, P.6    Lapandry, C.7
  • 21
    • 0021701206 scopus 로고
    • Difficult tracheal intubation in obstetrics
    • DOI 10.1111/j.1365-2044.1983.tb08932.x
    • Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105-11 (Pubitemid 15103964)
    • (1984) Anaesthesia , vol.39 , Issue.11 , pp. 1105-1111
    • Cormack, R.S.1    Lehane, J.2
  • 22
    • 0031712639 scopus 로고    scopus 로고
    • Assessment of airway visualization: Validation of the percentage of glottic opening (POGO) scale
    • Levitan RM, Ochroch EA, Kush S, Shofer FS, Hollander JE. Assess-ment of airway visualization: validation of the percentage of glottic opening (POGO) scale. Acad Emerg Med 1998; 5: 919-23 (Pubitemid 28409440)
    • (1998) Academic Emergency Medicine , vol.5 , Issue.9 , pp. 919-923
    • Levitan, R.M.1    Ochroch, E.A.2    Kush, S.3    Shofer, F.S.4    Hollander, J.E.5
  • 24
    • 0037328615 scopus 로고    scopus 로고
    • Novel airway devices: Spoilt for choice?
    • DOI 10.1046/j.1365-2044.2003.03047.x
    • Cook TM. Novel airway devices: spoilt for choice? Anaesthesia 2003; 58: 107-10 (Pubitemid 36284736)
    • (2003) Anaesthesia , vol.58 , Issue.2 , pp. 107-110
    • Cook, T.M.1
  • 25
    • 67651071973 scopus 로고    scopus 로고
    • Watching over the medical device industry
    • Lenzer J. Watching over the medical device industry. Br Med J 2009; 338: b2321
    • (2009) Br Med J , vol.338
    • Lenzer, J.1
  • 26
    • 0034874984 scopus 로고    scopus 로고
    • Cervical spinal motion during intubation: Efficacy of stabilization maneuvers in the setting of complete segmental instability
    • Lennarson PJ, Smith DW, Sawin PD, Todd MM, Sato Y, Traynelis VC. Cervical spinal motion during intubation: efficacy of stabilization maneuvers in the setting of complete segmental instability. J Neurosurg 2001; 94: 265-70 (Pubitemid 32786054)
    • (2001) Journal of Neurosurgery , vol.94 , Issue.2 SUPPL. , pp. 265-270
    • Lennarson, P.J.1    Smith, D.W.2    Sawin, P.D.3    Todd, M.M.4    Sato, Y.5    Traynelis, V.C.6
  • 27
    • 0026095511 scopus 로고
    • Elective oral tracheal intubation in cervical spine-injured adults
    • Suderman VS, Crosby ET, Lui A. Elective oral tracheal intubation in cervical spine-injured adults. Can JAnaesth 1991; 38: 785-9
    • (1991) Can JAnaesth , vol.38 , pp. 785-789
    • Suderman, V.S.1    Crosby, E.T.2    Lui, A.3
  • 28
    • 0027414239 scopus 로고
    • Neurologic deterioration associated with airway management in a cervical spine-injured patient
    • Hastings RH, Kelley SD. Neurologic deterioration associated with airway management in a cervical spine-injured patient. Anesthe-siology 1993; 78: 580-3 (Pubitemid 23090493)
    • (1993) Anesthesiology , vol.78 , Issue.3 , pp. 580-583
    • Hastings, R.H.1    Kelley, S.D.2
  • 29
    • 67650092016 scopus 로고    scopus 로고
    • Cervical spine motion: A fluoro-scopic comparison of the AirTraq laryngoscope versus the Macin-tosh laryngoscope
    • Turkstra TP, Pelz DM, Jones PM. Cervical spine motion: a fluoro-scopic comparison of the AirTraq laryngoscope versus the Macin-tosh laryngoscope. Anesthesiology 2009; 111: 97-101
    • (2009) Anesthesiology , vol.111 , pp. 97-101
    • Turkstra, T.P.1    Pelz, D.M.2    Jones, P.M.3
  • 30
    • 24944549606 scopus 로고    scopus 로고
    • Reduction in mouth opening with semi-rigid cervical collars
    • DOI 10.1093/bja/aei190
    • Goutcher CM, Lochhead V. Reduction in mouth opening with semi-rigid cervical collars. BrJAnaesth 2005; 95: 344-8 (Pubitemid 41487345)
    • (2005) British Journal of Anaesthesia , vol.95 , Issue.3 , pp. 344-348
    • Goutcher, C.M.1    Lochhead, V.2
  • 32
    • 54249167043 scopus 로고    scopus 로고
    • 2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization
    • 2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization. Br J Anaesth 2008; 101: 723-30
    • (2008) Br J Anaesth , vol.101 , pp. 723-730
    • Malik, M.A.1    Maharaj, C.H.2    Harte, B.H.3    Laffey, J.G.4
  • 33
    • 66149093148 scopus 로고    scopus 로고
    • Tracheal intubation in patients with cervical spine immobilization: A comparison of the Airwayscope, LMA CTrach, and the Macintosh laryngoscopes
    • Malik MA, Subramaniam R, Churasia S, Maharaj CH, Harte BH, Laffey JG. Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope, LMA CTrach, and the Macintosh laryngoscopes. Br J Anaesth 2009; 102: 654-61
    • (2009) Br J Anaesth , vol.102 , pp. 654-661
    • Malik, M.A.1    Subramaniam, R.2    Churasia, S.3    Maharaj, C.H.4    Harte, B.H.5    Laffey, J.G.6
  • 34
    • 74949099834 scopus 로고    scopus 로고
    • Randomized controlled trial of the Pentax AWS, Glidescope, and Macintosh laryngoscopes in predicted difficult intubation
    • Malik MA, Subramaniam R, Maharaj CH, Harte BH, Laffey JG. Randomized controlled trial of the Pentax AWS, Glidescope, and Macintosh laryngoscopes in predicted difficult intubation. Br J Anaesth 2009; 103: 761-8
    • (2009) Br J Anaesth , vol.103 , pp. 761-768
    • Malik, M.A.1    Subramaniam, R.2    Maharaj, C.H.3    Harte, B.H.4    Laffey, J.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.